Ex. Engineer (Elect)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, Keshav Chowk, Delhi-110053
Construction of Mini Stadium at Tikona Park New Zafrabad in AC-67 Shahdara (North) Zone Sub Head Provision of Electrical Installation and Fans
2022_EDMC_138187_1
EE(E)-I/SHN/MCD/22-23/TC-22/4
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹15,100
4 Jan 2023
14 Dec 2022
21 Dec 2022
14 Dec 2022
20 Dec 2022
14 Dec 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular type switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.. Group C
Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2x2.5 sqmm + 1x2.5 sqmm earth wire
(b)2x6 sqmm + 1x6 sqmm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. (a) 5/6 amps switch
(b) 3 pin 5/6 amp socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing anf fixing 6 pin 5/6 and 15/16 A modular socket outlet and 15/16 A modular switch connections etc as required.
Supplying and fixing following way, single pole and neutral , sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way, Double door
supplying and fixing single pole blanking plate in the existing MCB Db complete etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
Supply and fixing 25A rating double pole,(single phaseand neutral) 240 volts, residual current circuit breaker(RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connection testing and commissioning etc as required.(40 amp)
supply and fixing of 400mm single phase swing wall fan as reqd.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubical panel making connection etc as requireddisconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N
Layng and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 Kv grade of following size on wall surface as required. Upto 35 sq mm(clamped with 1 mm thick saddle )
Supply of 12"(300 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter , blade etc as requird
Installation of exhaust fan in the existing opening, including making good the damage, connection testing, commissioning etc as required.(upto 450 mm sweep)
"SITC of 60w LED street Light luminiare fitted with lens, madeof pressure die cast aluminum housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage = 60 watt+/-5% (c) Total Lumens output>=15000 lumens (d) Luminaire Efficacy>=100 Lm/w (e) power factor>=.95 (f) Protection Class-IP-66
"SITC of 60w LED Flood Light luminiare fitted with lens, made of pressure die cast aluminum housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage = 60 watt+/-5% (c) Total Lumens output>=15000 lumens (d) Luminaire Efficacy>=100 Lm/w (e) power factor>=.95 (f) Protection Class-IP-66
P&F Hot press sheet moulded compound (SMC) fire retardnt(Temp. resistant upto 200 C), IP 55 weather proof pole box of inner dimension 200x150x100mm(NS) complete with arrangement for fixing of 1 nos of 6 to 32 amp single pole MCB & (MCB/Isolator excluded) with neutral link duty shorting on DIN channel with 2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc s reqd.
SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Watt b) Luminaries effucacy ≥ 100 lumens/watt c) Power factor ≥ 0.95
S/F installation of cubical panal board 16 SWG sheet M.S. depth 30 cm to 60 cm with Al. bus bar and interconection suitable for switch gears i/c and making foundation etc as required
SITC of 150W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage =150 watt +/- 5% (d) Luminaire Efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class- IP-66
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sq. mm
Supply and f of XLPE insulated and PVC Sheathed Al conductor armoured cables for working voltage upto 1.1kv conforming to IS7098 (Part-I) /1998 as required. .a 2x10sqmm
b) 2x6 sqmm
Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 5 mtr pole.
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal)size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing & laying earth connection from earth electrode with 6SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply, Installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 H.P rating Submersible P/Set.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .