Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.7 LAccepted-AOC | L-1 | Accepted-AOC Accept | |
| 2 | L-2₹6.0 L+₹33,189.86 (5.86%)Rejected-AOC KANPUR NAGAR | UTTAR PRADESH | 209402 | L-2 | Rejected-AOC Reject | |
| 3 | L-3₹6.2 L+₹55,008.06 (9.70%)Rejected-AOC | L-3 | Rejected-AOC Reject |
Tender Value
₹5.7 L
EMD Value
₹6,000
Closing Date
23 Nov 2024, 1:00 pmClosed
SE EDC-1 AGRA
B-690 Kamla Nagar Agra
For the work of Overhauling, Replacement of Packaging and Other associated works on 05/08/10 MVA Power T/Fs situated at Various S/s under EDD-1 Agra.
2024_DVVNL_973361_2
37/EDCA/2024-25
Open Tender
Electrical Works
Piece-work
60 days
B-690 Kamla Nagar Agra
As Per Tender Documents
2 documents required · 2 mandatory
₹1,180
DVVNL
₹6,000
1 Feb 2025
17 Nov 2024
23 Nov 2024
17 Nov 2024
23 Nov 2024
17 Nov 2024
05 MVA T/F at 33/11 KV S/s Digner & Kabees.
Opening of all connection of 05 MVA Power Transformers as per direction of superivising Engineer
Drain out of Transformer oil for replacment of damaged packing of 5 MVA Powre Transformer.
Opening of 33 KV, 11 KV bushing rod very carefully and removal of damaged packing and replacment of packing and fixing of 33 KV, 11 KV bushing rod complete.
Replacment of Damaged Inspection cover packing with new Packing and fixing.
Replacment of LT side Rod 2 No (required material provided by contrator at his own cost)
Radiator air release and Balb Seal Replacement.
Opening of radiator and removal of damaged packing, fixing packing of radiator and fitting of radiator of 5 MVA Transformer by the help of crain and as per direction of superivising Engineer.
Equalizer pipe (Remove damage packing and Dry foum fixing New packing)
Replacment of Oil Lable gaze damaged glass and packing (required material provided by contrator at his own cost)
Filling of Transformer Oil in the power Transfomer after replacment of all required packing as per direction of supervising Engineer.
Making of all connection of 5 MVA T/F.
Cleaning of 5 MVA Power T/F by the caustic soda for removal of dust/oily surface.
All packing set complete for 5 MVA Power T/F made of cork sheet. (required material provided by contrator at his own cost)
08 MVA T/F at 33/11 KV S/s Sikandra.
Opening of all connection of 08 MVA Power Transformers as per direction of superivising Engineer
Drain out of Transformer oil for replacment of damaged packing of 08MVA Powre Transformer.
Opening of 33 KV, 11 KV bushing rod very carefully and removal of damaged packing and replacment of packing and fixing of 33 KV, 11 KV bushing rod complete.
Replacment of Tap Changer Packing as per direction of suepervising Engineer.
Radiator air release and Balb Seal Replacement.
Opening of conservator tank by the help of Crain removal of damaged packing, cleaning of surface fixing of packing and fitting of conservator tank.
Opening of radiator and removal of damaged packing, fixing packing of radiator and fitting of radiator of 5 MVA Transformer by the help of crain and as per direction of superivising Engineer.
Equalizer pipe (Remove damage packing and Dry foum fixing New packing)
Replacment of Oil Lable gaze damaged glass and packing (required material provided by contrator at his own cost)
Filling of Transformer Oil in the power Transfomer after replacment of all required packing as per direction of supervising Engineer.
Replacement of C Phase Bushing Packing Lt Side
Making of all connection of 8 MVA T/F.
Replacment of Silica Gel 03 Kg.
All packing set complete for 8 MVA Power T/F made of cork sheet. (required material provided by contrator at his own cost)
10 MVA T/F at 33/11 KV S/s Kabees .
Opening of all connection of 10 MVA Power Transformers as per direction of superivising Engineer
Drain out of Transformer oil for replacment of damaged packing of 08MVA Powre Transformer.
Opening of 33 KV, 11 KV bushing rod very carefully and removal of damaged packing and replacment of packing and fixing of 33 KV, 11 KV bushing rod complete.
Replacment of Damaged Inspection cover packing with new Packing and fixing.
Radiator air release and Balb Seal Replacement.
Opening of radiator and removal of damaged packing, fixing packing of radiator and fitting of radiator of 5 MVA Transformer by the help of crain and as per direction of superivising Engineer.
Equalizer pipe (Remove damage packing and Dry foum fixing New packing)
Replacment of Oil Lable gaze damaged glass and packing (required material provided by contrator at his own cost)
Filling of Transformer Oil in the power Transfomer after replacment of all required packing as per direction of supervising Engineer.
Making of all connection of 10 MVA T/F.
Replacment of New Silica Gel Breather help by Labour. (required material provided by contrator at his own cost)
All packing set complete for 10 MVA Power T/F made of cork sheet. (required material provided by contrator at his own cost)
Cleaning of 10 MVA Power T/F by the caustic soda for removal of dust/oily surface.
Sen Enterprises (BID ID -4738971)
M/s. Siddhi Vinayak Enterprises, Agra (BID ID -4738977)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .