| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.8 L
EMD Value
₹3,574
Closing Date
30 Jan 2024, 1:30 pmClosed
Executive Engineer (Elect.)
BSNL, Electrical Division, ALTTC, Ghaziabad
Shifting, ITC and repairing of Electrical assets, DG sets from Dhanora, Jhajhar and other sites in Noida BA.
2024_BSNL_790731_1
76/EEE/BSNL/ED/GZB/2023-24
Open Tender
Miscellaneous Works
Item Rate
60 days
Noida
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Account Officer Cash, B.S.N.L, Ghaziabad
₹3,574
Yes
12 Feb 2024
16 Jan 2024
31 Jan 2024
16 Jan 2024
30 Jan 2024
16 Jan 2024
Dismantling of following electrical accessories from its position etc as reqd. (a) L.T. Panel (Size-1.7mx1.1mx0.3m ) - 01 No
TP MCB DB /Main Switch/ Change Over
Split AC Units
Dismentalling of existing 15 KVA to 40 KVA E/A set i/c disconnection of power cable, Control panel, Earthing strip, exhaust pipe and fuel piping, etc complete as reqd.
Shifting of 15 KVA to 40 KVA E/A set i/c control panel, exhaust pipe, fuel tank,cables from foundation and keep a side complete as required.
Shifting & Transportation of following electrical accessories from site to in any place in Noida BA i/c loading - unloading with specialize man power & Hydraulic Crane etc. complete as required. (a) L.T. Panel ( Size-1.7m x 1.2m x 0.3m) - 01 No.
(b)TP MCB DB /Main Switch/ Change Over etc
(c )Split AC Unit 1.5 TR with all accessories
(e)20 KVA E/A set in canopy with all accessories.
(d)Out door unit of Split AC
ITC of TP MCB DB with MCB etc/Main Switch/ Change Over/MCCB, connection etc
ITC of LT Panel , connection , testing etc
S/F Digital ameter (Make- SELEC -MA 302 or similar superior make)
SITC of 4 Pole 63A 415 V On Load Change over Switch with side handle operation in sheet steel enclousers on wall, connection etc ( Make - HPL/ Havells/ L&T or similar superior make )
I.T.C of 15 KVA to 45 KVA E/A set with canopy complete with control panel, exhaust pipe, fuel tank, battery, control cables etc.on the existing foundation i/c connection of power cable, exhaust pipe & earthing strip etc. as required.
Servicing of existing 15/20/25 KVA E/A set i/c replacement of consumables such as lube oil, lube oil filter, diesel filters etc. complete as required.
Repairing of Canopy doors, providing hinges, etc
Providing N-bolt and locks in doors etc
Cleaning of diesel tank from inner side etc
Cleaning of DG set and Canopy inner side, removing all dust and dirt etc
Painting of outer side of canopy i/c removing dust, red oxide and painting with good quality of paint etc
S/F AVR Unit in DG set ,connection ,testing etc
S/F Battery charger (Transfrmer type) etc
S/F Fuel pipe in DG set etc
S/F Sheet in panel in DG set etc
S/F Hour meter in DG set , connection etc
Providing Cu lead 16sqmm for Battery, connection etc
S/F Battery terminal/ lugs for battery etc
S/F Fan Belt in DG set , etc
S/F Starting switch in DG set , connection etc
S/F Hose pipe in DG set , etc
S/F Clamp for hose pipe etc
S/F Push button , connection etc
Repairing of Self starter12v ,dismentalling & to & fro journey to workshop, i/c replacement of faulty parts, connection, testing etc.
Repairing of DC Altenator ,dismentalling & to & fro journey to workshop, i/c replacement of faulty parts, connection, testing etc
Visit charges of DG Mechanic for checking of DG set etc Note- Complaints given by SDE/AGM in emergency when DG was not started,
Repairing of Fuel pump of 15 KVA to 25 KVA DG set i/c replacement of faulty parts i/c nozzle set, elements, testing etc
I.T.C of 1.5 TR split type A/C unit i/c brazing / welding of refrigeration pipe between indoor & outdoor unit making suitable hole in the wall for crossing of refrigerant pipe a/w control cable and drain pipe with core cutting machine / hammer machine, sealing the same and making good the damage, leak test etc complete as required.
Supply & Fixing of copper refrigerant pipe lines as suction and discharge length for split A/C unit of i/c sleeve & foam insulation etc. complete as required.
Supply & fixing PVC drain pipe threaded type etc.
Supply & fixing 3 x 2.5 Sqmm round copper flexible cable (for Indoor and outdoor unit connection & mains supply)
Charging of refrigerant Gas R-22 in the existing split AC units i/c Supplying vaccmization and also pressure testing with nitrogen etc. complete with connections, testing and commissioning etc. as required.
S/F MS stand for out door unit of Split AC 1.5 tr on wall with the fastners etc as reqd
SITC of 20 Watt 1200 mm LED tubelight omplete with all accessories etc. as required. (M/s Phillips / Havells/ Bajaj/ Crompton or SS make)
SITC of Ceiling fans 1200mm sweep complete with all accessories etc. as required. (M/s Bajaj- PACER/Khatan/ Havells / Crompton or similar superior make
S/F Pendent/ Batten Holder etc
S/F LED Bulb 20 w etc
S/F Cu wire 2 core 1.5 sqmm etc
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of DG set etc including form work etc as required (2.25 mtr x1.20mtrx 0.3 mtr =0.81 cu mtr- Sect 24)
Supplying and fixing Porcelene KIT KAT 63 Ampr 415 Volt Make -Havells or similar superior make)
Supplying and fixing Neutral Link and insulators etc
Supplying and fixing of Lugs bottle type /10 sqmm/16 sqmm/25 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm on wall/ surface/ in loop as required.
Pdg.& fixing 6 SWG GI wire on surface or in recess for loop earthing alongwith the existing surface/recessed / cable etc.as required.
S/F 4 sqmm FRLS PVC insulated Cu conductor single core cable ( for neutral earthing )
Supplying and making end termination with brass compression gland and aluminium lugs for 4X16 sqmm/3.5 x 25 Sq.mm /35 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. a) 5/6 amps switch
b) 3 pin 5/6 A socket outlet
c) Regulator Piano type
Supplying and fixing 2 way sheet steel enclosure dust protected, duly powder painted with 20 amps "C" curve, SP&N MCB on surface or in recess complete with connections, testing and commissioning etc. as required.
S/F PVC Casing caping 38mm- ISI Make
S/F of MS Box 200mm x250mmX60mm deep with Phenolic laminated sheet in recess, breaking the wall and repairing etc.
M/s Chander Prakash
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .