Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC 2A SUBODH BANERJEE ROAD KOLKATA BARISHA WEST BENGAL PIN 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹23.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹23.9 LRejected-Finance 4A KALICHARAN GHOSH ROAD KOL 50 | KOLKATA | WEST BENGAL | ₹23.9 L | L2 | Rejected-Finance L2 |
| 3 | L3₹24.0 LRejected-Finance | ₹24.0 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Requisite part of license- Part no. 4 not found. |
Tender Value
₹23.3 L
EMD Value
₹46,613
Closing Date
20 Feb 2026, 3:00 pmClosed
O/o THE EE/MED
Office of the Executive Engineer Metropolitan Electrical Division Block-DF, Sector-I, 4th Floor, Jalasampad Bhawan, Salt Lake City, Kolkata -700091
Electro-mechanical Operation and Maintenance of Nazirganj 8 vented Sluice at Nazirganj over Howrah Drainage Canal, 4 vented Sluice at Sarenga over Borojola Khal..to be executed through Metropolitan Electrical Division during the year 2026-27.
2026_IWD_1000164_2
WBIW/EE/MED/e-NIT-24/2025-26
Open Tender
MECHANICAL
365 days
NAZIRGUNJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹46,613
12 Jun 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
Engagement of personnel for E.I. Maintenance Hydro mechanical gate work of Sub- Division office building, office campus,Residential quarter of Howrah Drainage Sub- Division with operation & running maintenance of 8 vented (Eight) nazirgunj Sluice gate under EE-I/ lower Damodar Construction Division at Nazirgunj comprising the maintenance of FASD statrter panel, mainpanel, P.B.D.B B.D.Bs switches, tube light fittings, celing fans and call bells including earthing, making addition and alternation and changing of electrical equipment etc. if any as per direction of E.I.C. (Nazirgang)
Engagement of 01(One ) no Electrician, 1 Man. X365 days = 365Manday. (Contractor should arrange his own tools and tackles for the job. Labour rates are inclusive of GST, Cess, ESI, EPF, Bonus, CP & OH T & P charges)
Engagement of 02 (Two) no Helper for Electrician /day, 1 nos helper x 2 shift, 365 days = 700 mandays.
Additional manpower for operation gate 1 no helper electrician during drainage period from 01.07.26 to 15.11.2026 (July to November '25 ) = 45 day x 1 no helper=45 manday asper direction of EIC (Rates are inclusive of Basic rate, 2% O.H T &P and 10% C.P)
Engagement of Mechanical working personal for Hydromechanical sluice gate Maintenance( seasonal & emergency ) and manual operation of Flap shutter as and when require of 8 vented (Eight) nazirgunj Sluice gate under EE-I/ lower Damodar Construction Division at Nazirgunj comprising premonsoon oiling ,greasing , checking all mechanical parts like gear, winch , roap drum all nuts & bolts, change & adjust all system upto satisfactory performance , materials supplied by the department.
Engagement of 01(One) no Mechanic, 1 Man. X12 days = 12 mandays for premonsoon servicing + additional 12 mandays for emergency break down servicing as require as per instruction of EIC.[Total = 12+12mandays = 24 Mandays] (Rates are inclusive of Basic rate, 2% O.H and 10% C.P) (Contractor should arrange his own tools and tackles for the job.
Engagement of 01(One) no Helper Mechanic/ day,1 Man. X 12 days = 12mandays for premonsoon servicing . + additional 12 mandays for emergency break down servicing as require as per instruction of EIC.[Total =12+12 Mandays = 24 Mandays]. (Rates are inclusive of Basic rate, 2% O.H and 10% C.P) (Contractor should arrange his own tools and tackles for the job.
Additional manpower for Manually Operation and cleaning of Flap shutter as required through out the year (drainage & irrigation period ) with in AMC by engaging 1 no Mazdoor (male) x 48 days= 48 Mandays (Rates are inclusive of Basic rate, 2% O.H and 10% C.P)as per direction of EIC.
Engagement of Electrical working personal for Hydromechanical sluice gate operation and Maintenance and manual operation of Flap shutter as and when require of 4 vented ( Four ) Sarenga Sluice gate under EE-I/ lower Damodar Construction Division at Sarenga over Borojola Khal comprising operatiion and maintenance starter panel, motor , and alllied all electrical installation , lights etc throughout the year. (Sarenga)
Engagement of 01(One) no Electrician, 1 Man X 336 days = 336 Mandays. (Contractor should arrange his own tools and tackles for the job. Labour rates are inclusive of GST, Cess, ESI, EPF, Bonus, CP & OH T & P charges).
Engagement of 01(Two) no Helper for Electrician/ 2 shif /day, 2 shift x 1 nos helper x 365 days = 700 mandays.
Additional manpower for operation of gates and Flap during drainage & irrigation period (from 01.07.26 to 31.03.27) 10days (1 no helper x 10 day = 10 Mandays). as per direction of EIC. (Rates are inclusive of Basic rate, 2% O.H T &P and 10% C.P)
Engagement of Mechanical working personal for Hydromechanical sluice gate Maintenance( seasonal & emergency ) and manual operation of Flap shutter as and when require of 4 vented (Four) Sarenga Sluice gate(over Borojola khal) under EE-I/ lower Damodar Construction Division comprising premonsoon oiling ,greasing , checking all mechanical parts like gear, winch , roap drum all nuts & bolts, change & adjust all system upto satisfactory performance , materials supplied by the department.
Engagement of 01(One) no Mechanic, 1 Man X 12days = 12mandays for premonsoon servicing + additional 12 mandays for emergency break down servicing as require as per instruction of EIC.[Total = 12+12manday= 24 Mandays] (Rates are inclusive of Basic rate, 2% O.H and 10% C.P) (Contractor should arrange his own tools and tackles for the job.
Operation and cleaning of Flap shutter as required through out the year (drainage & irrigation period ) with in AMC as per requirement 1 no x 24 days = 24 mandays
Supply of following consumable electrical spares / materials within the provision of the following items as and when required upto the limit of :
Supplying of different types of LED lamps (9W),Crompton make, LED 9W - B22 - CDL.
Supply of different sizes GI modular switch boxes of following sizes, Make: Anchor/euivalent
2 module GI box
4 module GI box
Motor starter panel accessorries and power controll spare for gate repaire & servicing item.
Supply of 22.5 mm Hole Dia Mushroom Type Push Button switch
Supply of 22.5 mm dia LED indicating lamps
Supply of 3 pole power contactor type ML 1.5, 25A current rating
Supply of 3 pole power contactor type ML 2, 40A current rating
ML1.5 Spare Contact KIT,Make : L & T
ML1.5 Spare Contact Coil, Make : L & T
ML1.5 thermal overload relay Direct Mounting on ML 1.5 Contac, 4-6.5 Amp, Make : L & T.
Direct On Line (DOL) Starter MU 2P DOL Starters Suitable for Pump/Motor 1Ø, 230V, 50Hz, Make : L & T, 1 Hp 6-10 Amp
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 32 A, DP, Legrand.
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid GI wire, No. 10 SWG
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
ISI-M , 40 mm dia.
ISI-M , 80 mm dia.
ISI-M , 100 mm dia.
Supplying of following XLPE insulated Aluminium conductor armoured Cables of 1.1KV grade as Per IS 7098 ( part- I) 1988 with up to date amendments, (Rate in Rs. Per Mtr.)
4 CORE 50 sq.mm
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI,Pipe/open masonary trench for single, 2, 3, 3½ & 4 core.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials,
3.5C x 70 sq. mm,
Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (100 A Havells)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Havells:2+12 way)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Havells:40 A)
Supply and fixing of Havells Post top Luminaries model no : CORAL PT35WLED (35Watt) over the preinstalled GI Pipe over the gate structure or similar structure incl. connection by 1.5 sq mm cu wire from loop box to the light.
Cable end box (16SWG) for TPN SFU enclosure 125A
Worm Reducer ( Under driven/ Over driven) Center Distance 8"
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.88 MB
BOQ_2450109.xls
BOQ • 0.39 MB
2911.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid