Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹4.3 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹4.8 Cr+₹51.1 L (11.9%)Rejected-AOC | ₹4.8 Cr+₹51.1 L (11.9%) | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹5.1 Cr+₹77.5 L (18.1%)Rejected-AOC | ₹5.1 Cr+₹77.5 L (18.1%) | L3 | Rejected-AOC L3 Bidder |
| 4 | L4₹5.1 Cr+₹85.5 L (19.9%)Rejected-AOC | ₹5.1 Cr+₹85.5 L (19.9%) | L4 | Rejected-AOC L4 Bidder |
| 5 | L5₹5.2 Cr+₹93.7 L (21.9%)Rejected-AOC 404 ITL TWIN TOWERS PLOT NO B 9 NETAJI SUBHASH PLACE PITAMPURA NEW DELHI | NORTH WEST | DELHI | 110034 | ₹5.2 Cr+₹93.7 L (21.9%) | L5 | Rejected-AOC L5 Bidder |
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
23 Nov 2020, 6:00 pmClosed
CE R AND D DELHI
CE R AND D DELHI
UPGRADATION OF CENTRAL AC PLANT BER AC PLANT FOR NMR LAB AT INMAS DELHI UNDER GE I R AND D DELHI
2020_MES_349047_2
CE R AND D/DLI-03/2020-21
Open Tender
Civil Works
Item Rate
540 days
DELHI
Please refer tender documents
2 documents required · 2 mandatory
₹2,000
GE I RND DELHI
₹5.2 L
Yes
4 Jan 2021
8 Sept 2020
27 Nov 2020
8 Sept 2020
23 Nov 2020
2 Nov 2020
Amount
AIR CONDITIONING SECTION-I CHILLERS Supply ,installation,Testing and commissioning of AHRI certified Screw Water Chilling Machine each specified capacities hereunder, suitable for operation on refrigerant R-134a each comprising of the following complete as per specification and as required. The scope of work shall also include lifting, shifting and positioning of chiller at location shown on drawing with given in 1.2 (cell) here-in-after requirements:- Screw Water Chilling Machine each having a capacity of 302400 K.CAL/ Hour (100 TR) at chilled water inlet/ outlet temperature of 54 Deg. F (12.22 Deg.C) / 44 Deg. F (6.67 Deg.C) with chilled water circulation rate of 240 GPM (nominal) and condenser water inlet/ outlet temperature of 90 Deg. F (32.22 Deg. C)/ 100 Deg.F (37.77 Deg. C) with circulation rate 300 GPM (Actual) (2W+1S) Refrigerant - R - 134a Evaporator Fouling Factor: 0.0005 (British Units) Condenser Fouling Factor: 0.001 (British Units) Min. COP = 5.8 at AHRI conditioners Min IPLV = 7.1 at AHRI conditioners Maximum 1 KW/TR=0.68 Maximum Pressure Drop in evaporater- 6.5 mt Maximum Pressure Drop in condenser- 6.5 mt Each Chilling Machine shall also comprise the following :- (a) 1 No. Screw type compressor semi hermatic sealed complete single/multi circuit with automatic capacity control, safety switches, speed increasing gears, forced feed lubrication system etc. as per specificaitons. (b) 1 No. Suitable capacity squirrel cage induction motor with class 'F' Insulation suitable for operation on 415+10% volts, 50Hz, A.C. Supply. (c) 1 No. Star Delta Starter suitable for compressor motor complete with ammeter with CTs, overload protection, under voltage protection, protection against phase reversal & independent single phase preventors etc. complete as required. (d) Necessary Drive arrangement and other requirement as in given in Schedule ' A'. (e) And other notes and requirement of this item refer Note No 31 alongwith other notes on srl page No 22 to 25 of CA.
Chilled Water Primery Pumps Supply and fixing of factory designed, built, tested Vertilcal Inline Long coupled Pump with electric motor for re-circulation of water for the central air conditioning system for 240 GPM at 13 m head (2W+1S), be having rigid coupled protected by OSHA complaint coupling guard, with CI casing, Bronze (CF8) impeller, high strength steel shaft, the pump motor suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of IE3 efficiency class. Pumps shall have outside type mechanical seal and CI casing, Bronze Impeller & SS Shaft. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree fehrenheit. Minimum efficiency of pump shall be 70% for 907 LPM pump. The pump shall be designed for PN-16 pressure ratings and also comprises the following :- (a) 1 No. Vertilcal Inline Long coupled Pump (b) 1 No. Suitable HP, TEFC squirrel cage induction motor IE-3 with class 'F' insulations 1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply (c) Lot- Expanded polystrene (T.F. Quality) insulation of not less than 75mm thick duly cladded with aluminium sheets of 24 G thickness and properly clamped to pump in two semicircular seciton as per specifications. (d) Lot - Mounting frame work with anti vibration pads. (e) Sound level of pump shall not be more than 85 dBA at 1.5m distance for the following requirement.
All as per srl item No 2 above but 23.8 GPM of 20 m head (1W+1S).
Secondery Chilled Water Pump Supply and fixing of of factory designed, built, tested Vertilcal Inline Long coupled Pump with VFD drives & pump controller along with electric motor for re-circulation of water for the central air conditioning system. The pumps having rigid coupled protected by OSHA complaint coupling guard, with CI casing, Bronze impeller, high strength steel shaft, pump motor suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of IE3 efficiency class, Pumps have outside type mechanical seal and CI casing, Bronze Impeller & stainless steel shaft. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree fehrenheit. minimum efficiency of pump shall be 70%. The pump shall be designed for PN-16 pressure ratings, The variable speed package shall consist of Variable frequency drive (VFD) one for each pump and each VFD shall be pump mounted for unit reliability with build in DC Choke for 35%-40% harmonics. VFD Shall be capable of displaying operating Head and Flow for better and precise control. 1 No. microprocessor based pump controller housed with in the enclosure of one of the VFD, pump logic controller be enclosed in an IP54 protection enclosue and should not be mounted on the VFD for better reliability & redundancy. Controller shall come with pumping software duly downloaded & single / multiple differential pressure sensor / transmitters/ Sensorless controls for each secondary zone as per the site requirement.. The entire system along with secondary pumps must be sourced from pumping system comprises the followings :- (a) 1 No. Vertilcal Inline Long coupled Pump. (b) 1 No. Suitable HP, TEFC squirrel cage induction motor IE-3 with class 'F' insulations 1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply (c) 1 No. dedicated microprocessor based pump controller housed with in the enclosure of one of the VFDs with pumping software duly downloaded, control and control wiring etc. complete as required and shall be suitable for operation on 415 + 10% volts, 50 Hz, 3 Phase AC power supply. (d) Lot- Expanded polystrene (T.F. Quality) insulation of not less than 75mm thick duly cladded with aluminium sheets of 24 G thickness and properly clamped to pump in two semicircular seciton as per specifications. (e) Lot - Mounting frame work with anti vibration pads for the following head :- (i) 240 GPM at 26m head (2W+1S)
Condenser Water Pump Supply & fixing of factory designed, built, tested Vertilcal Inline Long coupled Pump with electric motor for re-circulation of water for the central air conditioning system 300 GPM at 24 m head (2 W + 1S). The pumps shall be rigid coupled protected by OSHA complaint coupling guard, with CI casing, Bronze impeller, high strength stainless steel shaft.The pump motor shall be suitable for 415± 10% volts, 50 cycles, 3 phase AC power supply of IE3 efficiency class. Pumps shall have outside type mechanical seal and CI casing, Bronze Impeller & stainless steel Shaft. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree fehrenheit. minimum efficiency of pump shall be 70%, pump having designed for PN-16 pressure ratings conprises the followings:- (a) 1 No. Vertilcal Inline Long coupled Pump (b) 1 No. Suitable HP, TEFC squirrel cage induction motor IE-3 with class 'F' insulations 1450 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply (c) Lot - Mounting frame work with anti vibration pads. (d) Sound level of pump shall not be more than 85 dBA at 1.5m distance.
COOLING TOWERS CTI Approved Supply, installation, testing and commissioning of 125 TR (2W + 1S) of FRP induced draught type colling towers of following capacity each complete with FRP basin having and auxiliary rectangular suction tank at the bottom. the basin shall be complete with connections for drain, overflow, makeup water, quick fill and float valve, plus hot dipped galvanized suction strainer FRP body, of sufficient strength to with stand wind velocities upto 60 m/s , vibrations and earth quakes, fan and motor assembly conforming to IP-55, protection for outdoor operation fill media honeycomb design arranged in the suitable pattern for ease of replacement, distribution pipes consisting of PVC sprinkler pipes mounted on top of the main supply standby, sprinkler head mounted on ball bearings designed to take both radial and vertical thrust overflow pipe, ladder, vibration isolation pads, cables, controls etc. As per specifications and drawings. Ambient temperature. Summer 110 ⁰F DB, 75 ⁰F WB Monsoon- 95 ⁰F DB, 83 ⁰F WB. WB approach 7 ⁰F. Inlet temperature of Condenser- 90 ⁰F Outlet temperature of Condenser- 100 ⁰F.
HOT WATER GENERATOR M&L for Providing and installing electrically operated Hot Water Generator of nominal capacity 75 KW having 10mm thick shell of mild steel sheet, 12mm thick dish end of mild steel sheet, 1mm thick stainless steel lining with heaters arranged in banks and controlled by electronic controller and thermostats so that following flow rate hot water at 70° C and with nominal variations could be supplied including 75mm thick fibre glass / mineral wool / insulation finished with 1.25mm thick G.I. sheet clading including necessary electrical panel board, having suitable incoming & outgoing switch gears for boiler and pump automatic controls including inlet and outlet connections for water, along with pressure relife valve, drain valve, safety valve gauge pressure, switch & safety hutton foundation for boiler as per specifications complete as required. (2W+0S) and as directed.
AIR & DIRT SEPARATOR Supply installation testing and commisioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300). complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the release of micro-bubbles and dirt to the surfaces. Epoxy resin coated steel body. Brass automatic air vent valve body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals. Medium water and non-hazardous glycol solutions excluded from the guidelines of EC directive 67/548; maximum percentage of glycol 50%. Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5µ. Working temperature range 0–100°C. Floor brackets for line size 150 mm diametre complete all as specified and directed.
ONLINE-WATER SCALE PREVENTER Supply, installation, testing and commissioning of Scale Preventer in the condenser water circuit to prevent scale formation, unit should be a non-chemical on line-type, outer casing shall be made of seamless stainless steel, pump, valve, electrical etc for 480 US GPM complete all as specified and directed.
INTEGRATED PLANT ROOM OPTIMIZER : Supply, installation, testing and commissioning of Plant System Optimizer Plant System Optimizer software package with :- Chiller Plant Workstation: Tower Server Grade with Intel® Xeon® E5 2600 v3 processors (Latest Technology) , Window® Server 2008SP2 operating system , 1 TB HDD, 8GB RAM, Enhanced graphic card, DVD Combo Drive, Ethernet Port with 32” color monitor flat screen LED display, multimedia keyboard & optical mouse and Microsoft office 2013 and anti virus as per specification – 01 Lot Workstation Software: BTL Listed Web Based Graphical interface software for plant optimizer . The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocols shall be one of the industry standard open protocols such as BACNet , Modbus & Lonworks etc. Software should be scalable & no extra communication driver license required shall be acceptable with unlimited point capacity. Software shall have customizable dashboards for energy management. Software shall have 3 concurrent user license with upgradable to unlimited web user license. Software shall have energy management feature with reporting option – 01 Nos Network Supervisor: SITC of Network Automation Server BTL/UL listed Required Gateway for integration of DDC controllers. Standard open Protocols such as BACNet , MODBUS, Lonworks etc having high memory of min 500 MB and processor of min 500 MHz. DDC controller shall have battery backup for at least 10 days. Gateway shall have 2 nos 10/100 Ethernet ports, 2 nos RS-485 communication port. Gateways shall be DHCP enabled & have an option of creating white listing I/P for cyber security. Direct Digital Controllers: SITC of Standalone BTL & UL listed Net I/P field DDC controller having universal input/ output ports. Controller shall have 2 10/100 Ethernet port & can communicate in Star, Daisy Chain , RSTP topology & offer path redundancy for communication . DDC controller shall be DHCP enabled to ensure VPN network. (1 AHU per DDC). All DDC controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosures shall house the terminal blocks, load relays and associated equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics - 01 Lot Network Switches: Supply, installation, testing and commissioning of layer 2 managed gigabit switch. The switch shall have RSTP enabled ports to communicate with other switches to built a opology network with redundancy on CAT6 armourded UTP cable within the building complete as per specification and as required for BMS DDC Panel Networking. L2 24 Port Switch – 02 Nos
Field Devices Supplying, installing, testing and commissioning of the following Field Devices complete all as specified and as per manufacturers instructions. Imerssion Tempreture Sensor - 12 Nos Immersion type Electromagnetic Flow meter -05 Nos Ambient type T + RH Sensor - 01 Nos DP Switch Water - 13 Nos Water pressure transmetter - 03 Nos Single Level switch - 03 Nos Differential pressure switch - Air - 07 Nos Wall mounted temp sensor - 07 Nos
Supply, laying & testing 2 Core X 0.8 Sq.mm Annealed Tinned Copper Conductor, 1100 volt PVC Insulated, armoured (0.9 mm.) PVC Sheathed Signal Cable as on wall, floors, ceiling, columns, duct etc complete all as specified and directed.
Supply, laying & testing 3 Core X 0.8 Sq.mm Annealed Tinned Copper Conductor, 1100 volt PVC Insulated, armoured (0.9 mm.) PVC Sheathed Signal Cable as on wall, floors, ceiling, columns, ducts etc complete all as specified and directed.
Supply, laying & testing 2 Core X 0.8 Sq.mm Annealed Tinned Copper Conductor, 1100 volt PVC Insulated, armoured (0.9 mm.) PVC Sheathed Power Cable as on wall, floors, ceiling, columns, ducts etc complete all as specified and directed.
Supply, laying & testing 3 Core X 0.8 Sq.mm Annealed Tinned Copper Conductor, 1100 volt PVC Insulated, armoured (0.9 mm.) PVC Sheathed Power Cable as on wall, floors, ceiling, columns, ducts etc complete all as specified and directed.
Supply, laying & testing 2 Core X 0.8 Sq.mm Annealed Tinned Copper Conductor, 1100 volt PVC Insulated, Shielded, armoured (0.9 mm.) PVC Sheathed Communication Cable as on wall, floors, ceiling, columns, duct etc complete all as specified and directed.
Supply & fixing CAT 6 cable for networking complete all as specified & directed.
Supplying, laying and fixing GI Cable perforted Tray & GI raceways with all accessories complete all as specified & directed.
Horizontal Floor Mounted AHU-6: 11200 CFM at 85 mm static pressure (23.87 TR & fresh air 627CFM).
Horizontal Floor Mounted AHU-7: 6700 CFM at 85 mm static pressure(28.15 TR & fresh air 2238CFM).
Horizontal Floor Mounted AHU-4: 12700 CFM at 85 mm static pressure(36.20 TR & fresh air 2050CFM).
Horizontal Floor Mounted AHU-2: 13500 CFM at 85 mm static pressure(24.53 TR & fresh air 855CFM).
Horizontal Floor Mounted AHU-1: 7900 CFM at 85 mm static pressure (20.94 TR & fresh air 545CFM).
Horizontal Floor Mounted AHU-3: 12000 CFM at 85 mm static pressure. (16.44 TR & fresh air 137CFM). Note: for ser item 20.1 to 20.6. (a) All AHUs to operate with VFD, VFD package shall be supplied by AHU manufacturers. (b) Space provision shall be kept inside AHU for heat pipe.
HEAT PIPE Suppy, install, testing and commissioning of Heat pipes for enhanced dehumidification (Horse shoe - wrap around the main cooling coil) as per specification. The working fluid shall be refrigerant R410a / R134a. Heat pipes shall be designed to comply with the specified conditions when subject to the air volumes given in the specification. The heat pipe shall be sized using the validated software generated from testing done inline with AHRI 1060. Minimum 3 RD Coil having face velocity shall not more than 500 FPM and pressure drop shall be not exceed 12 mm WG. Co-ordination with chosen AHU manufactorer to finalise the AHU section, coneection and maintenance provisions. Heat Pipe supplier should include price for HEAT PIPE installation and coordination with AHU VENDOR for a) Slot Provision in AHU for Heat Pipe installation b) Installation of Heat pipe in coordination with AHU vendor c) Commissioning of Heat pipe along with AHU Basis of design 100% Fresh air (TFA) or Recirculation AHU ----> Recirculatory AHU Ambient conditions required for the follwing parameter for Heat pipes (DB/WB) Summer :- 43.3 °C (DB ), 23.9 °C (WB) Monsoon :- 35.0 °C (DB ), 28.3 °C (WB) Off coil temp. of AHU - 11.5 °C Desired temp. & RH Room - 20-22 °C , 55% RH The above conditions are required to achieve follwing CFM:- Total 25700 CFM, Fresh air- 613 CFM
Total 11200 CFM, Fresh air- 627 CFM
Total 6700 CFM, Fresh air- 2238 CFM
Total 12700 CFM, Fresh air- 2050 CFM
Total 13500 CFM, Fresh air- 855 CFM
Total 7900 CFM, Fresh air- 545 CFM
Total 12000 CFM, Fresh air- 137 CFM
IAQ MONITORING UNIT FOR AHU Supply, installation, testing and commissioning of latest generation digital display type BMS compatible Indoor Air Quality (IAQ) Monitoring Unit to monitor and display PM 2.5 VOC, CO2, etc for various air handling units for return air. Monitor shall be rated for continuous operation, in indoor ambient -4EF to 140EF (-20E to 60EC) and RH 0 to 100% non condensing. All parts and components of the Monitor shall be housed in one neat, compact, 18 G CRS powder coated satin finish enclosure. Display unit shall be mounted inside/ outside the AHU room,. Unit shall capable display data in LCD screen complete all as specified and directed.
DUCT MOUNTED UGVI SYSTEM Supply, Installation , testing , commissioning and handing over of the DUCT MOUNT Ultra Violet Germicidal Irradiations (UVGI) System for maintaining indoor Air Quality , The lamps shall be minimum 3,000 μwsec/cm² . The components of the system must be in strict conformity with the specifications. The prices to include all inter connected wiring between the UVGI Lamps.( The UVGI Equipment shall be listed to UL 1995, and certified for Smoke and Fire Safety to UL 2043.) complete for the duct of the following AHU:- 25700 CFM
AHU COIL MOUNTED UVGI Supply, installation, testing and commissioning of AHU mountable self contained and factory assembled UV System with UL 1995 ABQK listed and UL 2043 certified, UV lamp life shall not be less than 11000 hours. Unit shall be installed in all floor mounted AHUs as specified herein. All the component / parts shall comply with the specification given in the tender.AHU shall have 600 mm length in additional as UVGI Section for fixing of UVGI System in all floor mounted for the following AHU:- 25700 CFM
ULTRASONIC HUMIDIFIRE Supplying, Installing, Testing and Commissioning of Ultrasonic humidifier of capacity 5 LPH, complete with stainless steel tank with float valve, water makeup, overflow and drain connections. The transducer shall be interlocked with float switch supplied with humidifier and humidistat with necessary supports by MS structural steel if required, hangers. MS Clamp supports from walls, floors and ceiling including applying two coats of synthetic enamel paint over one coat of red oxide zink chrome primer on MS work complete all as specified and directed.
PIPING Supplying, laying/ fixing, testing, commissioning and refilling of soil of following nominal sizes of burried chilled water piping carried out of preinsulated MS class 'C' pipes as per IS-1239 for pipes upto 150mm NB and as per IS-3589 for 200mm NB and above as per specifications and the insulation should be complete as follows. Pre-insulated pipes with PUF insulation & HDPE Jacketing thickness 5mm:- 150 mm dia MS pipes with 75 mm insulation alaround.
125 mm dia MS pipes (50 mm insulation)
80 mm dia MS pipes (50 mm insulation) alround
65 mm dia MS pipes with (50 mm insulation) alaround
100mm dia MS pipe with (50mm insulation) alaround. Note:- For ser item No 25.1 to 25.5. (i) The pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 made from minimum 6.35mm thick M.S. Sheet. (ii) Excavation and earth work shall be measured and paid seperatly under respective items of BoQ.
Chilled Water Piping Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary MS clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated PUF moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade I roofing feltstrip(as per IS:1322 and amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete for the following sizes of pipes:- 150 mm dia MS pipes with (75 mm insulation) alaround.
125 mm dia MS pipes with (50 mm insulation) alaround
80 mm dia MS pipes with (50 mm insulation) alaround
65 mm dia MS pipes with (50 mm insulation) alaround
50 mm dia MS pipes with (50 mm insulation) alaround
100 mm dia MS pipes with (50 mm insulation) alaround
Drain Piping Supply,installation,testing and commissioning of "B" class GI drain piping complete with fitting etc & 25 mm thick PUF insulation with sealing tapes & 28 gauge Aluminium cladding for 80mm dia size pipe complete as per drawings and specifications.
Supply, fixing testing & commissioning of or BUTTERFLY VALVE (MANUAL) with C I body Stainless steel Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot heater circulation duly insulated for child water plumbing as specified to suit the pipes of following sizes :- 125 mm dia
80 mm dia
65 mm dia
50 mm dia
Supply, fixing testing & commissioning of BUTTERFLY VALVE (Motorized ) with C I body Stainless steel Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot heater circulation duly insulated for chilled water plumbing as specified to suit the pipes of the following sizes :- 125 mm dia
65 mm dia
Supply, fixing testing & commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation duly insulated for chilled water plumbing as specified suitable to pipes of the following sizes :- 125 mm dia
80 mm dia
65 mm dia
50 mm dia
Supply, fixing testing & commissioning of NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation for chilled water plumbing as specified suitable for the following sizes of pipe dia:- 125mm dia
50 mm dia
Supply, fixing testing & commissioning of Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified to suit the following sizes of pipe dia :- 125mm dia
80 mm dia
65 mm dia
50 mm dia
50 mm dia
Supply, fixing, testing & commissioning of Bellows type rubber expansion joints for Chilled water piping located at Pump inlet & exit, AHU inlet & exit, AHU inlet & exist and at chiller inlet & exit.. Complete with double bellows, tie rods, MS flanges, necessary hardware and gaskets etc. with insulation of size 125mm.
80 mm dia
65 mm dia
50 mm dia
Supply, fixing testing & commissioning of electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum for the follwing sizes:- 80 mm dia
65 mm dia
50 mm dia
M & L for providing and fixing in position the industrial type pressure gauges with Stainless Steel grade-304 valves complete as specified and directed.
M & L Providing & fixing in position the mercury in glass industrial type thermometers complete all as specified and directed.
Supply,installation,testing and commissioning of proportional type cooling and heating thermostats for the various Air Handling Units complete with required control wiring/installation kit etc all as per drawings and specifications.
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary M. S clamps, vibration isolators and fittings such as bends, tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/ buried in ground excavation and refilling etc. as per specification and as required complete in all respects for the folliwng sizes:-. 200 mm dia pipe.
150 mm dia pipe.
50 mm dia pipe.
25 mm dia pipe. Note:- For ser item of 39 to 39.3. (i) The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia.
Valves without Insulation. Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) with C I body stainless steel disc nitrile sheet & O - ring & PN 16 pressure rating without insulation for condenser water circulation complete all as specifiedto suit the follwing sizes of pipes:- 200 mm dia.
150 mm dia.
50 mm dia.
25 mm dia. (Ball Valve)
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (Motorized ) of 150mm dia size with C I body stainless steel Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation complete all as specified fand directed.
Supplying, fixing, testing and commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY of 150mm dia size with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation complete all as specified and directed.
Supplying, fixing, testing and commissioning of NON - RETURN VALVE of 150mm dia size with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating complete all as specifiedand directed.
Supplying, fixing, testing and commissioning of Y - STRAINER of 150mm dia size of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation complete all as specified and directed.
Supplying, fixing, testing and commissioning of Bellows type rubber expansion joints for condenser water piping located at Pump inlet & exit and at condenser inlet & exit. Complete with double bellows, tie rods, MS flanges, necessary hardware and gaskets etc with insulation suitable for 150mm dia pipe complete all as specified and directed.
Supply, fixing, testing & commissioning of Self Cleaning Pot Stainner Cum Sediment Separator fabricated out of MS IS 226 with SS 304 filter element at outlet of Cooling Tower suitable for 200 mm dia pipe complete all as specified and directed.
Supply, installation, testing and commissioning of 10mmdia. Automatic air vent in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent complete all as specified and directed.
Supply, Installation, Testing, & Commissioning of 25mm diameter Plug valves in dirt legs complete with nipples etc. as required complete all as specified and directed.
M&L for Providing and fixing in position of approved make differential pressure switch of brass body complete with copper control wiring at condenser and chiller outlet of each machine complete all as specified and directed.
PART- D : AIR DISTRIBUTION SYSTEM Sheet Metal Duct Supply,assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L'shaped hollow profile ,duly factory boxed including all accessories such as Corner ,Cleat,Carriage bolt,Gasket and appropriate sealant on longitudinal joints etc complete as per drawings and specifications for the following thickness :- GI Sheet of size 24 Gauge.
GI Sheet of size 22 Gauge.
GI Sheet of size 20 Gauge.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, complete all as specified and directed.
Supplying & fixing duly powder coated not less than 50 micron thick on extruded aluminium supply Air Grills with aluminium volume control dampers complete all as specified and directed.
Supplying & fixing duly powder coated paint not less than 50 micron thick on extruded aluminium Return Air Grills with louvers but without volume control dampers complete complete all as specified and directed.
Supplying, fixing & testing commissioning of supply air diffusers duly powder coated paint not less than 50 micron thick on luminium with aluminium volume control dampers with anti smudge ring & removable core all as specified and directed.
Supplying, fixing & testing commissioning of Return air diffusers duly powder coated paint not less than 50 micron thick aluminium without volume control dampers with anti smudge ring & removable core complete all as specified and directed.
Supplying, installing and testing of fresh air GI intake louvers with VCD, bird screen and carbon filter complete all as specified & shown on drawings.
Supplying, fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as specified as under :- Fire Damper.
Fire Actuator.
Supply and fixing acoustic lining of supply air duct and plenum with 15 mm thick Open Cell engineered Nitrile Rubber foam of density 140-180 kg/cu.m with in built Microban and tested as per ISO 354:2003, ISO 11654:1997 and ASTM C 423 etc., complete as required and all as specified.
M&L for Providing and fixing of acoustic lining on wall and ceiling of AHU rooms with 25mm thick Rigid Board of Glass wool one side aluminum faced and other side black glass cloth lamination, density 70 to 80 kg/cu.m complete all as specified.
M & L for 50mm thick duct insulation with resin bonded fibre glass wool roll of density 24 Kg /Cum and 40mm thickness with factory laminated aluminium vapour barrier , thickness of insulation as specified and including as per following requirement :- (a) Cleaning the duct surface( to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale ,dirt,dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon / steel straps of size 12mm / 50mm at maximum intervals of 1.2 mtr.
Isolators Supply & fixing, testing and commissioning of Lockable 40 Amp, 4 pole isolator box in powder coated MS enclosure suitable for wall mounting and floor mounting with provisions of incoming and outgoing cables. The protection class of the Isolator Box shall be IP-55 & the rating complete all as specified and directed.
All as per item 65.1 here-in-before but 63 Amp 4 poles.
Cable Supply, Laying, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid on walls, ceiling, floor, trenches duct etc for the following sizes :- 4 Core x 6 Sqmm (copper) for chilled water primary pumps
4 Core x 10 Sqmm (copper) for Cooling Towers
6 Core x 16 Sqmm (copper) for Secondry Chilled water pumps, Condensor Water Pumps & AHUS
3.5 Core x 95 Sqmm (aluminium) for hot water generator
3.5 Core x 120 Sqmm (aluminium) for chiller
6 Core x 1.5 Sq.mm (copper) Note :- For ser items No 66 to 66.5. (i) Excavation & earth work , sand cushion, protection cover if required shall be measured and paid separately under respective item of BoQ
Material and Labour for earthing complete as shown in electical plate No 3 with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cm of earth plate. GI plate connected with galvanised iron strip of 32x6mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm internal dimension constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC 1 :2:4 type B0 reinforced with 8mm dia deformed bars @100 mmc/c bothways pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
M & L for Earth continuity conductor or main earthing lead 32 x 6mm glavanised iron strips fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. including necessary excavation and earth work if any required at site in soft/loose soil and removal of surplus spoil to a distance up to 50 m
All as per item No 68 here-in-before but 8SWG Wire
Cable Tray Supply, fabricating and installing of perforated M.S. cable trays of size 50x 450 x 50mm made of 2mm thick sheet including horizontal and vertical bends, reducers, tees, cross members and other accessories of mild steel as required, and duly suspended from the ceiling with M.S. suspenders, including painting with two coats of synthetic enamel paint over one coat of red oxide zinc primer complete all as specified and directed.
All as per item No 70 above but 50 x 300 x 50 mm of 2 mm thick
All as per item No 70 above but 50 x 150 x 50mm of 2 mm thick
Supply and fixing passing through ducting /tranches as site requirment insulated screened PVC bedded, galvanized steel strip or wire armoured under ground cable heavy duty 1100 volts grade with stranded aluminium conductor including taking down , cross sectional area 300 Sqmm 3.5 core .complete all as specified & directed at site. Note:- Excavation, earth work, protection cover and sand cushion shall be measured and paid seperatly.
Supply and fix ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps at existing LT panels complete all as specifed and directed.
Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA at existing LT panels all as specifed and directed.
S&F GI steel tubing medium grade galvanised 25mm bore with all accessories/ fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed. Note : The aspect of cutting chases for concealed pipes and fittings etc wherever required and making good, disturbed surfaces in CM 1:3 shall be deemed to include in the unit quoted rate.
M&L for river screened sand filling for cushion of underground cable with layer of sand 8 cm deep before laying and 15 cm deep after laying of cables complete all as specified & directed. Note : Punned down thickness will be considered for payment of sand cushion of cables
M&L for bricks having compressive strength not less than 75 kg/sqcm laid dry for protection of cables laid in trenches complete all as specified and directed.
Supply and laying GI pipe light grade in replecement of 80mm dia laid in trenches for protection of under ground cable complete all as specified and directed.
INTERNAL ELECTRIFICATION (SECTION)-II Taking down unserviceable point wiring any type for light, fan, power etc including unserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls ,floors roof etc with existing surfaces complete
M&L for Point wiring with 2 single core 1.5 Sqmm multistranded copper conductor cable multistranded, FRLHS PVC insulated and unsheathed in and including non metallic PVC concealed connduit 20 mm bore dia with necessary fitting including cutting chasing for conduits and terminal boxes of GI having thickness 2.00mm with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected to common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and directed.
All as per ser item No 81 here-in-before but using for one 5 pin switch socket out let on independent board.
Material & labour for point wiring for one light point or one fan/exhaust/bell point controlled by one switch with using 1.5 Sqmm(nominal area) stranded copper conductor , two single core, PVC insulated & unsheathed cable FRLSH 1100 Volts grade in existing concealed conduit as directed with terminal boxes 2mm thick GI Sheet suitable for modular fitting including accessories as modular surface cover plate with frame and using 1.5 Sqmm (nominal area) stranded copper conductor single core PVCinsulated & unsheathed FRLSH cable as in earth wire connected to earth dolly complete all as specified and directed.
All as per srl item No 83 here- in- before but 3 pin socket outletout 5 Amps on independent board.
All as per srl item No 81 here- in- before but using cable size 4.00 Sq mm with earthwire of size 4.00 Sq mm for one three pin switch socket outlet 15/16 Amps point with terminal boxes made out of GI sheet 2 mm thick.
All as per ser item No 83 here-in-before but on existing concealed conduit and using cable size 4.00 Sq mm with earth wire of size 4.00 Sq mm for one three pin switch socket outlet 15/16 Amps point with terminal boxes maade out of GI sheet 2 mm thick.
S&F modular switch 6 Amp single pole one way-1 module (Cat No 574800 of Legrand or equivalent in as mentioned in Appx 'B' to PS.
S&F modular switch 15/16 Amp single pole one way-1 module (Cat No 574808 of Legrand or equivalent in as mentioned in Appx 'B' to PS.
S&F modular socket outlet shuttered-6A-2/3Pin-universal India 2 Module complete. (Cat No 574833 of Legrand or equivalent in in as mentioned in Appx 'B' to PS.
S&F modular socket outlet shuttered-6/16A-2/3Pin Indian 2 Module complete. (Cat No 574834 of Legrand or equivalent in as mentioned in Appx 'B' to PS.
M&L for Modular Bell push 6 Amp 2 Module (Cat No 574824 of Legrand or equivalent in as mentioned in Appx 'B' to PS.
M&L for Bell multi music type complete.
M&L for Ceiling rose surface backlite, 65mm x 50mm complete all as specified.
S&F Telephone socket RJ11 with shutter.
S&F in replacement of Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic diver.trica batten 230 volt, 50 Hz, 22 watt and twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose complete all as specified and directed . Make Havells Cat part no-ENDURALINEARNEOBS22WLED865SPCWH or equivalent in phillips/Wipro.
S&F in replacement of LED Recess mounted pressure die-cast aluminium luminaire in powder coated white finish with drop down PC diffuser with optimized heat sink for efficient heat dissipation and separate replaceable electronic diver 230 volt, 50 Hz, 15 watt, including and twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose, alongwith necessary alteration work in false ceiling to cover the blank space in false ceiling complete all as specified and directed . Make Havells Cat part no RISEDLR15WLED840S or equivalent in Wipro /phillips.
S&F in replacement of unseviceable CFL light to new LED recess mounting panel 2'×2' fitting 42 watt and making all electric connections including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose alongwith necessary alteration work in false ceiling to cover the blank space in false ceiling complete all as specified and directed. Make- PLUTONEO2X2PLR42WLED857S of make Havells or equivalent in Wipro/Phillips.
S&F in replacement of linear & compact LED mirror light 9 watt, including cable for making circuit and 9 watt LED tube complete and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose all as specified and directed by Engr-in-Charge.Make CAT PART NO-LUMILINEBS9WLED865SPCWH of Havell or equivalent in Wipro/Phillips.
S&F LED surface mounting panel 2'×2' fitting 36W and making all electric connections and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose after taking down old CFL complete all as specified. Make-PLUTOSURFACE2X2PLS42WLED857S of' Havells or equivalent in Wipro/Phillips.
S&F LED surface mounting panel 1'×1' fitting 15 W and making all electric connections and alongwith twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose after taking down old CFL complete all as specified. Make-PLUTOSURFA CE1X1PLS15WLED857S of' Havells or equivalent in Wipro/Phillips.
Supply and fixing in replacement of SPN DB 8 ways with 200 amps rated busbar 240 volt double door complete.
Supply and fixing in replacement of TPN DB 8 ways with 200 amps rated busbar 415 volt double door complete.
M&L for MCB single pole 6-32 Amps C Curve 240 Volt. (Make Legrand or equivalent in Havells/L&T)
M&L for MCB single pole & Neutral 63 Amps. C Curve 240 V (Cat No 408620 of Legrand or equivalent Havells/L&T)
S&F in renewal of sheet metal enclosure, SPN type with two pin and earth plug and socket industrial type DB with and including one MCB, SP 'C' curve type of capacity 25 Amp, 10 KA complete all as specified and directed.
Supply and fixing in replacement of triple pole and earth enclosure with a three pin and earth plug with socket complete with one tripple pole MCB 63 Amp, 415 Volts complete all as specified and directed. .
M&L in replacement of sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 16 Sq mm and two run of 16 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including non metallic rigid PVC conduit 32 mm dia complete all as specified and directed.
M&L in replacement of sub main wiring with Four run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and two run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including non metallic rigid PVC conduit 25 mm dia concealed complete all as specified and directed.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn into existing surface PVC conduit concealed surface type complete all as specified and directed.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including non metallic rigid 25 mm dia PVC conduit concealed complete all as directed.
Supply and fix in replacement of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. Complete all as specified & directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cm of earth plate. GI plate connected with galvanised iron strip of 25 x 4mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm internal dimension constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC 1 :2:4 type B0 reinforced with 8mm dia deformed bars @100 mmc/c bothways pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40x40x4 mm for 30x30 cm PCC pit for holding the pit cover. (e) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip all as specified and directed. Note:- In case excavation & earth work if required, then same will be measured and paid separately under relevent items of BOQ.
Taking down of Celling fan 1200/1400 mm sweep carefully and deposited in safe custody and refixing the same after painting with synthetic enamel white paint by spraying machine, including ,greasing,minor repairing before fixing on location all as specified and directed.
All as pe ser item No 114 here-in-before but exhaust fan of size 300/450mm sweep
B/R (PORTION) SECTION-III Demolition of plain cement Concrete in ground floors and poving n.exc 15 cm thickness (below or above ground level) and including removel of debris and rubbish out side defence land complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided removal debris and rubbish from out side defence land complete all as specified and directed
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons skirting etc laid bedded and pointed in any mortar and including removal from the out side defence land with mortar complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish including tiles outside MoD land complete all as specified and directed .
M&L for providing and laying in alternate panel 50 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in flooring /path etc finished even and smooth surface without using extra cement complete all on specified and directed.
M&L for 16 to 18 mm thick machine cut kota stone slab of size 550mmx550mm laid as in flooring, tread / landing laid over and including 20 mm thick screed bed or bedding layer in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of slab including necessay grinding, rubbing, rounding to exposed edges with moulding and polishing in granite finish complete all as specfied and directed.
M&L for 25 mm thick plain cement concrete (1:2:4), type B0 (using 12.5mm graded stone aggregate) as in sub floors and sub base floors to receive floor topping, complete all as specified and directed .
M&L for providing Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm first quality coloured of grade B II (a) /B II (b) and of abrasion reistance PE-I-III or above laid in floors, set and jointed in neat cement slurry and pointed in coloured cement to match tile over and including 20 mm thick rendering in CM (1:6) complete all as specified and directed .
M&L for italic or glasika colour tile & pattern (glass mosiac tiles), size 20mm x 20mm x4mm fixed over 2 to 3mm thick nitotie grout pressed with rubber trowel to remove excess grout with damp sponge and subsequently with dry rag complete and all as specified and as directed.
Demolition of brick work or stone boulder masonry, built in cement mortar all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles including removal from the site complete all as specified and directed.
M&L for brickwork with fly ash old size bricks having compressive strength not less than 75 Kg/Cm2 straight or curved on plan exc 6m mean radius, built in cement mortor (1:6). complete all as specified and directed .
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal fo debris and rubbish out side defence land complete all as specified and as directed .
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as specified and directed.
M&L for preparation of new plastered undecorated surfaces of walls and applying two coat of oil bound distemper over one coat of primer and including wall caré putty not less than 2mm thick, on plastered surfaces, complete all as specified and as directed .
M&L for applying two coat of oil found distemper over one coat alkali resistant primer on old surfaces of walls, including projections etc after complete removal of existing treatment and washing scrubbing down and stopping of existing treatment and making the surface even and smooth by applying layer of wall care putty not less than 2mm thick for distemper complete all as specified and directed
M & L for applying two coats of white wash after preparation of on old decorated surface of ceilling' complete all as specified and directed
M&L for providing Glazed coloured design ceramic tiles 300X 200X 7mm thick super glossy 1st quality of grade B tiles on vertical surfaces such as skirting /dado etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10 mm thick screed in CM (1:4) complete all as specified and directed .
M&L for laying anti skid ceramic tiles 8mm thick coloured design (square /rectagular) area of each tile exc 0.11 sqm but n exc 0.18 sqm first quality coloured of grade B 11(a) /B 11(b) and of abrasion reistance PE-I-III or above in floors set jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 15mm thick screed bed of CM (1:4) complete all as specified and directed .
Taking out or down old steel rolling shutter size 3m x 4.5m complete all as specified and directed.
Taking down old shutters of any description exc 1 sqm but n exc 2 sqm each including builders hardware fittings complete all as specified and directed.
S&F 30 mm thick factory made flush shutter, conforming to IS 2002(Part-I) solid core construction with block board core and ply wood face panels, commercial type on both sides with teak wood lipping 6mm thick and 40mm wide all around to the shutter complete all as specsified & directed.
M&L for preparation of new wood or wooden based surfaces of any description, over 10 cm in width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Taking down chowkhats or frames wooden/steel/aluminium not exc 1.5 sqm with shutter(without taking of shutter from the frames) including taking out hold fasts and PCC block removal from the site complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawings shown on ser page No 160 of SSR Part-II (Rates)
Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing as shown on ser page No 161 of SSR Part-II (Rates)
S&F stainless steel sliding door bolts with hasp, staple of size 300mm long and dia of shoot not less than 12mm of AISI 316 grade complete all as specified and directed
S&F stainless steel barrel tower bolts, size 200mm and dia of shoot / bolts not less than 10mm of AISI 316 grade complete all as specified and directed
S&F stainless steel handle, size 150mm of AISI 316 grade complete all as specified and directed
M&L for preparation of new previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
Taking down 15mm bore steel water tubing and connections from any position including removing from site complete all as specified and directed.
All as per srl item No 145 here-in-before but 20 mm bore dia.
All as per srl item No 145 here-in-before but 25 mm bore dia.
Screwing existing steel tubing 20mm bore for alterations or additions (or lengthening screw on pipe to form connector) in position. Complete all as specified and directed.
Screwing existing steel tubing 25mm bore for alterations or additions (or lengthening screw on pipe to form connector) fixed in position complete all as specified and directed.
S&F GI steel tubing medium grade galvanised 15mm bore with all accessories/ fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed. Note : Cutting chases aspect for concealed pipes and fittings etc wherever required and making good, disturbed surfaces in CM 1:3 shall be deemed to be included in the unit quoted rate.
All as per srl item No 150 here-in-before but 20 mm bore dia.
All as per srl item No 150 here-in-before but 25 mm bore dia.
Dismantling old unserviceable PVC water storage tanks of capacity exc 500 ltrs & but n.exc 1000 Ltrs including supplying & fixing of coloured PVC water storage tank 1000 ltr capacity HDPE, IS-12701 marked triple layered , cylindrical vertical type fixed and hoisted in position on roof upto 3 storey heigh building complete with inlet/outlet of 25 mm outer dia 3 layer PPR pipe connection including closed top with locking arrangement, including supplying & fixing Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight of valve 210 gms ) complete all as specified and directed by Engineer-in-Charge Note : ( Inlet, outlet & wash out pipe will be measured and paid separately.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe of 20mm bore dia complete and fixed all as specified and directed by Engr-in-charge.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes coupling; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed .
S&F in repairs Vitreous China wash basin, white, flat back, size 550 x 400 mm including PVC waste pipe, chain and plug and porcelain stopper, CP waste fitting 32mm dia and PVC bottle trap etc complete all as specified and directed.
S&F in repairs Vitreous China white wash down water closet pan (pedestal pattern), size 520x360x390mm including fixing bolts, PVC seat cover with mild steel chromium plated hinges (excluding flushing cistern and flush pipe ) complete all as specified and as directed .
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 ltr capacity, low level white with inlet ball valve, float, ,handle and brackets including fittings flush pipe 32mm bore complete all as specified and directed . Make:- Super Special colour of CERA CIENA PREMIUM Cat No B1010102 or equivalent in Jaquar
S&F in repairs bib taps long body chromium plated cast copper alloy half turn fancy type with crutch or butterfly handle screwed down suitable for iron pipe or brass ferrule of 15 mm bore complete all as specified and directed . Make :-Jaquar cat No FLR-5047N or equivalent in CERA
S&F in repairs pillar tap fancy type half turn long body push type time duly screwed for iron pipe and fixed 15mm dia bore complete all as specified and directed . Make :- Jaquar cat No FLR-5015 or equivalent in CERA
S&F in repairs chromium plated soap dish, any type, fixed to plug with chromium plated brass screws complete all as specified and directed. Make:- Jaquar cat No AKP-35731P or equivalent in CERA
S&F in repairs toilet paper holder Chromium plated brass complete all as specified and directed. Make:- Jaquar cat No ACN 1153S or equivalent in CERA
S&F in repairs towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden plastic cleats (minimum weight 190 gms) complete all as specified and directed .
S&F Towel ring, of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (min wt 90 gms) complete all in specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed .
S&F in repairs chromium plated angle/stop valve CP brass , fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or brass ferrule of 15mm bore fixed in position complete all as specified and directed.
M&L for for vertical fibre cloth venetian blinds consisting of aluminium head rail vanes/ louvers of 80 mm width of flaps driven string of approved tint and traverse cord fixed in position complete all as per manufacture instructions
Dismantling of wall and ceiling board (Fibre,pulp,insulation etc.) or insulation board /slab/blankets any thickness including cover fillet , GI Frame work and hangers /rod etc complete all as specified and directed by Engr-in-Charge.
M&L for false ceiling with 9 mm thick Gypsum tile including providing and fixing pre-painted white LAGYP wall steeper angle trim size 19x24x0.43mm thick fixed to brick wall/partition with the help of nylon sleeve and screw/LAGYP self tapping 25mm or 38mm screw respectively at 610mm centre to centre and suspended LAGYP main runner (Tee) size 24x32x 0.26mm (botton pre-painted) from sofit in one direction with the help of LAGYP soffit cleat, 8mm steel explained faster, LAGYP Hanger system which incorporates suspended rod with galvanised LAGYP spring adjusting clip at 1220mm centre to centre (bottom pre-painted) is inserted fixed into th slots provided in the main runners (Tee) at 1200mm centres to form 1200x600mm grid and LAGYP short runner (Tee) at 1200mm 24x24x0.26mm and 600mm (bottom pre-painted) is insert into the slots provided in the short runner (tee) at 600mm centre to centre to form 600x600mm grid complete all as per manufactures specified instructions complete all as specified & directed.
Taking down chowkats or frames or partitions( (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm including making holes as reuired for receiving PCC and to match with the existings complete all as specified and directed.
S&F aluminium section duly powder coated of any colour not less than 50 micron thick for swing door shutters partly panelled and partly glazed comprising top rail 86.17x44.45x1.60mm bottom and lock rail 150x44.45x2.00 mm and styles 47.50x44.45x1.6mm and including joining cleats, aluminimum snap beading, rubber gasket glazing clips and one disc type handle and one aluminimum tower bolt 200mm long for each leaf on each side with one floor spring and one number 6 leyer dead lock of brass for each leaves fixed in position complete all as specified and directed at site. Note :-Glazing and prelaminated particle board insertion shall be measured and paid separately under relevent items of BOQ.
S&F aluminium anodised frame, having anodised thickness not less than 15micron for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium section powder coated of any colour not less than 50 micron for windows/ cupboard framed shutters (fixed/openable) frame made out of alumminium frame of section 63.50mmx 38.10mm x1.60mm thick and shutter fixed or open able horizontal and vertical members of aluminium powder coated section 47.50x44.45x1.60mm thick of aluminium beading rubber gasket, aluminium fittings such as 2 Nos hinges 75mm long, 02 Nos tower bolts 150mm long, 150mm stay rod and one handles 125mm etc complete for each leaf all as specified and directed. Note :- Glazing & prelaminated particle board instertion measured and paid separately under relevent items of BOQ.
S&F 12 mm thick prelaminated particle board exterior grade with decorative choice laminations both sides for insertion to panels of aluminium shutters/partitions etc complete all as specified and directed .
Taking down of aluminimum partition including glass and partical board alongwith frame complete all as specified.
S&F aluminimum anodised, having anodised thickness not less than 15 micoron fully glazed / partly glazed panelled partitions and fixed glazing made out of aluminimum section 63.50x38.10x1.60mm including necessary jointing cleats glazing clips, rubber packing aluminimum snap beading screws etc, frame work fixed to walls, floor and ceiling with rawl plug wherever required complete all as specified and as directed. Note :- (i) Sheet glass and particle board shall be measured and paid for separately. (ii) Area of each panel shall not exceed 1 Sqm.
All as per ser item No 178 here-in-above but n.exc. 0.5 Sqm in each pane.
M&L for providing PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundation, filling, sub base floor and mass concrete complete all as specified and directed.
M & L for providing RCC M-20 (Design mix)( using 20MM graded stone aggreate) as in foundations, footings, foundation plinth beams; bases for columns and mass concrete complete all as specified and directed.
M & L for providing RCC M-20 (Design mix) using 20mm graded stone aggreate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for applying water proofing treatment to roof slab top as under: (a) Apply a coat of approved bituminious primer @0.20 kg per Sqm and applying hot blown bitumen 85/25 @ 1.20 kg sqm. (b) Laying APP polymer modified memberane 3mm thick and not less than 3.5 kg per sqm with side end laps by torch application method as specified. (c) Applying a coat of solar reflective bituminious aluminimum paint @ 0.15 kg per sqm over the membrance complete all as specified and directed. Note :- W.P.T. to roofs shall be carried out by authorised applicator of manufacturers as approved by GE.
M&L for 40 mm thick Damp proof course in cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) to horizontal or vertical surfaces of brick walls including necessary formwork, complete all as specified and directed. Note :- W.P.C. shall be measured and paid separately under respactive item of BOQ.
M&L for rendering 5mm thick in cm (1:3) on brick work or concrete surfaces as on ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for providing RCC M-25 (Design mix) (using 20mm graded stone aggreate) as in roof Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for providing RCC M-25 (Design mix) (using 20mm graded stone aggreate) as in chajjas complete all as specified and directed.
M & L for providing RCC M-25 (Design mix) (using 20mm graded stone aggreate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for broken stone or bouilders hard core of gauge n exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all specified and directed.
Preparation of undecorated plastered wall surface and M & L for applying two coats of cement base paint complete all as specified and as directed .
Preparing undecorated plastered surface and M & L for applying three coats of white wash on ceiling complete all as specified and as directed .
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed .
All as specified items No 192 but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M/L for rendering 15mm thick in CM (1:3) to receive W.P.T on roof surface, mixed with integral water proofing compound as per the manufacturers instruction to complete all as specified and directed by Engr--in-charge. Note:- WPC shall be measured and paid separagtely.
Supply only integral water proofing compound (ISI marked on packing).
M/L for providing plain cenent concrete type C- 2, 1:3:6 (using 40mm graded stone aggregate) as in plinth Protection, sub base of floor, surfaces, finished even & fair without using extra cement complete all as specified and directed.
M & L for factory made steel rolling shutter thickness of laths 1.25mm thick gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type all as specified and directed.
S & F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S & F ball bearing suit to rolling shutters complete all as specified and directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded. Conforming to IS of Z section complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings,etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 290, Gde-E-165 complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
Providing formwork to flat rough concrete surface to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
Providing formwork for flat rough concrete surface to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed..
M & L for applying two coat of synthetic enamel paint over shop coat primer on factory made steel surfaces such as rolling shuters and window complete all as specified and directed.
Providing formwork to flat sides of rough surface of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Providing formwork to rough finished on flat plan sruface concrete square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
Providing formwork to rough finished surface of concrete on flat plan to chajjas and similar items including edges complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:4) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supplying & fixing of any colour PVC water storage tank 500 ltr capacity HDPE, IS-12701 Marked double layered , cylindrical vertical type fixed and hoisted in position on roof upto 3 storey building complete with inlet/outlet of 20mm outer dia 3 layer PP-R pipe connection including closed top with locking arrangement including supply & fixing ball valves high prsessure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm dia and the minimum weight of valves 210 gms complete all as specified and directed by Engr-in-Charge Note : Inlet, outlet & wash out pipe will be measured and paid separately.
Supplying & fixing of any colour PVC water storage tank 1000 ltr capacity HDPE, IS-12701 marked double layered , cylindrical vertical type fixed and hoisted in position on roof upto 3 storey heigh building complete with inlet/outlet of 25 mm outer dia 3 layer PPR pipe connection including closed top with locking arrangement, including supplying & fixing Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight of valve 210 gms ) complete all as specified and directed by Engineer-in-Charge Note : ( Inlet, outlet & wash out pipe will be measured and paid separately.
Excavation in tranches n. exc. 1.5m wide & n. exc 1.5 m deep in depth for foundation, etc or for shafts, pier holes etc n.exc. 10Sqm on plan, or for taking up or down or laying of cables, water pipes etc. and getting out in soft/loose soil complete all as specified & directed.
All as per ser item No 212 here-in-before depth exc 1.5 m but n. exc 3 m depths.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and as directed.
Removing excavated materials, soil, exceeding 1.5km but not exceeding 5 km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
M&L for including necessary T&P for dismentaling of existing BER Central AC Plant 3x75TR complete with AHUs, cooling tower, Pumps, Chiller machines, all piping, ducting panels, and all other connected accessories and deposited to MES store yard complete all as specified and directed.
S&F CAP retro sign board of size 2.2 x 1.0 Metre using retro reflective high ingtensity prismatic reflective sheeting, the back ground of boad is Blue Colour with white border and writing letter, numbers white colour mentioning the AC Plant details, and single line diagram, retro sign board shall be pasted on 3mm thick ACP sheet, the board shall be fixed on steel tubular poles including fixing of mild steel clamps, nuts, bolts, washer etc complete all as directed.
M&L for including necessary T&P for taking down existing items of fire alarm system (i.e. smoke/heat detectors, Response Indicators, manual call point sprinkles, ceiling speakers, MS conduit, fire cable) and desposit in safe custody to MES store yard and re-fixing the same after completion of necessary ceiling work and ducting work including if required necessary extra new MS Conduit, GI pipe Heavy class upto 25mm dia, FELP cable 1.5 Sqmm n.exc. 5.0 Metre length complete all as specified and directed by Engineer-in-Charge.
(MANNING AND OPERATION OF AC PLANT). Section-IV Operation of Central type AC plant during defect liability period, of 3 x 100 TR vide schedule 'A' Section-I for the duration of 24 hrs in three shift of (08 hrs per shifts) (6000 hrs to 1401 hrs, 1400 hrs to 2200 hrs and 2201 hrs to 0559 hrs) all days of week including Sunday and Holidays for deployment of one operator per shift (ITI/ diploma holder having adeuate experience in the respective trade) for two years from satisfactory completion of Phase-I test complete all as specified and directed. Note :- (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) All consumable such as refrigent gas, compressure oil and grase etc reuired for operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions and direction of GE during the period of manning and operations, cost of the same shall be deemed incluluded in the unit rates quoted by the contractor. (iii) Please ensure that all tradesmen engaged in subject work covered in EPF scheme. Proper documents shall be maintained in this regard and submitted alongwith each payment. (iv) The expanses incurred due to insured and EPF scheme for the staff deployed by the contractor for manning and operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible on this account. (v) In case contractor fails to employ the duty personnel in any of the shift, he shall be liable to bear the recovery @ Rs 1500/- per shift and no payment shall be made for that shift and no payment shall be made for that shift also.
Operation of Central type AC plant after defect liability period of 3 x 100 TR vide schedule 'A' section for the duration of 24 hrs in three shift of (08 hrs per shifts) (6000 hrs to 1400 hrs, 1401 hrs to 2200 hrs and 2201 hrs to 0559 hrs) all days of week including Sunday and Holidays for deployment of one operator per shift (ITI/ diploma holder having adeuate experience in the respective trade) for one years after defect liability period complete all as specified and directed. Note :- (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) All consumable such as refrigent gas, compressure oil and grease etc reuired for operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions and direction of GE during the period of manning and operation, cost of the same shall be deemed incluluded in the unit rates quoted by the contractor. (iii) Please ensure that all trade men engaged in subject work covered in EPF scheme. Proper documents shall be maintained in this regard and submitted alongwith each payment. (iv) The expenses incurred due to insured and EPF scheme for the staff deployed by the contractor for manning and operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible on this account. (v) In case contractor fails to employ the duty personnel in any of the shift, he shall be liable to bear the recovery @ Rs 1500/- per shift also.
Parksons Engineering Company Pvt Ltd
M/S N.K BUILDERS
BRITE INDUSTRIES
HV AIRCONDITIONING SYSTEMS PVT. LTD.
SVC PROJECTS PVT. LTD
NAFREF ENGINEERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .