Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.0 LAccepted-AOC KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹55.9 L+₹1.8 L (3.39%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹56.3 L+₹2.2 L (4.14%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹56.3 L+₹2.2 L (4.16%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹56.7 L+₹2.6 L (4.88%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L5 | Rejected-Finance Not lowest |
Tender Value
₹68 L
EMD Value
₹1.3 L
Closing Date
29 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF AMBALA
HQ CWE AF AMBALA Ambala Cantt
CONVERSION OF LT OVERHEAD LINES TO UNDER GROUND CABLES AND OTHER ASSOCIATED WORK SERVICES AT AF STATION BARNALA UNDER GE (AF) HALWARA
2022_MES_509475_1
CWE/AF AMB/HAL-51/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Barnala under GE AF Halwara
For enlisted in MES Class C and category b i and for unenlisted refer NIT
7 documents required · 7 mandatory
₹1,000
GE AF HALWARA
₹1.3 L
Yes
20 Apr 2022
21 Feb 2022
31 Mar 2022
21 Feb 2022
29 Mar 2022
15 Mar 2022
21 Feb 2022 - 10 Mar 2022
60 days
Amount
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed. Note: The excavation work shall be executed manually only by labourers.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified & directed.
M&L Sand cushioning to cable with a layer of dry coarse sand 8cm thick before laying the cable and 15cm thick after laying the cable (punned down to 18cm thick after laying and stretching of cable ) complete all as specified & directed.
Supply and laying old size, common burnt clay, sub class 'B' bricks, designation 75, laid flat & dry for protection of cable in trenches, adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Supply, laying, jointing, testing and commissioning LT electric cable, 1100 Volts grade, heavy duty, XLPE insulated, armoured electric power cable with aluminium conductor of cross sectional area 6 sqmm, 4 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 10 sqmm, 2 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 10 sqmm, 4 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 16 sqmm, 4 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 25 sqmm, 4 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 35 sqmm, 2 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 35 sqmm, 3.5 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 50 sqmm, 3.5 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 70 sqmm, 3.5 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 95 sqmm, 3.5 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 150 sqmm, 3.5 core.
Description all as per BOQ item No. 6.00 here-in-above but cross sectional area 240 sqmm, 3.5 core. Notes for BOQ item No. 6.00 to 17.00:- (i) Cable shall be of manufacturing date not earlier than Sep 2021. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, end termination joints, protection pipes & protection covers etc. shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) Cable shall be tested in the presence of GE or rep of GE after laying in the trenches & before returning filling in the trenches.
Supply, installation, testing & commissioning LT Panel, Outdoor type, double door, dust and vermin proof, totally enclosed, platform mounted, factory made, having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40mm x 40mm x 6mm duly painted including necessary foundation/platform of PCC 1:2:4, type B-1 of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 600 Amps & shall be complete with internal wiring with copper conductor and including following undermetioned accessories complete all as specified & directed:- (A) Main Incoming:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 400 Amps, 415 volts, 50 Hz, rupturing capacity 36KA, with adjustable thermal and adjustable magnetic setting - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 No. (iii) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set
(B) Main Outgoing:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 160 Amps, 415 volts, 50 Hz, rupturing capacity 25KA, with adjustable thermal and fixed magnetic setting - 04 Nos. (ii) MCB 4 pole, 32 Amps, 10 KA, C Curve - 01 No. (iii) MCB 2 pole, 32 Amps, 10 KA, C Curve - 02 Nos
Supply, installation, testing & commissioning LT Panel, Outdoor type, double door, dust and vermin proof, totally enclosed, platform mounted, factory made, having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40mm x 40mm x 6mm duly painted including necessary foundation/platform of PCC 1:2:4, type B-1 of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 600 Amps & shall be complete with internal wiring with copper conductor and including following undermetioned accessories complete all as specified & directed:- (A) Main Incoming:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 400 Amps, 415 volts, 50 Hz, rupturing capacity 36KA, with adjustable thermal and adjustable magnetic setting - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 No. (iii) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set
(B) Main Outgoing:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 160 Amps, 415 volts, 50 Hz, rupturing capacity 25KA, with adjustable thermal and fixed magnetic setting - 02 Nos. (ii) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 125 Amps, 415 volts, 50 Hz, rupturing capacity 25KA, with adjustable thermal and fixed magnetic setting - 02 Nos. (iii) MCB 4 pole, 32 Amps, 10 KA, C Curve - 01 No. Notes for BOQ item No. 18.00 & 19.00: (i) The cost of Earthwork(if any) & PCC foundation/platform of size as directed by Engineer-in-charge deemed to be included in quoted rates. (ii) Layout diagram of LT panel shall be produced by contractor for approval of Accepting Officer through GE before placing order to manufacturer and panel shall be brought at site as per approved drawing. (iii) The MS angle iron frame work shall be painted with two coats of synthetic enamel paint over & including one coat red oxide primer.
S&F in replacement of junction box, made out of thermoplastic polycarbonate, size should be not less than 155mm x 210mm x 92mm(upto cable size 16sqmm). JB Protection IP 66/67 with IEC 60529 & Polyurethane internally embedded Gaskit not pasted. The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. JB Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box shall be black colour according to RAL 9011. The Polycarbonate enclosure shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. JB with terminal strip & MCB single pole 'C' Curve 6/10Amp and chromium plated clamps and nut bolts all as per manufacturer’s instructions including fixing with MS clamp and nut bolt on exixting steel/PCC pole complete all specified & directed. Note:- (i) The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate.
S&F or passing through pipe, PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade, heavy duty cable, 3.0 core, 1.5 sqmm nominal cross section & connections from junction box to light fitting complete all as specified & directed.
S&F cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old cross arm etc. complete all as specified and directed.
S&F in replacement street light timer box company made, three phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a enclosure and mounted on angle iron plateform with PCC work on ground complete all as specified & directed Note:- The PCC work & MS frame work as directed by Engineer-in-charge included in quoted rates.
S&F Busbar box (Busbar chamber box ) of LT , 415 Volt, 100 Amps, 8 Way, triple pole & neutral, aluminium busbars fixed on angle iron frame with nut bolt/wall including providing the electrical connection for incoming /outgoing cable through proper lugs/thimbles complete all as specified & directed.
S&F in replacement MCCB 63 Amps, four pole, confirming to IS/IEC 60947-2, IEC 60947-2 & EN 60947-2 breaking capacity Icu(KA)AC : 10KA@ 415volt AC, 50Hz/60 HzDC : 16KA@ 250volt DC including spreader terminals and mounting in existing panel in spare MCCB box including making connections with 10sqmm copper cable from MCCB to busbar of panel complete all as specified & directed.
Supply, installation, testing & commissioning LT Feeder Pillar box, Outdoor type, double door, dust and vermin proof, totally enclosed, platform mounted, factory made, having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40mm x 40mm x 6mm duly painted including necessary foundation/platform of PCC 1:2:4, type B-1 of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 400 Amps & shall be complete with internal wiring with copper conductor and including following undermetioned accessories complete all as specified & directed:- (A) Incoming:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (04 Pole) 250 Amps, 415 Volts, 50Hz, rupturing capacity 36KA, with adjustable thermal and magnetic setting - 01 No. (ii) Intelligent Panel meter to measure voltage, current, frequency, power factor kWH, etc with all connected CTs. - 01 No. (iii) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
Supply, installation, testing & commissioning LT Feeder Pillar box, Outdoor type, double door, dust and vermin proof, totally enclosed, platform mounted, factory made, having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40mm x 40mm x 6mm duly painted including necessary foundation/platform of PCC 1:2:4, type B-1 of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 300 Amps & shall be complete with internal wiring with copper conductor and including following undermetioned accessories complete all as specified & directed:- (A) Incoming:- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (04 Pole) 160 Amps, 415 Volts, 50Hz, rupturing capacity 25KA, with adjustable thermal and magnetic setting - 01 No. (ii) Intelligent Panel meter to measure voltage, current, frequency, power factor kWH, etc with all connected CTs.- 01 No. (iii) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
M&L boring of road crossing of size 100mm dia at suitable depth (not more than 1 mtr) by using machinery / equipments complete without damaging the surface for passing pipes / cables etc including removing excavated soil to a distance not exceeding 50mtr complete all as specified & directed. Notes : (i) Location of boring holes shall be decided by the Engineer-in-charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil.
M&L GI pipe 15mm bore , light grade, for cable protection as in road crossing under road/path, under floor/plinth protection, fixed to wall/pole with fixing arrangement with suitable size of MS clamps, nuts,bolts & washers, including cutting chasing(if required) of plinth protection or wall & making good to disturbed suface as per existing complete all as specified and directed .
Description all as per BOQ item No. 29.00 here-in-above but GI Pipe 40mm bore.
Description all as per BOQ item No. 29.00 here-in-above but GI Pipe 80mm bore.
Description all as per BOQ item No. 29.00 here-in-above but GI Pipe 100mm bore.
M&L submain wiring with two single core FRLS, PVC insulated but unsheathed cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated but unsheathed 6 sqmm stranded copper conductor earth continuity cable drawn through in & including PVC casing caping (ISI marked) medium grade (size minimum 25mm wide) including accessories as in wall/floors/roof etc complete all as specified and directed. Note :- Two runs of 6 sqmm cable & one run of 6 sqmm cable as earth wire alongwith casing caping shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
S&F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface/flush mounted Vertical TPN DB, 4 way including 63 Amp 4 pole MCB as Incomer, 415 Volts, ISI marked 200 amps busbar, stove enameled, dust and vermin proof confirming to IP-54 and IS 8623-1 & 3, IEC 61439-1 & 3 including cutting chasing of wall for flushing of VTPN DB and making good of distrubed surface with cement mortar complete all as specified & directed.
S&F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SPN 8 way, 240 Volts, ISI marked, 200 amps busbar, stove enameled, dust and vermin proof suitable for incorporation of MCBs & isolators etc complete all as specified & directed. Note:- MCBs shall be measured & paid seperately.
S&F in replacement 63 Amp, SPN MCB ‘C’ series type suitable for 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified & directed.
S&F in replacement 32 Amp, SP MCB ‘C’ series type suitable for 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified & directed.
M&L submain wiring with two single core FRLS, PVC insulated but unsheathed cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated but unsheathed 4 sqmm stranded copper conductor earth continuity cable drawn through in & including PVC casing caping (ISI marked) medium grade (size minimum 25mm wide) including accessories as in wall/floors/roof etc complete all as specified and directed. Note :- Two runs of 4 sqmm cable & one run of 4 sqmm cable as earth wire alongwith casing caping shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
S&F in replacement Metal cald enclosure SPN with a two pin & earth plug and socket & including one MCB 20 Amps, SP, C curve complete all as specified & directed.
S&F MCB 32 amp, 415volt, 10KA TPN fixed with & including plastic enclosure near existing MCB DB and making connection as distribution of three phase with Existing DB complete all as specified & directed.
(v) Single phase static energy meter of accuracy class 1.0, 240 volt, 50 Hz with Backlit LCD display of rating 10 - 60 Amp, (measures and displays KWH ,Volt, Current I, KW, PF last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power - 08 Nos. Notes: (i) The cost of Earthwork(if any) & PCC foundation/platform of size as directed by Engineer-in-charge deemed to be included in quoted rates. (ii) Layout diagram of LT panel shall be produced by contractor for approval of Accepting Officer through GE before placing order to manufacturer and panel shall be brought at site as per approved drawing. (iii) The MS angle iron frame work shall be painted with two coats of synthetic enamel paint over & including one coat red oxide primer. (iv) Necessary earthwork in any type of earth strata for finding out the loops of connecting cables to new panel foundation are deemed to be included in the quoted rates. Fixing of MCCBs, Meters,,CTs. Jointing and extending of existing LT UG cables any sizes if required at site is deemed to be included in the rate quoted. PVC sleeves or insulation compound shall be provided everywhere over all LT cables inside of panel from lugs/thimble to gland at bottom side in the panel without any extra cost. Knob (switch on/off) position of MCCBs should be perpendicular (upword and down direction) to GL
S&F AC three phase static energy meter of accuracy class 1.0, 415 volt, 50 Hz with Backlit LCD display of rating 10 - 60 Amp, (measures and displays KWH, Volt, Current I, KW, PF, last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power alongwith Non metallic electric meter box , outdoor type hot moulded SMC meter box concealed hinge,viewing glass, earth bolt, plugged and fixed including 4 pole MCB 32 amps as outgoing, prewired with 10 sqmm copper cable and make connection with existing DBs & main service cable including taking down old energy meter from wall along with box complete all as specified and directed. Note:- Old energy meter shall be deposited at MES store yard with proper documentation.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including rubish off the premises to a distance not exceeding 500 mtr complete all as specified and directed
M&L Plain cement concrete(PCC) 1:2:4 type B-1 (using 20mm graded mechanically crushed stone aggregates) as in coping of poles, concrete base work, protection of cable and mass concrete etc complete all as specified & directed.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead strip 32mm x 6mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20mm bore including protection pipe light grade GI 40mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in any type of soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 40mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with 8mm dia MS bar @ 150mm c/c spcacing both side including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire of 4.0mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20mm bore including protection pipe light grade GI 15mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in any type of soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 40mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with 8mm dia MS bar @ 150mm c/c spcacing both side including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed. Notes for BOQ item No. 45.00 & 46.00:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at no extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Dismantling of existing GI pipe bracket (any size & at any height) including clamp from PCC/steel pole and refixing the same at adequate height with MS nut bolt and clamp as per site requirment and making connections complete all as specified & directed.
Dismantling/taking down of ACSR conductor from Service Feeder or Distributor span including clamp insulator etc complete all as specified & directed
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
R D Bansal
NARESH KUMAR MITTAL
SANGAM ENGINEERS
SWARN SINGH AND CO.
CHOUDHARY ENTERPRISES
JCC ENGINEERS PRIVATE LIMITED
UNITED ENGINEERING CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .