Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.4 L+₹86,832.57 (7.52%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.2 L+₹3.6 L (31.4%)Rejected-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.4 L+₹3.9 L (33.5%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC L4 | |
| 5 | L5₹15.6 L+₹4.1 L (35.4%)Rejected-AOC BETONG SHOP KHANGSAR COMPLEX NOWSHARA LEH LADAKH 194101 J K | LEH | LEH | JAMMU AND KASHMIR | 194101 | L5 | Rejected-AOC L5 |
Tender Value
₹17.4 L
EMD Value
₹34,900
Closing Date
24 Aug 2020, 6:00 pmClosed
GE KHUMBATHANG
GE KHUMBATHANG C/o 56 APO
GE/KHU-26/2020-21 PROVN OF CEMENTED FLOORING, KOTA STONE FLOORING, ADDN/ALTN OF TILING, 02 X GARBAGE BINS AND SPECIAL REPAIR/ REPLACEMENT OF EXISTING LT UG CABLE NETWORK TO OH LT NETWORK, SPECIAL REPAIR TO WIRING IN BLD NO T-01,T-06, T-12, T-21, T-19
2020_MES_364197_1
GE/KHU-26/2020-21
Open Tender
Civil Works
Item Rate
180 days
AGE B/R-I KHUMBATHANG
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KHUMBATHANG
₹34,900
Yes
9 Mar 2021
26 Jul 2020
25 Aug 2020
26 Jul 2020
24 Aug 2020
10 Aug 2020
Amount
Surface excavation n. exc 30 cm deep and averaging 15cm and getting in any type of soil complete all as specified and directed.
M & L Hard core, of broken stone aggregate/ boulders to gauge n exc 63 mm , spread and levelled in layers n exc. 15 thick watered and well rammed to true surfaces as required complete all as specified.
Material and labour for 100 mm thick Plain Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and as directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified.
M & L roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove duct etc complete all as specified.
M & L 25 mm thick PCC 1:2:4 typeB-1 with using 20mm graded stone aggregate as in subbase and finishing the surface even and fair without using extra cement complete all as specified and directed.
M/L Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M/L machine cut Kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing erviceable tiles to store and rubbish off the premises complete all as specified.
M & L screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
Taking down cement plaster on brick wall/stone wall, ceilings etc, racking out joints, hacking for key & scrubbing with water completely complete all as specified.
M & L Glazed ceramic tiles coloured (350x200x7mm/ 450x300x7mm) for works on vertical surfaces such as skirting/dados of economy class B-III conforming to IS-13712 etc set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10 mm thick in cement mortar 1:3, as in backing layer without using extra cement complete all as specified.
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in flooring.
M&L 40mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth using extra cement.
M&L PCC in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B1 (1:2:4) using 20 mm graded aggregate.
M&L PCC 75 mm thick type B-1 1:3:6 (20 mm graded agg) as in filling with finishing surface even and smooth in plinth protection with using extra cement complete all as specified.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even & fair (without using extra lime or cement) all as specified and directed.
M&L for applying two coats of cement based paint over concrete or newly plastered suraces incl preparing new plastered surfaces.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick,conforming to IS 13801: 1993, crack proof, machine cut, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment complete all as specified.
S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Fe 410-W (Gde- E-250) quality A
M&L for preparation of steel and iron new surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete
Excavation in trenches in any type of soil n.exc 1.5mtr wide and n.exc 1.5mtr deep for laying of cable and getting out old UNSV cable from trenches and for foundation, etc or n. exc 10 sqm on plan and n. exc 1.5 m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any typ of soil complete all as specified.
All as per Srl No 23 here-in-before but depth exceeding 1.5 metre but not exceeding 3.0 metre complete all as directed by Engr-in-Charge.
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25cm each in soft/loose soil complete all as directed by Engr-in-Charge.
Removing surplus spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as directed by Engr-in-Charge
Material & Labour PCC 1:3:6 type C1 ( using 20mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified.
Material & Labour PCC 1:3:6 type C2 ( using 40mm graded stone aggregate) as in coping of poles and stay etc complete all as specified.
Material & Labour PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in foundation of poles, stay and garbage bin etc complete all as specified.
M&L for Structural steel work in replacement of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts, bolts, washers, welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primercoat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M& L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long)
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings such as switches, ceiling reose, pendents, regulator sockets etc, removing material from site and making good the disturbed surfaces of wall/floor/roof all as specified & directed by Engr-in-charge.
Material & Labour for point wiring with 1.5 sq mm (Nominal area) FRLS, PVC insulated, 1100 volt grade, multistranded copper conductor cable un-sheathed in & including PVC casing caping with fittings/accessories and PVC insulated, FRLS, 1100 volt grade un sheathed copper conductor of 1.5 sqmm size cable earth wire connected to common earth including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting of switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet of Hylam/Mica make as top cover complete all as specified for the following:- (a) One light point/fan point/buzzer point Exhaust fan point controlled by one switch.
(b) One 3 pin socket out let 5 Amp on independent board complete
Description all as per item No.2 here-in-before but with cable conductor 2.5 sq mm (Nominal size) & earth wire of 2.5 sqmm for socket outlet 15 Amp on independent board complete
Supply and Fixing in repair switch piano flush button type 5 Amp single pole one way (ISI marked) complete.
Supply and Fixing in repair switch socket combination outlet multipurpose 3/5 pin15 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair socket out let multipurpose three pin 5 Amp and 2 pin 5 Amp flush type complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair ceiling rose three terminal pvc/polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair lamp holder ,PVC/Polycarbonate type with back plate suitable for batten fitting (angle /plain) complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Bulb of capacity 5 watt complete all as specified and directed by Engineer-in-Charge.
S&F in repair E-LitE LED Pride plus LED 18W for Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack., 230volts, 50 Hz including making necessary connection prewired and making connection with 3 core copper flexible cable of appropriate size from ceiling rose/PVC connector to light fittings complete all as specified and directed.
Supply & fix in repair Enduara flat pannel ultra slim energy efficient recessed mounted LED 36 watt 6000K luminaire suitable for 2X2 grid ceiling out put of including LED lamps and taking down old and unsv fittings from site complete all as specified and directed.
S&F in repair two single core 4 Sqmm for Sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100Volts grade in and including PVC casing capping/ pvc conduit with fixing accessories including one run of 2.5 Sqmm copper conductor. (Note - Two runs of 04 Sqmm cable, one run of 2.5 Sqmm earth cable and one run of PVC casing Capping shall be measured as one running meter.)
S&F building security light of 36 Watt including GI bracket all as specfied and directed by Engr- In- Charge Make Philips cat part No BRP052 LED 036 CW HP SLA FG S1 PSU GR
S&F in repair sheet metal enclosure MCCB, DB, TPN, double door load line vertical device 4 way with 200 Amps rated bus bar including incoming MCCB 63 Amps 25 KA 04 pole complete all as specified and directed by Engineer-in-Charge
S & F in repair 4 way pressed sheet metal enclosure (MCB DB), three phase and neutral with 200 Amps rated bus bar, double door type, 415volts complete all as speified and directed.
S & F in repair 8 way pressed sheet metal enclosure (MCB DB), single phase and neutral with 200 Amps rated bus bar, double door type, 240 volts complete all as speified and directed.
M&L in repair for Circuit breaker triple pole and neutral, 63 Amp 415 volt C curve 10 KA, IP 20 complete all as specified and directed incl taking down old one
M&L in repair for Circuit breaker single pole & neutral 240 volt B curve 10 KA 40 Amps capacity IP 20 complete all as specified and directed incl taking down old one
M&L in repair for Circuit breaker single pole & neutral 240 volt B curve 10 KA 5 to 40 Amps capacity IP 20 complete all as specified and directed incl taking down old one
Material and labour earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled around with 15 cm thick alternate layers of charcoal dust and salt and connected to earth lead wire 4mm dia (8 SWG) by means of bolt, nut and check nuts and washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, pcc 1:3:6 type C-1 in chambers PCC 1:2:4 type B-1 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways all as directed by Engr-In-Charge, complete all as shown in electric plate No 3 of MES SSR Part I of 2010.
Supply & fix in repair on load changeover switch conforming to IS 13947 part 3/93 compact body of fiber glass, reinforced polyester resin, 415 V three phase with side handle of capacity 63 Amps complete all as specified and directed.
Supply & fix in repair on load changeover switch conforming to IS 13947 part 3/93 having compact body of fiber glass, reinforced polyester resin, 415 V three phase with side handle of capacity 32 Amps complete all as specified and directed.
Supply, laying and testing cable in replacement XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable in replacement XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
S&F in replacement GI pipe Light grade 40 mm for passing through cables under the floor, along the walls, along the poles or across the roads with proper clamps, nut & bolts including taking down old complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core.
S&F GI pipe Light grade 80 mm passing through cables, walls,across the roads with proper clamps, nut & bolts including complete all as specified and directed.
Material & Labour for Sand cushioning in trenches complete.
Supplying and laying in replacement un-reinforced precast concrete cable cover,class LV,type-1,flat,size 250mmx150 mm x40 mm complete all as specified and directed.
Material and labour for ACSR conductor squirrel to dog (6/1/2.59 to 6/1/2.11) any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed
M&L for galvanized iron steel wire drawn straight horizontal as continuous earth wire on existing LT poles of size 4.0 mm dia .
M&L for replacement of Pin type, polymer type, insulator for 1.1 kv complete all as specified and directed
Taking out the UG PVC insulated armourned / un armoured PVC sheathed laid in trenches / passing through GI tubing / on pole / on wall of any size and any type all as directed
Suply and fixing in repair Exuast fan, Ventil Air - DX White with louvers plastic body suitable for 250 mm dia sweep complete with fixing accessories including making hole as per site requirment for suitable size all as specified and directed
Deduct Credit for Demolished/Dismantled material Rs (-) 25,159.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
SUMEET TRADING CORPORATION
DEEP ENTERPRISES
SINGH CONST CO
Siachen Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .