Tender Value
₹26.0 L
EMD Value
₹51,940
Closing Date
11 Dec 2025, 5:00 pmClosed
SE CIVIL RRVPNL BIKANER
66/11 KV GSS SANGALPURA BIKANER
Civil work for 40 50 MVA TRF II AT 132 KV GSS SRIGANGANAGAR
2025_RRVPN_516318_2
RVPN/SE/CIVIL/BKN/2025-26/NIB 13/1
Open Tender
Civil Works
180 days
132 KV GSS SRIGANGANAGAR
please refer NIB 13 and bid document
2 documents required · 2 mandatory
₹2,950
ACCOUNTS OFFICER T AND C RRVPNL HANUMANGARH
₹51,940
Yes
26 Dec 2025
1 Dec 2025
12 Dec 2025
1 Dec 2025
11 Dec 2025
1 Dec 2025
Amount
Supply & Fixing 30mm thick ferro cement RCC cable trench covers up to span 1 200mm, C:C grade M-30 having outer frame of M S. flat 30x3 mm and reinforcement consisting of 6mm dia M.S. round bar both way at the spacing of 8 to 10 cm C/C as required to adjust the spacing welded with outer frame and binding with binding wire in middle with two layers of G.I. wire mesh 12mm shape of 24 gauge including proper quantities of concrete additional admixture like pl asticizer, bond improving compound etc. manufacture with vibro pressing system, 20% cover shall have lifting hooks of I0mm dia plain round bar to be fixed as directed. M.s flat/hooks exposed shall be painted with two coats of superior quality corrosion resistance paint. The above covers shall to fake for live load of 2000 kg/sqm and minimum ultimate load of 3000 kg/sqm under defection not exceeding L/25. (excluding GST and inclusive of transportation charges).
Labour charges for collection of existing spreaded 20- 63mm nominal size Handl Crusher broken stone aggregate of any thickness from substation yard by manual I mechanical means, as permitted by the Engineer in charge, with due care, as per safety norms of substation. This aggregate should be screened & stacked properly. Then this screened aggregate shall be laid in 100mm thick layer in yard as directed, with due care with all lead,Uft.(payment shall be done as per stack measurement, after deduction of voids, as per norms).As per approved by CE civil RVPN jaipur vide letter no. D.1091 Dated 09.08.2019
approved item rate by CE civil Labour charges forspreading of 20-63 mm nominal size hand/crusher broken stone aggregate in uniform layer of 100 mm thickness in yard any substation charged uncharged yard by manual/mechnical means as permitted by engineer in charge with due care of safety norms of substation complete in all respect
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
bidsgnr132trf.pdf
Tender Documents • 5.64 MB
BOQ_921258.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid