Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 LAccepted-Finance RZB 69 GALI NO 5 RAJ NAGAR PART 1 WEAT DELHI DELHI 110045 SOUTH WEST DELHI DELHI 110045 UDYAM DL 10 0018772 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-Finance Being lowest | |
| 2 | 2₹4.5 L+₹2,000 (0.45%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹4.5 L+₹7,000 (1.57%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹4.5 L+₹7,500 (1.68%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹46,000−₹4 L (89.7%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
Closing Date
22 Mar 2021, 9:00 amClosed
CWE
HQ CWE AGRA 112 TAJ ROAD AGRA CANTT
REPAIR OF LT PANELS AND XLPE HT UNDERGROUND CABLE 95 120 SQMM 3 CORE AT WAC LINE AND COD AGRA UNDER GE EAST AGRA
2021_MES_430787_1
3001/e-Qtn/24/2020-21/E3
Limited
Job Works
Item Rate
30 days
GE EAST AGRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
23 Mar 2021
15 Mar 2021
23 Mar 2021
16 Mar 2021
22 Mar 2021
16 Mar 2021
(a) S&F in repair drawnout type ACB having current ratings 1600 Amps with ruptuting capacity 50 KA, AC 415V, 4 Poles with neutral overload protection OFF 50% - 100% in built temp protection and rotational terminal for horizontal / vertical orientation complete with spreader links all as specified and directed including dismantling the existing u/s ACB with all connections and all as required at site and directed by Engr-in-charge. Make : Legrand Cat Pt No 6695 70 DMX SP 2500 or equivalent of L&T/C&S/ABB/Siemens. - 01 each (b) M&L for detecting the pin point fault of defective UG cable 95 sqmm (length approx 1100RM) by using HT megger detecting device and including testing using HT megger to clear the fault. - 01 Job (c) M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm complete including taking out old unsv cable jointing kit all as specified and directed. Make : 3M/Raychem/Densons - 03 each (d) M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm complete including taking out old unsv cable jointing kit all as specified and directed. Make : 3M/Raychem/Densons - 02 each (e) M&L in repair cable jointing kit for 11 KV (Earthed) grade cable indoor termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm including testing and commissioning and taking down old unserviceable cable jointing kit, complete all as specified and directed Make : 3M/Raychem/Densons - 03 each (f) M&L in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with alum conductor, 11/6.35KV grade, suitable for earthed system, with aluminum conductor, 3 core 95 sqmm including taking out old unsv cable jointing kit all as specified and directed.- 80 RM
(g) Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of poles/cable, stay assy etc and getting out any type of soil complete all as directed by Engr-in-Charge. - 31.00 cum (h) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layers complete all as specified and directed by Engr-in-charge. - 21.73 cum (j) Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 9.27 cum (k) Supply and laying dry river sand laid in trenches as cable cushioning 80mm below and 150mm above the cable and punned to 180mm and covering all as directed. Note : Punned qty will be measured and paid.- 6.50 cum (l) M&L un reinforced precast concrete cable cover, class HVP, type 1 with peak size 300mm x 180mm x 40mm laid over sand cushioning for mechanically protection of cable in trenches keeping width of brick parallel to the length of cable all as directed. - 444 each Note : Old retrieved unsv spares will be property of bidder and credit will be adjusted in the quoted rate.
H.B. Traders
J B Electricals
SM CONSTRUCTION COMPANY
MAHABIR SINGH
sheetal engineering
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
finance_481002.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .