| Sl No | Description | Qty | Unit | M/S MANU ENGINEERS AND CONTRACTORS L3 | Ms Salaria Builders L1 | M/S ZTECH L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. | 260 | Per point | 15 ₹3,900 | 5 ₹1,300 Lowest | 10 ₹2,600 |
| 2.00 | Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. | 135 | RM | 20 ₹2,700 | 8 ₹1,080 Lowest | 10 ₹1,350 |
| 3.00 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 16 sq. mm nominal cross section in all as directed by Engineer-in-Charge | 135 | RM | 161 ₹21,735 | 125 ₹16,875 Lowest | 150 ₹20,250 |
| 4.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(a) One light point/one fan point controlled by one switch | 148 | Per Point | 700 ₹1,03,600 | 635 ₹93,980 | 610 ₹90,280 Lowest |
| 5.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size | 54 | Per Point | 800 ₹43,200 | 635 ₹34,290 | 610 ₹32,940 Lowest |
| 6.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(c) One 3 pin 5 Amp socket outlet on same board. | 18 | Per Point | 150 ₹2,700 Lowest | 320 ₹5,760 | 300 ₹5,400 |
| 7.00 | All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by the engr in charge. | 40 | Per Point | 1,700 ₹68,000 | 985 ₹39,400 Lowest | 1,910 ₹76,400 |
| 8.00 | One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. Size complete all as specified and directed by the engr in charge. | 2 | Per point | 700 ₹1,400 | 710 ₹1,420 | 410 ₹820 Lowest |
| 9.00 | M&L Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr In Charge. | 2 | Each | 420 ₹840 | 290 ₹580 | 80 ₹160 Lowest |
| 10.00 | S&F Bell push, flush type, 5 amp Switch , single pole, one way complete all as specified and directed by Engr in Charge. | 2 | Each | 120 ₹240 | 45 ₹90 | 30 ₹60 Lowest |
Tender Value
₹8.8 L
EMD Value
₹20,000
Closing Date
1 Sept 2026, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN-901312 c/o 56 APO
SPL REPAIR TO REWIRING OF BLDG NO T-162 T-163 (OFFICER LIVING) OF 402 (I) ARTY BDE CAMP AND REWIRING OF BLDG NO T326 T327 JCO LINE OF 868 I FD WKSP COY EME AT NURLA MIL STN UNDER AGE INIMU
2026_MES_782985_1
AGE(I)/NIT-42/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NIMU
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹20,000
15 Oct 2026
6 Aug 2026
3 Sept 2026
6 Aug 2026
1 Sept 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. | - | Per point | - | - |
| 2 | Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. | - | RM | - | - |
| 3 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 16 sq. mm nominal cross section in all as directed by Engineer-in-Charge | - | RM | - | - |
| 4 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(a) One light point/one fan point controlled by one switch | - | Per Point | - | - |
| 5 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size | - | Per Point | - | - |
| 6 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(c) One 3 pin 5 Amp socket outlet on same board. | - | Per Point | - | - |
| 7 | All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by the engr in charge. | - | Per Point | - | - |
| 8 | One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. Size complete all as specified and directed by the engr in charge. | - | Per point | - | - |
| 9 | M&L Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr In Charge. | - | Each | - | - |
| 10 | S&F Bell push, flush type, 5 amp Switch , single pole, one way complete all as specified and directed by Engr in Charge. | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_877240.xls
BOQ • 0.67 MB
TENDER.pdf
Tender Documents • 1.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .