Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.7 LAdmitted-Finance | -45.18% | ₹10.7 L | L1 | Admitted-Finance |
| 2 | L2₹9.5 LAdmitted-Finance | -51.51% | ₹9.5 L | L2 | Admitted-Finance |
| 3 | L3₹10.0 LAdmitted-Finance | -48.99% | ₹10.0 L | L3 | Admitted-Finance |
| 4 | L4₹12.9 LAdmitted-Finance | -34.20% | ₹12.9 L | L4 | Admitted-Finance |
| 5 | L5₹11.6 LAdmitted-Finance | -40.95% | ₹11.6 L | L5 | Admitted-Finance |
Tender Value
₹26.3 L
EMD Value
₹52,666
Closing Date
4 Mar 2026, 6:00 pmClosed
EXECUTIVE ENGINEER LIGHT PART-II
JAIPUR NAGAR NIGAM PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
Maintenance work of air conditioners (AC) installed in the headquarters building and zone offices of the Municipal Corporation of Jaipur Part-II area. Annual rate contract for the year 2026-27
2026_DLB_539974_1
56 EXECUTIVE ENGINEER LIGHT PART-II
Open Tender
Electrical and Maintenance Works
365 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹590
ONLINE PAY IN JAIPURMC WEBSITE
₹52,666
Yes
6 Mar 2026
19 Feb 2026
5 Mar 2026
19 Feb 2026
4 Mar 2026
19 Feb 2026
(55) DISTRIBUTION BOARD & ITS ACCESSORIES
(55.1) Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
(55.1.1) Single pole MCB (With B/C curve tripping Characteristics)
(55.1.2) 6 A to 32 A rating
(55.13) P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
((i)) 20 amp, 2 pin + scrapping Earth, 1 Module
(71) AIR COOLING & AIR CONDITIONING
(71.38) Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(71.38.1) Un Armoured
(71.38.1.3) 2 core x 2.5 Sq.mm
(71.39) Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(71.39.8) 15.9 mm O.D., wall thinkness >= 0.8mm (insulation – 13 mm thick)
(71.39.10) 9.5 mm O.D., wall thinkness >= 0.8mm (insulation – 13 mm thick)
(71.4) Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(71.41) Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(71.42) Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
(71.42.4) 200 mm dia per running inch length
(71.45) Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(75) REPAIRING OF FANS, COOLERS, PUMPS, MOTORS, FRIDGES & AIRCONDITIONERS
(75.42) Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter.
(75.42.2) 1.5 TR Window/ Split A.C.
(75.42.3) 2.0 TR Window/ Split A.C.
(75.43) Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.44) P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor
(75.45) Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner
(75.46) P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.47) P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.49) P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.71) P & Replacement of fan motor of evaporator/ condensor complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.72) S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.
(75.72.1) Starting capacitor
(75.72.1.3) 60-80 micro farad
(75.72.1.4) 80-100 micro farad
(75.72.2) Running capacitor
(75.72.2.3) 6.0 micro farad
(75.72.2.4) 8.0 micro farad
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (Part-B) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) (NON BSR )
NUMBER #
Replacement air conditioner filter
Descaling of Evaporator coils and condensing coil
Replacement Of Electrical Items
Replacement of Contactor
Replacement of defective PCB of suitable make for 1.5/2.0 TR AC.
Providing of remote as per model of existing of suitable make for 1.5/2.0 TR AC.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_963212.xls
BOQ • 0.34 MB
EPROC56XENLIGHT.pdf
Tender Documents • 7.49 MB
Download all tender documents and submit your bid