Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹43.7 L+₹2.1 L (5.11%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest | |
| 3 | L3₹44.4 L+₹2.8 L (6.75%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance Being other than Lowest | |
| 4 | L4₹46.0 L+₹4.5 L (10.8%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L4 | Rejected-Finance Being other than Lowest |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
5 Oct 2021, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR ROUTINE MAINT OF 18 NOS ELECTRIC LIFTS (MAKE ESCON) (G Plus 14 STOREY BLDG AT NAVY NAGAR UNDER GE (NW) NAVY NAGAR COLABA MUMBAI (2ND CALL)
2021_MES_460533_2
8236/CWE(NW)MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (NW) Navy Nagar
Class D
8 documents required · 8 mandatory
₹500
Yes
GE (NW) Navy Nagar
₹77,000
Yes
23 Oct 2021
16 Sept 2021
7 Oct 2021
16 Sept 2021
5 Oct 2021
23 Sept 2021
16 Sept 2021 - 22 Sept 2021
Amount
Part-1 Repair/maintenacne of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan , ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the following lifts:- Note 1: - (i) Two mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (ii) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department.(iii) The detailed duty mechanics of the firm shall report to the JE Concerned at the Lift complaint cell i.e. R-12 building . New Navy Nagar for receiving the complaints at round the clock daily including sunday and holiday.(iv) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. Note 2.:- Rate deemed to be inclusive of Inspection of lift by PWD twice in a contrat period.
13 PS lifts (884 Kgs ) in bldg (G+14) R-4, R-5, R-7, R-11'A' & 'E' Wing, R-13, R-25'A' & 'E' Wing (Total 08 Nos lift).
8 PS (544 Kg) capacity G+14 storey Makar, Kumbha, R-11'A' wing, R-22'A' & 'E' wing, R-25 'A' & 'E' Wing (Total 07 Nos lift).
29 Passengers ( 2000 Kg) capacity in bldg(G+14) R- 17, R-18, R-19 ( Total 03 Nos of lift )
Note : - (i) The Contractor has to carry out the AMC of the Lifts through OEM only (ii) The AMC should cover any/all parts of Lifts if its fucntions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (iii) One mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (iv) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (v) The detailed lift mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including sunday and holiday. (vi) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. (vii) Cost of minor spare parts / routine material required for above mentioned maintenance is deemed to be included in the quoted rate except items mentioned here-in-after. No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material (viii) Monthly schedule for proper maintenance of lift and necessary documentation including all spare parts required to be replaced during the period shall be as directed by Engineer-in-Charge. (ix) All minor spare parts and parts required for repair / replacement for maintenance of lifts to be replaced during AMC at no extra payment. (x) Bidders are to submit license from Govt. of maharashtra for maintenace & erection of lifts issued by chief electrical inspector.
Part II Disconnecting and taking out unserviceable COP assembly, Supply and fix new assembly complete with illuminated push button for floor position, alarm, non stop door open, door close, cabin fan, cabin light stop, attend out key etc with direction indicator with LED display with CPI card of stainless steel face plate in and including necessary wiring for illuminating push button complete all as specified and directed by Engineer-in-Charge for G+14 Storey buildings,Lifts.
Replacement of unserviceable cabin fan from car cabin, supply and fix, new cabin fan, non-oscilating type, axial flow, single speed 300mm sweep, 240 volts ISI marked with grill complete all as directed by Engineer-in-Charge.
Disconnecting and taking out old/unserviceable shaft wiring, supply and fixing of shaft wiring in hoist way upto lower limit with PVC insulated copper conductor cable single core, 1100 Volts grade 0.75 Sqmm 24 Nos single core & 1.0 Sqmm for earth wire duly bunched with wire binding locking strip, drawing through in and including galvanished sheet metal trucking of 24 SWG up to ground floor in hoist for control to all function including in built connection for control panel, PCB, Hall push button, fire switch and lower limit switch all as specified and directed by the Engineer-in-Charge. for G+14 Storey building.
Dismatling and taking out unserviceable old control panel and control wiring and supply and fix new CAN BAS Integrated Drive based collectice control panel in hinged MS powder coated cabinet with control wiring comprising with multiple microcontrolled programmed chip based controlled by pulse modulation, complete with all safties such as thermal overload protection, over current protection, auto phase reverse link to each other in net work and compitable to 11 KW/15HP capacity VVVF drive including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc complete all as specified and directed by Engineer-in-Charge. Location :- R-5 (13PS). G+14 story. Make _ ESCON
Disconnecting and taking out defective unserviceable main drive (any type) from existing control panel and supply and fixing CAN BAS Integrtaed drive suitable for 13 Ps lift G+14 storey building complete with all electric connection. Make : ESCON. Location :- R-5 Bldg.
Disconnecting and taking out defective dynamic breaking resistence from controller and supply and fixing new aluminium covered wire wound dynamic breaking resistor to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for 11.0KW/15HP motor. R-5 Bldg
Dismatling and taking out unserviceable old control panel and control wiring and supply and fix new CAN BAS Integrated Drive based collective control panel in hinged MS powder coated cabinet with control wiring comprising with multiple microcontrolled programmed chip based controlled by pulse modulation, complete with all safties such as thermal overload protection, over current protection, auto phase reverse link to each other in net work and compitable to 18 KW/24HP capacity VVVF drive including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with suitable size of stranded copper cable etc complete all as specified and directed by Engineer-in-Charge. Location :- R-18 (29PS). G+14 story. Make _ ESCON
Disconnecting and taking out defective dynamic breaking resistence from controller and supply and fixing new aluminium covered wire wound dynamic breaking resistor to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for 18.0KW/24HP motor. R-5 Bldg
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc complete all as directed by Engineer-in-Charge.in 8/13 /Goods Lift, G+5/G+6/G+14 Storey buildings.
Disconnecting and taking out old/unserviceable Governer rope of size 8 mm dia(8/19 Construction) ungalvanised including necessery connection with pully in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13/Goods lifts
Disconnecting and taking out old/unserviceable travelling cable from hoist way and supply and fix new travelling cable PVC Insulated 16/24 Core with stranded copper conductor, 1100 volts grade of size 0.75 Sqmm conforming to relevant IS including criping with lugs appropriate thimples complete all as specified and directed by Engineer-in-Charge.Make:- Polycab/Finolex
Dismantling and taking out gear box assembly from main machine for repairs/replacement of unserviceable/wornout parts such as worn wheel, worn shaft bushes, thrust bearing and pedest al bearing and necessary packing including overhauling, cleaning alignment of gear box assembly and after repairs/repalcement of wornout part assembly and refixing with existing machine with proper alignment and testing complete etc all as specified and directed by Engineer-in-Charge, for G+14/G+6 storey Bldg,
Dismantling and taking out unserviceable safety edge of any type & supply and fixing new full beam infrared sensor upto full length of car doors (2.00 mtr) as specified and directed by the Engineer-in-Charge. Make :- TLJONES/WECO as approved
Replacement of automatic door drive unit with motor on car top with VVVF of 1 HP capaicity all as specified and directed by Engineer-in-Charge. Make :- Yasakawa / Schneider as approved by Engineer- in-Charge
Dismantling and taking out unserviceable old Landing push button box along with illuminated call button with controll wiring supply & fix Landing push button box along with illuminated call button with digital arrow indication with controll wiring, for G+14/G+5/G+6 storey building complete all as directed by Engineer-in-Charge.
Taking down and supply and fix hooter with emergency call announciator working on 12 Volts with audibility 90DB @ 50M distance with complete accessories and alongwith box including connecting cables
Taking down old UNSV Announcement system and supply and install, testing and commissioning of MP3 voice announcement system in the controller and high quality speaker on car top, with necessery provision of shaft wires and travelling cable complete as specified. The audio indicator shall anounce floor position, ARD made operation, overload announcement etc and continious mild music in hindi and can be programmable for more music. The announcement system shall be in hindi and english.
Taking down old unserviceable OSG Pully from the position and supply and fix New OSG Pully both top and bottom for 8 & 13 Ps Lift as specified and directed by Engr-in-Charge. Make - ESCON. Location :- R-11A&E Wing & R-22 A & E Wing, R - 25 A Wing
Taking down old unserviceable False ceiling and supply and fix new false ceiling made out of stainless steel hair line finish 1.2mm thick and fixed with necessery nuts, bolts washers etc including making provisions & Supply and fixing of cabin fan and six watt LED fittings for 08/13 Ps lifts of any make.
Removal of Rusted Cast Iron trap door alongwith its frame and supply and fixing of Trap door of Size 4x7 feet and 5mm thick made out of cast iron alongwith 50x50x5mm angle iron frame. Door will be in Two pieces with two handles suitable to carry and will be painted with Two coats of black enamel paint and a 3" yellow strip over a coat of synthetic primer.
Taking down old unserviceable Chequred plate and supply and fix Aluminimum Chequred plate of 5mm thick duly fixed with nuts, bolts, washers,screws and covers with aluminimum angles section of size ( 40x40x4 mm thick) on corner of cabin in and including plateform base of 10mm thick plywood of 08/13 Ps lifts
PHOENIX ELEVATOR INDIA PRIVATE LIMITED
Monarch Enterprises
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .