Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.0 LAccepted-AOC | ₹51.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹53.6 LRejected-Finance | ₹53.6 L | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | RAHUL L1 | M J ENGINEERING CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00Construction of Additional Hall in Konam Knowledge Center | |||||
| 1.01 | Dismantling ,clearing away and carefully stacking materials useful for re-use for any thick ness of walls.Dismantling of Reinforced Cement Concrete | 3 | m3 | 4,590.2 ₹13,770.60 | 4,840.83 ₹14,522.49 |
| 1.02 | Dismantling ,clearing away and carefully stacking materials useful for re-use for any thick ness of wallsDismantling of Weathering Course and Press Tiles | 141 | m2 | 49.05 ₹6,916.05 | 51.66 ₹7,284.06 |
| 1.03 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(a) Column | 120 | m2 | 649.8 ₹77,976 | 693.37 ₹83,204.40 |
| 1.04 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(b) Beam & Slab | 585 | m2 | 1,067 ₹6.2 L | 1,136.84 ₹6.7 L |
| 1.05 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).. -First Floor | 53 | m3 | 8,392.9 ₹4.4 L | 8,805.68 ₹4.7 L |
| 1.06 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials)..Second Floor | 13 | m3 | 8,685 ₹1.1 L | 9,097.46 ₹1.2 L |
| 1.07 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. | 7,590 | kg | 93.05 ₹7.1 L | 97.62 ₹7.4 L |
| 1.08 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 8 3/4"X4 1/4" X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT-First Floor | 29 | m3 | 6,735.9 ₹2.0 L | 7,076.69 ₹2.1 L |
| 1.09 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 8 3/4"X4 1/4" X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT-Second Floor | 27 | m3 | 6,925 ₹1.9 L | 7,273.43 ₹2.0 L |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
20 Nov 2025, 3:00 pmClosed
Commissioner Nagercoil City Municipal Corporation
City Municipal Corporation Office Nagercoil 629001 Ph.No. 04652230984
Nagercoil Corporation Construction of Additional Hall in Konam Knowledge Center at Konam
2025_MAWS_620377_1
06/2025-26/CE
Open Tender
Civil Works
90 days
Nagercoil Corporation Construction of Additional
Registered Contractor
4 documents required · 4 mandatory
₹0
₹64,000
15 Dec 2025
6 Nov 2025
20 Nov 2025
6 Nov 2025
20 Nov 2025
6 Nov 2025
Amount
Construction of Additional Hall in Konam Knowledge Center
Dismantling ,clearing away and carefully stacking materials useful for re-use for any thick ness of walls.Dismantling of Reinforced Cement Concrete
Dismantling ,clearing away and carefully stacking materials useful for re-use for any thick ness of wallsDismantling of Weathering Course and Press Tiles
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(a) Column
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(b) Beam & Slab
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).. -First Floor
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials)..Second Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 8 3/4"X4 1/4" X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT-First Floor
Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 8 3/4"X4 1/4" X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT-Second Floor
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Wiringwith2x1.5sq.mm.PVCinsulatedsinglecoreunsheathedFRLScopperconductorcableof1100VgradeinsuitableheavygaugeMSconduitpipeonwallandceilingwithMSaccessorieswithMSswitchBoxand5AFTswitchwithpaintingofsuitablecolourcontinuousearthwireconnectionof1.5sq.mmcopperwireforlightpoint/fanpoint(forelectronic regulator)
Wiringwith2x1.5sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetcoverfor5A3pinnoninterlockingwallsocketwith5Aflushtypeswitchwithcontinuousearthwireconnectionof1.5sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolour for concealed PVC plug point SD 38
Wiringwith2x4sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorcableof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetfor15A3pinnoninterlockingwallsocketwith15Aflushtypeswitchwithcontinuousearthwireconnectionof4sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolour for concealed power plug point SD 40
Supplyandfixingof1200mm(48")sweepACceilingfancompletewithsteppedelectronic300Wregulatorwith1metre down rod with fan clamp with side plates and cross arm of size 450mm (18") SD 106
18W LED 3000K Square Type Recessed Fitting with LED
Supply and Fixing of Wall Mounting Fan-400mm sweep
M J ENGINEERING CONSTRUCTION (BID ID -1516618)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_741851.xls
BOQ • 0.29 MB
Technical-Bid-06.pdf
Tender Documents • 0.65 MB
Download all tender documents and submit your bid