Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1ST FLOOR LYNRAH COMPLEX KEATING ROAD SHILLONG EAST KHASI HILLS MEGHALAYA 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 192 POCKET 1 SECTOR 06 DWARKA NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹23.8 L
EMD Value
₹47,700
Closing Date
11 Jun 2020, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commandant ARC and MC
Assam Rifles Constr and maint coy PO Laitkor PIN 793010
Provn of Transformer 500 KVA alongwith Connected Items to ARPS Shillong
2020_ARMHA_560740_1
ENG/III-235/2020-21/02 dt 22 May 2020
Open Tender
Civil Works
Works
365 days
Laitkor, Shillong
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Commandant ARC and MC
₹47,700
Yes
9 Oct 2020
22 May 2020
12 Jun 2020
22 May 2020
11 Jun 2020
22 May 2020
22 May 2020 - 11 Jun 2020
90 days
Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC , 3 phase 50 Hz , copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180 of capactiy 500 KVA core type copper wound, oil immersed, naturally cooled, oil nature,air nature(ONAN) with external cooling tubes/fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group)with neutral brought out on secondary side (LV side ) and having tapping at ±5%HV side to be changed by means of hand operated off load tap changer gear. the maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing,copper rods, nut and washers. (b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod , complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (silca gel) (e) Explosive vent (f) Thermometer pocket on tank cover (g) One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsious wth metal guard having max perimeter reading tempreture indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body (j) Rating plate and terminal marking plate (k) Oil level gauge (l) Oil drain filter valve (m) Lifting legs (n) Oil filling holes with cap/plug with connecting plate complete (o) Air release plug (p) Four plain solid cost steel detachable rollers (q) Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral (r) First filling new and unused transformer oil IS-335/93(forth version) marked (make -HP/power oil or equivalent as approved filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335. Note: Certification of electric strength shall be submitted by the cotractor after filling the oil Make: Schnieder or equivalent as approved by GE. Note : Cost of Bricks works and foundation as per manufacturer specifications for Transformar upto 0.9 Meter above ground level with raising steps along with Cattle fancing with barbed wires (2.0 meter hight) around transformer and LT panel is included in the quoted rate.
Supply ,installed and erect of two pole structure steel tubular pole of 11 meter long duly braced with cross arms of suitable section including PCC foundation fixing grouting and couping complete all as specified and direced
Supply ,laying ,connect, testing and commissioning HT 11 KV XLPE armoured screened ,insulated ,PVC bedded , galvanised steel strip wired armoured electric power cable (heavy duty) with stranded aluminium conductor,11000 volt grade of size 3 core 120 Sq mm including necessary connection to the entire satisfaction of Engr-in-Charge. Note : Rate of under ground cable includes earth Work, sand cushioning, brick or PCC/RCC covering, light Grade GI tubing where necessary,testing etc.
Supply and fix end termination kit HT 11 KV heat shrink able suitable for HT, cable of size 3core 120 sq mm including necessary fixing /connecting to HV side of transformer and HT ,11 KV tapping point etc to the entire satisfaction of Engineer in Charge.
Supply ,connect, HT ,11 KV outdoor type gang operated air break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse assembly having 12 No's of insulator of rating up to 400 Amperes including necessary fixing on two pole structure to the entire satisfaction of Engr-in-Charge.
Supply & fixing , testing and commissioning of lightning arrester /surge arrester suitable for HT, 11KV suitable for 10 KA station class with necessary connection in line to ground at steel pole to the entire satisfaction of Engr-in-charge.
M&L for earthing complete to 2 pole structure installed with MS/GI strip of size of 32X6mm and GI earth electrode of size 600X600X6MM thick with necessary earth excavation for earth pit at required depth & width including connecting strip from earth electrode to steel tubular pole and casting of PCC earth pit chambers etc to the entire satisfaction of Engr-in-Charge
M&L for copper earthing complete to power distribution transformer 02 Nos for Neutral and 02 Nos body earth with copper strip of size 32X6MM thick with earth electrode of 600x600x5mm thick with necessary earth excavation for earth pit at required depth & width including connecting between earth electrode to body/neutral of transformer and casting of PCC earth pit chambers all as specified and directed by Engr-in-Charge.
Supply and fix on load changeover switch 415 volt, AC, 50 hz ,4 pole of 800 Ampere capacity with necessary fixing arrangement all as specified and directed by Engr-in-Charge. Make : Havells/C&S/Legrand/Siemens/L&T/ABB/Schneider
Supply & fix ACB Manual drawout type with microprocessor release of capacity 800 Amps 415 Volts,36KA, 4 pole including necessary fixing arrangement all as specified and directed and specified by Engr-in-charge. Make : Havells/C&S/Legrand/Siemens/L&T/ABB/Schneider
Supply & fix MCCB ,415 Volt, AC , 50 Hz , 4 pole of 315 amperes capacity with 36 KA fault rupturing capacity with microprocessor released based, thermal and magnetic adjustable type including necessary fixing arrangement all as specified and directed by Engr-in-Charge. Make : Havells/C&S/Legrand/Siemens/L&T/ABB/Schneider
Supply & fix MCCB ,415 Volt, AC , 50 Hz , 4 pole of 250 amperes capacity with 36 KA fault rupturing capacity with microprocessor released based, thermal and magnetic adjustable type including necessary fixing arrangement all as specified and directed by Engr-in-Charge. Make : Havells/C&S/Legrand/ Siemens/L&T /ABB/Schneider
Supply & laying , testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable 1100 volte grade with stranded aluminium conductor of size 3.5 core 400 sq mm with necessary lugging, glanding, connecting and earth work required all as specified and directed and satisfaction of by Engr-in-charge.
M&L Disconnecting of 250 KVA Transformer and LT panel carefully after taking out electrical connections from existing site and installing, testing the same in which place directed including demolition of existing fondation and construction new foundation with bricks work for transformer and LT Panel including fencing complete as per manufacturer specifications all as specified and directed by Engr-in-charge. Note : Cost of Bricks works and foundation as per manufacturer specifications for Transformar upto 0.9 Meter above ground level with raising steps along with Cattle fancing with barbed wires (2.0 meter hight) around transformer and LT panel is included in the quoted rate.
Shekhar Trading Co.
M/S B T ENGINEERS
Mahinder Electricals
Singh Company
Shree Meghalaya Construction & Supply Co.
Arbind Enterprise
Jasvit Constructions Pvt Ltd
Deepak And Brothers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .