| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.7 LAccepted-AOC 139 3 A PO KHAGRA DIST MURSHIDABAD PIN 742103 | KHAGRA | MURSHIDABAD | WEST BENGAL | 742103 | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹67.5 L+₹7.8 L (13.1%)Accepted-AOC 85 KALNA ROAD BURDWAN | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | L2 | Accepted-AOC Quoting Lowesr Rate | |
| 3 | L3₹68.1 L+₹8.4 L (14.1%)Rejected-Finance 2 9 SUNITY CHATTERJEE PATH CITY CENTER DURGAPUR DIST PASCHIM BARDHAMAN | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713216 | L3 | Rejected-Finance Quoting Higher Rate | |
| 4 | L4₹68.4 L+₹8.7 L (14.6%)Rejected-Finance NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L4 | Rejected-Finance Quoting Higher Rate | |
| 5 | L5₹68.5 L+₹8.8 L (14.7%)Rejected-Finance 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L5 | Rejected-Finance Quoting Higher Rate |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
29 May 2020, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Enginee
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Repairing and Renovation of Academic Building of Nurshing Training School and Hostel under Burdwan Medical Colege and Hospital, Purba Bardhaman EI WORK
2020_WBPWD_282737_1
WBPWD/SEWEC /BED /NIQ-01/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Bardhaman
Please refer tender documents
4 documents required · 4 mandatory
₹1.6 L
Office of the Superintending Engineer, Western Ele
26 Aug 2021
11 May 2020
1 Jun 2020
11 May 2020
29 May 2020
19 May 2020
11 May 2020 - 18 May 2020
18 May 2020
120 days
Amount
Supply & Installation of cubicle type compartmentalised dust & vermin proof panel board of suitable size made of 16 SWG thick M.S sheet reinforced with (40X40X6mm) flat/angle iron frame as required with individual hinged door with locking arrangement for all compartment & providing suitable ventilation arrangement & powder coating RAL7032 & earthing by nut & bolt in the body complete with base chanel. The lower side of the base of panel should rest on the frame work(75mm X 40mm X 5mm). The panel will have suitable cable alley on rear side of the panel. Panel Builder should have type test report for 50KA short circuit for 1 sec from CPRI with tinned coper bar with proper colour coded PVC sleaves. The panel comprises of the following breakers/switches. (Before pannel fabrication ---an autocad drawing of the pannel mustbe submitted approval to the EIC)
INCOMER :-
(a) S&F of 415V 400A TPN SFU with 3nos 400 A HRC fuses on angle - 01 no (Make L&T/Siemens/ABB).
(b) Bus Bar chamber: 630 Amp capacity (50mm x 5mm) 4 bar electrolytic tinned copper bus bar 99.99 % pure mounted on non hygroscopic porcelain insulator / hylemp sheet having sufficient di- electric strength duly wrarpped with colour PVC tapes Reds, yellow,blue,and black and for phases and neutral identification
OUTGOING :-
(a) S&F of 415V 250A TPN SDFU with 3 nos 250A HRC fuses - 1 no (Make L&T/Siemens/ABB).
(b) S&F of 415V 250A TPN on load front operated changeover switch - 1nos (Make L&T/Siemens/ABB).
(C) S&F of 415V 160A TPN SDFU with 3 nos 160A HRC fuses - 1 no (Make L&T/Siemens/ABB).
(d) S&F of 415V 160A TPN on load front operated changeover switch - 1nos (Make L&T/Siemens/ABB).
(e) S&F of 415V 100A TPN SDFU with 3 nos 100A HRC fuses - 4 no (Make L&T/Siemens/ABB).
(f) S&F of 415V 63A TPN SDFU with 3nos 100A HRC fuses - 2 nos (Make L&T/Siemens/ABB).
Supply & Installation of cubicle type compartmentalised dust & vermin proof panel board of suitable size made of16 SWG thick M.S sheet reinforced with (40X40X6mm) flat/angle iron frame as required with individual hinged door with locking arrangement for all compartment & providing suitable ventilation arrangement & powder coating RAL7032 & earthing by nut & bolt in the body complete with base chanel. The lower side of the base of panel should rest on the frame work(75mm X 40mm X 5mm). The panel will have suitable cable alley on rear side of the panel. Panel Builder should have type test report for 50KA short circuit for 1 sec from CPRI with tinned coper bar with proper colour coded PVC sleaves. The panel comprises of the following breakers/switches. (Before pannel fabrication ---an autocad drawing of the pannel mustbe submitted approval to the EIC)
INCOMER :-
(a) S&F of 415V 250A TPN SFU with 3nos 250 A HRC fuses on angle - 01 no (Make L&T/Siemens/ABB).
(b) Bus Bar chamber: 400 Amp capacity (30mm x 5mm) 4 bar electrolytic tinned copper bus bar 99.99 % pure mounted on non hygroscopic porcelain insulator / hylemp sheet having sufficient di- electric strength duly wrarpped with colour PVC tapes Reds, yellow,blue,and black and for phases and neutral identification
OUTGOING :-
(a)S&F of 415V 125A TPN SDFU with 3 nos 125A HRC fuses - 5 nos (Make L&T/Siemens/ABB).
(b)S&F of 415V 63A TPN SDFU with 3 nos 63A HRC fuses - 1 nos (Make L&T/Siemens/ABB).
(c)S&F of 415V 32A TPN SDFU with 3nos 32A HRC fuses - 2 nos (Make L&T/Siemens/ABB).
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ ABB/ L&T/ Schneider)
i) 8 way Enclosure up to 160A
ii) 4 way Enclosure up to 160A
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ ABB/ L&T/ Schneider)
i) 4 way Enclosure
Supplying and fixing 240/415 V FP MCB Isolator on din rail of existing DBs and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/ ABB/ L&T/ Schneider)
2+12 way Enclosure
Supplying and fixing 240/415 V DP MCB Isolator on din rail of existing DBs and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ ABB/ L&T/ Schneider)
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. 415A DIN type HRC fuse as per rating. [Make: L& T/Siemens/ABB]
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. 32A DIN type HRC fuse as per rating [Make: L& T/Siemens/ABB]
Supplying and fixing 415V, 32A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. 32A DIN type HRC fuse as per rating [Make: L& T/Siemens/ABB]
Supplying & fixing sheet metal (16 SWG) 415V,100A 4 copper bar Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required. Dimension of Cu. Bars: 4 x 15x3mm Dimension of Sheet Metal Box: 500x150mm
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC polythene pipe embedded in wall 'FR' (Precision make) incl. necy. fittings as required [Make:- Finlolex/ KEI/ Polycab]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
i) 2.5 sq mm
ii) 4.0 sq. mm.
iii) 6 sq mm
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [only PVC Rigid Conduit on ceiling] [Make- Finlolex/ KEI/Polycab]
i) Average run 8 mtr
ii)do-do-on board 6A modular plug point [E-20/ 3]
Supply/Delivery 250 volt. 4 Ft. Long 22 Watt LED fittings complete with all accessories (Make: Philips /Crompton/Wipro/Bajaj as per direction of EIC).
i) TMC 501P 1xT-LED 22W P3241 with 01 nos MAS LEDtube 1200mm 18W865 T8 I – 2100lm or equivalent of others make as per direction of EIC
ii) TMC 501P 2xT-LED 22W P3242 with 02 nos MAS LEDtube 1200mm 18W865 T8 I – 2100lm or equivalent of others make as per direction of EIC
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. { or “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamp } as required
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & delivery of 9W round B22 LED bulb. (Make: Philips /Crompton/Wipro/Bajaj as per direction of EIC).
S & D of ceiling fans (make - Orient summer king/ Usha Striker/ C.G. Zapar as per direction of EIC) of following dimensions: 48''
S & D of ceiling fans (make - Orient summer king/ Usha Striker/ C.G. Zapar as per direction of EIC ) of following dimensions: 56''
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Fixing only fan clamp for RC ceiling as per specification after cutting the ceiling & binding with reinforcement and mending good the damages.
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop.
S & F sweep A.C. exhaust fan (EPC/ Crompton - heavy duty) after cutting holes in the wall and making good the damages and smooth cement finsh etc. as practicble as possible and providing necy length of PVC insulated Cu wire and making connections.
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mmdia x 62 mm long) Aluminium
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 240 V industrial type 12 inch bell on HW board incl. S&F HW board
S & F bulk head light fitting (Make: Philips /Crompton/Wipro/Bajaj as per direction of EIC). with die cast aluminium housing & frosted glass on wall/ceiling incl.(EnduraLED- WT202W LED6S NW PSU S2 PC))
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size 10 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat40 mm x 6 mm on wall having clearance of 6 mm from wallincluding providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required
Supply & Fixing 240 V, 2 nos. 6 A, 5 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC), on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 1 nos. 16 A, 6 pin Modular type plug socket with 1 nos. 16A Modular type switch (Brand approved by EIC), on 3 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 1 nos. 16 A, 6 pin Modular type plug socket with 1 nos. 16A Modular type switch (Brand approved by EIC), with 3 nos. 6 A, 5 pin Modular type plug socket with 3 nos. 6A Modular type switch (Brand approved by EIC) 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with plug top and switch, on GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & laying of 1.1 KV. Gr. armored XLPE Al. LT cable of following rating on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting for connection from meter loop to LT main panel, from LT panel to VTPN as reqd. as per GS. [Make: KEI/ Polycab/ Gloster]
a) 4 core X 16 sq. mm.( for pump panel)
b) 4 core X 25 sq. mm.( for TPN)
c) 4core X 50 sq.mm. ( for VTPN)
d ) 2 X (3.5 core X 95sq.mm.)( for SUB PANEL)
e) 2 X (3.5 core X 185sq.mm.)( for MAIN PANEL)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables.
a) 4 core X 16 sq. mm.
b) 4 core X 25 sq. mm.
d) 4core X 50 sq.mm.
f) 3.5 core X 95sq.mm.
h) 3.5 core X 185sq.mm.
Finishing of the XLPE/PVC insulated armoured cable ends by crimping method with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
a) 4 core X 16 sq. mm.
d) 4 core X 25 sq. mm.
e) 4core X 50 sq.mm.
g) 3.5 core X 95sq.mm.
h) 3.5 core X 185sq.mm.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support.
150x50x1.25mm (18SWG)
300x50x1.25mm (18SWG)
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain nsulator, one compression type brass cable gland for upto 4- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Supply & delivery of 170W LED Street light (IP 66 protected) suitable for mounting from the top floor of the building with G.I. pipe. [Make: Philips/ Crompton - LSTP-120CDL-M/ WIPRO/Bajaj as per direction of EIC]
Fixing outdoor type LED light fitting on pole arm including making necy. connections as per direction of EIC.
Supplying & laying of 1.1 KV. Gr. armored XLPE Al. LT cable of following rating on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting for connection of loop wiring complete with necessary gland and terminator as per GS. [Make: KEI/ Polycab/ Gloster]
a) 4 core X 6 sq. mm.
Supply & erection of 1.5 Mtr. Long 80 mm dia G.I. Pipe pole (ISI - M) with pole cap & base plate in C.C. (6:3:1) foundation of dimension 600 x 600 x 750 mm having on the roof of the building after chiping of the roof incl. 3 mm thick net cemented finish and providing G.I. earth bolt after making drilled hole etc. on pole & painting as per G.S.
S & F single arm header fabricated with 100 mm dia G.I pipe 10'' length welded with 1.5 mtr long 40 mm dia G.I pipe at an angel 95 to 97 to with pole incl S & F nuts , bolts,washers nuts etc. & painting to G.S
Supply and Installation of Single Output Time Switch comprising 40A TPN MCB as incommer and 1 Channel Digital time Switch ( Make: L&T -AUTS02DIG00 ) the following with 1 NO TP Contractor ( Make:L&T, MNX 32 ) after cutting the wall and mending good the damages to original finish incl. necessary interconnection as per direction of EIC.
S & Delivery of Glowsign board febricated with 25 x 25 x 6 mm M.S angle and 25mm x 6 mm M.S. flat. Front side of the board making arrangement for hinged type door with locking arrangement made with M.S.angle incl. provision for fixing the Poly carbonate sheet facia approved colour ( 3 mm thick ) with computerised lettering in blue base white lettering rigidly fixed on angle iron frame and 25 mm x 25 mm Al. angle with nuts bolts washer etc.for fixing the facia.Bake side incl. rest four side of the board cover with 20 SWG Al. sheet.The facia should be illuminated with 4 fit long 18/20 watt F.L fittings (LED) required nos incl making arrangement for fixing the board incl. painting the inside of the board by shanthetic enamelled white colour paint as per direction of E.I.C.(As per approved matter by authority)
i) 10 ft x 4 ft 1st Board
S & F Lightning conductor Air-terminals made of 15 mm dia 1500mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI(Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate atbottom incl. necessary holes etc. duly grouted on the parapet etc.in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles and ceramic insulator 1100mm apart incl. mending good the damages to building works
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on Wall with GI Saddles & ceramic insulator 1000mm apart incl. mending good the damages to building works
Supply & fixing earth busbar of galvanized(Hot Dip) MS flat 25 mm x 6 mm incl providing drilled holes on the busbar complete with GI bolts,nuts,washers,spacing insulators etc as reqd.
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (HotDip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA Medium GI pipe
Making soldered joints between conductors and down pipes/other metallic objects for 14 SWG GI (Hot Dip) wire includingsupply of necessary 4 SWG GI (Hot Dip) wire, jointing materialsand painting with 2 (two) coats of bituminous paint .
Excavation of soil for installation of Earth Electrode and filling & ramming. ( for soft soil)
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Dismanetting of all old electrical installatio work and carrying the same material as per direction of EIC
M S CITY ELECTRICAL CO
SUBIR ENGINEERING WORKS (P) LTD
SREE GURU ENGINEERING
CHANDA CONSTRUCTION
SHANKAR BHATTACHARJEE
stage.html
html • 0.06 MB
technical_523706.pdf
PDF • 0.08 MB
techsummary_523706.pdf
PDF • 0.09 MB
finance_523706.pdf
PDF • 0.11 MB
BOQ Comparative Chart
xlsx • 0.03 MB
finsummary_523706.pdf
PDF • 0.10 MB
AccepSubrata.PDF
PDF • 0.10 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .