Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-Finance D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | ₹34.5 L | L1 | Accepted-Finance BEING LOWEST BIDDER |
| 2 | L2₹51.0 LRejected-Finance | ₹51.0 L | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RP ANAND L1 | M/s Ajayshwar Singh Rana L2 |
|---|---|---|---|---|---|
| 1.00Taking down centrifugal pump set from existing foundation by disconnecting electrically and mechanically at different locations, transporting it to the workshop, dismantling the pumps & carrying out for repair / maintenance cleaning of inside pump, oiling, greasing, gland packing & for proper alignment including replacement of un-serviceable parts with new ones and refixing existing location after got repaired maintenance / replacement of parts, re-assembling on foundation including replacement of nut, bolt and washers fixing in existing position commissioning and testing including loading / unloading, transportation to and from workshop for pumps of following capacity of any size:- Note : (a) The cost of transportation such as vehicle, T & P and man power deemed to be included in the rate quoted by the contractor. (b) Winding shall be measured and paid separately. (c) Supply only spare parts as mentioned in here-in-after shall be measured and paid separately. | |||||
| 1.01 | (a) 100 HP | 5 | Each Job | 5,000 ₹25,000 | 2,500 ₹12,500 |
| 1.02 | (b) 60 HP to 75 HP | 3 | Each Job | 4,000 ₹12,000 | 2,500 ₹7,500 |
| 1.03 | (c) 25 HP to 40 HP | 2 | Each Job | 3,500 ₹7,000 | 2,200 ₹4,400 |
| 1.04 | (d) 7.5 H to 15 HP | 3 | Each Job | 3,000 ₹9,000 | 1,500 ₹4,500 |
| 1.05 | (e) 3 HP to 5 HP | 2 | Each Job | 2,000 ₹4,000 | 1,000 ₹2,000 |
| 2.00Taking Down centrifugal pump set from existing foundation and M & L for dismantling of centrifugal motor after disconnecting electrically and mechanically, transporting to workshop for Comprehensive repair and maintenance including loading/unloading and reassembling after necessary repair and rewinding the motor stator/rotor with supper enameled copper winding wire of existing size, gauge and turns etc including Spare parts, all the insulating material i.e. varnish, supper high quality cotton tape, insulating paper or soldering etc. including drying up to desired temperature for specific time complete all as specified and directed by Engr-in-Charge for the following capacity of any size :- Note : (a) Rewinding warranty of centrifugal pump shall be of 06 months from installation (b) UNSV PUMP/ Motor should be attend on the same day and re installed within 48 Hours incl Sunday and holyday when and after intimation for failure of motor (c) A recovery Rs 1000 per day for Late Installation/ not attend the centrifugal motor | |||||
| 2.01 | (a) 100 HP | 2 | Each Job | 50,000 ₹1 L | 36,500 ₹73,000 |
| 2.02 | (b) 60 HP to 75 HP | 2 | Each Job | 30,000 ₹60,000 | 36,000 ₹72,000 |
| 2.03 | (c) 25 HP to 40 HP | 2 | Each Job | 15,000 ₹30,000 | 35,000 ₹70,000 |
Updated dates
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 Mar 2026, 6:00 pmClosed
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR - 482001
REPAIR AND MAINT OF WATER SUPPLY PUMPING SETS, LT PANELS, RELATED DISTRIBUTION SYSTEM AND ALLIED WORKS OF AGE EM UNDER GE (WEST) JABALPUR
2026_MES_753038_1
81167/E8
Open Tender
Civil Works - Water Works
180 days
JABALPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE (WEST) JABALPUR
₹96,000
Yes
1 Jun 2026
17 Feb 2026
6 Apr 2026
17 Feb 2026
30 Mar 2026
11 Mar 2026
17 Feb 2026 - 10 Mar 2026
Taking down centrifugal pump set from existing foundation by disconnecting electrically and mechanically at different locations, transporting it to the workshop, dismantling the pumps & carrying out for repair / maintenance cleaning of inside pump, oiling, greasing, gland packing & for proper alignment including replacement of un-serviceable parts with new ones and refixing existing location after got repaired maintenance / replacement of parts, re-assembling on foundation including replacement of nut, bolt and washers fixing in existing position commissioning and testing including loading / unloading, transportation to and from workshop for pumps of following capacity of any size:- Note : (a) The cost of transportation such as vehicle, T & P and man power deemed to be included in the rate quoted by the contractor. (b) Winding shall be measured and paid separately. (c) Supply only spare parts as mentioned in here-in-after shall be measured and paid separately.
(b) 60 HP to 75 HP
(c) 25 HP to 40 HP
(d) 7.5 H to 15 HP
(e) 3 HP to 5 HP
Taking Down centrifugal pump set from existing foundation and M & L for dismantling of centrifugal motor after disconnecting electrically and mechanically, transporting to workshop for Comprehensive repair and maintenance including loading/unloading and reassembling after necessary repair and rewinding the motor stator/rotor with supper enameled copper winding wire of existing size, gauge and turns etc including Spare parts, all the insulating material i.e. varnish, supper high quality cotton tape, insulating paper or soldering etc. including drying up to desired temperature for specific time complete all as specified and directed by Engr-in-Charge for the following capacity of any size :- Note : (a) Rewinding warranty of centrifugal pump shall be of 06 months from installation (b) UNSV PUMP/ Motor should be attend on the same day and re installed within 48 Hours incl Sunday and holyday when and after intimation for failure of motor (c) A recovery Rs 1000 per day for Late Installation/ not attend the centrifugal motor
(b) 60 HP to 75 HP
(c) 25 HP to 40 HP
(d) 7.5 H to 15 HP
(e) 3 HP to 5 HP
Material & Labour for painting of centrifugal pump set with one coat of synthetic enamel paint of approved colour or shade as approved by Engineer-in-Charge including preparation of surface after removing existing paint & filling depressions complete all as specified & directed by Engr-in-Charge including writing of SM No and MES No on the pump set for the following capacity:-
(b) 60 HP to 75 HP
(c) 25 HP to 40 HP
(d) 7.5 H to 15 HP
(e) 3 HP to 5 HP
Supply only of following parts for Centrifugal pump set of capacity 100 HP :-
(a) Ball bearing for motor of existing size
(b) Ball bearing for pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(f) Coupling complete of existing size
(g) Pump shaft including key
(h) Rubber bush including nut bolt and washer complete
(j) Sleeves
Supply only of following parts of Centrifugal pump set of capacity 60 to 75 HP :-
(a) Ball bearing for motor of existing size
(b) Ball bearing for pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(f) Coupling complete set of existing size
(g) Pump shaft including key
(h) Rubber bush including nut bolt and washer complete
(j) Sleeves
Supply only of following parts of Centrifugal pump set of capacity 25 to 40 HP :-
(a) Ball bearing for motor of existing size
(b) Ball bearing pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(f) Coupling complete set of existing size
(g) Pump shaft including key
(h) Rubber bush including nut bolt and washer complete
(j) Sleeves
Supply only of following parts of Centrifugal pump set of capacity 7.5 to 15 HP :-
(a) Ball bearing for motor of existing size
(b) Ball bearing pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(f) Coupling complete set of existing size
(g) Pump shaft including key
(h) Rubber bush including nut bolt and washer complete
(j) Sleeves
Supply only of following parts of Centrifugal pump set of capacity 3 to 5 HP :-
(a) Ball bearing for motor of existing sizes and make.
(b) Ball bearing pump set of existing size
(c) Glands bush
(d) Neck Ring
(e) Coupling complete set of existing size
(f) Pump shaft including key
(g) Rubber bush including nut bolt and washer complete
(h) Sleeves
Taking out Submersible Pump Set of different capacity at different locations along with Column pipe of 80 to 100 mm bore with Submersible cable from the bore well of depth ranging from 30 Mtr to 90 Mtr and transporting it to work shop for dismantling / opening for repair & taking out unserviceable parts of capacity 5 to 35 HP including loading / unloading and transportation to and from work shop complete all as specified and as directed. Note : Supply only of spare parts shall be measured and paid separately
Lowering and re-fixing of submersible pump set of 5 HP to 35 HP at different locations including pump set installation, commissioning and testing after repair & replacement of un-serviceable parts with existing column pipe 80/100mm bore with existing serviceable cable including tightening of rope to the pump by suitable arrangement of chain pulley system and connection with starter electrically and connection with pipe line mechanically complete all as specified and as directed.
M & L for rewinding the subersible motor stator/rotor with supper enameled copper winding wire of existing size and gauge and turns etc including all the insulating material i.e. varnish, supper high quality cotton tape, insulating paper or soldering etc. including drying up to desired temperature for specific time complete all as specified and directed by Engr-in-Charge of the following capacity of submersible pump:- Note : (a) Rewinding warranty of submersible pump shall be of 06 months. (b) UNSV PUMP/ Motor should be installed within 24 Hours when and after intimation for failure of motor (c) A recovery Rs 1000 for Late Installation of pump (d) Before installation of motor / Pump, it should be ensure that all unsv spare parts of Motor / Pump as given below are replaced (e) Spare parts shall be measure and paid separately.
(c) 20 HP to 22.5 HP
(d) 15 HP to 17.5 HP
(e) 5 HP to 12.5 HP
S & F in repairs following parts of Submersible Motor 5 HP to 35 HP capacity suitable for any size of dia:-
(a) Motor bearing bush
(b) Motor base complete
(c) Motor base plate
(d) Bearing Upper Housing
(e) Bearing Lower Housing
(f) TB axial
(g) RT Disc
(h) Upper/ lower Flange
(j) Cable joint
(k) Starter Circlip
(l) Rotor circlip
(m) Motor Coupling
(n) Rotor sleeve
(o) Water seal 'O' Ring
(p) Upper/Lower Flange stud
(q) TB Housing
(r) Adopter stud
(s) Water seal
(t) T Bolt upper/ lower
(u) Stud O Ring
(v) Sand guard
(w) Pressure cup equalizer
(x) Rocker
(y) Coupling Key
(z) C I Bearing
(aa) Cable clip
(ab) Drain plug
(ac) Stud
(ad) Balancing ring
(ae) Rotor nut
S & F in repairs following parts of Submersible Pump 5 HP to 35 HP capacity suitable for any size of dia :-
(a) Neck Ring
(b) Bearing bush
(c) Bearing sleeve
(d) Impeller
(e) Stage Casing
(f) Suction Housing
(g) Distance sleeve
(h) Pump Coupling
(j) Locking screw
(k) Stainer
(l) DOL bush
(m) DOL Sleeve
(n) Distance bush
(o) Body Nut
(p) Body stud
(q) Pump Shaft
(r) Pump Shaft Key
(s) Intermediate piece
(t) Intermediate sleeves
(u) Suction housing bush
(v) Stem
(w) NRV body
M&L for Rotor Machining, Grinding & balancing of 5 HP to 35 HP capacity Pump set complete all as specified and as directed.
M&L Impeller Machining & Balancing of 5 HP to 35 HP capacity pump set complete all as specified and as directed.
M & L for replacement of rotor of the submersible motor 3 phase 415 Volt 50 Hz AC for following capacity:-
(c) 20 HP to 22.5 HP
(d) 15 HP to 17.5 HP
(e) 5 HP to 12.5 HP
M& L for replacement of stator of the submersible motor 3 phase 415 volts 50 Hz AC for following capacity of any size :-
(c) 20 HP to 22.5 HP
(d) 15 HP to 17.5 HP
(e) 5 HP to 12.5 HP
Supply, lifting and lowering in repair/replacement of GI Heavy duty column pipe 100mm (4" bore), 3 Mtr long , ISI marked with 100mm long threaded socket heavy duty for lowering of submersible pump in bore well complete all as specified and as directed.
Supply, lifting and lowering in repair/replacement of GI Heavy duty column pipe 80mm (3" bore), 3 Mtr long , ISI marked with 100mm long threaded socket heavy duty for lowering of submersible pump in bore well complete all as specified and as directed.
Cutting and threading 80mm (3" bore) both end MS / GI column pipe heave duty 3 Mtr long including heavy duty new socket 80mm bore 100 mm long complete all as specified and directed.
Cutting and threading 100mm (4" bore) both end MS / GI column pipe heave duty 3 Mtr long including heavy duty new socket 100mm bore 100 mm long complete all as specified and directed.
S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 4 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990 including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed.
S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 6 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990 including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed.
S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 10 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990 including jointing, connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate size as in thrust block / support pillar for pipe holding with MS clamps 50 x 6 mm including finishing the concrete surface fair and even with out using extra cement making good to disturbed surfaces complete all as specified and as directed.
M&L for fittings for spigot socketed cast iron pipes 80 to 300mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs complete all as specified and as directed.
M & L for MS clamps for suitable sizes from flat iron/ structural steel sections as per site requirement including nuts, bolts, washers, welding, bending cold or hot, drilling holes bolts, sockets etc any shape or size complete all as specified and as directed.
Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-20 mortar, 28 to 42 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 15 to 22.5 HP submersible pump)
Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-30 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 25 HP Submersible pump)
Supply, install, test and commissioning in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MUG-40 mortar, 30 to 50 Amp relay max. range rating AC 3 Phase 415 Volt 50 HZ conforming to IS/ IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON/ OFF voltage and Ampere complete all as specified and as directed. (Suitable for 35 HP Submersible pump)
S & F in repair/replacement of DOL starter 240/ 415 volt suitable for 3 to 10 HP motor pump set as per requirement at site complete all as specified and as directed.
Supply & testing in repair/replacement of submersible pump starter fully automatic star delta starter in sheet metal enclosure type MN 110F motor, 30-50 Amp relay max range rating AC 3 phase 415 Volt 50 Hz conforming to IS / IEC : 60947-41 protection offered overload single phasing, phase reversal, phase imbalance, auto restart features vibration proof enclosure with IP-54 protection class indications offered ON / OFF Voltage and ampere complete all as specified & directed.
(a) Roller assembly (PK-4)
(b) Pump tube (PK-5)
(c) Weighted suction line strainer 3/8"
(d) 3/8" white suction / discharge tube
(e) Check valve duckbill only (PK-5)
(f) Connecting nut 3/8"
(g) connecting nut 3/8" with adapter (PK-5)
(h) GI fitting for Doser including gate valve
(j) NRV suitable for Decrin Dozer
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed.
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed.
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed.
Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all as specified & directed.
S&F in repair testing and commissioning PVC unsheathed flexible copper cable 1100 volts grade of size 2.5 Sqmm (three runs of single core). Complete all as specified and as directed
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheeting of PVC tape and overall PVC sheathed in service connection, twin core 10 Sqmm stranded aluminum conductor cable flat or circular complete including dismantling of existing service connection all as specified and directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe with funnel along with wire mesh, including 40mm dia GI pipe medium grade [Minimum 5 m in length] for protection of GI earth wire, including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm dia TMT steel bars spacing @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
S & F in repair earth continuity conductor or main earthing lead with galvanized iron strip of size 32 x 6 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in pipe or any other indicated location for loop earthing etc as required complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole 63 Amps, 415 volts adjustable type with breaking capacity 16KA on LT panel/feeder pillar box etc complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole 100 Amps, 415 volts adjustable type with breaking capacity 16KA on LT panel/feeder pillar box etc complete all as specified and directed
Supply and fixing in repair MCCB 4 pole 160 Amps, 415 volts adjustable type with breaking capacity 36KA on LT panel/feeder pillar box etc complete all as specified and directed
Supply and fixing in repair MCCB 4 pole 250 Amps, 415 volts adjustable type with breaking capacity 36KA on LT panel/feeder pillar box etc complete all as specified and directed
Repair / Servicing of LT panel board with starter all model MUG of L&T of submersible pump in each pump house including making fresh connections of cables, new lugs, painting of LT panel, cleaning etc complete all as specified & as directed
Collect & Testing of water sample obtained in bore wells / swimming pool from Authorised Test Laboratory and submit the test report for record purpose complete all as specified and as directed by Engr-in-Charge. Testing criteria of water as follows :- Colour, Hazen unit -5, Odour- unobjectionable, Taste- Agreeable, Turbidity, NTU- 5, pH Value- 6.5 to 8.5, Hardness- 300PPM, Iron- 0.3mg/l, Chloride-<=250mg/l, Fluoride<= 1.0mg/l, Residual chlorine<=0.2mg/l, Total Dissolved Solid -263mg/l
Supply & Fixing in replacement of terminal plate with 06 Nos copper lugs suitable for 35/50 Sqmm copper cable 3.5 core for 100 HP pump set complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan, in soft and loose soil and getting out for foundation, trenches or laying of electric cable or pipes complete all as specified & directed.
Returning, filling in, excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of excavated materials (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
S & F of DWC Pipe IS-16205, outer dia 50 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed.
Supply and fixing of High intensity HIP reflective sign board made from hardened plastic aluminium combined sheet 2 mm thick (with high quality lamination), two sheets placed back to back aluminium pop riveted to stainless steel square pipe 40 x 40 mm of 16 gauge, frame of size 1300 x 840 mm. Frame supported with 25 mm and 50 mm round 2700mm long stainless steel pipe of 16 gauge welded to frame. Top end of legs closed with decorative stainless steel dome place. All stainless steel parts polished on plastic aluminium combined sheet, HIP blue reflective sheet shall be pasted on both side and with white fluorescent computer cut tape minimum 110mm height to be pasted on sign board and border of white HIP sheet shall be pasted and fixed in PCC (1:2:4) type B1 including dismantling existing old vintage damaged standing sign board, complete all as specified and directed by Engr-in-Charge.
S&F in repair change over switch 4 pole 100 Amp, 415 Volts, Onload type, front handle type with enclosure including connection and testing complete all as specified and directed.
S&F in repair change over switch 4 pole 200 Amp, 415 Volts, Onload type, front handle type with enclosure including connection and testing complete all as specified and directed.
Dismantling of existing valve pit and M&L for construction of masonry valve pit with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 120cmX120cmX3mm MS sheet for cover, angle iron 50cmx50cmx6mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Dismantling of existing valve pit and M&L for construction of masonry valve pit with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1000 x 1000x1000 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 100cmX100cmX3mm MS sheet for cover, angle iron 50cmx50cmx6mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
M&L in replacement of control wiring / motor starter wiring of pump motor starter panel with PVC insulated copper contactor of sizes 4/6/10/50/70 sqmm all as specified and directed.
S&F in replacement of MS Nut bolts machine made with hexagonal or square head at one end screwed the other, each screws and to be fitted with washers and nut, exc 5 cm but not exc 10 cm long and dia of bolt 10cm complete all as specified and directed.
M&L in replacement for MS tail piece 6" dia length required on site both end flanged with nuts bolt and rubber flanged complete all as specified and directed.
M&L for Repair to pump house bore well cap cover made out from mild steel sheet 3 mm thick and angle iron frame in any shape and size complete with making holes , nut bolts welding etc as reqd at site including painting of two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M & L in replacement CI non return valve of bore 150 mm dia ,ISI marked complete all as specified and as directed
M & L in replacement CI non return valve of bore 100 mm dia ,ISI marked all as specified and directed
M& L of repairing/ welding of pipe/ fitting of size 80 to 200mm including excavation in soft/dense soil & taking up pipe/fitting of size 80 to 200 mm dia GI/PVC cutting, rethreading/jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the joint. Note:- Necessary Excavation upto 0.60 cum shall be included in the job complete all as specified and directed.
S&F in replacement of the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by engr-in- charge
(a) 200mm bore sluice valve
(b) 150mm bore sluice valve
(c) 100mm bore sluice valve
(d) 80mm bore sluice valve
M&L in replacement Gun metal globe/gate valve (ISI Marked) with iron wheel head, screwed both ends for pipes or for unions for 50mm bore dia steel tubing complete all as specified and as specified and as directed .
-ditto- above, but for 40 mm bore complete all as specified and as specified and as directed .
-ditto- above, but for 25 mm bore complete all as specified and as specified and as directed .
-ditto- above, but for 20 mm bore complete all as specified and as specified and as directed .
M & L in replacement for gland packing of suitable size of existing sluice valve of size 3", 4", 6", 8" & 10" complete all as specified and as specified and as directed (Each roll of 6 pieces) .
M&L in replacement for chlorine test kit with coloured sample complete with all testing fitments and OT solution in rexene finish box complete all as specified and as directed.
Supply only OT solution for chlorine test 500 ML bottle complete all as specified and as directed.
S&F rubber gasket joint for flanged end pipe & fittings of size 80mm dia to 200mm dia complete all as specified and as directed .
M&L for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees up to zero level not exceeding 30 cm girth and removing rubbish up to distance of 50 mtr out the periphery of area under cleanness complete with tractor/JCB plants/ Manpower complete all as specified and as directed.
M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed.
M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pig of 200 mm dia/bore pipe, complete all as specified and as directed
M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pig of 150 mm dia/bore pipe, complete all as specified and as directed
M&L in replacement Run lead joint complete with spun yarn packing & filling properly with lead pig of 100 mm dia/bore pipe, complete all as specified and as directed
S&F in replacement of U/S electronic timers 380/415V, 50Hz range 3-10, 9-30, 30 -120 sec complete all as specified and directed. (Suitable for 15 to 35 HP Submersible Pump set)
S&F in replacement of U/S Volt meter / Ampere meter as suitable existing approx CT ratio-100/5 & 30/5 complete all as specified and directed .(Suitable for 15 to 35 HP Submersible Pump set)
S&F in replacement of U/S LED indicator lamp (Green, Red, Yellow ) 220V 50Hz complete all as specified and directed.(Suitable for 15 to 35 HP Submersible Pump set)
S&F in replacement of U/S ON/OFF push button complete all as specified and directed .(Suitable for 5 to 35 HP Submersible Pump set)
S & F Power contactor MU 2, 3 pole rating not less than 32 A with 230 coil complete all as specified. (Suitable for 15 HP to 22.5 HP Submersible Pump set)
S & F Power contactor ML-2, 3 pole rating not less than 40 A with 230 coil complete all as specified. (Suitable for 25 HP to 35 HP Submersible Pump set)
S & F Power contactor MNX 110 , 3 pole rating not less than 100 A with 415V complete all as specified. (Suitable for 60 HP to 75 HP Centrifugal Pump set)
S & F Power contactor MNX 140 , 3 pole rating not less than 100 A with 415V complete all as specified. (Suitable for 100 HP Centrifugal Pump set)
S&F thermal protection overload RELAY with built in earth fault relay, 20 to 32 amp, 230/415V coil complete all as specified. (Suitable for 15 HP to 22.5 HP Submersible Pump set)
S&F thermal protection over load RELAY with built in earth fault relay , 28 to 45 amp, 230/415V coil complete all as specified. (Suitable for 25 to 35 HP Submersible Pump set)
S&F Thermal protection over load RELAY with built in earth fault relay, 66 to 110 amp, MN5 up to 500V complete all as specified. (Suitable for 60 HP to 100 HP Centrifugal Pump set)
M & L in replacement Foot valve of bore 80-100 mm dia, ISI marked including all fitting , nut , bolt etc complete all as specified and directed
M & L in replacement Foot valve of bore 150 mm dia, ISI marked including all fitting , nut , bolt etc complete all as specified and directed .
S & F in repairs aluminium cable lugs of size 3.5/4 core, 16 sqmm to 120 sqmm complete all as specified and directed.
Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and directed:- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
(a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming)
(b) MCCB FP 40 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 02 Nos (outgoing)
(c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)
(d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No
(e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 02 Nos
(f) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP centrifugal Pump set, 3 Phase - 02 Nos
(g) Single phase preventer, over load relays of suitable rating - 02 Nos
(j) Indicator lamp LED type - 3 Nos (R, Y & B)
Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and directed:- Note:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires
(a) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming)
(b) MCCB FP 40 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing)
(c) MCB TPN 20 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 01 No (outgoing)
(d) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)
(e) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No
(f) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No
(g) Fully automatic Motor Starter (Star-Delta) suitable for 25 HP submersible Pump set, 3 Phase - 01 No
(h) Single phase preventer, over load relays of suitable rating - 01 No
(k) Indicator lamp LED type - 3 Nos (R, Y & B)
Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and directed:- Note:- 1. Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires 2. Panel board shall be manufactured from CPRI approved manufacturers only. 3. Platform for panel should be 1.5 feet above average ground level. 4. Connecting of existing UG cable to panel board as per site requirement.
(a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming)
(b) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing)
(c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)
(d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No
(e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No
(f) Fully automatic Motor Starter (Star-Delta) suitable for 35 HP submersible Pump set, 3 Phase - 01 No
(g) Single phase preventer, over load relays of suitable rating - 01 No
(j) Indicator lamp LED type - 3 Nos (R, Y & B)
Supply, install, testing and commissioning in repleacement of LT Feeder pillar Box, AC, 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron (50 x 50 x 5 mm) frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, duly powder coated with 100A electrical grade copper bus bar for phases and neutral with colour coated insulator sleeves, including danger notice plate complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all including the following incoming complete all as specified and directed:- Note:- 1. Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires 2. Panel board shall be manufactured from CPRI approved manufacturers only. 3. Platform for panel should be 1.5 feet above average ground level. 4. Connecting of existing UG cable to panel board as per site requirement.
(a) MCCB FP 125 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA, adjustable type - 01 No (Incoming)
(b) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 01 No (outgoing)
(c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 01 No (outgoing)
(d) On load change over switch, 4 Pole, 160 Amps, 415 Volts - 01 No
(e) Surge Protection Device (SPD), Three Pole and Neutral, Uc (V) 320 V, In (Ka) 20 kA, Imax (kA) 40 kA - 01 No
(f) Fully automatic Motor Starter (Star-Delta) suitable for 60 HP centrifugal Pump set, 3 Phase - 01 No
(g) Single phase preventer, over load relays of suitable rating - 01 No
(j) Indicator lamp LED type - 3 Nos (R, Y & B)
M & L for painting with approved colour to existing MS/GI pipe (raising main delivery over flow and wash out) of size 80/100/150/200mm dia with two coat of synthetic enamelled paint over a coat of red oxide primer including scrapping out old paint all as specified and directed. Note:- All T & P, 30 mtr staging mtrl and men power risk shall contractor responsibility.
Taking down steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors, in old/new situation for bore of pipe following sizes: -
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
(g) 100 mm dia
S & F steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors, in old/new situation for bore of pipe following sizes: -
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 50 mm dia
S & F steel water tubing galvanised, medium grade with all fittings and laid in trench in old/new situation for bore of pipe following sizes: -
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
(g) 100 mm dia
Supply and laying well burnt sub class B bricks, old size bricks, laid flat dry, in trenches with width of the bricks layed to the axis of cable for cable protection complete all as specified and directed
Supply and spreads river sand for cable cushing in trenches all as specified in clause 19.75 of SSR Part 1
Schedule of credit amount of Rs 174220.00 to be deducted during AOC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender_81167.pdf
Tender Documents • 2.25 MB
BOQ_843448.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid