Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹30.7 L+₹1.0 L (3.50%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹33.9 L+₹4.2 L (14.1%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹34.6 L+₹4.9 L (16.5%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.7 L+₹6.0 L (20.3%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
7 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700 022
REPAIRS/MAINTENANCE OF SUMMER COOLING APPLIANCES OF FORT WILLIAM ALONGWITH ALLIED WORKS UNDER GE (FW) KOLKATA
2020_MES_404509_1
GE(FW)/8710
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Fort William Kolkata
Refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹60,000
Yes
29 Jan 2021
17 Dec 2020
8 Jan 2021
17 Dec 2020
7 Jan 2021
31 Dec 2020
60 days
Amount
Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc, (Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of split type AC 2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc, (Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
Taking down for servicing of Window type AC 2.0 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
NOTE FOR ITEM NO. 01 to 04 :- (1) Defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items. (2) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (3) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
Supply and fix in repairs starting relay for 1.5 TR compressor all as specified and directed.
Supply and fix in repairs starting relay for 2 TR compressor all as specified and directed.
Supply and fix in repairs over load protector for 1.5 TR compressor all as specified and directed.
Supply and fix in repairs over load protector for 2TR compressor all as specified and directed.
Supply and fix in repairs Thermostate switch for 1.5 TR split type AC all as specified and directed.
Supply and fix in repairs Thermostate switch for 2 TR split type AC all as specified and directed.
Supply and fix in repairs Thermostate switch for 1.5 TR Window type AC all as specified and directed.
Supply and fix in repairs Thermostate switch for 2 TR Window type AC all as specified and directed.
Supply and fix in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 3/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 3/4'' dia complete all as specifed and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
Dismantling of defective condensing unit of split type AC of 2 TR capacity and supply & fixing new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacity, relay condensing motor with blade complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star )
Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star/LG/Samsung)
Dismantling of burnt condensor motor of 1.5 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star)
Dismantling of burnt condensor motor of 2.0 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star/LG/Samsung)
Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star/LG/Samsung)
Dismantling of burnt swing motor of 2 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC complete all as specified and directed. (Make of AC: Carrier/Voltas /Blue star/LG/Samsung)
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-410 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quatity complete all as specified and directed.
Supply only Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed.
Supply and fixed in repairs suction valve size 1/2" complete all as specified and directed .
Supply and fixed in repairs discharge valve size 1/4" complete all as specified and directed.
Supply and fixed in repairs suction valve size 5/8" complete all as specified and directed .
Supply and fixed in repairs discharge valve size 3/8" complete all as specified and directed.
Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), coil frame, wiring kit and running capacitor, relay , swing motor including testing on completion complete all as directed by the Engr-in-Charge.
Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity), coil frame, wiring kit and running capacitor, relay , swing motor including testing on completion complete all as directed by the Engr-in-Charge.
M&L for carrying out pressure leak test of split ACs 1.5 capacity by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. (NOTE: Nitrogen gas will be measured and paid seperately)
M&L for carrying out pressure leak test of split ACs 2.0 TR capacity by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. (NOTE: Nitrogen gas will be measured and paid seperately)
M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. (NOTE: Nitrogen gas will be measured and paid seperately)
M&L carrying out pressure leak test of 2.0 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. (NOTE: Nitrogen gas will be measured and paid seperately)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit /match the existing system complete all as specified and directed.
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit /match the existing system complete all as specified and directed.
Supply and fixing in repairs front grill for window AC of 1.5 TR /2TR of existing make complete all as specified and directed.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
S&F Bottom tray of 1.5 ton /2 ton capacity window type AC made out of 14 SWG mild steel sheet Including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed including providing PCC platform of size 900 mm x 600 mm x 200 mm (1:4:8) ) type D-2 using 40 mm graded crushed stone aggregate) alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable, drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable, drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. Note :- Charging of gas refrigerant will be paid and measured separately
All as per item No 54 here in before but 2 TR capacity reciprocating compressor
All as per item No 54 here in before but 1.5 TR capacity rotary type
All as per item No 54 here in before but 2 TR capacity rotary compressor
S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed by the Engr-in-Charge. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ)
Taking down indoor unit of 2.0 TR capacity by preserving the existing gas in outdoor unit replacing the unserviceable GI bracket and refixing at same position including testing complete all as directed by the Engr-in-Charge. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ)
Taking down unserviceable indoor cooling coil motor of 1.5 TR / 2.0 TR capacity and repairing & refixing complete testing and running all as directed by the Engr-in-Charge.
Taking down out door unit of 1.5TR/2.0 TR capacity for removing unserviceable angle iron bracket and S&F Fabrication of angle iron stand of size 50x50x6mm suitable for fixing out door unit with two coats synthetic enamel paint over a coat of primer and refixing the out door unit connection the suction and discharge line complete testing complete all as specified and as directed.
Taking down unserviceable blower motor base (2mm thick Mild Steel CRCA Sheet) of 1.5 TR/2TR capacity split AC and supply and fixing new blower motor base by welding / fixing by nut and bolt refixing the blower motor after completing the base and aligning the motor complete as directed by the Engr-in-Charge.
S&F Compressor sealed unit of Window type Air Conditioner of capacity 1.5 TR reciprocating type by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed by the Engr-in-Charge.
All as per item No 67 here in before but 2.0 TR capacity reciprocating compressor.
All as per item No 67 here in before but 1.5 TR capacity rotary type compressor.
All as per item No 67 here in before but 2.0 TR capacity rotary compressor.
S&F Cooling coil condenser unit of Window type Air Conditioner of capacity 1.5/2.0 TR including providing connections and fixing in proper position including taking down old one complete all as directed by the Engr-in-Charge.
Taking down unserviceable blower motor of existing make/model of window type Air Conditioner 1.5 TR and refixing in proper position after rewinding and repair including providing all connections, complete all as directed by the Engr-in-Charge.
Taking down unserviceable blower motor of existing make/model of window type Air Conditioner 2.0 TR and refixing in proper position after rewinding and repair including providing all connections, complete all as directed by the Engr-in-Charge.
S&F Blower motor fan blade of existing make/model of window type Air Conditioner 1.5 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Blower motor fan blade of existing make/model of window type Air Conditioner 2 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Runner of existing make/model of Window type Air Conditioner 1.5 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Runner of existing make/model of Window type Air Conditioner 2 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required in exc. Half Brick but not exc. one brick thick Walls and providing three coats white wash on finished surface complete all as specified and as directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer, cleaning and stacking bricks removing surplus serviceable bricks, hard-core and rubbish etc from site complete all as specified and as directed.
M&L Cutting through wooden window frames with MS round bars for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer and removing rubbish material not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point complete all as specified and as directed.
M&L Cutting through aluminium window frames with MS round bars for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick, size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer and removing rubbish material not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point complete all as specified and as directed.
S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
Supply and fix in repair power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed.
Supply and fix in repair power contactor 3 pole, coil voltage 415 Volts of capacity 32 Amps Complete all as specified and as directed.
Supply only remote control hand set for 2.0TR capacity split AC alongwith batteries complete all as specified and as directed.
Supply only remote control hand set for 1.5TR capacity split AC alongwith batteries complete all as specified and as directed.
Supply only remote control hand set make suitable for 2.0TR capacity window type AC incl batteries complete all as specified and as directed.
Supply only remote control hand set suitable for 1.5 TR capacity window type AC incl batteries complete all as specified and as directed.
M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit and descaling of condensor coil for Vertical type 3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed.
S&F PCB kit complete for Vertical type Air Conditioner of any make and capacity complete all as specified and as directed.
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 2.5 TR by removing of old burnt compressor and fixing as per manufacturer instruction complete all as specified and as directed. Note :- Charging of Refrigerant gas will be measured and paid separately
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 3.5 TR by removing of old burnt compressor and fixing as per manufacturer instruction complete all as specified and as directed. Note :- Charging of Refrigerant gas will be measured and paid separately
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 4.5 TR by removing of old burnt compressor and fixing as per manufacturer instruction complete all as specified and as directed. Note :- Charging of Refrigerant gas will be measured and paid separately
Taking down unserviceable condensor motor of existing make/ model of Vertical type Air Conditioner 2.5/3.5/4.5 TR (Outdoor) and refixing in proper position after rewinding and repair including providing all connections complete all as specified and directed.
Taking down unserviceable blower motor of existing make/model of Vertical type Air Conditioner 2.5/3.5/4.5 TR (Indoor) and refixing in proper position after rewinding and repair including providing all connections complete all as specified and directed.
Dismantling of defective condensing unit of Vertical type Air Conditioner of 2.5 TR capacity and supply and fixing new condensing unit complete with condensing copper coil complete all as specified and directed.
Taking out existing outdoor unit of Vertical type Air Conditioner including refrigerant lines and electrical connections (of capacity 2.5/3.5/4.5 TR) and re-fixing at new location as directed including providing PCC platform of size 900 mm x 600 mm x 200 mm (1:4:8) ) type D-2 using 40 mm graded crushed stone aggregate), finished even and smooth without using extra cement alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable and drain pipe shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of Vertical type Air Conditioner including refrigerant lines and electrical connections of capacity 2.5/3.5/4.5 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable and drain pipe to be measured and paid separately under relevant item of this schedule)
Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/ replacement of defective accessories/components and testing complete all as directed by Engr-in-charge .
NOTE FOR ITEM NO. 99 :- (1) Defective spares for making the refrigerator units in satisfactory working condition will be measured & paid separately under relevant items. (2) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (3) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs complete all as specified and directed
Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 280/310 ltrs complete all as specified and directed
Supply & Fix Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 ltrs complete all as specified and directed
Supply & Fix PTC Relay with overload suitable for refrigerator of capacity 165/190/200 ltrscomplete all as specified and directed
Supply & Fix PTC relay with overload suitable for refrigerator of capacity 250/286/310 Ltr complete all as specified and directed
Supply & Fix Capillary tube of size 0.36mm dia for any type/size refrigerator complete all as specified and directed
Supply & Fix Copper pencil strainers of size 4" long double mouth complete all as specified and directed
Supply & Fix PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
Supply & Fix Bimetal 2 wire/3wire /4 wire complete all as specified and directed
Supply & Fix Forst free fan motor SP 230 volts complete all as specified and directed
Supply & Fix Sensor for cooling coil complete all as specified and directed
Supply & Fix PCB timer of refrigerator 180-310ltrs required as per site complete all as specified and directed
Supply & Fix Condenser coil for 165 to 200 Ltrs complete all as specified and directed
Supply & Fix Condenser coil for 250 to 310 Ltrs complete all as specified and directed
S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all as specified and directed
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Regrigerator of Capaicty 165/180 Ltrs complete all as specified and directed. (Note: Re- Charging of gas will be measured and paid separetely)
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capaicty 285/310 Ltrs complete all as specified and directed. (Note: Re- Charging of gas will be measured and paid separetely)
Dismantling of defective water cooler storage type of 40/80/120/150 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/ components including testing complete all as specified and directed.
NOTE FOR ITEM NO. 117 :- (1) Defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items. (2) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (3) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
Supply & Fix Aluminium fan blade for blower motor for water cooler of capacity 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 ltrs/hrs complete all as specified and directed
Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 60/120/150 ltrs/hrs complete all as specified and directed
Supply & Fix Over load protector for compressor suitable for water cooler of capacity 40/80 Ltrs complete all as specified and directed
Supply & Fix Over load Protector for compressor suitable for water cooler of capacity 120/150 ltrs/hrs complete all as specified and directed
Supply & Fix Self closing bib tap/push tap 15mm dia, chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity complete all as specified and directed..
Supply & Fix PVC connection pipe high density 15mm dia 300mm long including jublee clamps for inner connection from tank outlet to tap complete all as specified and directed.
Supply & Fix 15 mm dia PVC connection pipe 450 mm long complete with PVC union at both end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON / CERA)
Supply & Fix 15 mm dia Float valve PVC complete with all accessories complete all as specified and directed
Supply & Fix new compressor suitable for 40/40 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (Note: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 40/80 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (Note: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 120 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 150 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (NOTE: Recharging of gas will be measured and paid separately).
Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make or type.
Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed by the Engr-in-Charge
NOTE FOR ITEM NO. 135 :- (1) Defective spares for making the deep freezer units in satisfactory working condition will be measured & paid separately under relevant items. (2) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (3) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
Supply & Fix new deep freezer compressor for storage capacity of 400 ltrs deep freezer including testing all as specified and directed . (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix new deep freedge compressor for storage capacity of 500 ltrs deep freezer including testing all as specified and directed . (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix Relay for deep freezer of any size/capacity complete all as specified and directed
Supply & Fix Overload for compressor of deep freezer of any size/capacity complete all as specified and directed
Supply & Fix Thermostate for deep freezer complete al as specified and directed
Supply & Fix 4" condenser fan motor 240 volt complete all as specified and directed
INDIA ELECTRICAL EQUIPMENTS
ELECTRO FREEZE
RADHA ENTERPRISE
SUDHA ENTERPRISES
M/S J S ENTERPRISES
UNIVERSAL
S B ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .