EE(ELECT) FHQ BSF NEW DELHI
EE(ELECT) FHQ BSF NEW DELHI
Improvement upgradation Offices of PAD at Second floor of Pushpa Bhawan New Delhi SH Electrification
2021_BSF_634421_1
01/NIT/ENGG/ELECT/2021-22
Open Tender
Electrical Works
Item Rate
60 days
FHQ BSF NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹11,492
2 Jul 2021
18 Jun 2021
30 Jun 2021
19 Jun 2021
29 Jun 2021
19 Jun 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group-C Make Anchor Roma/Great White/Legrand
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make Havells/Kalinga/Finolex
3 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Make Havells/Kalinga/Finolex
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. Make AKG/NIC/BEC
Supplying and fixing 5A to 32A rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following tables in the existing MCB DB complete with connections, testing and commisioning etc. as required. Make Havells/Standard/C&S/ABB
(a) Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make Standard/ Havells/C&S/ABB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
(a)12 way , Double door make Havells / Standard / C&S/L&T/ABB
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make Anchor Roma/Great White/Legrand
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch switch
6 pin 15/16 A socket outlet
Blanking plate
Telephone socket outlet
RJ 45 Computer jack with shutter
32 amp DP One way switch
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. Make Make Anchor Roma/Great White/Legrand
1/2 Module
3 module
4 module
6 Module
8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. Make Make Anchor Roma/Great White/Legrand
1/2 Module
8 Module
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying Installation Testing Commissioning of 400 mm (16") sweep wall Fan including fixing of base plate etc as required. Make of CG/Bajaj/havells
Supplying, installation, testing and commissioning of 1200mm sweep ceiling fan, including nut bolts etc. complete as required. make Havells model Pacer or equivalent of Bajaj/CG
Providing and fixing of 2' x 2' LED slim light along with driver ceilling mounting, recessed type, 34/36 Watt 3000/6000 K, complete with connection, testing etc. as reqd. make Havells Endura slim pro plus or equivalent of Bajaj/CG/Philips
Providing and fixing of suitable size fan hook including nut bolts packing arrangements etc complete as required on site.
Providing and fixing of fan rod size 2 feet including nut bolts etc complete as required.
Supplying, installation of 250mm fresh air/ventilating fan plastic body with louvers/ shutters complete with frame in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Make havells Model no. Ventil Air - DX White or equivalent of Bajaj/CG
Supplying and fixing of powder coated M.S. stand suitable for outdoor unit of 2.0/1.5 Ton Split/ Cassette type air conditioner complete as reqd.
Providing and fixing inner outer copper tube pipe suitable size including i/c insulation, testing, making connections etc as required.
Providing and fixing of 16 Amp top plug including making connection etc complete as required. Make Anchor
Dismantle Installation of 1.5 Ton, Split Air conditioner complete with outdoor unit and all connecting accessories as a unit etc as reqd
Supplying ,Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Make Havells/kalinga/polycab size- 2 x 25 sqmm
Supplying and installation of 1.5 Ton, Split Air conditioner (5 Star) inverter complete with outdoor unit complete as a unit as reqd. Make- Hitachi / O-general/Daikin/Voltas/LG/LLOYD/Bluestar
Maa Durga Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .