Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹30.7 L Per unit ₹15,34,000 · 2 Set |
Tender Value
Refer Docs
EMD Value
₹69,490
Closing Date
17 Mar 2026, 2:30 pmClosed
1 location across Tamil Nadu
Design, Supply of Variable Refrigerant Flow/Variable Refrigerant Volume modular type Outdoor units.
90257934
90257934
Open - Indigenous
Goods
Tamil Nadu
₹0
₹69,490
23 Feb 2026
23 Feb 2026
Description :Design, Supply of Variable Refrigerant Flow/Variable Refrigerant Volume modular type Outdo or units complete with hermetically sealed DC inverter scroll type compressor with BLDC Motors, heat exch anger/ condenser coil, microprocessor controller, etc.. VRF/VRV manufacturer must be OEM of its compress or which is fitted in the outdoor units. All proposed outdoor unit should have minimum COP at 100% & 50% load condition respectively for cooling as per AHRI condition. Capable of operation up to 52 degree ambien t. All compressor should be DC inverter scroll type only. The outdoor aluminum fins should be with corrosiv e resistance coating apart from Hydrophobic coating. The Configuration of Outdoor unit may be higher cap acity or equal capacity as per suitability of manufacture keeping interest of site condition. INDOOR UNIT (4 NOS) and OUTDOOR UNIT (4NOS). Supply, installation, testing and commissioning of following capacity cust omized Indoor double skinned floor mounted DX refrigerant Air Handling Units (AHUs) with 25 mm thick PU F insulation, forward curved centrifugal blowers of suitable static etc. compatible with VRF outdoor unit. Th e cooling coil shall be of aluminum fins and seamless copper tubes and shall be 4-rows deep. The drive mo tor shall be of TEFC construction with suitable rating of VFD DRIVES for each indoor unit. The drain pan shal l be of stainless steel sheet inclusive of required drain pipe. The Pre-filters shall be HDPE non-woven fabric with an efficiency of 90% down to particle size of 20 microns particle size along with required accessories li ke expansion valve kit etc. Complete as required (16 TR/6400 cfm/50 mm TSP) (4 NOS ).Erection, Installatio n, Testing and Commissioning of Variable Refrigerant Flow/Variable Refrigerant Volume type Air-conditionin g Machines including supply and provision of Ancillary Components at site (4 NOS). Condition of Installation : i) SUBHOJ: Main 1 no indoor and 1 no outdoor unit with 100% Standby (1 no indoor and 1 no outdoor unit). ii) SULAYA: Main 1 no indoor and 1 no outdoor unit with 100% Standby (1 no indoor and 1 no outdoor unit),
Consignee SSE/E/AC/NGO/MAS, SR Tamil Nadu 2.00 Set Inspection Details Stage Inspection Not Required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
5538639.pdf
ATTACHMENT
5540160.pdf
ATTACHMENT
5540162.pdf
ATTACHMENT
5540166.pdf
ATTACHMENT
5644867.pdf
ATTACHMENT
5540175.pdf
ATTACHMENT
5644839.pdf
ATTACHMENT
5695999.pdf
ATTACHMENT
5540171.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .