| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 CrAccepted-AOC H 12 SECTOR DELTA II GREATER NOIDA DISTT G B NAGAR UP | GREATER NOIDA | G B NAGAR | UP | ₹14.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹14.9 CrRejected-Finance B 108A SECTOR 36 GREATER NOIDA DISTT G B NAGAR UP | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | ₹14.9 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹14.9 CrRejected-Finance | ₹14.9 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹15.0 CrRejected-Finance VILLAGE MILAK LACHCHI POST BEDPURA GREATER NOIDA | ₹15.0 Cr | L4 | Rejected-Finance L4 |
Tender Value
₹15.1 Cr
EMD Value
₹25.1 L
Closing Date
19 Jan 2026, 5:00 pmClosed
SM_TENDER CELL
GNIDA OFFICE
Construction of CC road, CC drain, footpath with Interlocking tiles and repairing of center verge of DSC road from Dadri Railway crossing to GT road, Greater Noida.
2026_GNIDA_1103550_11
SM/(E-TENDER CELL)/2025/691 DATED-31.12.2025
Open Tender
Civil Works
365 days
GREATER NOIDA
REFER TENDER DOCUMENT
5 documents required · 5 mandatory
₹6,770
₹25.1 L
19 Mar 2026
5 Jan 2026
22 Jan 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
Road work Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads. Transporting to site, spreading, grading to required slope and compacting to meet requirement of Table No 300-2: lead upto of 5.00KM (MORTH--20/305/3.18)
Granular sub-base with graded material, plant mix method Construction of granular sub-base by providing close graded material, mixing in a mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. MORTH/4.01/401(A) Grading-II closed Graded
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin-charge. (DSR-18/16.80) Design mix shall be as per MORTH Cl. 401 & IRC:SP:49
RCC Grade M-40 using batching plant & manual placing (MORTH-20/12.11/B//Case-II) Design mix shall be as per IRC:44-2019
Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete. (DSR-18/16.44)
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. (DSR-18/16.46.1)
Steel reinforcement for RCC work including straightening cutting bending placing in position and binding all complete upto plinth level
Thermo Mechanically treated bars of grade Fe-500D or more. (SAIL Steel) (DSR-18/5.22.6/AR)
Footpath & Centerverge Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge. (DSR-18/16.65)
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.(DSR-18/16.50)
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR-18/16.83)
Cement concrete with 4cm gauge Approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials labour tools & Plants etc required for proper completion of the work
8:4:1 (1 Cement 4: Coarse sand :8 graded stone aggregate 40mm nominal size) (SOR-20/281/5.08)
Relaying of interlocking tiles available at site including supply of all labour material T&P etc. completed as per directed by Engineer-in-charge (AR/GNIDA)
Providing and laying I Shaped Interlocking tiles Rubber moulded 80mm thick precast cement concrete having plan dimension 200x(160+120mm) with compressive strength not be less than 40Mpa (M-40) and weight 5kg, laid in required pattern over and including averege 50mm Thick Compacted bed fine sand and filling the joints with fine sand all complete as per direction of engineer-in-charge with conforming to ISI-15658-2006 SOR/A.R. Grey colour.
M-150 brick work in 1:6 cement & fine sand 1.25 FM mortar in foundation and plinth including supply of all material labour and T&P etc required for proper completion of the work. (SOR-20/303) same as item no 303 but in 1:4 one cement & four fine sand of 1.25 F.M. mortar. (SOR-20/305) Same as item no 305 but in 1:4 one cement & four coarse sand of 2.20 F.M. mortar. (SOR-20/305(A))
Cement conrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR-20/279) Same as above item no 279 but with 2cm gauge stone grit instead of 4cm gauge stone ballast. (SOR-20/279(a)
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (DSR-18/13.4.2)
Providing wall putty on new surface with approved quality material of Berger/J.K./Birla or similar make 2 coats.(SOR-20/15.22 New Item)
Painting or varnishing with valsper or other approved high grade enamel or super par synthetic clean varnish complete one coat over previously painted surface including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. paint to be used should confirm ISI no. 105/106/133-1950 (SOR-20/647)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR-18/10.25)
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DSR-18/10.25.2)
RCC Drain work Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar. (DSR-18/15.7.4)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR-18/15.3)
Excavation in foundation in ordinary soil (Loam clay or sand) including lift upto 1.50 M and lead upto 30.00M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer incharge upto a distance of 30m from the foundation trenches (where machine con not reach/move) (SOR/251 (A)/4.1.1)
Depth from 0.0 to 1.5M below G.L.
Depth from 1.5 to 3.0M below G.L.
Cement concrete with 4cm gauge Approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials labour tools & Plants etc required for proper completion of the work
8:4:1 (1 Cement 4: Coarse sand :8 graded stone aggregate 40mm nominal size) (SOR-20/281/5.08)
Reinforced Cement concrete in open foundation complete as per Drawing and Technical Specifications. (MORTH-20/9.06/E/Case-II)
RCC Grade M-25 using batching plant transit mixture and manual placing (MORTH-20/9.06/E/Case-II)
Steel reinforcement for RCC work including straightening cutting bending placing in position and binding all complete upto plinth level
Thermo Mechanically treated bars of grade Fe-500D or more. (SAIL Steel) (DSR-18/5.22.6/AR)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR-18/10.25)
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DSR-18/10.25.2)
Labour cess and GST will be paid extra as per Govt. orders.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.74 MB
PreQ_ConCCroad_CCdrain_DSCroad.pdf
Tender Documents • 0.98 MB
BOQ_2035336.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid