Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.6 L
EMD Value
₹5,267
Closing Date
14 Oct 2026, 10:00 am4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Joint Project Manager (Electrical), HRBC
ST. GEORGES GATE ROAD (MUNSHI PREM CHAND SARANI) KOLKATA-700 021
Supply and Installation of new 9 Mtr. Long GI octagonal pole with LED fitting fixture and allied electrical accessories for VIP lane in front of Toll Plaza under HRBC, Kolkata.
2026_HRBC_1044879_1
HRBC/JPM(E)/NIT/11/26-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
7 days
KOLKATA
Please refer Tender documents.
6 documents required · 6 mandatory
₹750
₹5,267
7 Oct 2026
7 Oct 2026
16 Oct 2026
7 Oct 2026
14 Oct 2026
7 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of 9 Mtr. HDG Octagonal Poles in 3 mm shaft thickness in MS Condition before Galvanization with Top A/F 70 mm, Bottom A/F 155 mm, Base Plate 260x260x16 mm suitable for wind speed 180 Km/hr. as per IS:875 and 4 Nos. M20x700 “J” Type Foundation Bolts as per EN-8 (Min UTS-600) & Anti-theft locking door arrangement for safety of MCBs, Terminal etc.
A)Material grade of shaft shall be of S355 JR as per BSEN 10025 or Equivalent IS: 2062 grade E350 (BR)
B)Materials grade of Base Plate shall be E250(BR) as per IS:2062
C)Galvanization as per BSEN ISO:1461
D)Fusion Welding as per ISO 3824-2:2021
E)All Tests are to done from OEM own-in-house NABL accredited Lab for proper quality control. Valid NABL lab certificate to be uploaded in tender.
F)OEM having own in-house galvanization facility for betterment of quality of the product. OEM Factory license to be uploaded in tender.
G)Make- Transrail/Valmont/Bajaj/Skipper
Following documents are to be required to process the bills-
1)Raw Material Test Certificate of Pole Shaft (IS:2062 grade E-350 BR) Make of HR Coil-TATA/SAIL/JSW/JSPL/RINL
2)Raw Material Test Certificate of Base Plate (IS:2062 grade E-250 BR) Make of Plate TATA/SAIL/JSW/JSPL/RINL
3)Raw Material Test Certificate of bracket Pipe (IS:1239 grade) from any reputed BIS Make.
4)Raw Material Test Certificate of Zinc (Zn) Make-
Hindustan Zinc(Vedanta)
5)Raw Material Test Certificate of Foundation bolts (EN Grade EN-8 and UTS.>600) any reputed BIS Make | 2 | Nos. | 28,301 | ₹56,602 |
| 2 | 1500 mm HDG Double Arm Bracket made of (48.3 ODx2.9 thik.) Mild Steel Pipe as per IS:1239 suitable to insert at Pole Top A/F 70 | 2 | Nos. | 2,932 | ₹5,864 |
| 3 | Installation, Commissioning and Testing the said 09 Mtr. long G.I. Octagonal pole by Providing, constructing and completing RCC foundation for 9.0 m high octagonal street light pole, with M20 grade RCC, with 8mm and 10mm MS TMT bar and the concrete area having sizes 600 x 600 x 1500mm for pole considering the safe soil bearing capacity. | 2 | Nos. | 16,223 | ₹32,446 |
| 4 | Supply and fixing of 240 Volt, 50Hz, 150 watt LED street lighting luminaire. (Make -Crompton/ Philips/ Wipro/LT/Jaquar).
i) Lumen efficacy > or = 135 Lumen/ Watt,
ii) CCT- 5700K
iii) CRI = or > 70
iv) THD < or = 10%(at Full Load),
v) SDCM < or = 05,
vi) P.F = or > 0.95.
viii) Efficiency should be = or > 85%,
ix) The Driver(Make - XITANIUM / MEANWELL / OSRAM / INVENTRONICS) should be a potted driver and mounted inside the luminaire. Wattage of the Driver should always be greater than OR equal to the Wattage of the Luminaire.
x) The LED chip module(make- Osram / Nichia / Cree or Bridgelux etc.
xi) LED chip module should not be overdriven or underdriven by the driver as compared to its rated current as per OEM standard.
xii) The luminer must have pure polyester powder coated pressure die cast Al. housing IP 66, impact resistance IK >= 07.
xiii) SPD internal should be 4 KV and external should be 10 KV,and covered in proper housing.
xiv) Luminaire and Driver both should have the life of 75000 burning hour @ L70B50, having LM79, LM80, BIS type test report from a NABL accredited Govt. LAB.
xv) Each Light fittings should be of 05 Years Warranty approved from minimum rank of Regional Manager level or Equivalent of the manufacturing Co. & from the Agency. | 4 | Nos. | 7,831 | ₹31,324 |
| 5 | Earthing by 3.0Mtr. long 50mm dia G.I. pipe (ISI Medium) with GI wire. | 1 | no | 1,524 | ₹1,524 |
| 6 | Supply and fixing of 6A SP MCB 2 nos. and 1 no. 4H terminal block for pole sludge/ loop box. (Make – L & T/ Legrand / Havells/Simences) | 2 | Nos. | 1,514 | ₹3,028 |
| 7 | Supply and delivery of 1.1 KV grade PVC insulated XLPE aluminum armored cable 4 core 10 sq. mm. (Make- HAVELLS /KEI/GLOSTER/POLYCAB) | 150 | mtr | 318 | ₹47,700 |
| 8 | Laying of one No. cable upto 35 sqmm in under ground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed | 105 | Mtr | 162 | ₹17,010 |
| 9 | Laying only Cable upto 50 sqmm through existing RCC/ Hume/GI Pipe for single, 2, 3, 3½ and 4 core. | 45 | Mtr | 127 | ₹5,715 |
| 10 | Supply and fixing of 50mm dia G.I. Pipe (ISI Medium) for necy. Cable protection after butuminious road cutting. (Make - TATA/BANSAL/JINDAL) | 45 | mtr | 383 | ₹17,235 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tendernotice_2.pdf
PDF • 0.41 MB
Tendernotice_3.pdf
PDF • 1.05 MB
BOQ_2562156.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .