Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹11.7 L+₹53,382 (4.79%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹11.7 L+₹56,077 (5.03%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹12.2 L+₹1.1 L (9.90%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹12.4 L+₹1.3 L (11.4%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹14.5 L
EMD Value
₹28,920
Closing Date
26 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
PROVISIONING OF TECHNICAL TRAINING LECTURE ROOM AND TECHNICAL LIBRARY IN R/O 944 LT AD REGT WKSP (COMP) UNDER GE (I) KANPUR
2024_MES_648330_1
GE(I)/KAN/T-96 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹28,920
Yes
29 Jun 2024
29 Mar 2024
3 May 2024
29 Mar 2024
26 Apr 2024
12 Apr 2024
Amount
Surface dressing n.exc 15 cm deep and getting out as in soft/loose soil complete all as specified and directed.
Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and laying cables n exc 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
M&L for PCC 1:4:8 Type D2 (40mm graded aggregate) as in foundation complete all as specified and directed.
M&L for RCC M-25 Design mix as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc and mass concrete complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC M-25 Design mix (20mm graded aggregates) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies, chhajas, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L formwork to sides of concrete foundation footings, bases of columns raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work : vertical or to batter Rough finished surfaces of concrete complete all as specified and directed.
M&L formwork to sides of pillars, post, struts, piers, columns and stanchions for fair finished surface complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams etc for fair finish surfaces complete all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, shelves, chajjas and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT bars 5mm dia and over upto 10mm dia bar as in stirrups cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 with old size brick, complete all as specified and directed.
M&L rendering15mm thick in CM 1:6 on fair faces of brick/conc surfaces of walls complete all as specified and directed.
M & L rendering 15 mm thick in CM 1:4 with water proofing compound (WPC shall be measured separately ) complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 plaster on ceiling surfaces complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L broken brick hardcore of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L PCC 1:3:6 type C2 using 40 mm graded stone agg as in sub base flooring complete all as specified and directed.
M&L for vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM(1:4) complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection & finishing surface even and smooth with using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint (any Colour ) over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coat oil bound distemper over a coat of primer over applying a coat 1 mm of wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc complete all as specified and directed.
M & L rendering 10 mm thick in CM 1:4, as on RCC roof with water proofing compound (WPC shall be measured separately) complete all as specified and directed.
Supply only water proofing compound, ISI marked complete all as specified. MAKE : PIDIPROOF WL (Dr FIXIT) or equivalent ISIS marked complete all as specified and directed.
M&L water proofing treatment to roof slab with APP modified polymeric membrane thickness not less than 3 mm plain finish (weight of membrane not less than 3.80 Kg +/- 5% per Sqm) and glass fibre reinforcement complete all as specified and directed by Engineer-in-Charge with following courses of descriptions below:- (a) The surface of roof, parapet and gutters and drains mouth etc over which waterproofing treatment is to be applied shall be thoroughly cleaned of all foreign matter, moss dust etc by wire-brushing and dusting. For cast iron/PVC drains outlets a grove shall be cut around to tuck in the treatment. Concrete angles-fillets provided at junctions between roofs and verticals faces of walls (parapet and other walls) around obstacles such as pipe, chimney stacks etc and other similar situation to ease up about corners. (b) On the prepared surface one coat of Solvent based bituminous primer (Sika @ WP shield Primer or other techno commercially Equivalent make of STP/IWL ) shall be applied @ 0.35 to 0.50 Kg/sqm till the surface is properly impregnated. The time delay of laying of membrane after application of primer shall be as per manufacturer instructions. (c) Laying of polymeric waterproofing membrane and bonded completely to the substrate & the overlaps are then sealed /fused by flame torch as per manufacturer instructions. (d)The overlaps shall be of minimum 4 Inch (100 mm) on longitudinal direction and transverse direction and sealed by the flame-torch. (e) Special care is to be taken at singularities such as drains expansion-joints etc Note : The waterproofing work as specified has to be executed by the manufacturer / approved applicator of the manufacturer only. Approved applictator shall have min five years experience in respecive fields i.e. Water proofing treatment. A MoU for waterproofing work as specified shall be executed between the contractor and the manufacturer / approved applicator of the manufacturer before start of the work and got approved by the GE in writing. Certificate of completion alongwith guarantee shall be submitted by the contractor for the water proofing work.
S&F for factory made uPVC white colour Sliding window of area not exc 2 Sqm each, three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose) complete all as specified and directed.
S&F for 4.80 mm thick Sheet glass, ordinary quality n exc 0.5 sqm in each pane complete all as specified and directed.
S&F, aluminium chequered grills as on uPVC windows, wight n.exc 0.50 kg / sqm and fixed complete all as specified and directed.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of decorative type/wood grain printed colour of size 50 X 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type/wood grain printed colour flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S & F 200mm stainless steel fancy handle of approved make fixed with SS screws etc. complete all as specified and directed.
S & F 300 mm Stainless steel sliding door bolt with hasp and staple(bolt type) including fixing with necessary accessaries complete all as specified and directed.
S & F 150mm long aluminum anodised extruded type door stopper of double legged with rubber shoes in bottom complete all as specified and directed.
M & L For 100mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base of paver block complete all as specified and directed.
M & L for Machine pressed precast concrete coloured interlocking paver block glossy finish of 60mm thick any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cusioning complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for cement concrete Type B0 (1:2:4) using 12.50 mm aggregate as in edging portion of paver block for proper matching with existing surface complete all specified and directed.
Point wiring for one light/fan/bell/exhaust fan point/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size not less than 20mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed by Engr in Charge & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per srl item No 43.00 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl PVC conduit complete all as specified and directed.
All as per srl item No 43.00 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per srl item No 43.00 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified and directed.
Switch piano flush button single pole one way 15/16 amps 230 Volts complete all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
S & F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
S&F of wall mounted LED light fittings 20 watt, 6500K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically complete all as specified and directed.
Supply and fix of High power LED Wall Security light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as specified and directed.
S&F of LED light fitting recess mounted 36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly complete all as specified and directed.
S & F VTPN distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to complete with one MCCB 3 pole 415 Volts 100 Amps, 4 pole rating with rupturing cap 26 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion complete all as specified and directed.
Supply, fixing and testing ceiling fan, white colour Energy saver 1200mm sweep (not exceeding 40 watt), 230 volts single phase complete Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) alongwith Remote and down rod, adequate size of clamp, making electric connection with PVC rounded 3 core 1 sqmm copper cable from ceiling rose to ceiling fan connector, including writing MES No. in black synthetic enamel paint / engraving with tool complete all as specified and directed.
S&F 10 watt recessed LED Downlight complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.
Supplying and laying sub class 'B' bricks old size, size 230mm x 115mm x75mm complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core complete all as specified and directed.
PRATAPGARH CONSTRUCTION CO.
Allied Builders And Engineers
Khalil Ahmed and Sons
Khushi Muskan Engineer & Developer
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .