Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹38.2 L+₹4.8 L (14.2%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹75,720
Closing Date
5 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
UPGRADATION OF BLDG NO P63 SWITCH ROOM SUB STN BLDG IN CQA EE TECHNICAL COMPLEX AUNDH CAMP PUNE UNDER GE MH AND RH KHADKI
2025_MES_709965_2
8682/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹75,720
Yes
31 Jul 2025
14 Jun 2025
7 Jul 2025
14 Jun 2025
5 Jul 2025
21 Jun 2025
14 Jun 2025 - 28 Jun 2025
Amount
Material and Labour for removing of old water proofing treatment and cleaning the surface of slab and cleaning with wire brush, removing dust,foreign materials and removing the rubbish off the site to a distance n.exc 100m complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) on roof top, chajja for maintaining of slope coving,benching etc complete all as specified and directed.
Material and Labour for Rendering 10 mm thick on concrete surfaces of roof in cement plaster in 1:3 cm mixed with WPC @ 3% by weight of cement finishing even and smooth to receive water proofing treatment complete without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid seperately.
Material and Labour for cleaning the plaster /concrete surfaces with wire brushes and applying water proofing treatment ,one coat of bituminious primer @ 0.25 kg per sqm and providing 3 mm APP modified water proofing Membrane weight 3.5 to 4.0 kg /sqm by torch application method including painting entire roof surfaces with one coats of bitumastic aluminous paint complete all as specified and directed.
Taking up or down steel tubing 20 mm dia and connection including cleaning for refixing complete all as specified and directed.
Taking up or down steel tubing 15 mm dia and connection including cleaning for refixing and removing to store complete all as specified and directed.
Material and Labour for tube medium grade 20 mm dia, galvanized steel with all fittings fixed complete to wall, ceiling or laid in floors etc complete all as specified and directed.
Refixing old steel tubing and connection of 20 mm dia in new or old position (walls, ceiling ,floor etc) complete all as specified and directed.
Material and Labour for tube medium grade 15 mm dia, galvanized steel with all fittings fixed complete to wall, ceiling or laid in floors etc complete all as specified and directed.
Refixing old steel tubing and connection of 15 mm dia in new or old position (walls, ceiling ,floor etc) complete all as specified and directed.
Supply and Fixing in repairs, gun metal globe or gate valves 20 mm dia ,with iron wheel head,screwed both ends for iron pipes complete all as specified and directed.
Dismantling water tank of any description of capacity 500 ltrs complete all as specified and directed.
Supply and Fixing rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 500 ltrs capacity complete all as specified and directed.
Supply and Fixing in repairs ball brass valve 20 mm dia high pressure with poly-thine float and fly nut for following bore of pipe, complete all as specified and directed.
Taking down chowkats and frame exc 1.5 Sqm and n.exc 4.0 sqm incl shutter with out taking off shutters from frame and removing from site complete all as specified and directed.
Taking down chowkats and frame n. exc 1.5 Sqm incl shutter with out taking off shutters from frame and removing from site complete all as specified and directed.
Supply and Fixing box type steel windows with side hung shutters incl projecting type hinges with steel handle steel peg stay complete with glazing bar dovetailed / weldeds incl guard bar etc complete all as specified and directed.
Supply and Fixing Steel ventilator with top hungshutter including hinges, steel pegstay, complete all as specified and directed.
Supply and Fixing 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed.
Supply and Fixing 4mm thick Sheet glass, obscured or frosted and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed.
Supply and Fixing Pressed steel door frame for doors with one or more rebate incl necessary fixing lugs, hinges lock strike plate, etc complete as specified size 105 x 60mm complete all as specified and directed.
Material and Labour for PCC(1:3:6) type C1 using 20 mm graded stone aggregate as in coping, filling of pressed steel door frame including l necessary form work and finished even and smooth without using extra cement complete all as specified and directed.
Material and Labour for 2nd class hard wood 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and Fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
Supply and Fixing Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:) with particle board core, with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Material and Labour for Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm long complete all as specified and directed.
Supply and Fixing Aluminium alloy, anodised, sliding door bolt of 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Material and Labour for Aluminium handles, cast type, anodised for doors 150 mm long complete all as specified and directed.
Material and Labour for Aluminium handles, cast type, anodised for doors 100 mm longcomplete all as specified and directed.
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed.
Material and Labour for Rendering 10mm thick, on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Material and Labour for Rendering 10mm thick, on fair faces of brick work or concrete surfaces of ceiling in CM 1:4 with finished even and smooth without using extra cement complete all as specified and directed.
Material and Labour for Rendering 15mm thick, on fair faces on brick/ block masonry surfaces in CM 1:4 including WPC 3% by weight of cement (WPC will be measured & paid separetaly) complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
Material and Labour for coloured joint free Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles laid over and including cement screed 15mm thick in CM 1:6 complete all as specified and directed.
Material and Labour for coloured Glazed ceramic tiles in vertical surface of size 300mmx450mm x 6 to 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles laid over and including cement screed 10mm thick in CM 1:4 complete all as specified and directed.
Material and Labour for Machine cut KOTA stone slab flooring 20 to 25 mm thick laid and jointed inneat cement slurry mixed with pigment to match the shade including cutting and polishing over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Ditto as per item No. 38.00 above but in riser, step, skriting, dados and pillar over and including 10 mm thick plastering in cement morter 1:4 complete all as specified and directed.
Supply and Fixing in repairs aluminium anodised Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Supply and Fixing in repairs PVC connection of 450 mm length, suitable for 15 mm bore pipe with PTMT nuts complete all as specified and directed.
Supply and Fixing in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx 350mm regular size with mirror and PVC shelves complete all as specified and directed.
Supply and Fixing in repairs stopvalves cast copper alloy screwed down high pressure withcrutch or butterfly handle screwed both ends for iron pipe 15 mm dia complete all as specified and directed.
Supply and Fixing in repairs bib taps CP Brass with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia complete all as specified and directed.
Supply and Fixing in repairs viterious china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings complete all as specified and directed.
Supply and Fixing in repairs pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes 15mm dia complete all as specified and directed.
Supply and Fixing in repair grating dome 125mm dia with waste hole of PTMTminimum weight 40 grams complete all as specified and directed.
Supply and Fixing in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete all as specified and directed.
Supply and Fixing in repairs PVC High/Low level flushing cistern 10 litrescapacity including all fittings i.e float valve, syphon, flushpipe,brackets complete all as specified and directed.
Material and Labour for cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 (using 20 mm graded stone aggregate) as required -depth of embedded portion of holdfast or lugsmeasured from the face of jamb into the wall complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in hold fast complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregate) as in filling pressed steel door frame etc complete all as specified and directed.
Material and Labour for painting to wooden surfaces of any description over 10 cm width or girth incld prepration of new or untreated surface and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Material and Labour for preperation of new or untreated surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Material and Labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper of approved colour and pattern over a coat of primer over 3mm thick wall care putty finished even and smooth complete all as specified and directed.
Material and Labour for preparation of new steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed.
Material and Labour preparation of new plastered surfaces on ceiling and applying two coats of white wash over 3mm thick wall care putty finished even and smooth complete all as specified and directed.
Demolition of stone/brick /PCC block masonry built in cement mortar or cement lime mortar complete all as specified and directed.
Material and Labour for Pre-cast cement concrete block masonry type C1 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Demolition of reinforced concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and Labour for rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Material and Labour for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and Labour for cement concrete in foundations, filling and mass concret type D2 (1:4:8) (using 40mm graded stone aggregate) complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C1 (uisng 20mm graded stone aggregate) 75 mm thick as in Plinth, Path, hardstanding floor with fair finish surface with out using extra cement complete all as specified and directed.
Supply and Fixing in repairs Steel rolling shutters of 1mm thickness of laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple, ball bearing, spring and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Supply and Fixing Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supply and Fixing Mild steel plates, plain or chequered, 6 mm thick for fixing in cable duct portion complete all as specifed and directed.
Material and Labour for 80mm thick M-40 coloured glossy finished interlocking tiles/ blocks any shape and size, jointed & pointed in neat cement slurry with pigment to match the shade of tile etc complete all as specified and directed.
Material and Labour for sand/ stone dust filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Excavating in post holes (or similar holes) in hard/dence soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type weight not exceed 4kg per sqm (size of mesh and dia of wire as directed by Engg-In-Charge) complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply and Fixing MS angle iron in fencing posts & struts including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mesh etc) including all necessary, drilling, bolting or riveting etc and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
Supply and Fixing Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410-W(Gde E-250) quality-B complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B2 ( 40 mm graded stone aggregate) as in foundation of rails post etc.complete all as specified and directed.
Supply and Fixing 10 mm dia MS round bars for tightening of chain link fencing woven through chain link & fitted complete all as specified and directed.
Supply and Fixing galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, Fan, socket,Geyser or power) complete (fittings such as switches, ceiling roses, pendants, regulators, light fitting etc, removing materials to store for keeping in safe custody for credit (credit for above items should be made as per conditon of material separately) and making good distrubed surfaces of wall/floor/ceiling etc complete all as specified and directed.
Material and Labour for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor as per IS 694 (1990) drawn through non metallic rigid PVC conduit of size not less than 25mm dia with concealed wiring and accessories in walls/ceilings with 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including pressed steel terminall boxes of suitable thickness wire , for house modular socket , bell with modular plate switch/regulators etc complete all as specified and directed for following .Cable make: make polycab /Finolex/ RR
One fan/light point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 82 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm cable as earthwire complete all as specified and directed..
All as per item No 82 here-in-before but wiring with 4.0 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated but unsheathed single core for 16 Amps power point on independent board and 4.0 sqmm cable as earthwire complete all as specified and directed.
Taking down old submain wiring and Material and Labour for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Conduit concealed in wall of size not less than 25mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size complete all as specified and directed. Note: Two run of single core PVC insulated multstrandedd copper conductor cable & one run of PVC insulated copper conductor cable green in colour with one run of PVC pipe medium grade shall be measure and paid one unit (RM) length.
Supply and fix in repair modular switch 1 way 6A, 240 Volts AC 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin, 240 Volts AC combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 16A 2/3 pin, 240 Volts AC combined 2 module complete all as specified and directed.
Supply and fix in repair modular switch 16A 1 way, 240 Volts AC 1 module complete all as specified and directed.
Supply and fix in repair ceiling rose surface bakelite with three terminal 2 Amps 240 Volts complete including taking down rusted metal box and necessary plastering work and finish with existing wall paint complete all as specified and directed.
Supply and Fixing in repair sheet metal enclosures for double door distribution board factory made duly painted 12 way SPN and neutral 240 v with 200 amps rated bus bar , concealed in wall suitable for fixing MCB /Isolators complete all as specified and directed. Make:L & T/legrand/Standard
Supply and Fixing in repair sheet metal enclosures with socket plug top and MCB 20 amp double pole factory made duly painted 240 v , concealed in wall suitable for fixing gyser /AC complete all as specified and directed. Make:L & T/legrand/Standerd
Supply and fixing miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, 240V, 10 KA 'B' curve in the MCB DB Complete with connection testing and commissioning., complete all as specified and directed.
Ditto same as item no 93 but SPN 32 Amps, 10 kA complete all as specified and directed.
Taking down old unserviceable fitting and Supply and Fixing wall mounted extruded aluminium housing high quality indoor batten LED tube 22 watt colour temperature 6500 K (4 feets long) lumen 2000 -3000, PF> 0.95, THD less 10% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement acomplete all as specified and directed. Make : Havells/wipro/Halonix.
Ditto item no -95 above but 10 Watt (2 feets Long) complete all as specified and directed. Make : Havells/wipro/Halonix.
Taking down old unserviceable Bldg security light and Supply and Fixing fix high efficent LED building security light 30 watt , 230 V , lumen 2000 -3000, PF> 0.95, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connector to ceiling rose complete all as specified and directed. Make:- Halonix, phillips, Havells.
Supply and Fixing in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw/Nut Bolts etc for fixing complete all as specified and directed.
Taking down existing Ceiling fan from any height and servicing/overhauling the fan by changing its bearings , capacitors, down rods , fan canopy , rubber yoke , gun metal bush and rewinding the fan with suitable size of copper wire and assembling the fan after proper cleaning of fan blades and body complete all as specified and directed. Note :- The rates are inclusive of all minor spares required for making the fan fully functional.
Taking down existing Exhaust fan from any height and servicing/overhauling the fan by changing its bearings , capacitors, blades and rewinding the fan with suitable size of copper wire and assembling the fan after proper cleaning of fan blades , louvers and body complete all as specified and directed. Note :- The rates are inclusive of all minor spares required for making the fan fully functional.
Taking down unservicable earthing and Material and Labour for earthing complete with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt & charcoal including , excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board complete all as specified and directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. )
Incomer :- (a) ACB 630 Amps, 4 pole, 50 KA, EDO type. - 03 Nos (From Transformer No-1 , Transformer No -2 and From Main receiving Sub station all 03 ACB interlocking with each other) (b) Under voltage release. - 03 Nos (c) Micro switch. - 03 Nos (d) Indicator with switch. - 03 Nos (e) Control Indicator - 12Nos (f) Multifunction meter - 03 Nos (g) Current transformer . - 09 Nos (h) Voltage monitoring relay. - 03 Nos (j) Relay interlock logic control for incomers. - 01 set
Out going (a) ACB 630 Amps , 4pole, 50 KA, MDO type - 01 Nos (b) Micro switch - 01 Nos (c) MCCB 400 Amps, 4 pole, 35 Amps - 02 Nos (d) Aux Contact blocks for MCCB of rating (400, 250 & 125) Amps - 08 Nos (e) On/Off/Trip indiator with fuse - 02 Nos (f) MCCB 250 Amps , 4p, 36 KA - 03 Nos (g) MCCB 125 Amps , 4 p, 25KA - 03 Nos (h) Spreader Link, Extended rotary handle, Aux contact block, lightening timmer , contact for timer, Aliuminium bus bar with suitable size as per recommendationd of OEM, Panel to be made from 3 mm thick CRCA sheet duly spary painted with control wiring and other panel accessories Note : (i) Complete control panel wiring between three incomer (i.e, TR No 1, TR No 2 and From MRS) ACB including interlocking wiring to ensure safe working. (ii) Complete power panel wiring between bus bar to each outgoing breaker with suitable size of aluminium bus bar of proper insulation with colour code.
Disconnecting incoming and outgoing cable/busbar connections from the old unsv main LT feeder panel dismantling it completely along with foundation complete ,taking out old cable from the cable ducts and removing the old cables from the duct and Supply, install, testing and commissioning new LT panel outer sheet made out from 3 mm thick CRCA sheet and complete inner shell made out with 2mm thick CRCA sheet, duly powder coated, double door front and back opening complete with bus bar chamber, 600 Amps aluminium bus bar for 3 phase and 300 Amps bus bar for neutral complete with control panel wiring with 1.5 sqmm PVC insulated multistranded copper wire and power panel wiring with suitable size of aluminium bus bar between bus bar and each outgoing with following details as specified under - (a) MCCB 400 Amps 4P, 36 KA - 01Nos (Incomer) (b) MCCB 250 Amps 4P, 25 KA - 04 Nos (Out going) (c) MCCB 100 Amps 4P, 25KA - 01 Nos (Out going) (d) Indicator with switch. - 03 Nos (e) Control Indicator - 03 Nos (f) Multifunction meter - 01 Nos (g) Current transformer . - 03 Nos (h) Change Over switch 400 Amps - 01 Nos (h) Spreader Link, Extended rotary handle, Aliuminium bus bar of suitable size as per recommendation of OEM, Panel to be made from 2 mm thick CRCA sheet duly spary painted with control wiring and other panel accessories
Servicing and maintenance of change over panel of capacity 400 amps indoor type by disconnecting and removing all the incoming and outgoing cable connections from change over and cleaning of dust with air blower, replacement of unserviceable contact parts, handle, burnt contact links, old/burnt lugs, unserviceable indicator lamps, reconnecting them after proper cleaning of contacts with CRC solution and fixing of hanging front and rear openings with new hinges welding etc. including painting of complete panel included stand (after proper scrubbing) with synthetic enamel paint (ordinary tint) one coat as per specified colour code including writing of panel/feedar panel location using black synthetic paint complete all as specified and directed. Note : (i) Cost of civil work for fixing the changeover panel to wall/floor, labour, painting of panel, cotton waste and thimbles and T&P required for upkeeping/maint work is inclusive in quoted rate.
Supply and lay for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 3.5 core including cable gland, nut bolts washers & lugs complete all as specified and directed.
All as per item No-106 but 50 sqmm 3.5 core
All as per item No-106 but 70 sqmm 3.5 core
All as per item No-106 but 120 sqmm 3.5 core
All as per item No-106 but 185 sqmm 3.5 core
All as per item No-106 but 240 sqmm 3.5 core
All as per item No-106 but 300 sqmm 3.5 core
Supply and Fixing Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4/3.5 core, complete all as specified and directed. Make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M
Supply and Fixing Heat shrink straight through joint LT 1100 volts grade 70-120 sqmm, 3.5 core, complete all as specified and directed. Make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M
Supply and Fixing Heat shrink straight through joint LT 1100 volts grade 150-185 sqmm, 3.5 core, complete all as specified and directed. Make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M
Supply and Fixing Heat shrink straight through joint LT 1100 volts grade 240-300 sqmm, 3.5 core, complete all as specified and directed. Make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of electric cable in soft / loose soil and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated meterial to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and Labour for natural dry river sand cushioning including spreading, levelling and hand punning to underground cable in trench complete all as specified and directed. Note : Punned thickness shall only be measured and paid.
Material and Labour for protection with PCC cable cover class LV, type-I, flat size 250x150x40 mm factory casted ISI marked complete all as specified and directed.
Supply, installation and commissioning of advance maintenance free system based earthing comprising of following accessories (a) Set of 04 Nos 3000 mm long, 17.0 mm dia earth electrode made of 99.99% copper circular rods with connect copper strip and electrode with the help of copper brazzing of incoming copper strips of size 25 x 3 mm of length as per site requirement upto Bus bar as decided by Engr - in-Charge and distance between each copper earth electrode is minimum 3 Meter . (b) Copper bus bar of size (300 x 25 x 6)mm act as test point connect with copper nuts and bolts with post insulator.(Nuts/bolts as required is included in the cost). (c) Poly propylene earth pit cover of size 300 x 300 mm (with safe working load 2000 Kg) - 04 Nos (d) Copper bus bar of size (250 x 50 x 6)mm exothermically welded with main earth electrode (e) Each pit filled with earth enhancement compound /chemical (Magnesium sulphate) only (min 75 Kgs/pit) all as specified. (f) Required result of earthing less than 01 Ohm . If desired Ohmic value is not achieved then additional set of 1 No of 3000 mm long, 17.0 mm dia earth electrode made out of 99.9% copper rod with allied items, 01 x Pit cover, 01 x Sub bar as (d) above 75 Kg of chemical shall be provided by contractor without any extra cost to Govt. No price adjustment shall be made, if additional set is not required complete all as directed of Engr- in-charge (g) Necessary excavation work in any type of soil/strata, returning filling and removal of soil is included in the aquoted rates. (h) Site inspection for complete Earthing work is mandotry for the Contractor befour quoting the tender. No explanation/doubts will be entertained later. (j) Any damage done to govt property during the execution of work will be make good by the contractor at his own cost.
Taking down LT cable of any size upto 300 sq mm carefully from trenches / poles / ducts / LT Panel/OH conductors and relaying the same after fixing of new panel board in substation bldg with suitable size of lugs and cable glands etc at sub station bldg complete all as specified and directed. Note :- The rates are inclusive of cost of lugs and cable glands of suitable size.
Adinath Technical Services (BID ID -3339612)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .