THE PROJECT DIRECTOR
THE PROJECT DIRECTOR, DRDA, COIMBATORE
Construction of Solid Block and Paver block Manufacuring unit at S.F.No.125/3 Vinitha Shree Township, Nehru College Road at Malumichampatty in Madukkarai Block of CBE Dist. under Nationall Rurban Mission (Pkg No.05/ NRuM/PHASE I 2016-17 to 2018-19)
2022_RDTN_228296_1
Roc.No.187/2022/INPR/CBE Dt.05.04.2022
Open Tender
Civil Works - Buildings
Item Rate
180 days
Madukkarai Block
Refer Tender Documents
5 documents required · 5 mandatory
₹0
₹40,000
3 Mar 2023
6 Apr 2022
19 Apr 2022
6 Apr 2022
19 Apr 2022
6 Apr 2022
90 days
Amount
1. Construction of Production Shed (Production area, Office, Cement Godown, Water Sump and Open Yard)
Earth work excavation and depositing on bank with initial lead and lift in hard gravelly soil, hard stiff clay, black cotton soil, hard red earth,shales, murram, and earth muds with 50% fair sized boulders as per SS 20B for narrow foundation.
Cement Concrete 1:4:8 mix using 40mm metal including cost and conveyanceof all materials to work site and all labour charges etc.
Brick work in cement mortar 1:5 mix using country bricks 83/4"x41/4"x23/4" and conveyance of all materials to site and all labour charges etc complete
Supplying and erecting centering for sides and soffits including supports for all reinforced cement concrete works all floors etc., complete as directed by the departmental officers complying with relevant standard specifications
Below GL
Column
Roof Slab, Lintel
Cement concrete 1:3:6 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete for 10 the departmental officers
Supply and fabrication of steel including cost and conveyance and all labour charges etc. complete.
Reinforced Cement concrete 1:1½:3 (One of cement, one and a half of sand and three of hard broken granite stones ) using 20mm gauge hard broken granite stones for all reinforced cement concrete works excluding the cost and fabrication of reinforcement grills in position, shuttering, centering but including laying, vibrating, curing, finishing and providing Mild steel fan hooks in the RCC slab wherever necessary as directed by the departmental officers etc., complete in all respects
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .
Cement concrete 1:2:4 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete for 10 the departmental officers
Plastering with cement Mortar 1:5 12mm thick in all floors including curing etc., complete complying with standard specification and as directed.rials and labour charges etc.,
Painting the walls and ceiling two coats with approved exterior emulsion paint over one coat of priming coat of emulsion including cost and conveyance of all materials to site, through scrapping of old plastered surface, preparing the surface, curing etc., complete in all respects (S.I. No. 359B)
Paving the floor with best quality Vetrified ( Such as Morbonite) Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.
Fabrication, Supply and erection of Steel Structures as per the specification, dimensions and design requirement including all labour charges and other charges etc. complete (including Primary and Secondary framing, foundation bolts, Stiffener plate, Cleat plate, fasteners, cold formed Purlin members, MS angle, Rectangular Hollow sections, Sag rods, Bracing rods, End plate, Base plate, Connection plate etc using welding)
Providing square hollow section of size 80mmx80mmx3.5mm
Providing rectangular hollow section of size 80mmx40mmx3.5mm
Providing MS circular hollow section of size 150mm dia. and 4mm thick
Providing rectangular hollow section of size 60mmx40mmx3.5mm
Supplying of colour coated galvanised sheet for roofing including cost and coveyance of materials
For Water Supply
Supply and delivery of PVC rigid pipes for potable water supply with ISI 4985 / 2000 marking with necessary couplers (or) bell ended pipes as specified in ISI, the required quantity of solvent cement and having the following working pressure. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges upto stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid separately) and as directed by the TWAD Board Officers. - 75 MM PVC 6 KSC PIPE
65mm GI Pipe
Earth work excavation and depositng on bank within an initial lead of 10 m and initial lift 0 to 2 m in Hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders for laying pipeline in respect of following size of pipe with standard trench width and required depth including shoring, struting, balling out water wherever necessary and all other incidental works such as barricading, providing danger lights, labour for watch and ward,as oer standard specifications and as directed by the TWAD Board officers. 75 MM PVC 6 KSC PIPE
Lowering PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste as per standard specifications and as directed by the TWAD Board Officers. 75 MM PVC 6 KSC PIPE
65mm GI Pipe
Refilling with excavated earth (other than sand) in respect of following sizes of pipes watered well rammed and consolidated etc. complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested and as directed by the TWAD Board Officers. 75 MM PVC 6 KSC PIPE
Supplying and fixing of Man hole cover 600*600
Toilet (Sub Estimate)
Earth work excavation for foundation in all soils and sub soils to full depth etc., ordinary soil complete
Cement concrete 1:4:8 mix using 40mm iss HBG metal for foundation & flooring including labour charges etc., complete
Random Rubble Masonry in CM 1:5 mix using rough stone and bond stone with simaltanious pointing with same mortor incl. cost, conveyance of materials and all lobour charges etc complete
Brick work in cm 1:5 mix for foundation and basement using rough stone and bond stones with simultaneous pointing with same morter etc., completed
Supplying and erecting steel centering for plane surfaces in foundation and basement for staircase steps column footings plinth beam grade beam etc.,
Supplying and Fabricating and placing in position MS steel or Ribbed Tor Steel for all Reinforced Cement Concrete works as per the design given including cost of steel and binding wire in all floors etc, Complete complying with stanard specification.(MS
Reinforced Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcement and fabricating charges, centering and shuttering but including curing and providing fixtures like fan clamps in the RCC floor or roof slabs
Paving the flooring with special type of flooring tiles (Cement based Hydraulically pressed Anti skid tiles (20mm thick) in CM 1:3, 20mm thick
Dadooing of walls with Printed design glazed tiles of size 30 cm x20cmx6mm laid in CM 1:2, 10mm thick & pointing with white cement using 0.4kg/cm2 -10Sqm.
Plastering with cement Morter 1:5 12mm thick in all floors including curing etc., complete complying with standard specification and as directed.rials and labour charges etc.,
Supplying and fixing in Position Indian Water closet(Oriya type) incluidng all cost
White washing two coats using best freshly burnt shell lime including cost and conveyance of materials and labour charges etc complete.
Colour washing two coats using approved colour pigments including cost and conveyance of all materials to site and all labour charges etc complete
Painting new iron works such as steel doors, Window, Ventilators,Window bars ,Balustrdes etc., with best approved first quality of synthetic enamel paint of approved colour over the existing priming coat etc., complete complying with standard specifications etc.,
Provision for Electricity Arrangements
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains SD-70
Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit SD-127
Supply and run of 4 of 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V gradeon 7 / 20 GI bearer wire for service connection mains - SD.67
Supply and fixing of 8 way SP DB of 16A / way with 32A DP switch with metal clad of 500V with fuse and neutral (side handle) on suitable angle iron frame work with trunking box MS cable entry box with PWD earthing SD No.159
32 Amps TPN Metal Clad Switch with Re-wirable Fuse Units
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) SD 16
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point- SD -38.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) SD 16
Led Outdoor Fittings (Light Emitting Diode) 48W LED Street Light Fitting with LED
Supply and fixing of WT bulk head fitting with guard suitable for incandescent lamp with 60W bulb - SD. 84
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting SD. 88
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18"). SD-106
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
SRISAIHARI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .