| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC H NO 959 SECTOR 3 ROHTAK | L1 | Accepted-AOC accepted | |
| 2 | L2₹18.0 L+₹1.1 L (6.75%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | L3₹18.8 L+₹1.9 L (11.5%)Rejected-AOC 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-AOC rejected |
Tender Value
₹18.2 L
EMD Value
₹36,500
Closing Date
23 Dec 2022, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
Principal, Govt. ITI Asaudah (Jhajjar) vide letter under reference above intimated that deptt. has applied for extension of load is 49.8 KW and increased load is 64.8 KW. Hence a separate transformer is needed. According to meet up with the requireme
2022_HRY_249360_1
2022A4048182 91ED 4DB0 B014 2A4183AA9313667BAR
Open Tender
Electrical Works
Works
60 days
ASAUDA TODRAN
Technical documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹36,500
Yes
23 Jun 2023
8 Dec 2022
26 Dec 2022
8 Dec 2022
23 Dec 2022
8 Dec 2022
Amount
HSR Items
[20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge
[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects.
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
[23.22.1.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.6. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 300 Amp, 25 KA
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia
NS Items
Providing and fixing of stay set complete with stay wire with dis insulator as per specification upto the entire satisfaction of Engineer-in-charge of work...
Supply and erection of Fire extinguisher ISI mark Co2 type of 4.5 Kg. capacity as per IS 7285 duly erected / hung on wall with hooks with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work..
Supply and erection of heat shrinkage type end termination jointing kit indoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable/ ABC cable complete with all the kit contents including earth continuing connection along with 3 nos. crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. (i) Suitable for 16 to 50 sqmm 3 core XLPE Cable
Supply and Erection of LED flood light 150 W of Makes: Surya make SLE FL 150W IP66 LUMOS MAX or its equivalent model of Philips /Wipro/Bajaj with lense with high power LED flood light in aluminium PDC housing, toughened glass cover with IP 66 protection and accessories required to complete the job in all respect including erection an making connection with other petty material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of the work.
Supply, erection, testing and commissioning of 11 KV indoor H.T. Metering panel complete with CTs, PTs cubical and electronics meter with accuracy class 0.5 as per requirement / approved by UHBVNL Consisting of the following : Cubical panel free standing floor mounting type made of sheet steel 14-G SWG CRCA sheet with channel iron base frame spray paintd with strong Synthetic grey channel paint as per size and design approved by UHBVNL . 3 Nos. 11 KV CTs of rating as approved by HVPN for indoor installation of approved make of HVPN. One No. 11 KV PT 11000/110 Volts 10 KA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of HVPN. Digital electronic meter 3 Phase 4 wires 0.5 accuracy for recording reading operating system for difference kind of readings. The cubical panel will be complete in all respect including interconnection, internal wiring with PVC copper cable its testing and approved of all items by HVPN including cost of all testing/approved charges of all items of HVPN including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge ofthe work.
Supply, erection, testing and commissioning of cubical type dust and vermin proof LT automatic power factor control panel 80 KVAR capacity suitable for automatic operation and control power factor within the set limit free standing floor mounting made out of 14 G mild steel sheet with channel iron base frame painted with stoving synthetic light grey enameled paint suitable for operation on 3 phae 4 wire 50 cycles, per second 400 / 440 volts AC supply equipped with the following ( as per diagram attached ) 1 No. automatic power factor control relay of GE / LandT make space for incomer 200 amp tripple pole MCCB. 1 No. power factor relay LandT / Neptune. A set of pilot lamp ( 3 Nos. ) phase indicating lamp of LandT make iron clad bus bar chamber suitable for 200 Amp. 440 V having 3 Nos. phase copper bars of cross-section 25 mm x 05 mm and 1 No. neutral copper bars of cross-section 20 mm x 5 mm duly tinned and insulated with polyvinyl chloride sleeving with requisite clearance as per ISS connection from incomer 250 amp. 4 pole MCCB to bus bar by means of solid copper strips of requisite capacity duly tinned and insulated with PVC sleeving. 2 Nos. 3 Phase 20 KVAR capacitor ( Total 40 KVAR ). 2 Nos. 3 Phase 10 KVAR capacitor ( Total 20 KVAR ). 4 Nos. 3 Phase 5 KVAR capacitor ( Total 20 KVAR ). Make: Havells, Epcos, Neptune, LandT and Siemens 2 Nos. 3 Phase 63 Amp. contactor for 20 KVAR capacitor Make: LandT
Supply, erection, testing and commissioning of outdoor type copper wound, transformer of 250 KVA 11 / 433 KV, 3 Phase, 50 Hz complete in all respect upto the entire satisfaction of Engineer-in-charge of work ( on existing pole / plateform including first filling of oil conforming to IS 1180 level -2- (Only valid approved makes) KVA 250 No. load voltage ratio 11/ 433 KV No. of Phase 3 Frequency cycles 50 Hz Types Double wound core type Copper wound. Cooling ONAN Duty outdoor Vector Group ISS-DYN 11 / IS 2026 /77 Tapping on HV compensation plus 5% to - 5% Insteps of 2.5% Temperature rise (Oil / res.00) 500 / 550 C Attitude upto 1000 m above MSL Off circuit tape changer Externally hand operated Oil conservator with filling hole and cap Plain oil level gauge with minimum level marking Thermometer pocket 4 Nos. Plain roller undirectional. 1 No. 4` dial type thermometer Silica Gel breather
Ist filling of oil. Drain cum filter valve with plug. Rating and diagram plate. Two earthing terminals Lifting arrangement Explosion vent Air release plug. Oil conservator tank Shunt off valve between buchloz and conservator TERMINATION HV-3 Pole single glands cable box suitable for reception of one No. 3 core upto 120 sqmm HT XLPE cable including compound for filling the cable end box with aluminium lugs / thimble. LV- 4 Pole 3 glands cable boxes suitable for 3 Nos. 240 sqmm 3.5 core Polyvinyl chloride cable having extended copper bars of requisite Capacity from LT bushing for making connections with cable including cost of aluminium lugs, thimbles LV : Neutral suitable cable Box for earthing provided.
Erection of MS Angle 50 x 50 x 6 mm M.S. flat and nuts and bolts including cutting, bending to the required shape drilling holding carriage, painting loading and unloading complete in all respect.
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI marked laid in existing pipe / trenches / surface with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work (i) 50 Sq. mm 3 Core XLPE Cable.
Supply and Erection of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfation of Engineer-in-Charge of the work. (i) 120 Sqmm 3.5 Core Cable (Armd.)
Supply and Erection of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfation of Engineer-in-Charge of the work. (ii) 240 Sqmm 3.5 Core Cable (Armd.)
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washers etc. as required. (Based on DSR 13.13)
Providing and fixing of wire mesh jali around the transformer of size 4`x 8` made out of 75 x 25 x 3.25 mm jali fixed with angle iron frame made out of M.S. angle 50 x 50 x 6 mm support of M.S. flat 50 x 6 mm and fixed in C.C. Block 1:2:4 including cutting, welding etc. as per drawing complete in all respect upto the entire satisfaction of the Eng.-in-Charge.
S.S. Enterprises
J.B.S.Electrical Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .