Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.1 LAccepted-AOC | ₹33.1 L | 1 | Accepted-AOC Lowest-1 |
| 2 | 2₹53.9 L+₹20.9 L (63.0%)Rejected-AOC | ₹53.9 L+₹20.9 L (63.0%) | 2 | Rejected-AOC Lowest-2 |
| 3 | 3₹60.1 L+₹27.0 L (81.8%)Rejected-AOC | ₹60.1 L+₹27.0 L (81.8%) | 3 | Rejected-AOC Lowest-3 |
Tender Value
₹35.5 L
EMD Value
₹70,940
Closing Date
31 Jul 2021, 12:00 pmClosed
Executive Engineer
Office Of PHED Fatehabad
Fatehabad Tulsi Chowk Under Storm Water Drainage
2021_HRY_174753_4
Fatehabad Tulsi Chowk Under Storm Water Drainage
Open Limited
Civil Works
Works
90 days
Fatehabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Yes
₹70,940
Yes
29 Sept 2021
26 Jul 2021
31 Jul 2021
26 Jul 2021
31 Jul 2021
26 Jul 2021
Amount
N.S. Item
PUMPING MACHINERY/RAW WATER PUMP / Supply & Erection of non clog submersible pump with suitable electrical motors with accessories as described in Schedule No. II complete in all respect with submersible cable of suitable size 30 M double length with complete base frame, lifting monorail, chain guide line etc. A) Raw Sewage water pump set Raw Sewage Water Pump set 3900 LPM 18 Mtrs Head /3900 LPM 18 MTRS HEAD SEWAGE
PIPES /DI PIPE / Supply and fixing following DI D/F pipe and specials/ bell mouth/ including cost of joining materials laying jointing, refilling of including making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water pumping sets at water works in position as per specification given in schedule No.II. / 200
PIPES /DI PIPE / Supply and fixing following DI D/F pipe and specials/ bell mouth/ including cost of joining materials laying jointing, refilling of including making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water pumping sets at water works in position as per specification given in schedule No.II. / 300
ELECTRICAL ITEMS/PANEL BOARD. / (A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. (A) For Raw Sewage Water Pump set 3900 LPM 18 Mtrs Head 3 Nos. a) Main switch 200 Amp 3 No.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp meter 100X100mm range 0 to 100 Amp 3 Nos. (AE/KAPPA/L&T) D) CT 100/ 3 Nos. (AE/KAPPA/L&T) E) VSS 1 No.& ASS 2 No. each of approved make F) SPP 3 No. of approved make g) Motor starter, Star delta for 3900 LPM 18 Mtr = 3 Nos. H) Capacity KVAR as per site requirement 3 No. I) Indicating Lamp - One Set J) Change Over switch 200 Amp = 3 No. Supplying erection, testing of ISI marked copper wire for 3 Nos. motors with under ground system in PVC and flexible pipes copper wire size 25 sq. mm complete in all respects with accessories like thimble etc. complete in respects. / 1200X900MM
ELECTRICAL ITEMS/COPPER WIRE / upply, ercetion, testing and commissioning of LT cables PVC Copper armored cable (160 Sqmm) including cost of thimbles, lugs for marking connection underground covered with sand and bricks / in trenches / in pipe on steel bridges (Detail of cable sizes and length to be provided be clearly mentioned) for making connections from transformer to main Lt panel in addition to cables of appropriate size from main LT panel to respective CW LT panel and then ultimetly providing connections to Sewerage Sets required for following connections as per site conditions. Supply erection, testing of standard make Wiring of 3 No motors with under ground system in PVC and flexible pipes 16 sq.mm (copper wire) dully ISI marked / 25MM 3 CORE COPPER WIRE
MACHINERY ITEMS/DIESEL GENERATING SET / Supply, erection, testing and commissioning of diesel generating set 100 KVA /75 KW radiator cooled, 3 Phase, 4 wire, 50 cycles 415+ (-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common M.S. fabricated base frame with diesel engine. The rating should be at 1500 RPM (a) Diesel Engine b) Alternator c) Bettery 24 V (d) Base Plate (e) 1x 95 sq mm 3.0 core XLPE Aluminum = 20 m (f) Tools A.M.F. PANEL (a) Motorised change over switch 150 Amp 4 P with fuse base and HRC links 150 Amp. (b) Under voltage/ over voltage relay - 2 No. 415 VAC (c) Engine Start relay 24 VDC 1 No. / 100 KVA/75 KW
ELECTRICAL ITEMS/JOB WORK FOR ELECTRIC FITTING / Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications. /LIGHT FITTING INCLUDING WIRE IN THE PUMP CHAMBER
ELECTRICAL ITEMS/EXHAUST FAN / Providing & fixing of Ceiling fan 1200 mm (48") with speed adjuster of reputed make (Make Cormption, Usha, Bajaj, Orient) complete in respect. / EXHAUST FAN
ELECTRICAL ITEMS/CFL / Supply, erection, testing of reputed make CFL vapour light 100 watts with fitting and accessories complete in respects. / CFL 100 WATTS
MISCELLANEOUS ITEMS/MISC. ITEMS / "Providing & Fixing Road gully Chamber & Cover frame of ISI Marked Complete in all respect. (24" x 18")" / ROAD GULLY CHAMBER and COVER FRAME
Bidder Name
Amount
ONKAR SINGH(GSTN-06CXXPS4617M1ZH)
Mehar Singh Contractor(GSTN-NA)
VINOD KUMAR KHANNA(GSTN-NA)
Mehar Singh Contractor
VINOD KUMAR KHANNA
ONKAR SINGH
VINOD KUMAR KHANNA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .