Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.8 L+₹1.1 L (5.62%)Rejected-AOC H NO 243 VARADARAJ NAGAR VIDYARANYAPURA POST BANGALORE 560 097 | BANGALORE | BANGALORE | KARNATAKA | 560097 | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.6 L+₹2.9 L (15.4%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.0 L+₹3.2 L (17.2%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹24.6 L
EMD Value
₹49,200
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
REPAIRS TO VARIOUS TYPES OF MISC BR WORKS IN HANGARS AND OTM ACCN AND ALLIED WORK SERVICES IN TECHNICAL AREA AT AF STN YELAHANKA
2023_MES_604769_1
8182/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Yelahanka
as per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹49,200
Yes
10 Aug 2023
21 Jun 2023
21 Jul 2023
21 Jun 2023
19 Jul 2023
5 Jul 2023
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
M&L Precast cement concrete block masonry with solid blocks in Type C1, 1:3:6 (20mm graded aggregate) exc .10cm in width and setting in mortar complete set in cement mortar 1:6
Ditto all as per item Ser No. 2 above but except blocks or slabs set in cement mortar 1:6
Providing cement concrete Type C1, 1:3:6 (20mm graded aggregate) as in roof kerbs or mud stops or copings rounded or chamfered on edges
M&L rendering 10mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement.
Dismantling Asbestos cement (Corrugated, semicorrugated, etc) sheets in roof coverings
Dismantling Plain or corrugated steel or Galvalume sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
S&F pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.45mm to 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Except sheeting (any thickness) pre-painted Galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of ay colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Except sheeting (any thickness) pre-painted Galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of ay colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concelaed conduit wiring or inserting roof sheets into wall surface and further to do PCC Kerbs (PCC kerb/coping/coving wiilbe measured and paid separaely under respective items) and making good , cutting n exc 10 cm girth
Dismantling of wrought iron or mild steel work of any description not otherwise provided for
Dismantling structural steel work including doors, gates but excluding framed truss etc
S&F Rolled mild steel in section as in main and cross beamss, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe-410-W(gde-E-250) quality B
S&F Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e., within 20mm of the length indicated) in Fe-410-W(Gde-E-250) quality B
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for
M&L for Precast cement concrete Type B1, 1:2:4 (20mm graded aggregate) sas in landings, cover labs for (manholes, drain cover etc) chullah hoods, chajjas, water troughts,mangers, shelves and similar articles with plain faces set in cement mortar 1:4
M&L for Providing precast cement concrete lovres and jallies, Type Co, 1:3:6 (12.5mm graded aggregate) 50mm thick (measured solid) including all mouldings but excluding frame (Pre cast frame shall be measured sperately and paid )
M&L for Providing precast cement concrete lovres and jallies, Type Co, 1:3:6 (12.5mm graded aggregate) 25mm thick (measured solid) including all mouldings but excluding frame (Pre cast frame shall be measured sperately and paid )
M&L for TMT Bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Ditto all as per item Ser No.19 above but 6mm to 8mm dia
Taking down cement plaster or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc
Roughening surfaces of old concrete floor, ceilings by picking , sweeping clean and washing down with water to remove dust etc
Rendering 15mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth withiout using extra cement
Rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth withiout using extra cement
Brushing neat cement slurry with 3.00 Kg of cement per Sq.metre
Rendering 5mm thick cement plaster in CM 1:3 on fair faces concrete surfaces such as ceilings etc finished even and smooth withiout using extra cement
Applying 3 coats of white wash on ceilings including preparation of newly plastered or unplastered surfaces
Applying 3 coats of white wash on walls including preparation of newly plastered or unplastered new surfaces
Applying 2 coats of distempering on walls with oil emulsion white or tinted including preparation of newly plastered or unplastered surfaces
Applying 2 coats of cement base paint over a coat of white wash on newly plastered or unplastered wall surfaces.
Applying two coats of synthetic enamel paint (ordinary tint) over steel and iron surfaces of any description, over 10cm in width or girth , not otherwise described including preparation of new or previously un treated steel surfaces.
Applying one coat of white wash on old surfaces of walls including preparation of old wall surfaces.
Applying one coat of distempering on old surfaces of walls with oil emulsion white or tinted including preparation of old walls surfaces.
Applying one coat of Cement base Paint on old wall surfaces including preparation of old wall surfaces
Applying one coat of Synthetic enamel paint onver steel and Iron surfaces of any description, over 10 cm in width or girth, not otherwise described including preparation of old painted surfaces
Applying one coat of Synthetic enamel paint over wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation old painted wooden surfaces.
Applying one coat of Synthetic enamel paint over Brick, Stone, concrete, Asbestos, Cement plaster surfaces of any description over 10 cm girth or width , not otherwise desdcribed including preparation of old painted surfaces.
Applying one coat of Synthetic enamel paint over old steel and Iron surfacs of any description, n exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint including preparation old painted steel and Iron surfaces.
M&L for preparation of old decorated surfaces of walls (Border & vertical projections such as cols, chajja, facia beams and the like), floor, interlocking tiles & chequered tile and road side kerb etc by washing rubbing down and stopping of painted surfaces and applying one coat of exterior acrylic emulsion anti fungal paint any colour or shade complete all as specified and as directed .
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
Demolition of cement concrete (Un reinforced) of any description and in any position not otherwise specifically provided for
Excavating over areas, n exc 1.5m deep and getting out in Hard/dense soil
Excavating in trenches, nexc 1.5m wide and n exc 1.5m in depth; for foundation, etc . Or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 Sqcm on plan and n exc 1.5m in depth and getting out in Hard/dense soil
M&L for Hard core of gauge n exc 63mm in broken stone or boulders , deposited, spread and levelled in layers n exc 15 cm thick , watered and rammed to a true surface
M&L for PCC1:4:8 type D2 (40mm graded aggregate) as in foundations, filling and mass concrete
M&L for Cement Concrete Type C2, 1:3:6 (40mm graded aggregate) as in surface channels and drains
M&L for 100mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub-floors, sub bases, floors and pavings etc
M&L for 100mm thick Cement concrete type B-2,, 1:2:4 (40mm graded aggregate) as in sub-floors, sub bases, floors and pavings etc
M&L for Sand filling under floors or in foundations including watering and consolidation, spreading and levelling in layers n exc 25cm thick well ramming including watering as required.
M&L for Machine pressed precast concrete Interlocking paver block rubber moulded with laquor finished of any shape and size confirming to IS-15658-2006 of 60mm of thickness, M-35 Grade with grey cement andn no pigment
Ditto all asper item No.50 above but except tiles
Removing excavated material exc 1.50m but n.exc 5 KM and depositing where directed in soils.
Forming construction Joint 30mm deep x 10mm wide filled with sealing compound Grad "B"
Forming , 12mm thickExpansion joinys filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade "B". Thickness of Slab 100mm
M&L for 25mm thick Cement Concrete type B-1, 1:2:4 (20mm graded aggregate) finished even and fair to receive top layer
M&l for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes) in CM 1:4
M&L for Vitrified Ceramic Tiles 9-10mm thick (square rectangular) polished , Light shade area of each tiles not exceeding 0.36 sqcm in floors etc set and jointed in neat cement slurry and pointed in in white or coloured cement to match
Rendering 15mm thick Cement Plaster in CM 1:4 on fair faces of brick work or concrete surfaces finished even and fair to receive top layer such as Dado, skirting etc
M&L for Non-skid ceramic tiles 7 to 8mm thick, joint free coloured tiles (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Non-skid ceramic tiles 7 to 8mm thick, joint freecoloured tiles (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Non-skid ceramic tiles 7 to 8mm thick, joint free coloured tiles (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Glazed ceramic joint free coloured tiles in vertical surface 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Glazed ceramic coloured joint free tiles in vertical surfaces 350 x 250x 7mm / 450 x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for Vitrified Ceramic Tiles 9-10mm thick (square rectangular) polished , Light shade as in skirting to match with Vitrified Ceramic tile flooring etc set and jointed in neat cement slurry and pointed in in white or coloured cement to match
Dismantling boarding any description, fixed in any position with nails
S&F 2nd class soft wood 15mm thick Boarding fixed with nails in any situtation planned one side with butt joints
Applying two coats of synthetic enamel paint (ordinary tint) over wooden surfaces of any description, not otherwise described over 10 cm width or girth
S&F in repairs Mortise lock, Brass, vertical type, size 100 mm, 4 lever
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads/EPDM gaskets all as specified and as directed.
Hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones
S&F plain sheet glass 4mm thick , ordinary quality and glazing with oil putty or using EPDM Gaskets in squares n.exc 0.50 Sqm in each pane.
S&F Solar control film 25 micron reflective type sticked to glass panes as per manufacturers instructions.
S&F in repair Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F in repairs Door closer hydraulically regulated, with aluminium extruded section body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
M&L for replacement of wooden glazing beading of 2nd class hard wood straight (any size) finished wrought for glazing or gauged joinery for fixing wire gauge/ securing glass pane complete all as specified and directed by Engr-in-Charge.
Running welding in repairs of thickness of metal to be welded n exc 6mm.
Welding in repairs n exc 2.5cm in length of thickness of metal to be welded n exc 6mm
Welding in repairs exc 2.5cm but n exc 5 cm in length of thickness of Metal te be welded n exc 6mm
Welding in repairs exc 2.5 cm but n.exc 5 cm in length of thickness of Metal to be welded exc 6mm but n.exc 9mm
S&F Welded steel wire fabric weight per sqm not exc 4.00 Kg supplied and fixed complete to wood or steel members
S&Fin repairs Mild steel ,plain black sheet of 0.63mm thickness in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as required.
S&F in repairs Mild steel ,plain black sheet of 0.63mm thickness as in hearths; covering to door shutters; covering to door chowkats (frame); chullah hoods; water tanks, water troughs, ducts, urinal troughs and funnels, etc., cut to size edges beaded if directed, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel members, etc with plain 40mm lap joints or welded/riveted seams including bending , turning up mitred angles stopped ends, outlets, etc as required.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store. Bore of pipe 20mm
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store. Bore of pipe 25mm
Refixing of old steel tubing and connections in new or old position (Walls, ceiling, floors etc). Bore of pipe 20mm
Refixing of old steel tubing and connections in new or old position (Walls, ceiling, floors etc). Bore of pipe 25mm
Supplying and laying of CPVC pipes 20mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors all as specified and as directed.
Supplying and laying of CPVC pipes 25mm Outer dia, SDR 11 & Plain CPVC SDR 11 fittings on wall, ceiling and in floors all as specified and as directed.
S&F GI tubing 20 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete.
S&F GI tubing 25mm dia medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/stopped ends etc.
Extra for forming fair finished drain or channel 50cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/stopped ends etc.
S&F in repairs of Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed. Bore of pipe 25mm
S&F in repairs of Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed. Bore of pipe 20mm
Taking down soil waste/vent pipes (any size or length) pattern), including all fittings,
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors including flat iron clamp for proper fixing complete all as specified & directed by Engr-in-charge.
S&F in repairs PVC (SWR) bends 110mm dia complete all as specified & directed by Engr-in-Charge.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors including flat iron clamp for proper fixing complete all as specified & directed by Engr-in-charge.
S&F in repair PVC (SWR) bends 75mm dia complete all as specified & directed by Engr-in-Charge.
Note:- (a) Works to be carried out in OTM accn (high rise bldgs) such as hangars, towers, RCC over head reservoirs etc at heights up to 20 mtrs (b) Contractor has to follow all saffety norms issued by GOI for working labourers and also arrangew all necessary scaffoldings, cranes/hoopers,suspended movable platforms, rope ladders as the case may be and the rate shall deemed to be included in the quoted rates. (c) Any damage to the existing bird proofing nets, wire mesh and ceiling inside hangar and any other buildings during the execution of work shall be repaired by the contractor as directed by Engr in Charge. No extra claim on this accoount will be entertained by the department.
chowdeshwariconstructionco
SRI GANESH ENTERPRISES
JyothsnaNursery
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .