Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹21.7 L+₹8,000 (0.37%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹21.8 L+₹17,930 (0.83%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹24.2 L+₹2.5 L (11.8%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹24.4 L+₹2.8 L (12.7%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹49.1 L
EMD Value
₹98,200
Closing Date
9 Oct 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR AND REPLACEMENT OF VARIOUS PARTS OF PACKAGE AC PLANT AT BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
2023_MES_619290_1
GE/DE-64/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹98,200
Yes
17 Feb 2024
18 Sept 2023
11 Oct 2023
18 Sept 2023
9 Oct 2023
2 Oct 2023
Amount
Taking out the filter from Package type AC plant up to 8.5 TR to 22 TR, Cleanning condensing coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil and refixing the air filter after cleaning, including testing complete all as specified and directed.
M&L for repairing/ Rewinding indoor package unit Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & discription to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-
3 HP/ 2.2 KW indoor blower fan motor, Make-Kirloskar, Cromton Greaves,Hindustan Electric Motor
2.2 HP/ 1.65 KW indoor Blower fan motor, Make- Make-Kirloskar, Cromton Greaves,Hindustan Electric Motor
4.0 HP/ 3.0 KW indoor Blower fan motor, Make- Make-Kirloskar, Cromton Greaves,Hindustan Electric Motor
Taking down high pressure interconnecting refrigerant pipe of following sizes
12.7 mm copper pipe
15.9 mm copper pipe
22.2 mm copper pipe
28.6 mm copper pipe
Repair/Replacement of high pressure interconnecting refrigerant pipe of following sizes 19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications.and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed: -Make- Mandev/ Rajco/ Maxflow
12.7 mm with 13 mm copper pipe
15.9 mm with 13 mm copper pipe
22.2 mm with 19 mm copper pipe
28.6 mm with 19mm copper pipe
Supply only, in replacement Scrool type Compressor Capacity 5.5 TR, Model No HLDO72T4LL6, and making electric connections and taking down old unserviceable Compressor, complete all as directed.
Supply only, in replacement Scrool type Compressor Capacity 8.7 TR, Model No HLDO72T4LL6, and making electric connections and taking down old unserviceable Compressor, complete all as directed.
Supply only, in replacement Scrool type Compressor Capacity 11.00 TR, Model No ZRI44KFF-TFD-522, and making electric connections and taking down old unserviceable Compressor, complete all as directed.
Supply only, in Replacement of Condensor coil for 5.5 TR and taking down old unserviceable condensor coil, complete all as directed.
Supply only, in Replacement of Condensor coil for 8.7 TR and taking down old unserviceable condensor coil, complete all as directed.
Supply only, in Replacement of Condensor coil for 11.0 TR and taking down old unserviceable condensor coil, complete all as directed.
S&F in replacement Cooling Coil Suitablr for 8.7 TR Package Unit Model No:- DPA1052R2A and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Cooling Coil Suitablr for 11.00 TR Package Unit Model No:- DPA1322R2A/ DPA1321R3 and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Cooling Coil Suitablr for 16.5 TR Package Unit Model No:- DPA1983RA/ DPA1982R3 and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Cooling Coil Suitablr for 22.0 TR Package Unit Model No:- DPA2642R2A/ DPA2642R3-IA and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in Replacement of Filter drier 3/8 mm
S&F in Replacement of Filter drier 5/8 mm
S&F in Replacement of Filter drier 7/8 mm
S&F in Replacement of Filter drier 1/2 mm
S&F in replacement Expansion valve Suitable for 5.5 TR and taking down old unserviceable Expansion valve, complete all as directed.
S&F in replacement Expansion valve Suitable for 8.7 TR and taking down old unserviceable Expansion valve, complete all as directed.
S&F in replacement Expansion valve Suitable for 11.00 TR and taking down old unserviceable Expansion valve, complete all as directed.
S&F in replacement Controler (PCB) with remote suitable for for 8.7 TR Package Unit Model No:- DPA1052R2A and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Controler (PCB) with remote suitable for for 11.00 TR Package Unit Model No:- DPA1322R2A/ DPA1321R3 and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Controler (PCB) with remote suitable for for 16.5 TR Package Unit Model No:- DPA1983RA/ DPA1982R3 and making electric connections and taking down old unserviceable Compressor, complete all as directed..
S&F in replacement Controler (PCB) with remote suitable for for 22.0 TR Package Unit Model No:- DPA2642R2A/ DPA2642R3-IA and making electric connections and taking down old unserviceable Compressor, complete all as directed.
S&F in replacement Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA1322R2) Suitable for 22 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 1250 mm x 658 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA1983R2) Suitable for 11 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 828 mm x 577 mm of grade G3 complete all as specified and directed.
S&F in repair Air filter for Air cooled type package type (Blue star pakage Unit Model : DPA2642R2) Suitable for 16.5 TR air Conditioners of material Non woven polyster media enclosed by HPDE mesh filter size should be (H x w) 933mm x 457mm of grade G3 complete all as specified and directed.
Supply & charge the refrigerent R - 407 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
Supply & charge the refrigerent R - 410 Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)
S&F in repair Magnetic contactor 415 V, 32 Amp type NC1-3201 , 1NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair Magnetic contactor 415 V, 50 Amp type NC1-5011 , 1NC auxiliary contact block, coil voltage 230 V with including connecting complete as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
S&F in repair Magnetic contactor 415 V, 18 Amp type NC1-1801 , 1NC auxiliary contact block, coil voltage 230 V with including connecting complete all as specified and directed. Make- SIEMENS/ L&T/ BHARATIA CUTTLER HAMMER
Checking the interlocking control and attending the compaint of control panel wiring of AC plant and making it fully serviceable with and including all size of wires, thimble, PVC, bakelight, connection plate Nut bolt, MCB, Indicator Lamp, MO NC block and other items. Note 01:- After intimation of breakdown by JE/ AGE E/M through telephone or verbally, the contractor should arrange the machanic to attend the complaint in side BHDC premisis within 2 hours and make them functional, if any item required the same shall be measured from particular item from schedule for complete work. Note 02: If complaint intimation is done after 1600 hrs then complaint to be attented by contractor at 800 hrs next day. Note 03 : If contractor failer to attend complaint with in time frame, the recovery of Rs400/ Hrs will be implemented.
S&F in replacement, of MCCB 100 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCCB 200 Amp, 3 pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
S&F in replacement, of MCB 63 Amp, - pole thermal magnetic relese based with breaking capacity 36 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barries, taking down unserviceable one complete all as directed. Make- Siemens/ L&T/ Schneider Elect/ C&S
Supply only in replacement of Fan belt Size A 28 and taking down unserviceable fan belt complete all as directed.
S&F in replacement of pully with blower shaft and bearing suitable for package unit 8.7 TR to 22 TR, including taking down unserviceable parts and refixing same complete all as directed.
Supply only in replacement of control wiring with single Core 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded. complete all as specified and directed
Supply only in replacement of control wiring with single core 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded,complete all as specified and directed
M&L for control wiring with single core 6 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, complete all as specified and directeted.
M&L for control wiring with single core 10 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded complete all as specified and directed.
M&L for control wiring with 4 core 2.5sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, complete all as specified and directed (Note : Two run of wire with PVC conduit will be considered as one Length.)
RUCHIKA ENGG.WORKS
Vishal Traders
SANJEEV ENTERPRISES
DP Traders
M P TYAGI ENGINEERS AND CONTRACTORS
Akarsha Enterprises
HVAC Engineering Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .