Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹31.8 L+₹6.0 L (23.0%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹32.4 L+₹6.5 L (25.2%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GE NAMS
GE NASM AMRITSAR KHASA CANTT
REPAIR/MAINT OF SUMMER APPLIANCES, CEILING FAN, EXT FAN AND OTHER ALLIED WORKS AT NAMS
2022_MES_542717_1
GE NAMS-51/2022-23
Open Tender
Civil Works
Item Rate
GE NAMS
CLASS D CATEGORY b(i)
7 documents required · 7 mandatory
₹500
GE NAMS
₹72,000
17 Sept 2022
3 Aug 2022
2 Sept 2022
3 Aug 2022
31 Aug 2022
17 Aug 2022
Amount
Water Cooler Servicing/ Inspection of water cooler of any capacity/type/make installed at different units at NAMS on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares/parts complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare/parts required to make the water cooler serviceable shall be measured and paid separately under relevant items however fixing charge of all spares of water cooler shall be deemed to be included in quoted rate. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit and rectify it by gas welding/brazing , charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only of new compressor sealed unit suitable for water cooler of any make/type and 150 ltr/120 ltr/ hr cooling capacity, medium temperature range, including replacement of filter and making connection and detect of leakage and rectifying it by gas welding or any other means etc. including Gas charging of any type refrigerant as required on site including testing of new sealed unit compressor complete all as specified and directed by Engineer-in charge. Make : Kirloskar / Carrier / Tecumseh /Copeland
All as per srl item No 2.00 here-in-before but for water cooler of any make/type and 40/80 ltr/ hr cooling capacity.
Supply only starting relay/Over load protector Complete all as specified and as directed by Engr-in-Charge.
Supply only refrigerant gas of " R-22" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make ,capacity and type complete all as specified and directed by Engineer-in charge.
Supply only of evaporator coil/Condenser coil suitable for water cooler of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
Supply only of Starting/running capacitor ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge. Make – USHA/UNISTAR/TIBCON
Supply only thermostat suitable for any cap. water cooler Complete all as specified and as directed by Engr-in-Charge.
Supply only fan motor with blades of capacity 1/10 to 1/35 HP 50c/s, 230 volts Complete all as specified and as directed by Engr-in-Charge.
Supply only PVC hose waste pipe with SS clamp suitable for water cooler of any capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only drain tray , stainless steel for water cooler of any cap complete all as specified and as directed.
Material and Labour for replacement of old damage rusted water cooler body with new water cooler body fabricated from MS Sheet 18 Guage thick, necessary angle iron work of required size, cleaning, washing the sheet with moderate solution, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including writing MES/SM number with white paint of appropriate size complete all as directed by Engineer In Charge.
Refrigerator:- Servicing /Inspection of refrigerators of any capacity/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares/parts complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare/parts parts required to make the water cooler serviceable shall be measured and paid separately under relevant items.however fixing charge of all spares of refrigerator shall be deemed to be included in quoted rate. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of unit, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit and rectify it by gas welding/brazing and charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only compressor sealed unit alongwith one year guarantee certificate suitable for refrigerator of capacity 165 to 210 ltr of any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line and including gas charging of any type refrigerant as required on site and detect of leakage etc complete all as specified and directed by Engineer-in charge. Make : Kirloskar / Carrier / Tecumseh /Copeland/Godrej/Whirlpool, LG
All as per sr item no 14.00 but of capacity 215-360 ltr Complete all as specified and as directed by Engr-in-Charge.
Supply only refrigerant gas of " R-134a" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make ,capacity and type complete all as specified and directed by Engineer-in charge.
Supply only relay and over load protection relay for refrigerator of any capacity any type Complete all as specified and as directed by Engr-in-Charge./starting relay
Supply only of evaporator coil/Condenser coil suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
Supply only thermostat for refrigerator of any capacity/any type Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of glass/PVC shelf/cover for vegetable tray/ bulb suitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
Supply only PC Board for refrigerator of any make/cap all as specified and as directed by Engr-in-Charge.
Supply only freezer for refrigerator of any make/cap all as specified and as directed by Engr-in-Charge.
Supply only timer/heater for refrigerator complete all as specfied and as directed.
Deep Freezer: Servicing /Inspection of Deep Freezer of any capacity/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares/parts complete as required all as specified and directed by Engineer -in-charge. Note (a) The new spare/parts required to make the water cooler serviceable shall be measured and paid separately under relavent items.however fixing charge of all spares of deep freezer shall be deemed to be included in quoted rate (b) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (c) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same (iv) Detecting the Gas leakage,Vacuuming the unit and rectify it by gas welding/brazing , charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only of new compressor alongwith one year guarantee certificate suitable for deep freezer of capacity 300-400 ltrs and any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line and subsequently Gas charging of gas type as required on site and detect of leakage etc complete all as specified and directed by Engineer-in charge.
All as per sr item no 25.00 here in but for deep freezer of 100-205 ltr capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only fan motor for deep freezer of cap upto 400Ltrs cap Complete all as specified and as directed by Engr-in-Charge.
Split/Window AC: Servicing/ Inspection of AC window/split type of any capacity/type/make installed at different units at NAMS on site, including jet washing,cleaning of filter,coils & checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., finding of defect including dismentling of compressor, blower motor, evaporating coil, relay, thermostat, condensing coil and keeping the AC unit in satisfactory working condition after necessary servicing/ repair including fixing new spares/parts except capacitor, front grill and electronic control circut card complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare/parts except capacitor, front grill and electronic control circut card required to make the water cooler serviceable shall be measured and paid separately under relavent items,however fixing charge of all spares of Split/Window AC shall be deemed to be included in quoted rate. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit and rectify it by gas welding/brazing , charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only of new compressor of capacity 2.0 Ton for window/split type, medium temperature suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, Gas charging (R-22/R-32/R-410A) and detect of leakage etc. and testing of new sealed unit compressor alongwith one year guarantee certificate complete all as specified and directed by Engineer-in-charge. Make :Carrier / Tecumseh /Emerson/ Hitachi/Godrej..
All as per srl item no 29.00 here in but for window/split AC of 1.5 Ton capacity, specifications as per existing Complete all as specified and as directed by Engr-in-Charge.
Supply only condensing coil of copper for window/Split air conditioner of cap 1.5/2 ton capacity as required on site complete all as specified and as directed by Engr-in-Charge.
Supply only refrigerant gas of " R-32/ R 410" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make, capacity and type complete all as specified and directed by Engineer-in charge.
Supply only evaporating coil of copper for window/Split air conditioner of cap 1.5/2 ton capacity as required on site complete all as specified and as directed by Engr-in-Charge.
Supply and fixing, in replacement, of Starting/Running capacitor suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat for window/Split AC of cap1.5/2 ton as per existng make complete all as specifeid and directed.
Supply only micron filter suitable for 1.5/2 Ton window/Split AC Complete all as specified and as directed by Engr-in-Charge.
Supply only blower motor for window air conditioner of capacity 1.5 /2 ton, type & specification as per existing Complete all as specified and as directed by Engr-in-Charge.
M&L for Window AC front grill complete as per existing for 1.5 Ton Complete all as specified and as directed by Engr-in-Charge.
Supply only evaporating coil for window/split air conditioner of cap 1.5/2 ton capacity, Complete all as specified and as directed by Engr-in-Charge.
Supply only blower/fan motor for outdoor unit of split air conditioner of capacity 1.5/2 ton, specification as per existing complete all as directed by engineer-in-charge
Supply and fixing in replacement of electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
Repair of electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0/2.5 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
Supply only remote control for split/window AC of existing make Complete all as specified and as directed by Engr-in-Charge.
Supply only swing motor, 230 v AC, 4-6 RPM for split/window AC of any make complete all as specfied and as directed.
Supply only fan motor for indoor unit of 1.5/2 Ton split AC Complete all as specified and as directed by Engr-in-Charge.
Supply only water overflow PVC pipe heavy duty on wall/floor of size15mm dia for water drainage.
Supply only copper tubing 6mm to12 mm dia and thickness of copper tubing shall not be less than as per OEM.
Taking out and refixing at another location window type/split type AC 1.5 Ton/2 Ton including making hole in wall required size and making good disturb surface including electrical connection and testing of AC after installation complete all a specified and directed.
M & L in replacement of split Air conditioner outdoor unit wall mounting stand for suitable size of 1.5/2.0 TR split AC including fixing as directed by Engr-in-Charge complete all as specified.
Supply and fix in replacement blower motor for desert cooler 230volts, 1/5 HP , specification as per existing complete all as directed by engineer-in-charge .
Repalcement of old unsv/damage khas-khas pads for three sides, for desert cooler complete all as specified and directed by engineer-in-charge.
Supply and fixing in replacement of old worn out/rusted desert cooler body frame of capacity 4000 Cum/Hr made of 20 gauge PGI sheet suitable for evaporative type desert cooler of size 67x67x87 cm (Approx) including side panel - 03 Nos with 20 gause PGI sheet and water tank height 20 cm & grill with fins electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow PVC pipe connection, including duly painted complete body internally and externally and all side panel inner and outer side with two coat with synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed.
Supply & fixing in repairs side shutter as per existing duly painted complete all as specified and directed by Engineer in Charge
Supply, Fixing in replacement of old unserviceable/damage submersible water pump with new submersible water pump , AC operated, single phase, capacity 1/20 HP, 240 Volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size,complete all as specified and directed by Engr-in-charge.
Supply, Fixing in replacement of old unserviceable/ damage capacitor, 4 Mfd, 50Hz, complete all as specified and as directed by Engineer-In-Charge
S&F in repairs switch piano type 5 Amp, flush type, single pole complete all as specified.
Material and labour for scratching of old paint and rust by wire brush and applying two coats of spray paint of existing colour/ as directed including black bitumen paint at in side body of desert cooler complete all as specified and directed by Engineer-in charge.
Supply & fix fan blades (Steel) for desert cooler in replacement as per sample all as specified.
Supply & fix flexible PVC water pipe of 15 mm dia with water distribution including replacement with PVC Elbows/junction/bend for desert cooler of any size.
Supply & fix in replacement PVC cable flexible round/flat 3 Core Copper conductor cable 4 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
Supply & fix in replacement PVC cable flexible round/flat 3 Core Copper conductor cable 1.5 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
S&F in replacement sheet metal enclosure powder coated versatile double door 2way (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as specified.
Supply & fix 3 pin Plug Top 15 Amp in replacement complete all as specified and directed.
Supply & fix 3 pin Plug Top 5 Amp in replacement Complete all as specified and as directed by Engr-in-Charge.
S&F in replacement MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards Complete all as specified and as directed by Engr-in-Charge.
S&F in replacement MCBs single pole and neutral (SPN) 40 Amps with 10 KA breaking capacity of 'C' series in distribution boards Complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking out of voltage stabilizer of capacity 0.5 KVA to 5.0 KVA single phase 50 HZ detecting and rectifying faults and refixing , the replacement of parts will be paid and measured seperately under relevant items complete all as specified and directed
Dismantling of main transformer/voltage stablizer copper wound 160-250 volt stamping and material & labour for reassembling the stamping re-winding of main transformer single phase 50HZ with supper enameled copper winding wire of correct size tums taping an vanishing of size 0.5 KVA to 2 KVA for PCB relay, resistance bakeilts mounted 2 to 3 pin connection with brass strip, Amp meter (0-30) Amps, Voltmeter(0-30)volts Kit Kat indicator and replacement to flexible wire 3 Core up to 40.0.0075 size round, cooper conductor and plug top 3 pin 5 to 15 Amps and reassembling testing complete all as specified and directed by Engineer-in-Charge
All as per item No 69.00 but for 4 KVA to 5 KVA capacity.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 2/3 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 4 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270/300 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 5 KVA having digital display to show input and output voltage
Supply and fix in replacement push cock and stop cock unserviceable/damage push cock with new push cock, chromium plated, for 15 mm bore pipe internal/external thread, suitable for water cooler of any type and any capacity, complete al as specified and as directed by Engineer-In-Charge.
Taking out old unserviceable gate valve and supply and fix new 15 /20 mm dia bore gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
Supply and fix in replacement GI pipe Medium grade galvanized of 15 mm dia bore size in any lengths laid in trenchs or laid on floors or fixed with walls with all fittings in such as tees, bend, elbows, sockets, reducer , connectors, back nuts, diminishing pieces, caps, plugs, nipples and union complete incl taking down old rusted/unserviceable pipe all as specified and directed.
M&L in replacement of old unserviceable/ damage ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pioe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
M&L for Fabricated from Mild steel angle sections in replacementincluding nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified & directed.
Material and labour for repair/servicing of water purifier , RO system , UF stabilized TDS controller of kent Elite MRO model through authorized service representative and replace the defective components and RO made functional, minor items such as waste pipe,pvc connector,elbow etc shall be deemed to be included in quoted rate.
S&F in replacement membrane suitable for RO kent/Auqa guard.
S&F in replacement candle for sedimentation filter
S&F in replacement candle for pre/ post carbon filter
S&F in replacement booster pump for RO complete all as specified and as directed
S&F in replacement for TDS controller of RO complete all as specfed and as directed.
Material and labor for replacement of unsv split AC indoor unit body, unsv AC junction box, unsv voltage relay , unsv blower fan and motor, burnt swing motor, unsv PCB and Evaporator and replacement of all filter complete make the AC serviceable all as specified and as directed.
Supply and fix in replacement modular single phase motor starter , 250V AC, 25 Amp, 2 module, panel mounting type as per existing make complete all as specifed and as directed.
Material and Labour for replacement of unsv Split AC 1.5 Ton outdoor unit , unsv compressor, unsv fan motor with blade and unsv rusted outer body, and capacitor, unsv condenser replace all the unsv part and make the outdoor unit to serviceable condition complete all as specified and as directed.
Taking down Exhaust Fan of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
S&F in replacement double ball bearing (ISI marked) including necessary greasing at site for exhaust fan of 450mm sweep capacities.
S&F in replacement double ball bearing (ISI marked) including necessary greasing at site for exhaust fan of 300mm sweep capacities.
S&F in replacement Gun metal bush for Exhaust fan of any cap/ any size sweep complete.
M&L for removing old burnt winding of exhaust fan/wall mounted fan of 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
M&L for removing old burnt winding of exhaust fan/Wall mounted fan of 300mm/230mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
S&F in replacement metallic blade suitable for exhuast fan of 450mm/300mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
S&F in replacement metallic louvers shutter suitable for exhuast fan of 450mm/300mm/ 230mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
Taking down Ceiling fan of any make & sweep size by disconnecting clips,lock nuts etc. from existing position of any height,keeping in safe costudy for repair & mainteance. (Note: Repair & Maintance Shall be paid separetly under relevant items.)
Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance with existing down rod clips,lock nuts etc. Note:- (i)Refixing of repaired fan in any location of NAMS area with in distance of 5 Km shall be contractors responsiblility at his own arrangement of transport and tool and plant.(ii) cost of minor items such as hanging clamp,split pin, steel screw,rubber reel etc included in quoted rate.
M&L for rewinding of ceiling fan upto 1200/1400mm sweep AC 230 volt with super enameled copper winding wire with an appropriate gauge and no of turns as originally designed by manufactures with all type of packing /insulating material varnishing including dismantling & reassembling after repair including cleaning and painting of ceiling fan complete with synthetic enamel paint by spraying one coat after rewinding of the same and marking MES number and testing completeall as specified and directed by Engineer incharge.
S&F in replacement bearing for ceiling fan 1200mm/1400mm sweep ISI marked including necessary greasing complete all as specified
S&F in replacement Gun metal bush for ceiling fan 1200mm/1400mm sweep.
S&F in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep
S&F in replacement blade suitable for 1200mm sweep Ceiling fan complete all as directed.
S&F in replacement blade suitable for 1400mm sweep Ceiling fan complete all as directed.
Supply and fixing mounting legs with rubber bush suitable for any type of exhaust fan complete all as specifed.
Supply only celing fan down rod 15 mm bore, 300/400 mm long , factory made, colour brown/ white complete.
S & F in repalcement flexible 2 core copper conductor cable of size 0.75 sqmm wire PVC insulated super conductor twin core for replacement from ceiling rose to ceiling/exhaust fan complete all as specified and directed.
S&F in replacement of capacitor 2.5/2.75 mfd ISI marked complete all as directed.
S&F in replacement of capacitor 3.15 mfd ISI marked complete all as directed.
Taking down and refixing in PVC Exhaust Fan motor in replacement for 230/250 mm sweep, 230 volts 50 c/s of any make complete all as specified and directed.
Taking down and refixing PVC Exhaust Fan blade in replacement for 230mm/250mm sweep 230 volts 50 c/s of any make complete all as specified and directed.
Taking down and refixing PVC Exhaust Fan body in replacement for 230/250mm sweep, 230 volts 50 c/s of make bajaj / Havell,s/Crompton all as specified and directed.
Taking down the startor of celing fan from site and carrying to workshop for remetalling and lathe work of shaft making it to original shape and refixing at exisitng site complete all as specified and directed.
Supply and fixing in reapir/replacement of stepped type electronic fan regulator flush type all as specified and directed.
M&L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm and 1 run of 4 sqmm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down old sub main wiring .
S&F in replacement of 3 pin socket suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed .
S&F in replacement of 3 pin plug suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed .
M/s MAHAJAN CONSTRUCTION CO.
HARPAL ENGINEERS AND BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .