Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 CrAccepted-AOC | ₹10.5 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹11.2 CrRejected-Finance | ₹11.2 Cr | L2 | Rejected-Finance Not Being lowest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Recommended Due to adverse remarks in the WLR circulated by HQ CENC for QE Mar 2025. |
| Sl No | Description | Qty | Unit | SHIV CHARAN GUPTA AND SONS L2 | DES RAJ CONTRACTS PVT. LTD. L1 |
|---|---|---|---|---|---|
| 1.00NOTE: Schedule ‘A’ Part - I to Part -XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||
| 1.01 | Total amount of Sch 'A' Part - I (BUILDINGS) | 1 | LUMP SUM | 6,09,19,439.3 ₹6.1 Cr | 5,72,42,949.3 ₹5.7 Cr |
| 1.02 | Total amount of Sch 'A' Part - II (SITE CLEARANCE WORKS) | 1 | LUMP SUM | 42,04,226.3 ₹42.0 L | 30,57,618.3 ₹30.6 L |
| 1.03 | Total amount of Sch ‘A’ Part - III (PROTECTIVE WORK) | 1 | LUMP SUM | 17,11,829.06 ₹17.1 L | 14,20,818.13 ₹14.2 L |
| 1.04 | Total amount of Sch ‘A’ Part - IV (ROAD WORKS) | 1 | LUMP SUM | 37,42,844.79 ₹37.4 L | 39,48,872.94 ₹39.5 L |
| 1.05 | Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL WORKS) | 1 | LUMP SUM | 2,14,796.54 ₹2.1 L | 1,68,994.34 ₹1.7 L |
| 1.06 | Total amount of Sch ‘A’ Part - VI (SECURITY WALL WORKS) | 1 | LUMP SUM | 1,49,31,818.05 ₹1.5 Cr | 1,34,03,364.24 ₹1.3 Cr |
| 1.07 | Total amount of Sch ‘A’ Part - VII (INTERNAL WATER SUPPLY WORKS) | 1 | LUMP SUM | 59,482.73 ₹59,482.73 | 47,969.31 ₹47,969.31 |
| 1.08 | Total amount of Sch ‘A’ Part - VIII (INTERNAL ELECTRIC SUPPLY WORKS) | 1 | LUMP SUM | 12,39,681.72 ₹12.4 L | 11,45,129.73 ₹11.5 L |
| 1.09 | Total amount of Sch 'A' Part - IX (EXTRNAL WATER SUPPLY WORKS) | 1 | LUMP SUM | 5,91,441.99 ₹5.9 L | 6,17,583.07 ₹6.2 L |
Tender Value
₹10.8 Cr
EMD Value
₹8.6 L
Closing Date
20 Aug 2025, 6:00 pmClosed
CE Leh Zone
HQ CE Leh Zone
PROVN OF WKSP REPAIR EST AT LEH UNDER GE I P NO 1 LEH
2024_MES_668019_3
180100
Open Tender
Civil Works
900 days
LEH
As per tender documents
12 documents required · 12 mandatory
₹3,000
GE (I), (P) No. 1, Leh
₹8.6 L
Leh
30 Sept 2025
22 May 2025
27 Aug 2025
22 May 2025
20 Aug 2025
21 Jul 2025
23 May 2025 - 29 May 2025
30 May 2025
Amount
NOTE: Schedule ‘A’ Part - I to Part -XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Total amount of Sch 'A' Part - I (BUILDINGS)
Total amount of Sch 'A' Part - II (SITE CLEARANCE WORKS)
Total amount of Sch ‘A’ Part - III (PROTECTIVE WORK)
Total amount of Sch ‘A’ Part - IV (ROAD WORKS)
Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL WORKS)
Total amount of Sch ‘A’ Part - VI (SECURITY WALL WORKS)
Total amount of Sch ‘A’ Part - VII (INTERNAL WATER SUPPLY WORKS)
Total amount of Sch ‘A’ Part - VIII (INTERNAL ELECTRIC SUPPLY WORKS)
Total amount of Sch 'A' Part - IX (EXTRNAL WATER SUPPLY WORKS)
Total amount of Sch 'A' Part - X (EXTRNAL ELECTRIC SUPPLY WORKS)
Total amount of Sch ‘A’ Part - XI ( STREET LIGHT WORKS)
Total amount of Sch ‘A’ Part - XII ( STANDBY DG SET FOR CHS WORKS)
SCH 'A PART - XIII (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-XII) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
Supplying and fixing 30 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge.
Supplying and fixing 10 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge.
Construction of soakage well 2.4m internal dia and 3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings.
Construction of soakage well 1.2m internal dia and 3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings.
Supplying and fixing for Concertina Coil Punched type 610mm dia razor type made out of 2.50 mm dia SG hot galvanised spiring tensile wire 145 to 150 N/SQMM zinc coating 240 gms/sqmm (min) weight of coil shall be minimum 8.57 kg/coil shall be 6.25 RM after laying, min Nos of turns in each coil shall be of 49/50. Galvanized razor ribbon type shall be of size 0.50 mm thick, 19 mm side before wrapping on central core wire. Concretina coil shall be fixed to existing angle iron swan neck supports using GI clips 125 to 127 Nos per coil and special nuts and bolts for holding Z coil together and extra two rows parallel wire of 10 gauge etc all as specified.
M&L for MS wicket gate as Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge.
M&L for 5.5 Mtr Wide gate with pillers Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge.
Supply, Install, lowering, testing, and commissioning of submersible openwell pumping sets, centrifugal, electric driven,minium discharge of 23.46 LPM at 33 mtr head motor capacity minium 3 HP including 3 HP Starter complete all specified and directed.
h) Space for Provn of DOL starter 3 HP - 02 Nos All as required including foundations as per Manufacturers recommendations all as required at site or as directed by Engr-in-Charge. (j) As per IE rule and latest is, necessary colour coding for 'R', 'Y', 'B' and 'N' shall be made with different colour as per IE rule.
Supply and fix submersible copper conductor cable 3 core, 4 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all specified and directed.
M&L for Construction of brick masonary valve pit of size.0.9X0.9X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm, with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle all as specified and directed by Engr-in-charge.
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Main LT Panel)(Near Prop Transformer) (a) AI bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 2400 Amps. (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps - 01 No for incoming (c) As per IE rule and latest is, necessary colour coding for 'R', 'Y', 'B' and 'N' shall be made with different colour as per IE rule.
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Sub LT Panel) (Near workshop bldg) (a) Al bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 1000 Amps. (b) MCCB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 No for incoming (c) As per IE rule and latest is, necessary colour coding for 'R', 'Y', 'B' and 'N' shall be made with different colour as per IE rule.
Supply, installation, commissioning and testing of factory made, CPRI approved feeder piller box of size 0.9m x0.9m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including fwg:- (Feeder Pillar box) (Near washing platform)
Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
Supply, Installation, Testing & Commissioning of High galvanized mast light suitable for 8 luminaries symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation suitable for 12.5 Mtr height completed minimum dimension specified as under mentioned specifications. Note : As per IE rule and latest is, necessary colour coding for 'R', 'Y', 'B' and 'N' shall be made with different colour as per IE rule. (A) High Mast Structure 1. Matrial of Construction:- HR sheet steel conform to IS 2062/BS EN 10025 or Equivalent 2. Base Dia. and top diameter (A/F) 1. Top Section - 150 mm 2. Bottom Section - 360 mm 3. Plate thickness :- Top - 3mm, Bottom - 3 mm 4. Cross Section of Mast (Number of Slides) - 20 Sided Polygon 5. Standard of galvanisation - As per BS EN ISO 1461 6. Size of opening and door at base - 1050 x 225 mm 7. Diameter of base plate - 520 mm 8. Thickness of base plate - 25 mm 9. Lighting protection finial - G.I single spike
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 250 Amps rating with rupturing cap 36 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F, installation, commissioning and testing Junction boxes made of Lid PC and base is polystyrene. Junction Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The junction box shall have an optional cable entry at the bottom up Cable Size 25 Sq mm of the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closed will be tool operated. it will be sealable with accessories. The junction box shall have elongated holes inside them for wall/pole mounting provision. The junction box with 4 Pole Terminal Strip and MCB SP 6 Amp 10 KA C Curve for LED light.
The junction box shall fulfill the following standards Weatherproof : Rainwater proof, temperature resistant. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. IEC 60529 : IP 65 degree of protection. UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4 The Junction Box with Suitable Glands 3 Nos with each and chromium plated clamps, nut bolts complete all as per manufacturer’s instructions.
Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories including foundation all as specified and directed.:- (Main LT Panel ) INCOMING: (a) Aluminium bus bar 3 phase 4 strip suitable for 30 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves- 01 No. (b) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 16 Amps - 01 No Incomer
Supply and fixing LED blub full dum 7 watt with rechargeble type, retrofit all as specified and directed by Engr-in-charge
S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 100 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 200 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
Supply and Fixing of 40W LED High Bay light with Surface mounted device(SMD) with multiple LED with Borosilicate glass lens and acrylic, with aluminum reflector,operating Voltage between 140-270Vac, Power Factor more than 0.95%, intergal driver with 3KV surge protection differential mode/coman mode ,LED CCT 5665±355K as per ANSI BIN, Over load protection,No load Protection, Driver should be concealed under IP66 and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), System Lumen >4000, CRI>70, Over all electrical efficency more than 90%,connecting with PVC copper cable of size 3 core x 1 sqmm sqmm at least 2 Year on site warranty wihout any condition including taking down of old light fitting safely and removing from site complete all as specified and directed.
SCH 'A PART - XIV (HOT WATER SUPPLY) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
S&F BIB TAPS, chromim plated cast copper alloy with capstain head, screwed for 20mm bore dia iron pipes or for brass ferruble and fixed complete all specified and directed.
S&F PVC connection 15mm dia with PTMT nuts of length 450mm complete all as specified and directed.
SCH 'A PART - XV (CENTRAL HEATING SYSTEM) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
Electric Hot Water Generator : Supply, installation, testing and commissioning of package type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 150 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches.
(a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price. (b) The prices should include lifting, shifting and positioning of units at Site. (c) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structure etc as recommended by Manufacturer. (d) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity as per ISO or equivalent standard. (e) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler.
GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 rated Axial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with EFF1 type class 'F' insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal. Pumps with performance characteristics as given below: The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps .
The scope also shall include following below mentioned: (i) Electrical by pass starter for pump set as recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (iii) 3 Nos. - 150 mm dia type pressure gauges (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Pump capacity are as under: (vii) Capacity and pump head not less than flow 350 USGPM , Head 35 mtr each including the triple duct valve and End Suction guide. Note:- In 02 Nos working and 01 No standby configuration.
EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume of Glycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder.
The tank connection's should be as per OEM recommendations and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.
The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 1000 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G).
(a) Expansion Tank of 1000 Lts capacity for bldg
(b) PRESSURIZATION UNIT: for Pump Set -03 Nos (Ref. Point 4) with Control Panel and accessories for bldg.
Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 990 litres for Pocket-1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make up Water tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G).
Supply, Installation, Testing and Commissioning of ceiling/wall/floor Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2way wall with cordless remote. The Ball Valve with Strainer/ Shut off Value with Strainer at inlet and outlet of FCU including copper connection pipe for inlet and outlet should be provided. The Unit Capacity should be calculated as per BIS/ Eurovent Standard/AHRI Certification method. The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius and Below Mention External Static Pressure (ESP).
2.5 kW, ESP: 50 Pa (Reference Model No.: FWW200VC / Equivalent) (CHS Plant Room - Toilet )
5 kW, ESP: 50 Pa (Reference Model No.: FWW500VC/Equivalent) (Wkshp Toilet Area - 4 Qty, CHS Plant Room - Toilet- 1 Qty)
10 kW, ESP: 50 Pa ( Reference Model No.: FWW1000VC/Equivalent) (Staff Room: 2 Qty, SPL Shop, Tech TRG, Tech LIB, Inspection OFF, Office for Wksh- 1 Qty
12 kW, ESP: 100 Pa ( Reference Model No.:FUW015A/Equivalent) (Electricain - 1 Qty)
18 kW, ESP: 100 Pa ( Reference Model No.: FUW020A/Equivalent) (Office for QC n Fuel Injection - 1 Qty)
24 kW, ESP: 100 Pa ( Reference Model No.: FUW030A/Equivalent) (Mech Section- 1 Qty)
30 kW, ESP: 100 Pa (Reference Model No.: FUW035A/Equivalent) (Service Bay - 2 Qty Each Service Bay)
M&L for Pre - insulated MS pipe,Class 'C' having minimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
Inside Building
100 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
Buried under ground/Exposed to Ambient:
100 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
Supply,Installation, Testing amd commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipe in mms as inducated below:
25 mm dia pipe, Insulation thickness - 19 mm
32 mm dia pipe, Insulation thickness - 19 mm
40 mm dia pipe, Insulation thickness - 19 mm
CABLE TRAYS
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
150 mm width X 50 mm depth X 1.6 mm thickness
VALVES :
Supplying, fixing, testing and commissioning of following diameter valves(PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
100 mm dia Butterfly Valve
65 mm dia Butterfly Valve
Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.
65 mm dia Y STRAINER
NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified.
65 mm dia NRV
Automatic Air Purge Valves for hot water circulation header as specified and required by Engineer In Charge.
Automtic Air Purge Valve 20 mm dia
Air Separator (PN16)
SITC of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8" dia and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge.
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge.
Supply, installation, commissioning and testing of factory made, CPRI approved LT CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- As per IE rule and latest is, necessary colour coding for 'R', 'Y', 'B' and 'N' shall be made with different colour as per IE rule.
INCOMERS (a) Bus Bar TPN Al extensible type main bus bars of minimum of 1200 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 50kA . (b) ACB 800 Amps, 415 Volt, 50 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers) Make: Legrand/Schenider/Simens
OUTGOINGS (c) 4 Nos- 400A 10 KA TPN MCCB with Microprocessor release (3# Hot Water Generator) (d) MCB 5/6 Amp, 10KA, TPN - 02 Nos Pressurization PUMPs (e) MCCB 63 Amp, 10KA, C curve TPN - 03 Nos for Pumps (f) MCB 5/6 Amp, 10KA, SPN,- 07 No for Bldg load/FCU. Makes of MCBs: Legrand/Schenider/Simens (g) LED Phase indication lamps (01 Set) with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set
(h) Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set. (j) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge. Note : Contractor will submit the drawing of panel to GE before execution for approval.
Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)
3.5 Core x 240 sq.mm. (Electric Hot Water Generator)
4 Core x 10 sq.mm. (Pump)
4 Core x 6 sq.mm (Pressurization Unit)
2 Single core x 2.5 sq.mm. (FCU)
4 Core x 4 sq.mm (Boiler Pump)
Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size 2m * 1m * 25 mm complete all as specified & directed by Engr-in-charge.
GENERAL NOTES:-
1. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of : (a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings. (b) Wastage on materials and labour. (c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles.
(d) Liabilities, obligations and risks arising out of Conditions of Contract. (e) The unit rate for all equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required. 2. The contractor shall perform Nitrogen test and vacuum test on refrigerant piping. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by Engineer-in-Charge.
3. Cable glands shall be compression type, heavy-duty chromium plated. 4. All cable termination to have lugs/ thimbles. 5. INSTRUCTION / MAINTENANCE MANUAL
The Contractor shall prepare and produce instruction, operation and maintenance manuals in English for the use, operation and the maintenance of the supplied equipment and installations and submit to the Client / Consultant in (3) copies at the time of handing over. The manual shall generally consist of the following: (i) Description of the project. (ii) Operating instructions. (iii)Maintenance instructions including procedures for preventive maintenance. (iv) Manufacturers catalogues. (v) Trouble shooting charts. (vi) Schematic & control wiring diagrams.
(vii) Commissioning Certificate. (viii) Also for BMS System, Training,Opeartion, Installation manual and Trouble shooting manual and Training should be imparted to the field person. (ix) All neccassary license should be provided for the BMS free of cost I traning shall be of 02 week for 10 persons at site 6. For Make List If any make stated below does not comply with the technical specifications and or IS Standards then such a make shall not be used in the work. 7. MAINTENANCE OF PLANT AND TRAINING OF PERSONNEL The Contractor shall arrange to provide, at no extra cost, necessary personnel and material to carry out all routine maintenance of the CHS equipment as required regularly.
S&F insulation on tubing for 50mm dia pipe and 13mm thick of nitrile rubber including valve complete all as specified and directed.
S&F insulation on tubing for 40mm dia pipe and 13mm thick of nitrile rubber including valve complete all as specified and directed.
S&F insulation on tubing for 25mm dia pipe and 13mm thick of nitrile rubber including valve complete all as specified and directed.
S&F aluminum cladding of 28 SWG thickness on insulated pipe having 50mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
S&F aluminum cladding of 28 SWG thickness on insulated pipe having 40mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
S&F aluminum cladding of 28 SWG thickness on insulated pipe having 25mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
S&F of tracer wire 20W per mtr over pipeline/valve above freeze line complete all as directed by Engr-in-Charge.
SHIV CHARAN GUPTA AND SONS (BID ID -3399848)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid