Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC SURAJ HOUSE KOTHI NO 1614 SECTOR 7E FARIDABAD HR | FARIDABAD | FARIDABAD | HARYANA | ₹19.5 L Quoted ₹21.1 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹21.6 LRejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹21.6 L | L2 | Rejected-Finance Not Found in order |
| 3 | L3₹23.3 LRejected-Finance ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | ₹23.3 L | L3 | Rejected-Finance Not Found in order |
| 4 | L4₹23.3 LRejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹23.3 L | L4 | Rejected-Finance Not Found in order |
| 5 | L5₹24.0 LRejected-Finance JYOTI BAKERY 1ST FLOOR A5 HSEDRI G RZA 5 PALAM NEW DELHI SOUTH WEST DELHI DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹24.0 L | L5 | Rejected-Finance Not Found in order |
| Sl No | Description | Qty | Unit | B.R. Enterprises L9 | Shiv Enterprises L12 | Microsys Automation India L13 | Deven Associates L6 | P S TRADERS L4 | HSEDRIG ENGINEERS AND CONTRACTORS L5 | AJIT PARKASH BREJA L1 | PRASAD ELECTRICALS L2 | M P TYAGI ENGINEERS AND CONTRACTORS L8 | M/s Naresh Kumar Gupta & Co. L10 | RS GREEN INDIA CONSTRUCTION L14 | jain associates L7 | Yadav Enterprises L11 | CHOUDHARY ELECTRICAL L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in various locations & taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed
(Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after as 'Supply only'). | 1,650 | EACH COMPLAINT | 90 ₹1,48,500 | 100 ₹1,65,000 | 90 ₹1,48,500 | 59 ₹97,350 | 75 ₹1,23,750 | 87 ₹1,43,550 | 70 ₹1,15,500 | 88 ₹1,45,200 | 99 ₹1,63,350 | 110 ₹1,81,500 | 110 ₹1,81,500 | 90 ₹1,48,500 | 59 ₹97,350 | 100 ₹1,65,000 |
| 2.00 | Labour only for attending day to day electric supply complaints of day to day maintenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including Note down the complaints from various locations in complaints register and distribution to the trademen complete all as directed.
(Note:-
(i) Any meterial required for atteding complaints shall be measured & paid seperately under respective item here after as 'supply only')
(ii) The suitable shift duites as deems fit shall be decision of the Engr-in-charge | 850 | EACH COMPLAINT | 90 ₹76,500 | 80 ₹68,000 | 50 ₹42,500 | 49 ₹41,650 | 75 ₹63,750 | 87 ₹73,950 | 70 ₹59,500 | 55 ₹46,750 | 99 ₹84,150 | 99 ₹84,150 | 100 ₹85,000 | 90 ₹76,500 | 49 ₹41,650 | 100 ₹85,000 |
| 2.01Notes for Item No 1.01 & 1.02 :- (i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after. (ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate number of helpers as directed by Engineer-in-charge. (iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' of BOQ. However, no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as 'supply only'). (vii) All T&P required for attending the Complaints shall be provided by the contractor.) | |||||||||||||||||
| 2.02(viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. All the fitting & fixtures shall be measured and paid supply only in respective items of BOQ i.e. Ser Item No. 3 to 16, 17, 18.01 to 18.05, 24, 44 to 50 and 54 to 60. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record. | |||||||||||||||||
| 3.00Supply only GI Socket 'medium grade' ISI Marked superior / standard of a make of following sizes :- | |||||||||||||||||
| 3.01 | 15 mm bore | 70 | EACH | 15 ₹1,050 | 25 ₹1,750 | 16 ₹1,120 | 15 ₹1,050 | 12 ₹840 | 12 ₹840 | 10 ₹700 | 12 ₹840 | 99 ₹6,930 | 15 ₹1,050 | 30 ₹2,100 | 11 ₹770 | 12 ₹840 | 15 ₹1,050 |
| 3.02 | 20mm bore | 120 | EACH | 20 ₹2,400 | 35 ₹4,200 | 22 ₹2,640 | 18 ₹2,160 | 12 ₹1,440 | 15 ₹1,800 | 10 ₹1,200 | 15 ₹1,800 | 99 ₹11,880 | 15 ₹1,800 | 30 ₹3,600 | 15 ₹1,800 | 20 ₹2,400 | 15 ₹1,800 |
| 3.03 | 25mm bore | 65 | EACH | 29 ₹1,885 | 40 ₹2,600 | 30 ₹1,950 | 20 ₹1,300 | 13 ₹845 | 18 ₹1,170 | 10 ₹650 | 22 ₹1,430 | 99 ₹6,435 | 20 ₹1,300 | 32 ₹2,080 | 19 ₹1,235 | 20 ₹1,300 | 20 ₹1,300 |
| 3.04 | 40mm bore | 15 | EACH | 42 ₹630 | 100 ₹1,500 | 60 ₹900 | 59 ₹885 | 14 ₹210 | 20 ₹300 | 10 ₹150 | 44 ₹660 | 199 ₹2,985 | 25 ₹375 | 35 ₹525 | 27 ₹405 | 40 ₹600 | 50 ₹750 |
| 3.05 | 50mm bore | 15 | EACH | 99 ₹1,485 | 130 ₹1,950 | 100 ₹1,500 | 69 ₹1,035 | 15 ₹225 | 25 ₹375 | 10 ₹150 | 55 ₹825 | 199 ₹2,985 | 30 ₹450 | 40 ₹600 | 40 ₹600 | 60 ₹900 | 80 ₹1,200 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
8 Jan 2026, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY EXTERNAL WATER SUPPLY AND ELECTRIC COMPLAINTS AT NODAL POINT II AREA AND COD AREA IN THE AOR OF AGE U WATER SUPPLY NO 1 UNDER GE U WATER SUPPLY DELHI CANTT 10
2025_MES_745252_1
GE/WS/Token No-57 OF 2025-26
Open Tender
Civil Works
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹88,000
Yes
14 Mar 2026
19 Dec 2025
10 Jan 2026
19 Dec 2025
8 Jan 2026
2 Jan 2026
Amount
Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in various locations & taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed (Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after as 'Supply only').
Labour only for attending day to day electric supply complaints of day to day maintenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including Note down the complaints from various locations in complaints register and distribution to the trademen complete all as directed. (Note:- (i) Any meterial required for atteding complaints shall be measured & paid seperately under respective item here after as 'supply only') (ii) The suitable shift duites as deems fit shall be decision of the Engr-in-charge
Notes for Item No 1.01 & 1.02 :- (i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after. (ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate number of helpers as directed by Engineer-in-charge. (iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' of BOQ. However, no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as 'supply only'). (vii) All T&P required for attending the Complaints shall be provided by the contractor.)
(viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. All the fitting & fixtures shall be measured and paid supply only in respective items of BOQ i.e. Ser Item No. 3 to 16, 17, 18.01 to 18.05, 24, 44 to 50 and 54 to 60. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record.
Supply only GI Socket 'medium grade' ISI Marked superior / standard of a make of following sizes :-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Supply only GI Elbow 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Supply only GI Union 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only 'GI Nipple' of suitable length as required at site & ordered by EIC both end screwed 'Medium Grade', ISI marked superior / standard of a make of following sizes:
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Supply only GI Reducing socket 'medium grade' ISI marked superior / standard of a make of the following sizes :-
20 mm x 15 mm bore
25 mm x 20 mm bore
50 mm x 40 mm bore
25 mm x 15 mm bore
Supply only GI Solid plug heavy duty ISI Marked superior / standard of a make of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Tee 'Medium grade' ISI Marked superior / standard of a make of following sizes : -
15mm x 15mm x 15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
40 mm x 40 mm x 40 mm
50 mm x 50 mm x 50 mm
50 mm x 50 mm x 25 mm
Supply only PTMT float valve of sizes as under, with epoxy coated aluminium rod 250mm length and high density plastic ball of 150mm dia complete all as specified and as directed:-
15 mm bore
20 mm bore
25 mm bore
50 mm bore
Supply only Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 complete all as specified and as directed of following sizes:-
Supply only of following items:
lead pig bar
Spun Yarn
Labour only for run lead joint by using new lead and new spun yarn including jointing material for CI/DI pipes of following size/bore. (Note: Run lead and spun yarn used for repairing the joints following sizes of pipe will be measured and paid seperately under respective items as supply only.)
Supply only Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and as directed.
Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
Taking up old GI steel tubing of following sizes with connections from Trenches/floors/walls including cleaning for refixing or removal complete all as specified and as directed. Note :- (i) Excavation & earth work shall be measured & paid separetely.
Supply & Laying of GI pipe 'medium grade' ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes. (Note:- Excavation and earth work will be measured and paid separately.)
Taking up CI/DI Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lead joints and recovering lead and including cleaning for refixing or removal, making good disturbed surface complete all as specified and as directed. (Note:- (i) Excavation & earth work shall be measured & paid separetely. (ii) Layout plan for laying of DI pipe shall be given by EIC in writing. (iii) DI pipe whole quantity of tender shall be procured by contractor for payment in 1st RAR as material lying at site.
Material & Labour for rubber gasket joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore comp
Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- Note:- (i) MS Flanges incl fabrication work will be measured and paid separately.
Supply, fixing, jointing & testing cast Iron Sluice Valve of following size ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. (Note :- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items.
80 mm dia
100 mm dia
150 mm dia
M&L applying painting with two coat of synthetic enamel paint as per existing pattern on pipe surface/header connection including preparation of surfaces by scratching and removing the rust, applying one coat red oxide primer complete all as specified and as directed.
M&L removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge.
M&L openning of gland packing coupling and removing the unserviceable gland rope from Sluice valve of size 80 to 300 mm dia and supply & fixing the new gland rope all as per existing size gland rope complete all as specified and directed.
M&L Decorative ultra slim round profile LED lightning fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unserviceable light fitting complete all as specified and as directed.
Supply and fixing in replacement 45 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with providing new GI pipe 0.6mtr on angle bracket fixing on wall and connectng to ceiling rose with apropriate wire
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw / flanged type and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and directed by Engineer - in - charge
Testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) in the area under AGE(U) W/S No I and submission of detailed test reqport to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle for testing of water of different sources from Govt Approved laboratory as mentioned in PS. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission the test report to EIC and after ward the same will be submit by EIC to AO with their specific recommendation regarding suitability of water for drinking purpose.
Supply only following electrical items :
PVC insulation tape role 15mm wide, 20 Running meter long
PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, 1100 volts grade "FRLS type"
PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade "FRLS type"
Suppply & fixing in replacement MCCB 200 Amps, 3 pole , breaking capacity 36 kA, connection complete all as specifed & directed
Suppply & fixing in replacement MCCB 100 Amps, 3 pole , breaking capacity 25 kA, connection complete all as specifed & directed
Suppply & fixing in replacement MCCB 63 Amps, 3 pole , breaking capacity 16 kA,connection complete all as specifed & directed
Suppply & fixing in replacement analog type time switch FM 1/Quartz daily 240 volts , AC, 50 Hz code J 6107B 204 connection complete all as specifed and directed.
Supply, Installation Testing & Commissioning of ULTRASONIC LEVEL SENSORS Water Level Sensor for underground tank suitable for up to 6 meter water level depth of U/G sump, with dead band of less than 0.6meter, IP66 protection, accuracy of 0.25% of F.S. and RS485 Modbus RTU communication protocol, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, LCD display type, vertical type mounting on top of OHTs with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor ML-2, 32-40 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML 1.5 relay, range 10-16 Amp complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML-2 starter range 9-14 Amps complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML-2 starter range 13-21 Amps complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML-2 starter range 20-32 Amps complete all as specified and as directed.
Supply and fixing in replacement single phase preventor, type VSP-II complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 ltrs capacity, tripple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed. Note: (i) For Pump Priming purpose in pump house.
Taking down cement plaster or cement lime plaster on PCC/Stone Surface/Brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed .
M&L Rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces finished even & smooth complete all as specified and directed .
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks bricks straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6 complete all as specified and directed.
Dismantling of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed.
M & L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed
M&L Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and directed.
M&L Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , Reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE: (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25/35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and as directed.
M&L fabrication (welding work) of MS Header /any size upto 300 mm MS pipe at various pump house for arresting leakages on header complete all as specified and directed.
Supply and installation of flanged ends Water Meter woltman type of size 50mm dia including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge.
Supply , installation, commissioniong and testing of smart water pump control system in borewell up to 10 HP including varun controller, remote, 02 no. of antennas (RF+GSM), user manual M2M SIM complete all as specified and as directed at site by the Engineer-in-Charge. Features: LCD Display, Dry run and over run protection, Smart Scheduling, App based control & Notifications, Internet free control with GSM and app control.
M&L for cleaning of dewatering/rain water, any storage capacity of water by removing mud, grits, debris etc and through out not less than 50 mtr complete all as specified and as directed .
An amount of Rs 1,62,025.00 shall be deducted from BOQ on account of schedule of credit
PRASAD ELECTRICALS (BID ID -3518922)
CHOUDHARY ELECTRICAL (BID ID -3519240)
P S TRADERS (BID ID -3519610)
HSEDRIG ENGINEERS AND CONTRACTORS (BID ID -3519167)
Deven Associates (BID ID -3519433)
jain associates (BID ID -3518320)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3517905)
B.R. Enterprises (BID ID -3517851)
M/s Naresh Kumar Gupta & Co. (BID ID -3519173)
Yadav Enterprises (BID ID -3518999)
Shiv Enterprises (BID ID -3518249)
Microsys Automation India (BID ID -3518376)
RS GREEN INDIA CONSTRUCTION (BID ID -3519383)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
tender57.pdf
Tender Documents • 0.78 MB
BOQ_834491.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid