Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹43.1 L+₹9.7 L (29.2%)Rejected-AOC | L2 | Rejected-AOC Awarded as second lowest bidder (L2) | |
| 3 | L3₹44.5 L+₹11.2 L (33.6%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-AOC Awarded as third lowest bidder (L3) | |
| 4 | L4₹45.3 L+₹12.0 L (35.9%)Rejected-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-AOC Awarded as forth lowest bidder (L4) | |
| 5 | L5₹46.8 L+₹13.4 L (40.2%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L5 | Rejected-AOC Awarded as fifth lowest bidder (L5) |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR MAINTENANCE TO EXTERNAL ELECTRIC SUPPLY STREET LIGHT AND OTHER CONNECTED WORK IN ARDE UNDER GE RD PASHAN PUNE
2021_MES_461760_1
GERD/PSN/TOKEN/20 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
GERD PASHAN PUNE
₹80,000
Yes
31 Aug 2021
22 Jul 2021
18 Aug 2021
22 Jul 2021
14 Aug 2021
6 Aug 2021
22 Jul 2021 - 5 Aug 2021
60 days
Amount
On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified and directed. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various cap installed in various locations complete all as specified and directed . Make of Transformer oil: Savitha or equivalant in make as specified in appendix 'B' as approved by GE. Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply & Fixed in repairs of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,for the following size ,22 KV complete all as specified and directed by Engineer-in-charge. (a) HT Straight through joint for 95 sq mm cable 3 core
(b) HT Straight through joint for 185 sq mm cable 3 core
Material and labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, for the following size, 22 KV all as specified and directed by Engr-in-charge. (a) HT End termination joint for 95 sq mm cable 3 core
(b) HT End termination joint for 185 sq mm cable 3 core
Repair to gang operated air brake switch device upto 400 Amps,22 KV capacity including greasing/oiling of all moving contacts,replacement of nut bolts,washers of suitable sizes, unserviceable spares and jumper connections in all phases for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections to be replaced will be measured and paid separately as "Supply only"
Supply only the following items against repairing of GOD any type complete all as specified and directed :- a) Male contact/moving contact blade of gang operated AB switch devices suitable for 22 KV.
b) Female contact /fix contact jaw for gang operated AB switch devices.
c) Tinned copper flexible jumper 200/200 Amps.
d) Post top Polymer insulators of gang operated AB switch devices.
e) Middle post Polymer insulators of gang operated AB switch devices.
f) Bottom post Polymer insulators of gang operated AB switch devices.
g) MS jumper carrier.
h) Back connector plate.
(j) GI pipe, light grade 25 mm dia made to shape for gang operating from ground.
Repairs to drop out fuse complete of upto 400 Amps, 22 KV capacity including replacement of worn out nut bolts,washers of suitable size, unserviceabele spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections to be replaced will be measured and paid seprately as "Supply only"
Supply only the following item (to be incorporated under Item No 18 above) complete all as specified and directed :- a) Fix top contact/L contact for drop out fuse.
b) Fix lower contact for drop out fuse.
c) Post insulators of drop out fuse.
Material and labour in repairs for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs or one end with AI lugs and other end plain for binding with conductor encased with polythylene sleeve, RYB colours of suitable dia complete all as specified and directed for :- a) Not exceeding 0.75 m length.
b) Exceeding 0.75 m length but not exceeding 1.5 m length.
c) Exceeding 1.5 m length but not exceeding 2.5 m length.
d) Exceeding 2.5 m length but not exceeding 3.0 m length.
Supply, installation, testing and commissioning in replacement of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete with GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformer, all ferrous parts hot dipped galvanised and non ferrous parts heavelly tinned to withstand weather complete all as specified and directed.
Supply & Fixed in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning all as specified and directed by Engr-in-charge.
Supply & Fixed in repair Polymer Pin type insulator of 22 KV including necessary hardware and taking down existing unserviceable insulator complete all as specified and directed.
Supply & Fixed in repair Polymer disc type insulator, ball and socket type, white brown or green 2 in series for 22KV including necessary hardware and taking down existing unserviceable insulator complete all as specified and directed.
Supply & Fixed in repair defective lightining distribution surge arrestor, non linear type MCOV, 18 KV, 5 KA with all fittings bolts nuts and washers etc complete all as specified and directed.
Material and labour for preperation of old painted steel surface of following HT steel pole structure above GL/coping including cross arms,channels,Flat iron,Clamps in HT OH line by scraping with wire brush and applying one coat of aluminium paint including pole numbering complete all as specified and directed for the following types:- a) HT 4 Pole structure 11 m long.
b) HT 2 Pole structure 11 m long.
c) HT pole 11 m long.
Disconnecting the Pole mounted/platform mounted outdoor type transformer situated at various locations inside ARDE sub station 22/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop and testing complete all as specified and directed for the following capacities of transformer :- Notes (i) Copper winding wire/strip will be measured and paid separately as 'supply only'. (ii) Insulating oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation is deemed to include in quoted rates. a) 50 to 100 KVA.
b) 150 to 200 KVA.
c) 250 to 315 KVA.
d) 400 to 500 KVA.
Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers under item No. 1 primary and secondry coils including necessary class of insulation complete all as specified and directed. Make : ISI marked as approved by GE/Engr-in-charge.
Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers under item No. 1 primary and secondry coils including necessary class of insulation as specified and directed. Make : ISI marked as approved by GE/Engr-in-charge.
Material and labour for carrying out Lab test for acidity of Transformer oil for various Transformers at DRDO Estaste and submitting test report on the format complete all as specified and directed by Engr-in-charge.
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 750 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load and testing complete all as specified and directed. Note : Defective parts to be replaced will be measured and paid separately as "Supply only" under respective items here in after.
Supply only LT bushings with brass studs of existing specification complete all as specified and directed.
Supply only top cover gasket set complete all as specified and directed.
Supply only radiator flanged gasket 6 mm thick complete all as specified and directed.
Supply only oil level indicator gasket set complete all as specified and directed.
Supply only HT bushing with stud 22 KV of existing specification complete all as specified and directed.
Supply only explosion vent diaphragm of suitable size to match with the existing complete all as specified and directed.
Material and labour for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writing MES/SM No. complete all as specified and directed by Engr-in-charge for : (a) 50 to 100 KVA capacity of transformer.
(b) 160 to 250 KVA capacity of transformer.
(c) 300 to 500 KVA capacity of transformer.
Material and labour for lifting of serviceable transformer of capacity 100 KVA to 500 KVA, 22/ 0.433 KV rated voltage, from one place to other by crane and transporting to other place within 02 Km radius including placing on plinth/pole mounting and connecting up all HT/LT connections, testing and energising the transformer complete all as specified and directed by Engr-in-charge.
Material and labour for disconnecting, opening, draw out RMU/ VCB trolley complete from its position after isolating safely from contacts of breakers for inspection, checking and re installing testing commissioning of same after carryout following repair work and replacement of unserviceable spares by OEM complete all as directed and specified comprising of followings :- (i) Checking of Draw out mechanism/arrangement of VCB (ii)Inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts . (iii) Checking of alignment with spout and setting of contact gaps. (iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease. (v) Checking/setting of master control relay, earth fault realy and overload realy. (vi) Replacement of burnt out spring charge motor, (vii) Replacement of Closing Coil 30V DC, (viii) Replacement of tripping Coil 30V DC. (ix) Replacement of top spout with Busbar. (x) Replacement of Bottom spout with Busbar. (xi) Replacement of power pack. (xii) Also checking ON/OFF/TRIP indication and make it serviceable by necessary checking/repair/replacement of control wiring. Replacement of Push button for open and Close, micro switches, indication lamps. (xiii) Decarburizing and reinsulation of complete busbar track system complete in all respect. (xiv) Misc works deemed essential to make VCB in perfectly working order. Note : Major spare parts are to be paid separetly under respective items here in after, however cost of minor spares required for smooth functioning shall be deemed to be included in item rate.
Supply only following spare part suitable for 30 VDC/ 110VAC complete all as specified and directed :- (a) Spring charge motor single phase 110/220 volts.
(b) Closing Coil 30V DC.
(c) Tripping Coil 30V DC.
(d) Top spout with Busbar 22 KV.
(e) Bottom spout with Busbar 22KV.
(f) Finger contract.
(g) Push button for open and Close.
(h) Micro switches.
(j) Indication lamps.
Supply and fixing in repairs of Current Transformer - 01 No dual ratio of rating 100/50/5A, 22 KV pressure epoxy cast resin complete duly intalled, commissioned, connected and tested at site complete all as specified and directed. Make : PRAGATI, PRAYAG, KAPPA, CROMPTON, AE, L&T, Vishal or as per existing make.
Supply and fixing in repairs Potential Transformer ( PT) - 01 No ratio 22000/√3 volts/110/√3 volts, VA class for PT 50/0.2, Insulation level 24/50/125 KVP specially designed all as per MSEDCL recommendations and approval and testing complete all as specified and directed. Make : PRAGATI, PRAYAG, KAPPA, CROMPTON, AE, L&T, Vishal or as per existing make. Notes for item Nos 63 & 64 :- (a) The contractor's quoted rates for shall be deemed to include for the following provisions. Nothing extra shall be paid to contractor on this account. (i) The work shall be carried out under combined supervision of MES and MSEDCL and Accepting Officer, (ii) It is the responsibility of the contractor to get approval of repair work from MSEDCL, (iii) The contractor should co-ordinate the work with MSEDCL authorities for testing of metering unit (KIOSK) for repair work, (iv) CT ratio of metering unit should be as per the requirement of MSEDCL at the time of commissioning of the instllation, (vi) Testing metering unit and TOD meter shall be as directed by MSEDCL Officer that is responsibility of contractor, (v) Rate quoted is also inclusive of Transportation from manufacturers workshop to work site, Testing charges of MSEDCL.
Material and labour for checking of resistance of earthing by disconnecting all electrical connection safely complete all as specifed and directed. Note: Contractor will carry out necessary equipment and skilled person at site & no extra payment will paid to contractor on this account.
Material and labour for Fault Finding of defective, short circuit unserviceable under Ground 1.1KV LT cable with mobile fault finding instrument and accessories, locating fault or place of short circuit for jointing and defect rectification complete all as specified and directed.
Material and labour for Fault Finding of defective, short circuit unserviceable under Ground 22 KV HT cable with mobile fault finding instrument and accessories, locating fault or place of short cicuit for jointing and defect rectification complete all as specified and directed.
Material and labour for primary and secondry injection testing of existing CT's set of three any type any capacity installed in VCB's lacated at different sites and providing authentic test results for further necessary action complete all as specified and directed.
Dismantling cross arms / MS channel from HT pole including clamps, nuts, bolts & washers complete all as specified and directed.
Supply, installation, commissioning and testing in repairs numerical digital over current and earth fault relay with High set & RS -485 port including suitable rating of CT, IDMT & definite time characteristics, last 30 trip data recording with date and time and password protection operated on 30 Volts DC/240 volts AC of any make installed in VCB panel for protection against short circuit and earth fault, testing, commissioning and submitting test report on proper format including taking out old unserveciable complete all as specified and as directed. Make : L&T Cat No MC61 CNX4000 or Equivelent features in Crompton Grieves, Siemens, Schnieder.
Supply and fixing in repairs HT Right angle boot 22 KV rating on HT side of existing transformerrmers for jointing HT cable complete all as specified and as directed.
Supply and fix in repairs power connector accessories made out of aluminium alloy according to IS:617 : 1975 and conforms to IS: 5561 : 1970 galvanic corrosion free heavy duty working pressure 22 KV , enough to carry electrical load and to withstand the mechanical forces imposed during installation as well as service condition and the arrangement of bolts, bolt & washers such that the pressure is uniformly distributed over the whole contact surfaced area complete all as specified and as directed for following type of clamps:- a) PG clamps suitable to connect conductor to conductor. Make : Jaipuria Brothers or equivalant in make as specified in appendix 'B' as approved by GE.
b) Pad connctor suitable to pin insulators and aluminium bus bar.
c) T connector suitable to connect aluminium bus bar to conductor.
d) Expansion type connector for multiple connection.
Material and labour in repairs for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with the top edges of plate not less than 1.5 m below normal ground level connected to GI earth strip 32mmx6mm by means of GI nuts, bolts check nuts and washers earth lead protected by 40mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 including testing on completion complete all as specified and directed. Notes : The unit rate also including necessary charcoal & salt, for excavation & earth work in any type of strata, plain cement concrete 1:3:6 mix Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways, GI funnel with wire mesh, GI watering pipe 20mm dia light grade with wire mesh & funnel, protection pipe 40mm dia GI pipe light grade for earth lead upto 7.50m long complete.
Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4.0 mm dia by means of GI nuts, bolts check nuts and washers earth lead protected by 15 mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion complete all as specified and directed. Notes : The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40 mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8 mm dia TMT bars @150 mm C/C both ways ,GI funnel with GI watering pipe 20 mm dia med grade ,wire mesh, protection pipe 40 mm dia GI pipe light grade for earth lead upto 7.50 m long complete.
Material and labour Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Material and labour in repairs for Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32x6 mm size galvanised strip complete all as specified and directed.
Material and labour for 22 KV HT cable Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the UG XLPE cabling system for rectifying defects and rest report to be submitted complete all as specified and directed.
Material and labour for 22 KV HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the over head lines system for rectifying defects and rest report to be submitted complete all as specified and directed.
Material and labour for 22 KV HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the HT structure 2/4/6 poles and its controlling system for rectifying defects and rest report to be submitted complete all as specified and directed.
Material and labour in repairs for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 120 sqmm,22 KV complete all as specified and directed by Engineer-in-charge. Make : M seal/ Denson
Material and labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for PCC 1:3:6 type CI using 20mm graded crushed stone aggregate as in coping weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size fixing to existing pole and inclusive of one primer coat, one under coat and one finishing coat of paint as indicated complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down guarding wire and removing to store for safe custody or issue under Sch of credit complete all as specified & as directed.
Dismantling and taking down HT OH line conductor and removing to store for safe custody or issue under schedule of credit complete all as specified & as directed.
Taking out steel tubular sewaged poles HT/LT 11/9 mtr long and removing to store for safe custody or issue under schedule of credit complete all as specified & as directed.
Supply and fix in repairs Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade including taking out existing unserviceable insulator all as specified and as directed.
Material and labour for Cradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4 mm in repair or replacement complete all as specified and directed.
Supply and fix HT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 11 metre long complete all as specified and directed. Note : Excavation and earth work and PCC will paid and measured and paid for separately.
Supply and fix LT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 9 metre long. Note : Excavation and earth work and PCC will paid and measured and paid for separately.
Material and labour for aluminium conductor steel reinfoced for over head line, fix on pole bringing the sag with in limit, fixing to the insulator by means of necessary binding with 14 SWG aluminium wire complete all as specfied and directed.
Cutting the tree branches which touches the LT/HT OH lines and 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 mtrs between poles and deposting the tree branches/leaves at 30 m distance away from site complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
Supply and fix in replacement, connect, test and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) complete all as specified and directed by the Engr-in-Charge for the following :- Notes : (i) Excavation & earth work, sand cushioning, brick protection will be measured and paid separately (ii) Cost of jointing materials e.g. lugs, thimbles, nuts bolts and washers shall include in quoted rate. (a) 185 Sqmm 3.5 core.
(b) 95 Sqmm 3.5 core.
Laying only LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes (where ever cable laid in ceilings/walls without cable duct) all as directed by the Engr-in-Charge for the. (a) 70 Sqmm 3.5 core Note: (i) XLPE LT UG cable will be issued under schedule 'B' Store. (ii) Excavation & earth work, sand cushioning, brick protection will be measured and paid separately under relavant item here in before . (iii) Cost of jointing material e.g. lugs, thimbles, nut bolt and washers shall include in quoted rates.
(b) 50 Sqmm 3.5 core.
(c) 35 Sqmm 3.5 core.
(d) 16 Sq mm 4 core.
(e) 10 Sq mm 2 core.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of earth soil complete all as specified and as directed:- (a) Soft/loose soil.
(b) Hard/dense soil.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour dry crushed stone dust/ river sand filling in trenches to required width at bottom and top of cable cushioning including spreading leveling and consolidation complete all as specified and directed. Note : Punned thickness shall only be measured and paid.
Material and labour bricks sub class 'B' laid flat dry across the cable for cable protection complete all as specified and directed by Engineer-in-Charge.
M/L GI tube, , light grade with all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection all as specified and directed for the following size of pipe :- NOTE :- Excavation and earth work where required shall be measured separately. MS Clamps for fixing on wall / pole , etc are included in the unit rate. (a) 80 mm dia bore.
(b) 40 mm dia bore.
Material and labour for scraping of old paint from steel pole structure LT pole / street light tubular pole 8.5/9.0 m long above GL/coping including cross arms,channels,Flat iron,Clamps in LT OH line with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering complete all as specified and directed by Engr-in-charge.
Material and labour for Checking/megering of UG cable fault of any size/core and taking out the damaged portion of cable from trenches and removing the fault portion of cable and checking, jointing the same with proper cable end jointing kit and testing for smooth functioning of complete cable and re-laying the same after testing complete all as specified and directed. Notes : (i) Excavation & earth work, relaying of bricks and relaying soft soil for cushioning deemed to including the job. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
Material and labour in repairs for straight through joint for UG cable including joint kit for making joint suitable complete all as specified and directed for the following size :- (a) 10 sq mm to 16 Sq mm, 2 core.
(b) 16 sq mm to 25 Sq mm, 4 core.
(c) 35 to 95 Sq mm, 3.5 core.
(d) 120 to 150 Sq mm, 3.5 core
Material and labour for disconnecting from existing main taking out from LT panal board for servicing & overhauling LT panel/ LT ACB panel of any make 400 to 1000 Amp, 50Hz 415V AC including taking out existing mechanism complete with servicing of operating machnism, testing of triping mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original postion with all connections and testing complete all as specified and directed. Note : Spare parts to be replaced shall be measured and paid for separetly under respective items here in after.
Supply only Following spare part suitable for LT ACB suitable 400A-1000 A Capacity complete all as specified and directed :- (a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories.
(b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB.
(c) Under voltage tripping divice (UVT) 415 volts.
(d) Single phae CTS at rating 800/5A.
Material and labour for welding to LT panel or doors including scaping to old paint and applying two coats of synthetic enamal paint over a coat of primer.
Supply and fix in repairs MCCB 4pole, 400 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type Make : Legrand / L&T / C&S /ABB
Supply and fix in repairs MCCB 4pole, 250 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type
Supply and fix in repairs MCCB 4pole, 200 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type Make : Legrand / L&T / C&S /ABB
Supply and fix in repairs MCCB 4pole, 100 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type. Make : Legrand / L&T / C&S /ABB
Material and labour for removing all HT/LT electrical connection, magger value of cable including safely removing of loop of under ground cable burnt/ faulty & by provinding new lugs to cable end complete all as specified and directed. Note :- Rates for necessay equipment and earth work are included in quoted rates by contractor.
Supply and fix in replacement of LED street light /road way luminaries 45 watts pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.Make Havells Cat No. ENDURAPEARLPLUSSL45WLED757SASYTOPC OR Equivalent in make as specified in appendix 'B' as approved by GE.
Supply and fix in replacement of LED street light /road way luminaries 60 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed. Make Havells Cat No. ENDURAPEARLPLUSSL60WLED757SASYTOPC OR Equivalent in make as specified in appendix 'B' as approved by GE.
Supply and fix in repairs decorative LED land scape light of 8 watt garden/path light fitting cone series act as imposing street furniture, the elegent yet minimalstic design acts a silent observer and giving light, diffuser at the upper portionacts a beacon of path guidance in landscape environment,Luminaire Type complete all as specified and as directed by Engr-in-Charge. Make Havells Cat No. BAMBOOBLS8WLED857PSYMTOPC(0.6M) OR Equivalent in make as specified in appendix 'B' as approved by GE.
Supply and fix in repairs of street light bracket made out of 40mm dia medium grade GI pipe of 1.5 m long bend to shape including single coat of aluminium pait over a coat of red primer painting complete.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 140mmx140mmx100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron all as specified and directed. Make : Sintex or equivalant as specified in appendix 'B' as approved by GE.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300mm X 200mm X 105 mm (internal ) comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron all as specified and directed. Make : Sintex or equivalant as specified in appendix 'B' as approved by GE.
Material and labour for 3 single core PVC insulated unsheathed copper conductor cable multistranded 2x 2.5 +1x1.5 sq mm passing through in steel pole DB to street light luminaires including replacing the un serviceable NOTE :- 3 run of wire shall be measured as one length
Supply install test and commissioning LT cubical street light timer panel (CPRI approved)confirming to relevant IS factory fabricated made out of 3 mm thick out door type CRCA sheet duly powder coated & suitable size to accommodate all accessories/fittings with 10 sqmm connecting copper power wire, suitable angle iron frame with following accessories compartmentalize in construction to accommodate incoming/outgoing cables and connecting copper wire including foundation for fixing angle iron frame for timer panel. Comprising of the following:- a) Digital 24 Hrs Timer b) Power contactor 63 Amps A3 - 01 c) MCB TPN 63 Amps 10 KA three pole 415 Volts. d) Bakelite fuse cut out single phase, 63 Amps-03 Nos e) Indication lamp RYB-01 set. Make : Havells/Philips/Wipro
Supply and fixing in replacement Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kW load equally distributed over 3-phase .Contactor Rating: 40.Amps (4-pole).MCB (single-pole) Rating: 40.Amps (3 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T Make:SWADEEP – 02EC 12kW3P
Material and labour for cutting of roads/ plinth for removal/ lalying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate as in foundations of for making good road/ foot path/ hard standing/ drain/ bldg plinth protection all as specified and directed.
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
SKS Electricals
ASHA ASSOCIATES
R. K. Industrial Fabricators
Borole Electricals
Tulsani Associates
M/S - KRUPA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .