Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC NEW DUDHNOI GOALPARA | BARPETA | ASSAM | 783101 | L1 | Accepted-AOC Awarded as L1 bidder | |
| 2 | L2₹45.5 LSame as L1Rejected-AOC | L2 | Rejected-AOC R | |
| 3 | L3₹50.6 L+₹5.1 L (11.1%)Rejected-AOC C O LT B PATHAK HOMEO COLLEGE ROAD PANJABARI PO PANJABARI PS DISPUR KAMRUP M ASSAM PIN 781037 | GUWAHATI | KAMRUP M | ASSAM | 781037 | L3 | Rejected-AOC R |
Tender Value
₹50.6 L
EMD Value
₹1.0 L
Closing Date
3 Mar 2020, 2:00 pmClosed
CEO, Kamrup Zila Parishad, Panbazar, Guwahati-1
o/o Kamrup Zila Parishad, Panbazar, Guwahati-1
Construction of Citizen Service Centre at Kulhati G.P, Hajo under SPMRM for the year 2017-18, 2018-19 and 2019-20
2020_PNRD_16721_1
KZP(R)T/02/2019-20/38172-80
Open Tender
Civil Works
Works
365 days
Hajo
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,600
C.E.O., Kamrup Zila Parishad
₹1.0 L
Yes
o/o Kamrup Zila Parishd, Guwahati-1
8 Mar 2021
22 Feb 2020
3 Mar 2020
22 Feb 2020
3 Mar 2020
22 Feb 2020
25 Feb 2020
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Extra over item 18.1.1 (a,b,c) for each subsequent floor or part thereof above 1st floor level
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop 1:1:5:3
Extra over itemNos. 2.2.1(I)(B) above for each subsequent floor or part thereof above the 1st floor level b) M20 grade concrete or Prop. 1:1.5:3
Extra over item No.s 2.2.1 (I)(B) above for each subsequent floor or part thereof above the 1st floor level
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: oundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (i) Using 25mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 25mm thick plank
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25mm thick plank
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (ii) Using 25mm thick plank
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Extra for each subsequent floor or part thereof above the first floor level as mentioned in item no. 3.1.1 & 3.1.3(b)
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. a) Brick on flat soiling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4.
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per designas directed and specified. b) with 1st class timber ( Bonsum/Sundi
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately )
Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting (b)Fixed windows and ventilators (iv) 5 mm clear glass
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) etc. complete as directed.
Chequered Terrazo tiles of 22mm thickness with marble chips of sizes upto 6 mm fixed on wall with 10mm thick bed of cement plaster in proportion 1:3 (1 cement : 3 coarse sand) jointed with neat white cement slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete with tiles of any approved shade/shades. a) Using white cement
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a) With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. i) Surfaces over 100mm in width or girth. b)High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed. (ii)Thickness = 1.0mm thick
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii)Thickness = 1.0mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no. 13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICICI paint/ J&N paint/ Nerolac) on ceiling and on sloping roof.
Extra over item no. 13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICICI paint/ J&N paint/ Nerolac) on ceiling and on sloping roof.
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished ) a)Sliding door bolts i) 300 mm x 16 mm
b)Tower bolts i) 300 mm x 12 mm
c) Door handles iii) 150mm
e) Butt hinge ii) 75 mm x 45 mm x 3.20 mm
iii) 100mm (godrej with handle) Morticlock vertical type
Providing , fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50 mm x 60 mm ( Toletance +1 mm ) Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L- Shaped brackets of size 100 mm x 100 mm or plastic brackets of size 75 mm x 75 mm with metred cut at the corners.
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filled with PVC panels of approved colour of size 100mmx20mm. Then two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all complete as specified and directed at all levels. (Door fixtures and fittings to be measured and paid seperately)
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
Providing fixing, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow sec tion conforming to relevant IS code as per approved design and drawings including providing MS cleats base plates, bolts and nuts and one coat of red oxide Zinc Chromate primate primer and two coats of approaved enamels points complete including fitting necessary cleats etc, for fixing ceilling joists as per design and drawing as directed. a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to IS Specification :1161-1998
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Department (d) 0.60 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Department (d) 0.60 mm thick i)150 mm lapping
(FALSE CEILING) Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. (B) Designer Ceilings of Everest make or equivalent as directed by the departement (i) Using 4 mm thick FC Board
(Sanitary installation works) Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (viii) Petite (S/P) (Cat No.C0287/88) (inclusive of seat cover)
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) A) Parryware make (i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (A) Parryware Make (a) White (i) Duke 660 x 495 (Cat. No.C8416/27) (white/coloured)
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (b) Queen's (Cat.No.AQN-7731)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. i)110mmdia
ii)75 mm dia
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
(iii) 90mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (ii) 110mm x 75 mm
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 90 mm x 75 mm
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (iv) 75mm dia. PVC cowel of ISI make
Providing fiting & fixing (300x230)mm C.I. yard gully hinged Grating complete as directed and specified. C.P. Grating (ii) 110mm dia
Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. vii) 50 Users
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Water Supply Works Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reduced, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed on walls d) 25 mm dia (Medium) i) Using Tata make
(B) Concealed by chiselling or breaking brick wall/ CC wall/ R.C.C. wall and making good to the damaged structure. d) 25mm dia (medium) i) Using Tata make
d) 20mm dia (medium) Using Tata make
Supplying fitting and fixing C.P. bib cock 15 mm dia of approaved brand directed and specified. (G.I. & C.P pipes will be measured separately) (i) Essco make (Delux/ Sumthing spl. / Tropical) ( c) Two way long body bid cock with wall flange
Supplying fitting and fixing chrome plated (CP) stop cock of approaved brand and size as mentioned below as directed and specified (G.I. & C.P pipes will be measured and paid separately) vi) Marc brand a) Oriental Series (ii) Concealed stop cock 20mm
Supplying fitting and fixing chrome plated (CP) flush cock of approaved brand as directed and specified (G.I. & C.P pipes will be measured and paid separately) i) Agmeco brand c) Flush cock Concealed
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed In exposed surfaces or in trenches. A) G.I. pipe with GI fittings a) TATA/ SAIL (Medium) iv) 25 mm diameter
iii) 32mm diameter
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department .i) Bore hole of 75 mm dia inter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. 1) 50 mm dia
Supplying fitting and fixing ISI approved PVC filter 3.00Mtr long (ii) 50mm dia
Supplying and plastic cylindrical vertical claused top (PCVC) tank of Sintex/Polycon/Patton make over the staging with manhole cover with locking and cleaning arrangement etc. as directed and specified …… 1) 500 litre capacity b) Polyon make
Labour for erecting and placing PCVC tank over the staging of 5.00 m up to 8.00 complete as directed
M/S KK ASSOCIATES
Sri Dharmeswar Pathak
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .