Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.0 L+₹260.40 (0.01%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹29.5 L+₹3.5 L (13.4%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L3 | Rejected-Finance Not being L1 |
Tender Value
₹31.7 L
EMD Value
₹63,473
Closing Date
19 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
SPL REPAIR TO RENEWAL OF CIRCUIT BREAKER AND CONNECTED ITEMS AT TREHGAM GRN UNDER GE 874 EWS
2023_MES_629191_1
CWEK-50/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 874 EWS
Class D Category b ii
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹63,473
HQ 133 WORKS ENGRS
2 Feb 2024
21 Nov 2023
27 Dec 2023
21 Nov 2023
19 Dec 2023
6 Dec 2023
21 Nov 2023 - 28 Nov 2023
29 Nov 2023
Amount
Disconnecting electrical connection and taking down HT OCB, 11KVA, 3 phase 630 amp capacity and depositing at MES store as directed by Engr-in-Charge.
Supply,installation ,testing and commisssioning of HT 11 KV Vaccum Cicuit Breaker (VCB) with panel, indoor type, of rating of 630 Amp, of rupturing capacity of 350 MVA with seperate trips relays and controls for (a) Over Current Tripping (adjustable threshold), (b) Earth Fault Tripping, (c) Under/ Over Voltage Faults (adjustable threshold) with tripping timing of less than VCBs already installed, with all necessary relays such as IDMT/(numerical relay) and master trip relays, hooter of 50 meter range, LED Beacon (hooter and beacon activation to be programmable for various trip settings and deactivation auto and manual), counter for counting of trippings (one for each type of tripping) and counter for Electricity (input) shutdowns/ absence, with all data being stored and retrievable using USBs, all controls and operation of VCB being of numeric type, having set of housing for circuit breaker carriage mechanical interlock and automatic safety shutter gear including padlocking arrangements with Three Phase LCD Voltmeters (02 Sets), Three Phase LCD Ammeters (02 Sets), Three Phase LCD Power Factor meter, Three Phase LCD Wattage and kVA Meter, Three Phase LCD Multifunctional Electric Panel Meter (Secure Elite 445) with necessary CTs and PTs for all meters and any other devices, RYGB indicators (Two sets), with all meters duly caliberated for direct display of values without any factors, with pushbutton adjustable setting centralised LCD control, with 06 Nos isolaing plugs circuit breaker and all other fixing arrangements like PCC work in foundation, earthing and PCC cable duct all as specified and directed by engineer in charge, cable connection of above rating comprising of following:-
(a) Assembly of vaccum interrupter complete with epoxy support insulators and self aligining figer type isolating contacts. (b) Truck having internal racking in device for insertion and withdrawl of VCB complete with necessary interlocks. (c) Motor operated independent spring closed /spring tripping trip free oprsting mechanism closing and tripping push buttons and mechanical breaker closed/open spring chared/discharged indicators. (d) Mechanical operation counter (e) Shunt trip coils of 24 volt DC (capable of working in 12V DC and 180 - 270V AC also). (f) Breaker operated auxillary switch-04 Nos (N/O and N/C), Nos, bus bar chamber including a set of three all as specified. Note: (a) The job includes connecting with all existing cables using appropriate jointing kits and thimbles/ connectors, all made of copper (b) The Circuit Breater and Panel to be of same Make, Make : ABB/ Schneider (c) The VCB should be wholely dependent on the below mentioned battery bank and charger and no external charger/ power supply may be required. The control systems should have an internal source to function for one week (without tripping) even when the battery bank is not operational as per required voltage. No memory shall be lost because of non supply. The VCB should be able to function with variation of +/- 5 Volts supply from rated supply, with a protection beyond this limit.
Supply and install battery bank of 24 Volts containing 12 Nos of Valve Regulated Lead Acid Type 2 Volt Batteries of 125 AH each for use in VCBs/ OCBs with minimum warranty of 48 months (replacement/ free repair warranty) from date of installation, alongwith smart battery charger as below, with battery of make Exide, Luminous, AMCO or equivalent as approved by engineer in charge
All as per item Ser No 24 but plain sheet as in roof covering/cladding to wall fixed with tapping screws complete all as specified and directed by Engr-in-Charge.
demolition of brick work or stone masonry built in cement mortar complete all as specified and directed by Engr-in-Charge.
M&L for walling of random rubble masonry, well bonded, bedded and solidly hearted,built in CM (1:4) complete all as specified and directed by Engr-in-Charge.
M&L or rendering 15 mm thick on stone masonry concrete surfaces or other than air faces of brick work or on one side of lathing in CM 1:4 finished over and smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-1 in kerb or mud stops rounded or chamfered on edges all as specified (20mm graded aggregate) for copping including weathering slightly rounded or chamfered using form work (Straight or curved) complete all as specified and directed by Engr-in-Charge.
M&L applying two coats of cement base paint including preparation of newly plastered surface of wall complete all as specified and directed by Engr-in-Charge.
M&L hard core filling under floor, breaking stone or boulder exc 63mm and n.exc 100mm gauge of sand stone complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) in foundations filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Dismantling of timber scantlings 40 sq cm and over in sec in any position in unframed work complete all as specified and directed by Engr-in-Charge.
M&L for second class soft wood as in scantling clean sawn fixed in position complete all as specified and directed by Engr-in-Charge.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and directed by Engr-in-Charge.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc of Fe 410-W(Gde E-250) quality A, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed by Engr-in-Charge.
M&L two coats of synthetic enamel paint over a priming coat with red oxide over steel surfa e over 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving n/exc 15 Cm thickness complete all as specified and directed by Engr-in-Charge.
M&L 100 mm thick PCC type 1:4:8 (40 mm graded crushed stone agg) as in sub base complete all as specified and directed by Engr-in-Charge.
M&L for 100 thick cement concrete type, B-1m 1:2:4 (20mm graded aggregate) as in base complete all as specified and directed by Engr-in-Charge.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
M&L for 2nd class S/W weather boarding clean sawn, plain 20mm thick complete all as specified and directed by Engr-in-Charge.
M&L for applying two coats of synthetic enamel point over a coat of pink primer including preparation of new wooden surface exc 10 cm width or girths complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel sheeting any gauge thickness in roof coveringcomplete all as specified and directed by Engr-in-Charge.
S&F pre-painted falvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havng tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
All as per item Ser No 24 but plain sheet as in roof covering/cladding to wall fixed with tapping screws complete all as specified and directed by Engr-in-Charge.
M&L 50mm thick sand cushion under paving block including watering and consolidation for interlocking tiles complete all as specified and directed by Engr-in-Charge.
S&F machine pressed precast concrrete interlocking pver block 60mm thick any shape with gray cement and pigment complete all as specified and directed by Engr-in-Charge.
M&L 100mm thick PCC1:3:6 type C-2, (using 40 mm graded aggregate) as sub base complete all as specified and directed by Engr-in-Charge.
M/S Noor Mohammad Shalla
M/s Lal Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .