| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.9 L+₹33,342.60 (0.73%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹47.0 L+₹1.4 L (3.12%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical DADRA AND NAGER HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | - | Rejected-Technical Document not submitted as per tender terms and condition, hence disqualified. |
Tender Value
Refer Docs
EMD Value
₹86,969
Closing Date
6 Jul 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Exe., Engg., PWD, WD-I, Daman.
The Multi Office Complex, 2nd Floor, Near Moti Daman Market, Moti Daman.
Repair and renovation at office, Garage and Store in CHC, Moti Daman. (E-23601)
2021_DAMAN_1650_1
Tender Notice No. 16/02/2021-22
Open Tender
Civil Works
Works
60 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
The Exe., Engg., PWD, WD-I, Daman.
₹86,969
23 Sept 2021
24 Jun 2021
6 Jul 2021
24 Jun 2021
6 Jul 2021
24 Jun 2021
90 days
Amount
Civil work
Demolition of Brick work,RCC Work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all leads upto 5 Km including and lift. (i) In Lime Mortar. etc complete as directed by engineer-incharge.
Demolition of Water Proofing terrace including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) Brick tile covering.
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) A.C. sheet roofing.
Providing material, Equipment and labour forExcavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(C) Hard Murrum complete as directed by engineer-incharge.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm
Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. :Providing material and labour charge for fixing POWDER COATED ALLUMINIUM PARTITION with Pipe section 63mm x 38mm x 1.63 mm including glazing clips and 25mm x 25mm x 1.80 mm having cross section C/C not more than 0.5 x 1.00 meter and Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge with Frosted/Clear Glass Planes of 6.0mm thickness and/or 4mm Thick ACP Sheet of color as approved by engineer-incharge fitting with rubber gasket and other fixture and fastening etc. complete as directed by Engineer in charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. :Providing material and labour charge for fixing Powder coated (50 Microns) Alluminium DOOR with pipe section 63mm x 38mm x 1.63 mm including glazing clips and 25mm x 25mm x 1.80 mm having cross section C/C not more than 0.7 x 1.00 meter and using Hardnersheet / Clear / Frosted Glass 6.0mm thick and/or 4mm Thick ACP Sheet of color as approved fitting with rubber gasket etc complete, Including Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.and Door closer etc. complete as directed by Engineer in charge with stainless steel cover plate minimum 1.25mm thickness, with Providing and fixing S.S. Door handles(Heavy) with screws etc 200mm long on both side, including Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete as directed by Engineer-incharge.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete
Providing and fixing Precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as diected by Engineer-in-charge.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete as directed by engineer-in-charge :Ridges plain (500 - 600mm)
Providing Material, Labour and equipments for Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thickjointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : including Khurra & Gola work With average thickness of 120 mm and minimum thickness at khurra as 65 mm, etc complete as directed by engineer-incharge.
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of read lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like (upto 10 ton)
Providing and laying broken chine mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 (using water proofing chemical in mortar) to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall,clearing with water and oxalic acid etc. as directed by engineer-incharge.
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey cement slurry including rubbing and polishing etc. complete. (B) 30 mm thick (upto 10 ton) as directed by engineer-incharge.
Providingand fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building.
Applying two coats of Birla (white cement based) or Asian (acrylic lapy- putty) or equivalent & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Applying priming coat over new steel and other metel surface after and including preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead. Painting two coats on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust and other foreign matter.
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories. Cat IIIMake of switch and board: Havells/Anchor/Legrand/L&T .
Providing Modular Type Accessories with 16 Amp SP one way switch & 5 pin 6/16 Amp Universal socket mounted with pvc /metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection.Make of switch and board: Havells/Anchor/Legrand/L&T .
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with 20 Amp. Plug socket, company fabricated powder coated sheet steel enclosure erected as directed with connection. Make:Legrand/Havells/anchor. [A] Metal Clad Socket with metal clad top Make: Havells/Anchor/Legrand/L&T
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate optics with company mark/name 120 to 300 V,Power Factor more than 0.9, THD < 10 %, CCT 4000 K to 6500K, Uniformity ratio >0.7, Luminaire efficiency> 85 lumens/watt , LED driver efficiency > 85 % CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates). Tube Light with integral/ non-integral driver. 20-22 Watts, Surge - 4KV,IP-20, 4 feet.Cat-III Make:Wipro,Havells,Philips,Bajaj.
Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2 , 3 core flexible wire with earthing. Make: ANCHOR/BAJAJ/USHA/ORIENT/CROMPTON.
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection.Electronic hum Free four or more steps EME Fan regulator.Cat III.
Supplying and erecting approved make Bracket fan of 230 volt, A.C. 50 Cy/s., 400/450 mm sweep complete erected on wall or with ead Cores and connections complete.Make: ANCHOR/BAJAJ/USHA/ORIENT/CROMPTON.
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of 2 wire 4 sq. mm size with medium class Rigid PVC pipe and accessories. Make:-Polycab/RR Kabel/Finolex/Havell’s.
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of 2 wire 2.5 sq. mm size with medium class Rigid PVC pipe and accessories. Make:-Polycab/RR Kabel/Finolex/Havell’s
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark.Cat III. Make:Legrand/Havells/anchor.
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having 40 Amp capacity
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having 63 Amp capacity.Cat III.Make:Legrand/Havells/anchor.
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) Single phase 12 way SS Double door.
Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS with (B) With 45 x 45 x 0.35 cms. C.I. earth plate.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Sypply & fixing decorative Hanging light with glass having cylindrical or squre shape having length not less than 10" & width not less 3.5" with holder, lead wire as per required length but not more than 1mm & base plate for fixing the fitting with ceiling.with One Nos. 36 watt PLCFL
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95, THD < 10 %, CCT 5000 K to 5700K, Uniformity ratio >0.45, Luminaire efficiency> 85 lumens/watt . LED driver efficiency > 85 %. CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) make LED used for luminaire. ( Each fittings required LM-79 & LM-80 certificates) Street Light (IP-65), Surge -4KV, above 36 to 48 watts,Make:Wipro,Havells,Philips,Bajaj.
Providing and erecting approved make split air-conditioning unit consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 5 RMT suitable for (Cost includes M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control) For 3 Star Rating,for 2 ton capacity.make:- Voltas, Bluestar, Lloyd.(As directed by Engineer in charge). Certified that the Rates adopted in this estimate are taken as per Gujarat Schedule of Rate (Valsad) Civil , Electrical 2015-16, and Also required Rate - Analysis is included in the estimate.
NAUSHAD M HASNANI
SHIV CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .