| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC | ₹33.4 L Quoted ₹35.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹36.0 L+₹1.1 L (3.05%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹36.0 L+₹1.1 L (3.05%) | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹43.5 L+₹8.6 L (24.5%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹43.5 L+₹8.6 L (24.5%) | L3 | Rejected-Finance Rejected due to highest rate quoted |
| 4 | L4₹45.8 L+₹10.8 L (30.9%)Rejected-Finance | ₹45.8 L+₹10.8 L (30.9%) | L4 | Rejected-Finance Rejected due to highest rate quoted |
| 5 | L5₹45.9 L+₹10.9 L (31.3%)Rejected-Finance | ₹45.9 L+₹10.9 L (31.3%) | L5 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
12 Mar 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
COMPREHENSIVE MAINT OF HVAC INCL VRV PAC WATER CHILLER AND UPS AT NCN REPAIR MAINT OF SPLIT WINDOW AC COOLING APPLIANCES PAC AC PLANT 3 X 7.5 TR CAPACITY AND OTHER ALLIED WKS AND REPAIR OF SOLAR WATER HEATERS AND FIRE FITTING SYSTEM AT AFSSR UNDER GE
2024_MES_643323_1
GE/GUR-/NIT-80/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹91,000
29 Mar 2024
20 Feb 2024
14 Mar 2024
20 Feb 2024
12 Mar 2024
5 Mar 2024
Amount
Material and labour for taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning/washing of cocling coil air Each job filters/plasma filters etc of Indoor unit & condenser, compressors, fan motor etc of Out door unit with vacuum cleaner OR cleaning solution Including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit, fan. blower, etc and changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition complete all as specified and as directed. Note:-(1) Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of new spares shall deemed to be included in unit rate quoted. (ii) Penalty will be charged for not attencing complaint from 6 hours to 12 hours Rs. 250/- and from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency at risk and cost of the contractor.
Supply only following spare parts of split AC unit of cap 1.5Ton/2 Ton complete all as specified and as directed:-
Running capacitor 36 MFD Make: Bentex/Delcon
Running capacitor 45 MFD Make: Bentex/Delcon
Starting capacitor 100-120 MFD Make:- Bentex/Delcon.
Starting capacitor 120-150 MFD Make:- Bentex/Delcon.
Starting Relay 1022/ 1622 Make::- Renutral / Epcas/Asian
Starting Relay 2000 Make:- Renutral/Epcos/Asian
Overload Relay Make:- Renutral/Epcos/Asian
Thermostat switch 2059/2064/2054 Make:- Indfass/Danfoss fan blade for spilt Type A.C Cap 2/1.5 Ton
Condenser fan blade for spilt Type A.C Cap 2/1.5 Ton
Wiring kit for A.C split Type 1.5/2 TR
Remote control for split AC Cap 1.5/2 TR of make as per site requirement complete all as specified and as directed.
Supply & fixing in repairs main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2 TR complete all as specified and as directed.
S & F in replacement suction and discharge valve set for Split AC 1.5/2 TR capacity of make as per exisiting at site complete all as specified and as directed.
Replacement of unserviceable PCBs from existing split type AC of 1.5/2TR capacity, and re-fixing with new proper functioning of the AC complete all as specified and as directed.
M&L for disconnecting from mains and taking out existing unserviceable sealed compressor unit from the sp it type Air Conditioner of Cap Eas 1.5 Ton of any model/make/type from any location and Supply, Installing and testing (in repairs) existing company made new sealed compressors with one year warantee including cleaning and rernoving dust/dirt from the cooling coll condenser coil with necessary modification capillary tube etc including Charging of Gas R-22 and commisioning complete all as specified and as directed. Make Kirloskar/Voltas/Blue star.
All as per item No. 03 above but spilt type Air Conditioner of Cap. 2 Ton Make Kirloskar/Voltas/Blue star.
M&L for Disconnecting from mains and Taking of unserviceable fan motor blower motor of split tyce AC 152 ton capacity of any make and type Em from any location and supply, installing and testing new motor of 1/4 HP or 1/2HP 920 RPM, 230 Volts or as per existing capacity and model complete all as specified and as directed. Make: AUE/Crompton Greaves Speed King/Cool Master Note Transportation Charges From side to trade workst op and back to criginal location after repair shall be deemed to be included in unit rate quoted.
Material and labour for disconnecting from mains and taking out unserviceable condenser couper coil of split Type AC of Cap 15 Ton/2 Ton Ea of any make and type from any location and supply, installing and testing in repairs new condneser coil as par existing capacity and make complete all as specified and as directed.
S & F in repairs evaporator/cooling coil of split type AC of capacity 1.5 TR 12 TR of existing make and size complete all as specified and as directed.
Maternal and labour for taking down unserviceable outdoor unit of split AC of any make type any capacity & supply & fixing nevi outdoor unit E suitable for 1.5/2TR capacity complete all as specified and as directed.
Taking down unservice sble indoor unit of split AC of an, make type and capacity & supply & fixing new indoor unit suitable for 1.5/2TR E capacity complete all as specified and as directed. Maks LG//Voitas/Cam.pro/Godrej
Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipa refrigerant tubing 1/4" for suction /discharge includ ng insulation tubing 1/4" complete including brazing, welding, with bolts and screws c' reqd size complete all as specified and as directed.
Taking down unserviceable copper pipe of size 1/2" and supply & fixing new copper pipe refngerant tubing 1/2" for suction/discharge includ ng insulation tubing 1/2 complete including orazing, welding, with boils and screws of read size complete all as specified and as directed.
Material and labour for taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC complete all as specified and as directed.
Material & labour for detecting the leakages of gas of split type AC of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or charging of refrigerant gas R-22/R-134A in window type /Split Type AC unit of capacity 1.5/2TR including testing and commissioning complete in satisfactory working condrion by any other means and making it fully functional complete all as specified and as directed.
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 15 to 2.0 TR complete all as specified and as directed.
Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20-32 Amps including taking down old/unsv Metal clad socket complete all as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 40 Amps 13 KA complete including taking old unservicable MCBs of any type/capacity complete all as specified and as directed.
Supply & Fixing in replacement Metal clad Plug ISI Marked complete all as specified and as directed.
Supply & Fixing in replacement Metal clad Socket complete all as specified and as directed.
M&L for shifting of split AC 1.5/2 00 TR including dismantling all accessories, indoor outdoor unit and copper insulation, voltige stabiliser and ninstalling the all acessories at new location as directed the coat of new copper pipe suction and discharge including insulation and electr: cable 3 core 4 Sqmum as per site requirement in included in the quoted rate complete all as specified and as directed.
M&L for 3 core flexible PVC ensu ated cord sheathed 4.00 Sqmm including connection complete all as specified and as directed.
M&L for taking down for servicing unserviceable voltage stabilizer of capacity 4 to 5 KVA from the site and transporting to E contractors workshop for locating the fault including checking the servicibility of electrical electronic circuits relays and repalcement of defective spare parts, vassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to site complete all as specified and as directed. Note: Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under.
Supply only following defective spare parts of Voltage stabilizer of Cap 4 to 5 KVA complete all as specified and as directed:-
Voltmeter (Anlog) 0 to 330 voits any type shape single phase 50 Hz AC supply.
Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply.
Printe circuit control card suitable for 4 to 5 KVA.
Nput/cutput switch Maka AE/Rishabh/Mico.
Push on switch Make AE/Rishabh Mico.
Indicator complete with bulbs Make Renutrol/Technomac .
Trigger Transformer for 4 to 5 KVA.
Relay for4 to 5 KVA voltage stabilizer Make Renutral/Technomac.
Time relay .
Material and labour for taking out the burnt winding of transformer of voltage stablizer and prepaining core after cleaning by suitable cleaning agent and rewinding the transofmer of voltage stablizer with super anameld copper wire of existing gauge including varnishing, heating complete all as specified and as directed.
All as per item No 23 above but 5 KVA complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 190 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 300/310 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 40/80 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 60/120 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 150 Lirs capacity rafrigerators complete all as specified and as directed. Note FOR ITEM No. 25 to 29 here as above:- (1) Warranty certificate from manufacturer/authorised dealers shall be submitted alongwith compressor unit. ( Supply and charging of gas will be measured and paid separately under relevant item.
Supply and charging religerant cas non CFC based compatible to F-22/134 in refngerators of capacity 180/300/310 Ltrs capacity complete all as specified and as directed.
Supply and charging refrigerant gas nox CFC based compatible to F-22/134 in water coolers of capacity 40/80 Lirs capacity including 4 cutting and brazing of copper tubes complete all as specified and as directed.
Supply and charging refrigerant gas non CFC bared compatible to F-22/134 in water coolers of capacity froin 60/120 Lims to 150/150 Lis capacity including cutting and brazing of copper tubes complete all as specified and as directed.
Supply and fix in replacement capilary tube of existing size including necessary brazing suitable for 180/315 Lins capacity refrigerator complete all as specified and as directed.
Supply and fix in replacement over load protector relay su table for 180/300/310 Ltrs capacity refigerator complete all as specified and as directed.
Supply and fix in replaciment thermostat suitable for 180/100/310 Lirs cap waty refrigerators complete all as specified and as directed.
Supply and fix ir replacement over load protector relay su able for 40/80 Les capacity water cooler complete all as specified and as directed.
Supply and fix in replacement the mostat suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix irreplacement condensor motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement new condensor motor 1/32 HP with fan blades complete suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement PVC drain pipe 25mm da with suitable standard clip complete to fix with water cooler of any capacity including dismantling the old unserviceable one complete all as specified and as directed.
Supply and fix in replacement PVC connecting pipe 20mrt dia and 1.5 Mtr length for inlet to water cooler with both side threaced sockated type complete all as specified and as directed.
Supply and fox in replacement drain water tray compite suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement chromium plated bib cock push type outer/innar threaded suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in repairs PVC float valve of size 15mm dia complete su able for socke: of same size complete all as specified and as directed.
Supply and fix in repains freezer door with spring of refreginrators of any capacity & make complete all as specified and as directed.
Supply and foxing in replacement vegetable basket with glass suitable for 183/300/310 Ltrs capacity refrigerators complete all as specified and as directed.
Supply and fixing in replacement PVC defrost tray as per sample suitable c 180/300/310 Ltris capacity refrigerators complete all as specified and as directed.
Supply and fixing in replacement door gasket for refrigerators of capacity upto 180 to 310 Ltra complete all as specified and as directed.
Dismantling of existing repairable deep freezers of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop fro carrying out repairs and renewal/replacement of parts, re-assembling and transporting back to the site includ ng installation of the same on the same location and making electric connection etc, complete all as specified and as directed. Note: Parts renewed shall be measured and paid separately under appropriate iterns.
Supply only starting relay upto 300/320 Lirs capacity deep freezer complete all as specified and as directed.
Supply only overload protector suitable for upto 300 Ltrs capacity deep freezer complete all as specified and as directed.
Supply only running capacitor for upto 300/320 Ltrs capac ty deep freezer complete all as specified and as directed.
Supply only thermostat suitable for upto 300/320 Ltrs capacity deep freezer complete all as specified and as directed.
Supply only starting capacitor for upto 300/320 Ltrs capac y deep freezer complete all as specified and as directed.
Taking down defective compressor of capacity 300/320 deep freezer of any make and supplying and fixing now sealed unit compressor a specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant ga Won C-C based or equivalent to Non CFC gas in required qty and testing complete all as specified and as directed.
M&L for taking down desert cooler of any type/size/mode from any height / floor for servicing like changing of wood wool pads, kit motor Eas submersible pump, fan blade, front grill, wining, capacitor, cleaning or any other repar work is specified and re-fixing to existing place after repair work/overhauling complete all as specified and as directed. Note (1) The rates quoted by the contractor shall deemed to include the cost of T&P (2) The items required to be replaced shall be measured and paid separately under rolevant items.
Supply only wood wool pad of suitable site for 24 sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pad As per sample complete all as specified and as directed.
All as per item No 57 above but 20 sweep approximate weight 700-800 Gms As per sample complete all as specified and as directed.
Supply only submersible pump (tullu pump) motor 230 Volts, single phase, AC complete all as specified and as directed. Make-Little/ Cromptor/Khaitan
S&F in replacement of New fan motor with copper winding including suitable fan blade of existing capacity and size for desert coolers complete all as specified and as directed.
Supply only PVC front gril for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicating samp complete all as specified and as directed. (As per Samole)
Supply & fixing wire mesh for desert cooler pad (Set of Thee) complete all as specified and as directed.
Supply & fixing PVC pips for connecting pump and water distributor of size 15 mm dia. As per sample complete all as specified and as directed.
Supply & fixing PVC elbow for desert cooler As per sample complete all as specified and as directed.
Supply & fixing PVC 4 Way distribution cross for desert cooler As per sample complete all as specified and as directed.
S&F in repairs & replacement flexible copper conductor cable PVC insulated & PVC sheathed of size 14/1076 complete all as specified and as directed. (Make-Flaza/Kalinga)
S&F in replacement desert coolers fan blade of 18" (inch) sweep make out of Plastic/Aluminum complete all as specified and as directed.
S&F in replacement desert coolers fan blade of 20" (inch) sweep make out of Plastic/Aluminun complete all as specified and as directed.
Supply and fixing in repairs side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed.
S&F in replacement swich piano flush type single pole one way 5Amp 230 V for desert cooler complete all as specified and as directed.
S&F replacement 3 pin plug top 5 Amp. 230V for desert cooler complete all as specified and as directed.
S&F in replacement desert cooler body of size 26 inch x 25 inch x 32 inch (height) with side panels (03 Nos) (abricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch 5 Amp piano switch and depth of water tank not less than 7" (inch) complete all as specified and as directed.
M&L for evacuation of Gas from the systam feeding the dry nitrogen by separating the low and high side of the system and leuk testing the 4 same arresting the leaks including S&F in replacement of Teflon sealing of all refrigerant no valves of compressors, gland packages of att angle valves fiaring of all connections framing welding angle valves flaing of all connectic is framing welding etc complete ncluding gas charging of Cenizal Type AC plant of capacity 3X 35 TR complete all as specified and as directed.
Supply and charging refrigerant R-22/Gas of approved rake in new sealed cylinde complete all as specified and as directed.
Repair/maintenance/servicing complete unit of AHU's of AC plant 3X7.5TR Capacity system and cleaning of metallic finers and cooling coils with cleaning agent folowed with pressurized water jet at AFSSR including repair to niszzle and spraying pipe clamps and the rod replacement, cisaning at FRB shuts and fixing HW FRP cover to air motor complete all as specified and as directed.
Dismantling the existing water cooled condenser of Cap 3x7.5TR of shell and tube type from its pipe line and gas connection repairing the same by replacing the defective copper tubes by new one with existing size and dia, Cleaning the shell complete assembly the new and serviceable tubes charging testing for 350 PSI pressure complete all as specified and as directed. Note Rate quoted shall be inclusive of copper tubes.
M&L for repair to control panel with replacement of contractor relay timer switch starting switchs complets wiring of pane and connection Replacement of imported contrcis pressure, switches gauges, modulating valves, modulating motors, microprocessor and BVS components of comecessor unit 1 to 3 at 2x7.5 TR AFSSR EMVEMC LAB complete all as specified and as directed.
Supply upply and fix in replacment butterfly valves suitable for Gl pipe complete incited finecting the old and nuts 65/100mm as per site replacmeent complete all as specified and as directed.
M&L for rewinding of induction Electric Motor upto 3/5/7HP Capacity of any Make and size complete with super enameled copper wire oF existing gauge including Varnishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
M&L for repairing the cooling tower of AC Plant 3x7.5 TR at EMUEMC lab by Strip opening of the parts such as CT fan motor, fan, fan blades. PVC fins, sprinkler, tie rod eliminator, electric connection complete and removing silt deposited inner part of the cooling tower by wire brush, PVC branch pipe and applying solvent as applicable and refoxing the same after repairs/modification etc complete all as specified and as directed.
S&F Power Contactor MNX-40 with Aux contacts 1 NO +1 NC of range AC1-110A & AC3-110 A complete all as specified and as directed.
Comprehensive, preventive and periodically maintenance of the HVAC VRV Unit Make- Hitachi, Model : RAS-13+ NBCMC - Qty-2 No's and RAS 14GNBCMQ1 Qty-01 No's total 34. HP along with respectively Indoo units Qty -11 Nc's of deferent rati 193 (4.5 HP ductable unit-02 no's, sp it- 02 HP-Qty-02, Cassette uni 3HP -7No's. By ir specting the all units and carry out quarterly as a part of preventive maintenance, with relevant PM checklist. Checking the refrigeration system, motor arıd starters and ensuring healthy condition of the plant. Checking the system for any leaks and rectification of leaks found Taking set of readings and eva usting to ensure satisfactory perfo mance of the plant, Checking the Refrigeration control system for operation and adjusting the settings, Checking the functioning of compressors and its accessories, Cleaning the IDU evaporator ODU condenser coil: half yearly,, Lubricating the bearings of motors, & fans when found necessary, Quarterly inspection of belts adjusting the tension and replacing the worm out belt as and when found required, Replenishment of refrigeration gas as a result of fare wear and tear, Overhauling the components of the equipment at site or in service station as and when required. Checking of the microprocessors PCBs and sensors of IDU/ODU units for its proper unctioning and repair replacement of the same if found necessary, Attending to complain breakdown calls whenever required, Carrying out external cleaning (chemical or with water of condensor coils of outdoor unit, Reporting the healthiness of the plant and suggesting improvemerits if any, complete all as specified and as directed. Scrap items except items taken below will be property of contractor and cost of same shall be inclusive in quoted rates.
Comprehensive, preventive and periodically maintenance of the Chiller Plant Make- Blue box/ Swegon, Mcdel : ZP182KCE-1FD-477-Qty-3 No's and total Capacity 22X3-66 TIR along Primary pumps-5HP/2.5KW, Qty -3 No's including 4 No's AHU, including chiller LT panel, By inspecting the all units and carry out quarterly as a part of preventive maintenance, with relevant FM checklist. Checking the refrigeration system, motor and starters and ensuring healthy condition of the plant. Checking the system for any leaks and rectification of leak found, Taking set of readings anci evaluating to ensure satisfactory performance of the plant, Checking the Refrigeration control system for operation and adjusting the settings, Checking the functioning of compressors and its accessor es, Cleaning the IDU evaporator ODU condenser coils half yearly, Lubricating the bearings of motors, & fans when found necessary, Quarterly inspection of belts adjusting the tension and replacing the wom out belt as and when found required, Replenistiment of refrigeration gas as a result of fare wear and tear, Overhauling the comporrents of the equipment at site or in service station as and when required Checking of the microprocessors PCBs and sensors of IDU/ODJ units for its proper functioning and repair replacernent of the sanie if found necessary, Attending to complain breakdown calls whenever required, Carrying out external cleaning (chem cal or with water of condensor coils of outdoor unit, Reporting the healthiness of the plant and suggesting improvements if any, complete all as specified and as directed. Scrap items except items taken below will be property of contractor and cost of same shall be inclusive in quoted rates.
Comprehensive, preventive and periodically maintenance of the Precision air condition (PAC) Unit:Make Blue box/ Swegon, Model :DATATEC VEDA10-1CH-Qty-3 No's and total Capacity 5X3-15 TR. including PAC LT Panel by Inspecting the plan system and carry out preventive maintenance as par the standard practice quartely in contract period with relevant PVM checklist. Checking the refrigeration system, motor and starters and ensuring healthy conditiori of the plant, Checking the system for any leaks and rectification of leak; found, ensure drain is not cloggec Taking set of readings and evaluating to ensure satisfactory performance of the plant, Checking the Refrigeration control system for operation and adjusting the settings, Checking the functioning of compressors and its accessories, Cleaning up of units & ai fi ters, check the proper functioning of controllers, Lubricating the bearings of motors, & fans when found necessary, Freplenishment of refrigeration gas is a result of fare wear and tear, attend all breakdov incalls with in 2-4 hours, replaced worn out parts with in 24 hours subject to normal wo king days, Overt auling the components of the equipment at site or in service station as and whert required, Checking of the microprocessors PCBs and sensors of IDU/ODJ units for its proper functioning and repair replacement of the same if found necessary, Attending to complain breakdown calls whenever required, Reporting the healthiness of the plan and suggesting improvements if any, complete all as specified and as directed. Scrap items except items taken below will be property of contractor and cost of same shall be inclusive in quoted rates.
Supply only following spares parts against iterr no. 82 to 84:- The item ment oned below (Itum no. 85.01 to 85.05) are not the part of comprehensive maintenance, supply and tix of these items( item no. paid separately).
Supply only Refrigerant 4-10 for VRVand Chiller Unit.
Supply only Inverter control card for the unit (Make: Hitachi, Model RAS-10HNBC IQ1.
Supply only expansion solenoid coil for the unit (Make: Hitachi, Model RAS-10HN BCMQ1.
Supply only Indoor Cassette AC control Card.
Supply and fixing Chiller compressor for Bluebox Chiller ZP182KCE-1FD-477.
Comprehensive, preventive and periodical maintenance of total 2 Nos UPS of capacity (60 KVA- 01 Nos, Sr No. 9190501007, 250 KVA- 01 Nos Sr No. 9190800391, make/model: DPA U SCALE /ABB, By inspecting the all units and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.by Cleaning up of Unit, Visual Inspection to check any deformation, Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current, Checking and Adjustment of Control parameters on different PCBs,Tightness of all connection,Functional Checking up of Rectifier section, Functional Checking up of Inverter section, Functional Checking up of Static Switch Section, With user approval, perform operational test of the system including unit transfer and battery discharge, Attending to complain breakdown calls whenever required, UPS failing to transfer to battery mode in the event of incoming power failure, Battery Breaker tripping due to battery failure, Battery Failure, UPS unable to transfer load on to the parallel UPS (Redundancy Failure), UPS tripping on High temperature conditions, Control Card, major components failure such as IGBT’s, SCR’s & Wire wound Components within the UPS, Module Failure, Wire Harness damage, Reporting the healthiness of the plant and suggesting improvements if any, all as directed and specified by Engr-in-charge. Defective parts discovered during maintenance repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent. Old/U/sParts/scrap items except items taken below will be property of contractor and cost of same shall be inclusive in quoted rates. Batteries bank replacement is not part of Comprehensive AMC Contract.
Comprehensive, preventive and periodical maintenance of total 2 Nos UPS of capacity (10 KVA- 02 Nos, Sr No. ZOV18C00298WT & Sr No. ZOV18600305WT ,Make- Delta, Model :GES103HH, By inspecting the all units and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.by Cleaning up of Unit, Visual Inspection to check any deformation, Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current, Checking and Adjustment of Control parameters on different PCBs,Tightness of all connection,Functional Checking up of Rectifier section, Functional Checking up of Inverter section, Functional Checking up of Static Switch Section, With user approval, perform operational test of the system including unit transfer and battery discharge, Attending to complain breakdown calls whenever required, UPS failing to transfer to battery mode in the event of incoming power failure, Battery Breaker tripping due to battery failure, Battery Failure, UPS unable to transfer load on to the parallel UPS (Redundancy Failure), UPS tripping on High temperature conditions, Control Card, major components failure such as IGBT’s, SCR’s & Wire wound Components within the UPS, Module Failure, Wire Harness damage, Reporting the healthiness of the plant and suggesting improvements if any, all as directed and specified by Engr-in-charge. Defective parts discovered during maintenance repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent. Old/U/sParts/scrap items except items taken below will be property of contractor and cost of same shall be inclusive in quoted rates. Batteries bank replacement is not part of Comprehensive AMC Contract.
Comprehensive, preventive and periodically maintenance of the Main LT Panel: Capacity - 2 No. 1250 A 4P, 50kA (Ics=Icu=Icw for 1s) EDO ACB LSIG with microprocessor based built-in over current, earth fault, short circuit releases, auxiliary contacts, status indication on release, release healthiness indication & ON-OFF-TRIP indication for each and necessary protection CT's of suitable ratings. (For transformer ), 2 No. 1250 A 4P, 50kA (Ics=Icu=Icw for 1s) EDO ACB LSIG with microprocessor based built-in over current, earth fault, short circuit releases, auxiliary contacts, status indication on release, release healthiness indication & ON-OFF-TRIP indication for each and necessary protection CT's of suitable ratings. (For DG ) Bus coupler- 1 No 1250 FP ACB 50 kA . The Interlocking in the main incoming ACB's to be done as per the DG AMF Panel Load management & Load sharing is to be done through DG controller & controller of DG shall be interlocked through DG AMF Panel. First DG will act as master & second DG will act as slave ( Both the DG shall be programmed such that both could run for no of hours ) Along with PLC Micro 830 for the Auto operation. Outgoings:- 2 Nos 800 A ACB - 50 kA & , 5 Nos. 100 A FP MCCB (16 kA/1 sec), 4 Nos. 63 A FP MCCB (16 kA/1 sec) , 2 No. 40 A FP MCCB (16 kA/1 sec) , 1 No. 25 A FP MCCB (16 kA/1 sec) , 1 No. 500 A FP MCCB (16 kA/1 sec) by carry out preventive maintenance of the complete panel on quarterly basis, checking the all control wiring, breaker, relay's and other related accessories of the panel like load manager, control MCB's, contactor's ..etc. Attending to all breakdown complaints whenever required, carry out external cleaning.
Comprehensive, preventive and periodically maintenance of the APFC PANEL :195 Kvar - Main I/C- 1 Nos.500A TP MCCB 16 kA (O/C, S/C, E/F). Terminals suitable to receive suitable aluminum armored cable connection on one side and Busbar connection on the other side. 1 Nos contactor- 400 A, AC6b, 3pole, relay- 3 phase outgoing:- 2 No. 125 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch. 3 pole capacitor grade contactor suitable for automatic switching of 50 kVAR capacitor bank, 1 No. 80 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch, 3 pole capacitor grade contactor suitable for automatic switching of 25 kVAR capacitor bank, 3 pole capacitor grade contactor suitable for automatic switching of 10 kVAR capacitor bank, 10 kVAR hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc., 6 Nos. 16 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch. 5 kVAR hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc. complete as required. 1 No. 12-step APFCR and allied control wiring with in-built power factor meter. By inspecting the all system and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.checking the all control wiring, breaker, relay's and other related accessories of the panel like load manager, control MCB's, contactor's ..etc. Attending to all breakdown complaints whenever required, carry out external cleaning,all as directed and specified by Engr-in-charge.
Note for item no: 86 to 89 (i) The tenderer shall have to replace the U/s material with OEM material only. The cost of replacement of minor/major spare parts will not be paid seperatly. Old material will be the poperty of contractor and credit included in the rate quoted. (ii) In case any accident occur of any Indl like Mechanic/Helpers/users during maintenance/operation of above mentioned Airconditioner/unit, contractor is liable to pay compensation to the Indl as decided by the competent authority. Principal Employer will not be responsible for the same. (iii) If complaint is not attended by contractor with in five hour the penality of Rs 1000/ per hour to be imposed and amount of penality will be deducted from RAR. (iv) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site , stationary for maintenance of record, no extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE/GE every day as a token of complaint attended.
Taking out unserviceable fire hydrant door complete and S&F New door of size 2.10m x 0.75m including chowkhat made of MS angle 40 x 40 x 6mm frame and lower half portion with MS Sheet of 3.15, thcik and half of upper portion fixed the glass of 4mm thick including painting with fire red and plaster/cement work etc as required at site complete all as specified and as directed.
Supply and fixing, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 250 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color including taking down old complete all as specified and as directed.
Supply, fixing, testing and commissioning of wall mounting swinging type First aid fire hose reel with drum,hanging bracket,30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gun metal shut off nozzle having 5mm dia orifice.The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement and the rate for fixing/hanging items in the rates quoted(for internal hydrant and one each an either side of stage) including taking down old etc complete all as specified and as directed.
Supply and fix fire hydrant landing valve type A (single head outlet) gun metal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to IS 903 including taking down old complete all as specified and as directed.
Supply, fixing, testing and commissioning of 100mm dia, heavy duty class "C" MS pipe 6 mm thick, ISI marked as per IS : 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer including taking down old etc complete all as specified and as directed.
Supply, fixing, testing and commissioning of 80mm dia, heavy duty class "C" MS pipe 6 mm thick ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees , elbows ,flanges ,reducers ,gaskets ,nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer includingtaking down old etc complete all as specified and as directed.
M&L for making connection from riser to to hose reel drum with GI pipe Medium grage of size 25mm dia including GI Socket, Elbow, Tee, Nipple, socket etc all materials required at site complete all as specified and as directed.
M&L for replacement of gate/butterfly valve 25mm dia of cast copper alloy including taking down old complete all as specified and as directed.
M & L for replacement of CI non return valve of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and as directed.
M & L for replacement of CI sluice valve class PN 1.6 of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and as directed.
M & L for replacement of Fire Brigade inlet connection 2 way if size 80mm dia including Nut, bolts, wahsher etc including taking down old complete all as specified and as directed.
M & L for wheather protective cover for 15 HP Centrifugal/ Jockey Pump made out of MS sheet of 3.15mm thick of size 1.2M x 1.0M screwed over MS Angle of size 30mm x 30mm x 5mm having four legs grouted with nuts and bolts with suitable height for proper working space including painting of two coat of synthic enamelled paint over ove coat of red oxide etc complete all as specified and as directed.
M & L for replacement of Fire alarm control panel complying with BS EN 54 two loop panel of capacity from 99 detectors & 99 modules for 8 zone to detect 07 floor Addressable manual call point and modulesetc including taking down old complete all as specified and as directed.
M&L for replacement of Power contactor, 3 pole, MNX 22 type (AC3 rating 22 Amp and AC1 rating 32 Amp as per Cat No CS94980 of make L & T including taking down old & unserviceable complete all as specified and as directed.
M&L for replacement of Bimetal Over load Relay, 3 pole, MN-2 direct mounting on MNX-22 type of relay range 14-23 Amp as per Cat No SS94144OODO of make L & T including taking down old & unserviceable complete all as specified and as directed.
M&L for Single Phase Preventer, VSP2 type, 415 volts, 50 Hz including taking down old & unserviceable complete all as specified and as directed.
M&L for MCB TP, 63 Amps, 415 volts including taking down old & unserviceable complete all as specified and as directed.
M&L for MCCB TP, 100 Amps, 415 volts, breaking capacity 25 KA including taking down old & unserviceable complete all as specified and as directed.
M&L for Submain wiring in PVC conduit with 2 x 2.5 Sqmm and 1x2.5 sq. mm earth wire wire copper conductor multistranded, run through existing PVC conduit not less than 20mm dia complete all as specified and as directed.
M&L for Submain wiring in existing surface/recessed steel/PVC conduit with 2 x 2.5 Sqmm and 1 x 2.5 sqmm earth wire wire copper conductor multistranded, PVC conduit not less than 20mm dia complete all as specified and as directed.
M&L for Fire alarm MS Hooter including taking down old & unserviceable complete all as specified and as directed.
M & L for replacement of Pressure gauge 4"dial 0-14 kgs rating complete all as specified and as directed.
M & L for replacement of Pressure switch Universal type (HPLP) complete all as specified and as directed.
M & L for replacement of Addressable manual call point resettable type complete all as specified and as directed.
S&F Non percolating Reinforced Rubber Lined Hose (RRL) type A-63 mm x 15 mtr with male and female coupling complete all as specified and as directed.
M&L for taking down 12.5 HP centrifugal pumpset from the existing platform for carrying out repair pumpset & removing the following unserviceable parts and assemble the same properly after replacement of unserviceable parts and reconnection in position after repair the same in position with new nut & bolts suitable for fixing after carrying out the repairs including testing and commissioning complete all as specified and as directed. Notes : No extra amount shall be paid for the following items:- (a) Ball bearing of Motor (63088ZZ), (b) Rotor Balancing of Motor, (c) Sleeves of Pump, (d) Glain Bracket Complete, (e) Ball bearing of Pump (6305Z), (f) Overhauling Charges, (g) Alignment of Pumpset, (h) Opening and fitting of Pumpset at site.
Saini Enterprises
Shiv Enterprises
DP Traders
A B K Enterprises
J.P. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .