Tender Value
₹17.3 L
EMD Value
₹34,503
Closing Date
19 Dec 2020, 6:00 pmClosed
Asstt.General Manager (Engg.-Elect.)
Airports Authority of India,Room No.202/15, ATS Complex, Sutar Pakhadi Road, Andheri (East), Mumbai - 400099
Annual Comprehensive Maintenance Contract of Ductable Package Units, Split / Window A.C. units, Water Coolers, Water Purifiers at ATS Complex, Mumbai for the year 2021 to 2022.
2020_AAI_64225_1
MUM/ATS/ENGG-E/eNIT-08/2020-21
Open Tender
Electrical Works
Item Rate
730 days
ATS Complex, Mumbai
Tender Fee,EMD,MSME Regn.with Decl.,Unconditional Accept.Ltr.,PAN,GST,EPF and ESIC,Undertaking for GST,Details of T and P,Decl. reg.Blacklist./ Debarment,Affidavit for Min.Wages,Work Exp.,Net Worth Cert. and Remaining Docs. as per PQ performa
2 documents required · 2 mandatory
₹1,120
Yes
₹34,503
Yes
4 Feb 2021
10 Dec 2020
21 Dec 2020
11 Dec 2020
19 Dec 2020
11 Dec 2020
11 Dec 2020 - 16 Dec 2020
Amount
Annual Comprehensive Maintenance of 11.6 TR Ductable split Air-conditioners of M/s. Carrier make located at ATS Complex including providing all necessary consumables and spares including replacement of faulty compressor, suitable refrigerant gas charging as & when required basis, fault rectification, repairing/replacement of all other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing , etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual Comprehensive Maintenance of 11.6 TR Ductable split Air-conditioners of M/s. Carrier make located at ATS Complex including providing all necessary consumables and spares including replacement of faulty compressor, suitable refrigerant gas charging as & when required basis, fault rectification, repairing/replacement of all other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing , etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual Comprehensive Maintenance of 8.5/8.0 TR Ductable split Air-conditioners (inverter type or conventional type) of M/s. Carrier/Blue star make located at ATS Complex including providing all necessary consumables and spares including replacement of faulty compressor, suitable refrigerant gas charging as & when required basis, fault rectification, repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual Comprehensive Maintenance of 8.5/8.0 TR Ductable split Air-conditioners (inverter type or conventional type) of M/s. Carrier/Blue star make located at ATS Complex including providing all necessary consumables and spares including replacement of faulty compressor, suitable refrigerant gas charging as & when required basis, fault rectification, repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 4.0 TR (inverter type) Cassette type air conditioners of M/s Blue Star / LG/Carrier, etc. make located at ATS building excluding compressor, Excluding compressor (compressor is under warranty), necessary co-ordination with OEM or its authorized service partner for replacement of the compressor, transportation of the compressor and other related works included in the scope of work. repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, other required consumables, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 4.0 TR (inverter type) Cassette type air conditioners of M/s Blue Star / LG/Carrier, etc. make located at ATS building excluding compressor, Excluding compressor (compressor is under warranty), necessary co-ordination with OEM or its authorized service partner for replacement of the compressor, transportation of the compressor and other related works included in the scope of work. repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, other required consumables, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 4.0 TR Cassette type air conditioners of M/s Blue Star / LG/Carrier, etc. make located at ATS building, including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification, including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 4.0 TR Cassette type air conditioners of M/s Blue Star / LG/Carrier, etc. make located at ATS building, including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification, including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 3.0 TR and 3.5 TR Mega split/High wall/Tower type/Verticool air conditioners of M/s. Blue Star / Voltas / LG /Carrier, etc. make located at ATS building including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 3.0 TR and 3.5 TR Mega split/High wall/Tower type/Verticool air conditioners of M/s. Blue Star / Voltas / LG /Carrier, etc. make located at ATS building including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split type air conditioners (inverter type) of M/s Amtrex/Voltas/Carrier/Blue star/LG make at different locations. Excluding compressor (compressor is under warranty), necessary co-ordination with OEM or its authorized service partner for replacement of the compressor, transportation of the compressor and other related works included in the scope of work. repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, other required consumables, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split type air conditioners (inverter type) of M/s Amtrex/Voltas/Carrier/Blue star/LG make at different locations. Excluding compressor (compressor is under warranty), necessary co-ordination with OEM or its authorized service partner for replacement of the compressor, transportation of the compressor and other related works included in the scope of work. repairing/replacement of other spare parts including timer, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, other required consumables, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split type air conditioners of M/s Voltas/Carrier/Blue star/LG, etc. make at different locations including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 1.5 TR and 2.0 TR split type air conditioners of M/s Voltas/Carrier/Blue star/LG, etc. make at different locations including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual comprehensive maintenance of 1.5 TR Window type air conditioners of M/s Blue Star / voltas make located at ATS building including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required.(Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual comprehensive maintenance of 1.5 TR Window type air conditioners of M/s Blue Star / voltas make located at ATS building including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out the routine- preventive & breakdown maintenance, monthly servicing, fault rectification including suitable refrigerant gas charging as & when required basis, labour charges, etc. as per special conditions complete as required.(Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual Comprehensive Maintenance of 40/80 Ltrs./Hr. Water Coolers having following cooling / storage capacity (Ltrs./Hr.) of Blue star / Voltas make at different locations including providing and fixing all necessary consumables and spares and replacing faulty compressor, fault rectification including suitable refrigerant gas charging as & when required basis, carrying out the routine- preventive & breakdown maintenance, monthly servicing, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) a) First year
Annual Comprehensive Maintenance of 40/80 Ltrs./Hr. Water Coolers having following cooling / storage capacity (Ltrs./Hr.) of Blue star / Voltas make at different locations including providing and fixing all necessary consumables and spares and replacing faulty compressor, fault rectification including suitable refrigerant gas charging as & when required basis, carrying out the routine- preventive & breakdown maintenance, monthly servicing, labour charges, etc. as per special conditions complete as required. (Work includes: maintaining the service card for each equipment at site as per the direction of Engineer In charge & deployment of the maintenance manpower as per the special condition of the contract) b) Second year
Annual Comprehensive maintenance of water purifier of M/s. Eureka Forbes, Model No. Aquaguard Classic HI - FLO at different locations including providing and fixing all necessary consumables and spares as and when required and replacing pre-filter candle and active carbon granules at twice in a year, carrying out the routine- preventive & breakdown maintenance, monthly servicing, etc. as required. Work to be carried out through OEM or its authorities service partner only. (maintaining the service card for each equipment at site as per the direction of Engineer In charge) a) First year
Annual Comprehensive maintenance of water purifier of M/s. Eureka Forbes, Model No. Aquaguard Classic HI - FLO at different locations including providing and fixing all necessary consumables and spares as and when required and replacing pre-filter candle and active carbon granules at twice in a year, carrying out the routine- preventive & breakdown maintenance, monthly servicing, etc. as required. Work to be carried out through OEM or its authorities service partner only. (maintaining the service card for each equipment at site as per the direction of Engineer In charge) b) Second year
Dismantling of Existing Split A.C/Window A.C/Tower A.C/ Water Cooler of Different rating / capacity up to 4 TR. From existing site including dismantling of stand, timer & other associated accessories, etc., refilling existing holes, plastering, finishing the walls, shifting of the Removed Air-conditioning unit along with the accessories up to store room as per the direction of engineer Incharge and as per site requirement.
Installation testing and commissioning of Split A.C/Window A.C/Tower A.C/Water Cooler of different rating / capacity up to 4 TR. including making holes, plastering, refrigerant gas charging, including 6 sq.mm. copper power input cable from nearest power outlet, testing & commissioning, etc. as per site requirement and as per the direction of the engineer in charge.
Supply and installation of copper refrigerant pipe ( 1/2" + 1/4" ) complete with fitting suction line, discharge line with 12 mm. thick nitrile rubber insulation along with suitable size Copper multicore flexible cable (as per OEM recommendation & standard practice) between indoor unit & outdoor unit , brazing including providing of clamps, testing & commissioning, etc. complete as required for 1.5 TR split AC.
Supply and installation of copper refrigerant pipe ( 5/8" + 3/8" ) complete with fitting suction line, discharge line with 12 mm. thick nitrile rubber along with suitable size Copper multicore flexible cable (as per OEM recommendation & standard practice) insulation, brazing including providing of clamps, etc. complete as required for 2.0 TR split / 3.0 TR Mega split AC.
Supply and installation of rigid PVC/flexible drain pipe of 25 mm. dia. with 6 mm. heatlon insulation complete with fittings & Accessories, U straps, etc.
Providing and fixing 12 mm. nitrile rubber insulation on the suction and discharge line of the existing split air conditioners as required.
CHAITANYA SERVICES
S N COOL
New National Airconditioning Co
SNOWMEX ENGINEERS LIMITED
PAN POLAR ENGINEERS PVT. LTD.
Anshutech Airconditioning Pvt Ltd
Manish Electricals
KAILAS REFRIGERATION WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .