Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.5 LAccepted-AOC NA | NA | NA | 121004 | L1 | Accepted-AOC lowest | |
| 2 | L2₹68.8 L+₹2.1 L (3.18%)Rejected-AOC | L2 | Rejected-AOC higher | |
| 3 | L3₹69.7 L+₹3.1 L (4.62%)Rejected-AOC | L3 | Rejected-AOC higher | |
| 4 | L4₹71.7 L+₹5.0 L (7.50%)Rejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L4 | Rejected-AOC higher |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
17 Jun 2021, 6:30 pmClosed
Shashi Kant EE
O/o EE PHED Hansi Near Jind Chungi Hansi Pin-125033
Const. of Inlet channel , Washing of Filter Media platefarm, Repair of 3 No. S S Tanks, Repair of boundary wall, Rising main distribution system, CI DF PE Specials, F.H.T.C. supplying erection Pumping Machinery, Electrical Panel board, at Village
2021_HRY_174047_2
SE HSR No.7189 dt.21.05.2021 PHED Hansi
Open Tender
Civil Works
Works
90 days
PHED Hansi
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
₹1.7 L
Yes
21 Jul 2021
12 Jun 2021
17 Jun 2021
12 Jun 2021
17 Jun 2021
12 Jun 2021
Amount
Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum Four (4) star rating duties directly coupled to Ac squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. "A) Clear Water Pump at boosting station 500 LPM, 35 Mtrs. Head 7.50 BHP"
Supply and Fixing following CI D/F pipe and specials/Bell Mouth including cost of joining materials, laying, jointing, refilling inckuding making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the Department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water puping sets at water works in position, as per specification given in schedule No. II. A) CI D/F pipes I. 100 mm i/d
II. 150 mm i/d
B) Bell Mouth b)150 mm i/d
"Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500X1200mm and 400mm deep having following accessories:- 1. Incomer switch 200 Amp. 2. Aluminum bus bar chamber of 300 Amp. Capacity. 3. Volt meter 100X100mm range 0 to 500 V (AE/KAPPA/L & T ) 4. Indicating lamp-one set.
"A)Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm and 400mm deep having following items:-:- A) At boosting station clear water pump sets for 500 LPM x 35M head = 2 Nos. (a) Main switch 100 Amp. 2 Nos.. (L & T Siemens, ABB). (b) Volt meter 100X100 mm range 0 to 500 volt 2 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS & ASS 2 No. each of approved make (f) SPP 2 No. of approved make (g) Motor starter, star delta 2 Nos. for 500 LPM x 35 M Head Motor (L&T Simens, AAB) (h) Capacity KVAR as per site requirement (i) Indicating Lamp-One Set ( j) Change over switch 100 Amp. = 1 No.
Supply, erection, testing of standard make wiring of 2 nos. motors with underground system in PVC and flexible pipes copper wire size 10 Sq mm complete in all respects with accessories like thimble etc. complete in respects.
Supply, erection, testing of standard make wiring of 2 nos. motors with underground system in PVC and flexible pipes copper wire size 4 Sq mm complete in all respects with accessories like thimble etc. complete in respects.
Supply, erection, testing of ISI marked copper wire for 1 Nos. panel boards from main switch to panel and wiring of panel with size 10 Sq. mm copper wire ISI marked complete in all respect with accessories like thimble etc. complete in respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in respects.
Providing and fixing ceiling fan 1400 mm (56") with speed adjuster of reputed make (make Crompton, Usha, Bajaj, Orient) complete in respect..
Providing and fixing exhaust fans 18" i/d (450mm) complete with suitable GI sheet of approved make complete in respects.
Supply erection of "Wall Mounting type, solenoid driven, motor-less, electro-magnetic disphragm Dozing Metering pump working on single -phase 220/240 V. / 50 Hz, electric supply with standerd electronic controls, suitable for minimum dozing capacity 0-5 LPH, at 8 bar back pressur"e complete with necessary accessories. Make Fontus or any other standard make along with supply & erection of supply & erection of 1 No. voltage stablizer with each dozing pump alongwith 1 No. 300 ltrs. capacity ISI marked HDPE storage tank, with each dozing pump of "Sintex" other reputed & approved make.
Supply, erection, testing of reputed make CFL vapour light 100 watts with fitting and accessories complete in respects.
Making Functional House Hold Tap Connection complete in all respect. Providing and fixing in position G.I. Elbow ISI marked. 485 Nos. x 4 = 1940 nos.
Providing and fixing in position G.I. Nipple ISI marked. 485 Nos. x 2 = 970 nos.
Bidder Name
Amount
M/S SAT NARAIN GUPTA CONTRACTOR(GSTN-06ABDFS4734R2ZK)
ANIL KUMAR CONTRACTOR(GSTN-NA)
SURENDER CONT(GSTN-NA)
Mehar Singh Contractor(GSTN-NA)
ANIL KUMAR CONTRACTOR
SURENDER CONT
M/S SAT NARAIN GUPTA CONTRACTOR
M/S SAT NARAIN GUPTA CONTRACTOR
Mehar Singh Contractor
ANIL KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .