Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 CrAccepted-AOC SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹8.6 Cr Quoted ₹8.8 Cr | L1 | Accepted-AOC Being lowest Bidder |
| 2 | L2₹9.1 Cr+₹32.8 L (3.72%)Rejected-Finance | ₹9.1 Cr+₹32.8 L (3.72%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹10.4 Cr+₹1.6 Cr (18.1%)Rejected-Finance | ₹10.4 Cr+₹1.6 Cr (18.1%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹10.6 Cr+₹1.8 Cr (20.4%)Rejected-Finance | ₹10.6 Cr+₹1.8 Cr (20.4%) | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹10.9 Cr+₹2.1 Cr (24.1%)Rejected-Finance | ₹10.9 Cr+₹2.1 Cr (24.1%) | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹8.9 Cr
EMD Value
₹7.7 L
Closing Date
7 Aug 2021, 6:00 pmClosed
Chief Engineer Bathinda Zone
Chief Engineer Bathinda Zone, Bathinda Mil Stn
Addl, altration including repair to officer married accn at Bathinda Mil Stn
2021_MES_452013_1
CA NO CE BTZ BTD TOKEN 08 of 2021-22
Open Tender
Civil Works
Lump-sum
546 days
Bathinda
As per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (S) Bathinda
₹7.7 L
Yes
17 Aug 2021
17 Jun 2021
9 Aug 2021
17 Jun 2021
7 Aug 2021
30 Jul 2021
Amount
Sch 'A' Sec - I, ( Concrete Work)
Lump sum price worked out by the Contractor for **Rs. ______________ “Concrete Work” as listed in Schedule ‘A’ Section - I Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section I
Sch 'A' Sec - II (Brick WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ Brick WORK” as listed in Schedule ‘A’ Section - II Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section II
Sch 'A' Sec III (Wood Work, Joinery Work)
Lump sum price worked out by the Contractor for **Rs. ______________ "Wood Work, Joinery Work” as listed in Schedule ‘A’ Section - III Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section III
Sch 'A' Sec - IV (Builders Harware Work)
Lump sum price worked out by the Contractor for **Rs. ______________ "Builders Harware Work” as listed in Schedule ‘A’ Section -IV Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section IV
Sch 'A' Sec - V ( GLAZING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "GLAZING Work” as listed in Schedule ‘A’ Section -V Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section V
Sch 'A' Sec - VI (STEEL WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "Steel Work” as listed in Schedule ‘A’ Section -VI Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VI
Sch 'A' Sec - VII (ROOF COVERING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "Roof Covering Work” as listed in Schedule ‘A’ Section -VII Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VII
Sch 'A' Sec - VIII CEILING AND LINING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "CEILING AND LINING Work” as listed in Schedule ‘A’ Section -VIII Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VIII
Sch 'A' Sec - IX (FLOORING & STONE MASONERY WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "FLOORING & STONE MASONERY Work” as listed in Schedule ‘A’ Section -IX Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section IX
Sch 'A' Sec - X (PLASTERING & POINTING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "PLASTERING & POINTING WORK” as listed in Schedule ‘A’ Section -X Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section X
Sch 'A' Sec - XI (WHITE/ COLOUR WASH, DISTEMPERING, PAINTING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "WHITE/ COLOUR WASH, DISTEMPERING, PAINTING WORK” as listed in Schedule ‘A’ Section -XI Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XI
Sch 'A' Sec -XII (WATER SUPPLY, PLUMBING, DRAINS, SANITARY APPLIANCES WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "WATER SUPPLY, PLUMBING, DRAINS, SANITARY APPLIANCES WORK” as listed in Schedule ‘A’ Section -XII Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XII
Sch 'A' Sec - XIII (DEMOLITION AND DISMANTLING WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ "DEMOLITION AND DISMANTLING WORK” as listed in Schedule ‘A’ Section -XIII Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XIII
Misc Items of Sch 'A' Sec -I to Sec XIII (Rate to be quoted by the tenderer in col 6)
Magnetic catcher for cup board etc to catch & support shutter, best quality complete all as specified.
Drapery rod (conduit) of dia not less than 25 mm of stainless steel having wall thickness 1.65 mm & weight not less tan1.30 Kg/RM with single bracket, fancy knobs at both ends as decided by GE fixed to walls with rawl plugs and steel screws, IN REPAIR, complete all as specified.
20 mm dia, medium weight stainless steel conduit rod of wall thickness 1.65 mm & weight not less tan1.30 Kg/RM, as curtain rod with stainless steel brackets, fancy type dooms, stop etc., IN REPAIR, complete all as specified.
PVC waste pipe with socket suitable for connection to waste fitting of 32/40 mm dia & length minimum 75cm IN REPAIR, complete all as specified
Mild steel, square grating suitable for 150 mm bore rain water socketed pipes fixed in position with cement joints IN REPAIR complete all as specified.
Tank nipple of any size IN REPAIR complete all as specified.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIR, complete all as specified.
Health faucet brass body with 1 mtr stainless steel pipe with hook IN REPAIR complete all as specified.
Kitchen plate rack made of stainless steel not less than 1mm thick with fixing accessories, overall size 900 mm x 600mm x 250 mm , IN REPAIR, complete all as specified.
Brass, chromium plated tubular towel rail 600 mm long, D type, fabricated from 20 mm bore tube IN REPAIR, complete all as specified.
Cast copper alloy, chromium plated towel ring, IN REPAIR, complete all as specified.
Stainless steel Soap dish, IN REPAIR, complete all as specified.
Mirror cabinet of size 380 X 450 mm PTMT with magnetic locking arrangements fixed with and including chromium plated brass screws and PVC rawl plugs, IN REPAIR, complete all as specified.
CP grating (with or without hole) suitable for 125 mm bore fixed in position with cement joints as in floor/nahani traps etc.IN REPAIR complete all as specified.
Fancy type corner glass shelf (300 mm) with ABS/CP brass bracket & SS/CP brass railing etc. IN REPAIR complete all as specified.
Toilet paper holder, Stainless steel fixed in position, IN REPAIR complete all as specified.
Stainless steel, fancy type, peg set of Four and fixed in position with steel screws complete as per the sample kept in the office of GE.
Mixer for mixing hot & cold water for sink, brass, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' screwed for iron pipe suitable for 15mm bore, IN REPAIR complete all as specified.
Oval access door cover to cast iron pipes of 100mm bore with rubber washer, bolts & Nuts , IN REPAIR, complete all as specified.
Oval access door cover to cast iron pipes of 75mm bore with rubber washer, bolts & Nuts , IN REPAIR, complete all as specified.
Complete removal of existing treatment of any description on old wall surfaces of any description, preparation of surfaces by mechanised sander having suction vacuum bag using smart periodical methodology complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic emulsion distemper by using airless spray/roller over and including a coat of acrylic emulsion internal primer, complete all as specified.
Preparation of new plastered wall surfaces complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic emulsion distemper by using airless spray/roller over and including a coat of acrylic emulsion internal primer, complete all as specified.
Complete removal of existing treatment of any description on old wall surfaces of any description, preparation of surfaces by mechanised sander having suction vacuum bag using smart periodical methodology complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of exterior acrylic emulsion by using airless spray/roller over and including a coat of acrylic emulsion external primer, complete all as specified.
Preparation of new plastered wall surfaces complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of exterior acrylic emulsion by using airless spray/roller over and including a coat of acrylic emulsion external primer, complete all as specified. NOTE FOR SERIAL ITEM 35 TO 38: Contractor may use manual scrapping tools for complete removal and surface preparation with prior approval of EIC in case using of mechanical equipments are not possible.
Rubber gasket 50mm wide fixed with screws or nails at bottom of door shutter on any description complete.
Magic eye for flush shutter/ panelled shutter, IN REPAIR, complete.
Water proofing treatment to sunken slab and adjoining vertical surfaces as specified below. (a) 10mm thick in cement plaster (1:3) using coarse sand mixed with water proofing compound trowel even and smooth with steel trowel on sunken surfaces. (b) Applying first coat of chemical Pidifin 2K (DR Fixit) on cleaned RCC surfaces @ 0.86 kg/ Sq. m (minimum) as recommended by manufacturers. (c) Provide a layer glass fibre mesh of size 2.25 mm x 2.25 mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturer’s recommendations. (d) Applying second coat of chemical Pidifin 2K (DR Fixit) @ 0.86 kg/ Sq. m (minimum) layer glass fibre mesh of size 2.25 mm x 2.25 mm (45 GSM) as recommended by manufacturers. NOTE : Supply only WPC will be measured and paid for separately under item of prepriced Sch of cement conc . Water testing minimum 72 hours after completion of treatment.
Taking down cement plaster including swollen/loose concrete from RCC surfaces of any description (like columns, beams, chajjas, parpets etc.) upto 50 mm depth, scrubbing down with water etc, and applying neat cement slurry @ 1.20 kg/ Sq.m of cement and applying RCC/PCC Type B-0 as directed including necessary form work if any with rough finished surface of concrete, complete all as specified. NOTE : Reinforcement & covering plastering will be measured and paid for separately under respective item of prepriced sch .
Solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet having density not less than 600 kg/Cu.m and fixing in position on back side of cup boards and like complete all as specified.
Stainless steel telescopic channel (drawer slider) of suitable size for kitchen cup boards and the like complete all as specified.
Stainless steel handles, fancy type 125 mm long for cup boards shutter complete all as specified.
First quality, staight cut/joint free, scratch free Vitrified pavers/ tiles 10 mm thick, of size 300mm x 300 mm, in floors etc. over & including 15 mm thick cement mortar (1:6) screed, set and jointed with grey cement slurry & pointed with grout of matching shade of tiles, complete, all as specified.
PCC/RCC (1:2:4) type B-0, using 12.5 mm graded stone aggregates as benching (using water proofing compound) as in broken or cracked chajjas, RCC columns, beams, stairs/ steps etc well forced on concrete surface to ensure adequate bond in two or more layers as required ( Thickness 25 mm to 40 mm) and finshied the surface with 15 mm thick cement plaster in CM 1:4, including taking out loose /cracked concrete portion and plaster etc and applying neat cement slurry before prividing concrete complete all as specified. NOTE: Rates deemed to include for any scaffolding/ ladders or any other mean to work in four storey buildings, including welding of reinforcement to be provided foe repairs of chajjas, beams, columns, stair case, fins, faciaand any type of form work etc. The reinforcement, if required, to be provided for repairs of chajjas, beams, coloumns, stairs etc shall be measured & paid under sebsequent item of Sch 'A' Sec- VI ( Part-I)
Complete removal of vegetation upto root and applying necessary chemical to prevent further growth and repair the surface with PCC 1:2:4, type B-0 or in cement mortar 1:4 as required at site complete all as specified
PVC hanrail covers for stairs of best quality fixed to iron handrails of stairs all as directed by Engineer-in-Charge
Round PVC door buffers of best quality fixed to back side of door shutters to prevent door to striking to wall all as directed by Engineer-in-Charge
Powder coated aluminum glazed window with frame of size 65.5x 38.10x 2.5 mm comprising of shutter openable, rails and shutter ( 47.62 x 44.45 x 1.95 mm – section No. 19571, shutter frame) and ( 47.62 x 44.52 x 2.17 mm- section No 20061, meeting style), including 100 mm long handle- 01 No, stainless steel 100mm hinges- 02 Nos, 100 mm long tower bolt-02 Nos, on each shutter including necessary joining cleats, glazing clips, rubber packing, anodised aluminium nap beading around both side for fixing of glass, wire mesh, screws, complete all as specified and directed by Engineer-in-Charge. ( Note:- Glass panes & wire mesh shall be measured and paid separately under Sec -V)
Subtotal
Sch 'A' Sec - XIV (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “Internal Electrification work" as listed in Schedule ‘A’ Section -XIV Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XIV.
Misc Items of Sch 'A' Sec -XIV (Rate to be quoted by the tenderer in col 6)
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit concealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Disconnecting & taking down water storage heater of any capacity from existing location and deposit the same to E/M store yard complete all as specified.
Dismantling of unserviceable existing panel board with all accessories and making good surface as per existing, complete all as specified
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed FRLS multi-stranded copper conductor single core FRLS cable as earth continuity conductor to common earth and connected to earth dolly, & including GI terminal box with base frame and cover plate of required module (suitable for modular including switch/sockets ) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
One light point controlled by two, 2 way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
NOTE FOR SERIAL ITEM 52.1-52.6: (a) Switch(es), socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) Terminal boxes shall be fixed flush to walls with cement & sand mortar (1:4) complete on the location as approved by EIC.
Modular telephone socket having two gangs including provision of GI terminal box with base frame and cover plate of suitable module complete.
Supply and fixing in replacement of LED lamp minimum 3 star rated 5W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80att and PF not less than 0.9 complete all as specified.
Supply and fixing in replacement of LED complete fitting including batten and T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap . (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)r equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply and fixing in replacement of LED mini light fitting 1 x 5 Watt, extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT : 6500K (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CRI : Morethan 80 (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement of LED light fitting 1 x 10 Watt, appx 2 feet long extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT : 6500K (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CRI : Morethan 80 (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)makes mentioned in Appendix 'B' here-in-after.
Supply and fixing in replacement of LED Surface down light 6 W Round/Square, complete with decorative ultra ceiling square/round profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection, complete fitting and all accessories with following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 160 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT 6500K (h) LED Driver of the make as of the luminaire. (i) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV (k) CRI : Morethan 80 (l) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement of LED Bulkhead fitting 1 x 9 Watt, complete with Standard profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-66. (g) CCT : 6500K (h) Pressure die cast Aluminium housing (j) LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing in replacement energy efficient LED street light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories including GI bracket made out of suitable size of light grade tube upto 1.2 mtr length, bent to shape with two sets of MS clamps made out of minimum 40 x 5 mm flat iron with suitable size of nuts, bolts and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) or equivalent in makes mentioned in Appendix 'B' here-in-after.
NOTE FOR SERIAL ITEM 54-60: (a) Contractor shall submit LM-79 and LM - 80 reports obtained from manufacturers (refer Sch A' note ). (b) Contractor shall to furnish a Replacement warranty of five years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced including taking down and refixing new luminaire free of cost in the following cases:- (i) Manfacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or Lux at 1m) below 90% of clamied values of lumens (or lux at 1m) of the LED/Luminaries. (c) All LED light/luminare must meet the provisions laid down in IS -16101, 16102 Part - I/II , 16103 Part -I, 16104,16105, 16106, 16108/2012 and 15885 Part-II Section 13. (d) Minor items required for completion of job are included in overall cost quoted by Contractor. Nothing extra shall be payable on this account. (e) Pre-dispatch inspection of fittings shall be carried out by rep of CWE/GE within overall cost quoted by Contractor
MCB, 6-32 Amp, 240 volt, single pole, breaking capacity not less than 10 kA, 'C' curve/series, complete all as specified.
RCCB, 25 Amp, 100mA, SPN, type confirming to IS 12640-1 & IEC 61009 suitable 240 volts, 50 Hz, AC supply, breaking capacity not less than 10 kA, , complete all as specified.
LT panel board , Indoor type all as specified in PSS-II clause 19B.5, installing, commissioning & testing consisting of the following components/accessories: (a) Copper bus bar of four pole, 200 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 100 Amp, thermal/magnetic based 16 KA (Ics=100% of Icu) - 01 No. (c) MCB TPN, 63 Amp, 'C' Curve,10 KA - 02 Nos. (d) MCB DP, 6 Amp, 'C' Curve,10KA - 01 No. (e) R Y B phase indicating lamps, 01 Set ( set of three) (f) Digital voltmeter suitable for 0-500 volt AC (g) Provisional arrangement for 3 phase energy meter with 2 Nos with transparent acrylic sheet with separate locking arrangement -02 Nos.
LT panel board IN REPAIR, Indoor type all as specified in PSS-II clause 19B.5, installing, commissioning & testing consisting of the following components/accessories: (a) Copper bus bar of four pole, 150 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole, 415 volt, 100 Amp, thermal/magnetic based 16 KA(Ics=100% of Icu) - 01 No. (c) MCB TPN, 63 Amp, 'C' Curve,10 KA - 04 Nos. (d) MCB DP, 10 Amp, 'C' Curve,10 KA - 01 No. (e) R Y B phase indicating lamps, 01 Set ( set of three) (f) Digital voltmeter suitable for 0-500 volt AC (g) Provisional arrangement for 3 phase energy meter with transparent acrylic sheet with separate locking arrangement -04 Nos
Ceiling fan 1200 mm sweep, AC 230 V, BLDC type, Five Star Rated, super enamelled copper winding of 'B' class insulation, single phase, minimum 26 W ( + 10 %), 350 RPM ( + 10%), 0.90 ( Min) PF, 220M3 CMM, temerature rise 40 degree maximum, compatible with conventional regulator, 3 blades, 120 V(max) low voltage rating, down rod & accesories, white colour, total harmonic, less than 10 %, 5 speed including hanging in position including connecton with flexible cord twin core twisted copper conductor of size 23/0.0076 from ceiling rose to fan, complete all as specified.
Metal body Exhaust fan 300 mm sweep, 1400 RPM fixed on directed location by providing 4 nos. 10 mm dia fasteners, and connecting complete with louvers all as specified.
Electric operated single phase Water storage heater (geyser), vertical type of capacity 25 liter, five star rating complete having vitreous enamel coated tank, single weld line tank made of ultra thick superior cold rolled steel, inlet & outlet provision, safety device and refixing the same on directed location with provision of suitable size fastener, bolts & washers and making connections with & including 15 Amp plug top having indicating light AC 230 V including writing MES No. etc. as directed complete all as specified.
Heavy duty plastic body ventilation fan 250 mm sweep, 240 volts complete with louvers and shutter and mounted in suitable opening arrangement in wall/ window and connecting up including electric connectiong with 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm from ceiling rose to fan, including fixing of exhaust fan including grouting of bolts, nuts complete all as specified. Note : Cost of modification, if required, for fixing of exhaust fan shall be deemed into the quoted rate.
Subtotal
Sch 'A' Sec - XV (EXTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - XV Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XV
Misc Items of Sch 'A' Sec -XV (Rate to be quoted by the tenderer in col 6)
Sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. (Note:- Punned thickness shall be considered for payment purpose)
Making hole using treanch less technology under road or hard standing suitable for laying and inserting pipe upto 100 mm bore, any length by mechanical drill system and making the surface good as per existing completer all as specified.
Subtotal
M/s Kataria Construction Company
M/s Jatindra Construction Company
SOM BUILDERS
RHG Constructions Private Limited
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
M/s Khanna Enterprises
ASHISH JINDAL BUILDERS PVT. LTD.
BANSI BUILDER AND CONTRACTORS PVT LTD
VIJAY JINDAL BUILDERS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .