Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 50 DASHRATH PURI PALAM DABRI ROAD SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹44.7 L
EMD Value
₹89,405
Closing Date
27 Dec 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer (ED-1), Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Providing Kitchen Ventilation Arrangement in Nilgiri and Girnar Hostel, IIT Delhi
2023_IIT_785258_1
IITD/WORKS (SP-4451)/2023
Open Tender
Miscellaneous Works
Works
60 days
Indian Institute of Technology Delhi
As per tender documents
12 documents required · 12 mandatory
₹0
₹89,405
12 Jan 2024
13 Dec 2023
28 Dec 2023
13 Dec 2023
27 Dec 2023
13 Dec 2023
Amount
FRESH AIR SUPPLY UNIT: Supply, Installation, Testing and Commissioning of DOUBLE SKIN AIR WASHER having specifications as under:- [A] Air filter section comprising 50 mm thick pre air filter made out from washable synthetic fiber with 90 % down to 10 microns. [B] Humidification section comprising of Wet pads 200 mm thick impregnated cellulose paper media. [C] Fan Section comprising of belt driven, 1 nos. forward curved DIDW centrifugal fan [D] Suitable capacity TEFC squirrel cage induction motor, IP55, class 'F' insulation, IE3 Efficiency, suitable for 415 V + 10% volts three phase 50 cycles AC supply ,required with pulley, belt, belt guard etc. [E] The unit shall be fabricated with frame work hollow extruded aluminium profile with 0.6 mm pre-plasticized GSS on outside and 0.6 mm plain GSS on inside complete with 25 mm thick CFC free PUF insulation of minimum 38 kg/cum density sandwiched in between inner and outer skins, SS -304 ( 18 g ) Sump tank, 'B' class GI piping for make up, drain & quick fill connections etc. complete with volume control damper inbuilt [F] 1 no. x 0.5 hp monoblock Pumps of suitable discharge and head (1 Working ) for water circulation [G] all related plumbing accessories such as butterfly valve, gate valve, ball valve, NRV, Y strainers, pipe connections, elbow, union ,Tee, nipple, C section channel for for motor & blower mounting, anti vibration pads etc. [H] all safety devices like safety limit switch , marine light , inspection view glass. Suitably designed for variable frequency drive as well as star-delta applications complete with attached specifications. [Acceptable Make: Zeco / INCLEAN / Waves]
12,800 CFM (Nilgiri Hostel)
12,000 CFM (Girnar Hostel: distribution: 10,000 for kitchen & 2,000 for washing area)
EXHAUST UNIT (DRY SCRUBBER): Supply, Installation, Testing and Commissioning of factory built floor mounted Dry type double skin horizontal / vertical exhaust scrubber unit made of 25 mm thick panels consisting of pre-plasticized G.I. casing of thickness not less than 0.6 mm outside layer and 0.8 mm inside layer with suitable insulation factory injected between them by injection moulding machine, complete with blower section with DIDW backward curved blower suitable for static pressure as required, ESP (Electrostatic Precipitator) Cells comprising ionisation electrode, collection plates, collection trays, suitable number of plates per cell capable of handling CFM as per scrubber design rating, ability to capture particles from 0.01 to 10 micron size, filtration efficiency: 95±2% down to 0.5 micron size particles as per ISHRAE standard, door limit switch, filter sections with aluminium wire mesh type pre and post filters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 230 / 415 ±10% volts, 50 Hz, 1/3 phase ac supply suitably designed for star-delta applications, necessary vibration isolation arrangement etc., Volume contrl damper as applicable complete as per specifications and of following capacities. [Acceptable Make: Zeco / INCLEAN / Waves]
8,000 CFM (Nilgiri Hostel 2 Kitchens)
12,000 CFM (Girnar Hostel Kitchen)
GI DUCTING: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vaney, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (Ducting layout drawing and its design to be got approved by E-in-C before fabrication and erection)
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Exhaust Hood: Supplying, Fabricating & Installation of SS 304 Fabricated 20 SWG Box type Kitchen Exhaust Hood with 24 SWG SS304 Baffle Filters, Oil Tray and Marine Light arrangement having compatibility with the size of the existing oven as per norms etc. complete with connections with the exhaust duct (for wall mounting or island type of hood as applicable) complete as required.
Minor Civil Work: Making Wall Punching, fixing and water proofing for duct entrance and mending good the damages during erection work etc. complete as required. (for two separate places of execution)
Scaffolding Arrangements: Making temporary scaffolding arrangement for fixing of duct and other accessories for height upto 20 metre as required icluding removing the same after completion of erection as required. (for two separate places of execution)
MS Supports: Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm or 50 x 50 x 5 mm, joints mitred and welded by angle iron 35x35x5 mm or 50 x 50 x 5 mm as required or 35x 5 or 50 x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Duct Thermal Insulation: Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required
Supplying and fixing of powder coated extruded aluminium supply air grills with aluminium volume control dampers as per specifications.
Supplying and laying of XLPE / PVC insulated stranded copper conductor 1.1 KV grade [un-armoured] of following size on existing cable tray suitably clamped with termination with copper lugs at both ends as required. (Acceptable make: Polycab / Havells / Gloster / RR Kabel / Finolex / KEI / Universal / Rallison)
3 Core x 2.5 sqmm
4 Core 10 sqmm
GI Tray Support: Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including GI protective sheet covering outside the room as required. (Only for outdoor portion)
225 mm width x 50 mm depth x 1.6 mm thickness
Dismantling the existing old and damaged ducting, other external units including removing the same from existing position etc as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in sheet steel enclosure including drilling holes, duly factory painted as required, making connections, providing spreader terminal, etc. as required. (Acceptable make: Havells / Legrand / L&T / C&S / ABB / Siemens / Schneider) For main power connection.
63 A, 25 kA, FPMCCB
Sub Head - 2 (Comprehensive Maintenance)
Comprehensive maintenance including routine, preventive and breakdown maintenance of the entire ventilation system including routinely cleaning of filters, checking and maintenance of other accessories for smooth running during the defect liability period of 12 months from the date of commissioning of the system. No payment shall be done during DLP.
Comprehensive maintenance including routine, preventive and breakdown maintenance of the entire ventilation system including routinely cleaning of filters, checking and maintenance of other accessories for smooth running during the defect liability period of 12 months from the date of commissioning of the system. Materials / spares required to be replaced or repaired shall be got done by the contractor. No payment shall be done by the Institute. Maintenance to be done as per maintenance schedule. N.B. - Replacement of filters are within the scope of IITD
2nd year (1 Job means for a period of 12 months)
3rd year (1 Job means for a period of 12 months)
4th year (1 Job means for a period of 12 months)
5th year (1 Job means for a period of 12 months)
6th year (1 Job means for a period of 12 months)
(-) Less Credit for dismantled materials (G.I. duct, blower, washer cabinet) N.B.: Reserve price is Rs.10,000.00 (Ten Thousand only). Bidder cannot quote below this amount.
Bharti Refrigeration Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .