Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.7 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹22.4 L+₹46,860 (2.13%)Rejected-Finance | 2 | Rejected-Finance other than L1 | |
| 3 | 3₹23.5 L+₹1.6 L (7.07%)Rejected-Finance | 3 | Rejected-Finance other than L1 | |
| 4 | 4₹28.4 L+₹6.5 L (29.4%)Rejected-Finance | 4 | Rejected-Finance other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIRS TO ROOF TREATMENT FLOORING PLUMBING SEEPAGE LEAKAGE SUNKEN PORTION TREATMENT SANITARY FITTING AND CONNECTED WORKS IN CERTAIN MD AND OTM BLDGSAT VAYUSENABAD (AF) STN TUGHLAKABAD
2024_MES_655577_1
GE/TKD-41/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹0
₹70,000
Yes
13 Dec 2024
31 Aug 2024
28 Sept 2024
31 Aug 2024
26 Sept 2024
14 Sept 2024
Amount
M&L for 15mm thick (10+5) rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement including taking down loose cement plaster on brick, stone walls and concrete surfaces(except above mention in description 1 area) of any description/position etc including racking out joints, hacking for keys scrubbing down with water etc complete all as specified and directed by Engr-in-charge. Note :- All works to be carried out up to Approx 12 mtr height .Rates included to the necessary steel scaffolding required for execution of works upto Approx 12 mtr height from ground floor. No extra claim by the contractor for same. All dismantling/demolished material removed from MOD land completely.Rate of removal outside side from MoD land deemed to be included in the same item.
M&L for 15mm thick (10+5) rendering in CM 1:6 on other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement including taking down loose cement plaster on brick, stone walls and concrete surfaces(except above mention in description 1 area) of any description/position etc including racking out joints, hacking for keys scrubbing down with water etc complete all as specified and directed by Engr-in-charge. Note :- All works to be carried out up to Approx 12 mtr height .Rates included to the necessary steel scaffolding required for execution of works upto Approx 12 mtr height from ground floor. No extra claim by the contractor for same. All dismantling/demolished material removed from MOD land completely.Rate of removal outside side from MoD land deemed to be included in the same item.
M&L 5mm thick rendering in CM 1:3 on concrete surface as in ceiling finished even and smooth w/o using extra complete including taking down loose cement plaster on brick, stone walls and concrete surfaces(except above mention in description 1 area) of any description/position etc including racking out joints, hacking for keys scrubbing down with water etc complete all as specified and directed by Engr-in-charge. Note :- All works to be carried out up to Approx 12 mtr height. Rates included to the necessary steel scaffolding required for execution of works upto Approx 12 mtr height from ground floor. No extra claim by the contractor for same. All dismantling/demolished material removed from MOD land completely.Rate of removal outside side from MoD land deemed to be included in the same item.
M & L two coats of cement base paint over a coat of 1mm thick wall putty on newly plastered surface of walls to match the existing colour incl preparation the surface complete all as specified.
M&L preparing newly surfaces of ceilings and applying three coat of white wash on new surface all as specified.
M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper over 1mm thick wall putty on new wall surafce, complete all as specified.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying one coat of oil bound distemper white or tinted over a coat of white putty in patches as required all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or unplastered surfaces of walls. ceiling, chajja by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc, washing rubbing down and stopping of previously untreated/painted surfaces and applying one coat of cement base paint, white or tinted all as specified and as directed by Engineer-in-Charge. Note:- Quoted rate shall be deemed to be included for work in buildings/structure of any height.
Taking down old existing roof treatment of any type including mud fuska & brick tile and removing from MoD Land complete all as specified and directed by Engr-in-charge.
Cleaning of roof slab/chajja with sweeping with brooms, removing complete all as specified and directed by Engr-in-charge.
M&L for removing building old materials etc. (broken tiles, broken bricks, broken others building materials) to a distance of 1500m (out side of MoD land), beyond the lead included in the rates, including loading, unloading and stacking at the destination all as spfd and as directed by engr-in-charge
Demolition of cement concrete of any type description and in any position complete all as specified and directed by Engr-in-charge.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed by Engr-in-charge.
M&L for Providing cement concrete (1:3:6) Type C0 using 12.5 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified
Surface preparation of all foreign material such as grass roots dust/mud etc and roughening the concrete surfaces by wire brushes including 50 mm thick PCC 1:2:4 type B1 using 12.5 mm graded aggregate as in roof for maint the uniform slope and applying cement screed bed of 10 mm thick 1:4 with water proofing compound @ 3% weight of cement as per manufacture instruction with APP modified polymeric membrane centre core of 100 micron HMHDPE, weight not less than 3 Kg/Sqm and clear thickness of membrane not less than 3 mm thickness, on newly prepared surface with overlap while torching shall be 100mm on length side & 100mm on width side of memberance as per manufacturer instruction complete all as specifid and as directed with the following description. (a) Apply evenly a coat of bituminous primer conforming to IS -3384 @ 0.40 Kg/Sqm. (b) A coat of bonding bitumen confirming to IS -702 of grade 85/25 @1.20 Kg/Sqm as IInd course. (c) Laying of APP modified polymeric membrane as a IIIrd course. (d) A coat of bonding bitumen confirming to IS -702 of grade 85/25 @ 1.20 Kg/Sqm as a forth course.
M&L for 50mm thick (minimum) cement concrete M-20 (nominal mix) using 12.5mm graded stone aggregate mixed with integral water proofing power as per manufacturers instructions with proper slope towards spouts on bottom surface in sunken portion complete all as specified and as directed by Engr-in-Charge.
M&L for 15 mm thick plaster in CM (1:3) mixed with integral water proofing powder as per manufactures instructions on vertical side of sunken portion complete all as specified and as directed by Engr-in-Charge.
M&L for applying two coats of industrial bitumen 85/25 @ 1.50 Kg/Sqm over a coat of bitumen primer @ 0.30 Kg/sqm all over on bottom & vertical sides of the sunken portion. Note :- sunken portion shall be tested for water tightness by ponding water for 72 hours, the defect of leakage seepage if any shall be rectified till elimination complete all as specified and as directed by Engr-in-Charge.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified
M&L for PCC (1:4:8) type E-2 using brick koba aggregate for filled up the sunken portion complete all as specified and as directed by Engr-in-Charge.
M&L for 50mm dia GI light grade pipe for spout complete all as specified and as directed by Engr-in-Charge.
M&L 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top )including dismantling and hoisted and fixed in position etc complete all as per specified and directed.
M&L 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top )including dismantling and hoisted and fixed in position etc complete all as per specified and directed.
Demolition and breaking of AC pipe set in cement mortar 150/110mm dia complete all as spfd and directed by Engr in charge.
M&L for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall of 160 mm dia complete all as specified and directed by Engr-in-charge.
M&L for PVC (SWR) bend of 160 mm dia complete all as specified and directed by Engr-in-charge.
M&L PVC ( SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor of 110mm dia complete all as specified and directed.
Taking down or up 15 mm bore galvanised iron tubing and connection and S & F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
All as per serial item 28 here in before but 20 mm bore.
Taking down and refixing only old GI tubing 15 mm bore pipe and connections in new or old position as on walls ceiling floors etc all as specified and as directed
All as per serial item 30 here in before but 20 mm bore all as specified and as directed
S&F in repairs of stop valves cast copper alloy type screwed down high pressure with crutch or butterfly handle for 15mm bore complete all as specified and directed by Engr-in-charge.
S&F in repairs of Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm dia complete all as specified and directed by Engr-in-charge.
S&F in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastec ball screwed for iron pipe and fixed all as specified and as directed
S&F in repair bib tap of CP fancy type with butterfly handle screwed down screwed for iron pipe of 15mm bore complete all as specified and as directed
S&F in repair PVC PTMT bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore complete all as specified and as directed.
S&F in repair of Wall mixture 15mm bore dia cast copper alloy with cap capston chromim plated screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly buts screwed for iron pipe complete all as specified and as directed
S&F angle valves CP screwed down high pressure of fanciy type chromium plated screwed both ends for iron pipe or for union and fixed with 15mm bore in repairs
S&F in repairs 2 way angle cock double handle with flange 15 mm bore (for iron pipe) cast copper alloy fancy type chromium plated screwed down, complete all as specified and as direcetd by Engr-in-charge .
S & F in repairs 15 mm dia bore stop valves cast copper alloy chromium plated fancy type with long shank & cup (concealed type) complete all as specified and as directed.
S & F in repair PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed.
S&F in repair vitreous china squatting pan “ORISSA PATTERN” size 580mmx440mm ‘white’ with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe) including seat cover with CP screw complete all as specified and as directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position completein all respect as specified.
S&F in repair cast copper alloy chromium plated jet spray for EWC complete all as specified and as directed.
S& F in repair water closet seat, white closed pattern with flat bottom & cover & mild steel chromium plated hinging device complete all as specified and as directed.
S&F in repair vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed.
S&F in repair PVC connection 15 mm dia and 450 mm long with both end brass fly nut complete all as specified and as directed.
Supply and fixed in repair 15 mm dia bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and flynuts, screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type mixer pillar tape for cold & hot water complete all as specified and as directed.
S&F in repair 32 mm bore of pipe low density (LDPE) of pressure rating 6 kg/ sqcm fixed to wall or floor etc including fittings complete all as specified and as directed.
S&F in repair 32mm dia waste fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
S&F in repair PVC bath room cabinet with mirror of size 432 mm x 311 mm complete all as specified and as directed.
S&F in repair stainless steel kitchen rack plate rack over all size 24" x30"x10" inch complete all as specified and as directed.
S&F in repair stainless steel kitchen rack plate rack over all size 30" x36"x10" inch complete all as specified and as directed.
S&F in repair kitchen sink with drainage board made out of 1mm thick stainless steel with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever bracket and connecting union to pipe over all size 915 mm X 460 mm & bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S&F in repair brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S&F in repair toilet paper holder chromium plated fixed to wall with chromium plated brass screw complete all as specified and as directed.
S & F in repair 125 mm fancy type shower roses brass chromium plated with C P arms for15mm bore GI pipe.
S&F in repair CP soap tray fixed to walls with rubber plugs complete all as specified and directed.
S & F in repair fancy alumimum powder coated Drapery rod 25mm dia fancy powder coated.including MS bracket,side knob,corner bracket etc complete all as specified
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge.
S&F Anodised aluminium snap grid frame work (600mm x 600mm) for false ceiling complete all as specified and directed by Engr-in-charge.
S&F 12 mm thick Perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site complete all as specified and directed by Engr-in-charge.
Dismantling of AC/CGI/Fibre glass sheet corrugated/ semi corrugated sheet & ridge in roof covering complete all as specified and directed by Engr-in-charge.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (Unreinforced) in ground floor & paving n exc 15 cm thick (below or above ground level) complete all as specified and directed by Engr-in-charge.
M&L for 100 mm thick Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base floor complete all as specified and directed by Engr-in-charge.
M&L for machine pressed glossy coloured rubberisd moulded precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 to 60 mm thickness M-35 grey cement and pigment including laid over 25 mm thick layer of sand cushioning complete all as specified and directed by Engr-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required including demolishion of kerb stone complete all specified and directed by Engr-in-charge.
M&L for 100 mm thick Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base floor complete all as specified and directed by Engr-in-charge.
M&L for 10 to 12 mm thick vitrified unglazed and unpolished, scratch resistant, matt finished coloured tiles (square/ rectangular) of size not less than 300mmx300mm as in parking /hardstanding etc including set, jointed in cement slurry and pointed in white or coloured cement to match the colour/shades of tiles over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed by Engr-in-charge.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes channels plates etc including welding grinding buffing polishing and making curcature (where ever required and fitting the same with necessary stainless steel nuts and bolt complete including fixing the railing with necessary stainless steel nuts and bolts complete including fixing the railing with necessary accessories &stainlesss steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr in Charge
S&F in repairs of Venetian blinds, vertical type, 100 mm wide with polyester fabric of approved colour and pattern with aluminium fittings, and top rail and nylon buttons/loops etc fixed cuttings and alteration if necessary where ever AC/ coolers exists complete all as specified and directed by Engr-in-charge.
S&F in repairs of 18 mm solid PVC ply of 1st quality of approved colour and fixed with screw, solvent cement/ adhesive complete all as specified and directed by Engineer-in-charge.
S&F in repairs of 18 mm solid PVC ply of 1st quality of both side white colour fixed with screw, solvent cement/adhesive complete all as specified and directed by Engr-in-charge.
S&F in repairs of 12 mm solid PVC ply of 1st quality of both side white colour fixed with screw, solvent cement/adhesive complete all as specified and directed by Engr-in-charge.
S&F Aluminium anodised 100 mm long Butt hinges with galvanised mild steel screws complete.
S&F Aliminium anodised barrel tower bolts, 150 mm long complete all as specified and directed .
S&F Aluminium anodised handles, cast type anodised 125 mm long complete all as specified and directed .
M&L in repair for fixing of Aluminium composite panel of 3mm thick fixed on wall as wall paneling with making grid of 1200mm X1200mm of MS square pipe of size 25mmx25mm of 4mm thick fixed complete all as specified and directed by Engr-in-charge. Note : Pattern/design and color shall be approved by Accepting Officer. No Extra shall claim by the contractor for same. Note : Necessary scafolding rate deemed to be included in same item
S&F in repair PVC wall lining joint free consisting of 5mm thick colur PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing. Note : Pattern/design and color shall be approved by Accepting Officer. No Extra shall claim by the contractor for same.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
FUTURE ENGINEERING (BID ID -3099817)
Bee Kay Engineers & Contractors (BID ID -3100223)
M/S S.K.Electricals (BID ID -3115969)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .