Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹34.4 L Quoted ₹34.9 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹39.4 L+₹4.5 L (13.0%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹39.4 L+₹4.5 L (13.0%) | L2 | Rejected-Finance rejected being L2 |
| 3 | L3₹47.0 L+₹12.2 L (34.9%)Rejected-Finance | ₹47.0 L+₹12.2 L (34.9%) | L3 | Rejected-Finance rejected being L3 |
| 4 | L4₹48.0 L+₹13.1 L (37.5%)Rejected-Finance | ₹48.0 L+₹13.1 L (37.5%) | L4 | Rejected-Finance rejected being L4 |
| 5 | L5₹48.8 L+₹13.9 L (39.7%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | ₹48.8 L+₹13.9 L (39.7%) | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
29 May 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIRS MAINTENANCE OF WINDOW TYPE ACs SPLIT TYPE ACs DEHUMIDIFIERS COLD STORAGE REFRIGERATORS WATER COOLER GEYSERS INCLUDING INTERNAL ELECTRIFICATION AT DFRL MYSORE
2021_MES_437115_1
8134
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D c (i)
9 documents required · 9 mandatory
₹5
Yes
GE I R AND D East Bangalore
₹94,000
Yes
25 Jun 2021
19 Apr 2021
31 May 2021
19 Apr 2021
29 May 2021
24 May 2021
20 Apr 2021 - 30 Apr 2021
Amount
Material and Labour for servicing of spilt type AC indoor/outdoor of capacity 1.5/2.0 Ton of any make and type including following item of works:
(a) Cleaning of complete unit including cooling coil condenser, Fan(Outdoor unit), blower, etc as directed by Engineer-in-Charge.
(c) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (d) Checking of refrigerant piping and carrying out necessary repairs/replacement to copper tubing and insulation to copper tubing.
(d) Checking of all components/accessories for their serviceability and replacement of defective components/accessories
(e) Greasing and oiling of fan motor
Note: (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items.
Supply & fixing new filter drier for 1.5TR Split type AC.
Supply & fixing for new Air filter for 1.5TR Split type AC.
Supply & fixing remote for 1.5TR Split type AC.
Supply & fixing remote for 2.0TR Split type AC.
Repairs to remote mother PCB for 1.5TR Split type AC.
Repairs to remote mother PCB for 2TR Split type AC.
Material and Labour for servicing of Window AC 1.5TR capacity including following items of works.:-
(a) Cleaning of complete unit including cooling coil condenser, Fan(Outdoor unit), blower, etc as directed by Engineer-in-Charge.
(b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc.
(c) Changing of all components/accessories for their serviceability and replacement of defective components/accessories.
Note:. (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items .
(ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer as directed by Engineer-in-charge functionality of AC is deemed to be included in unit rate
Supply and fix in repairs compressor (sealed unit) of capacity 1.5 Ton suitable for installed in Window type Air conditioner all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs compressor (sealed unit) of capacity 1.5 Ton in exchange of unserviceable suitable for installed in 1.5 Ton Split type Air Conditioner all as specified and as directed by Engineer-in-Charge.
Supply and replacement of compressor (sealed unit) of capacity 2.0 Ton in exchange of unserviceable suitable for installed in 2.0 Ton Split type Air conditioner all as specified and as directed by Engineer-in-charge.
Supply and replacement of compressor (sealed unit) of capacity 3.0 Ton in exchange of unserviceable suitable for installed in 3.0 Ton Split type Air conditioner all as specified and as directed by Engineer-in-charge.
Supply and fix in repair Running capacitor 36 MFD 230 volts, 50 Hz.
Supply and fix in repair Running capacitor 45 MFD 230 volts, 50 Hz.
Supply and fix in repair Starting capacitor 100 to 120 MFD 230 volts, 50 Hz.
Supply and fix in repair of relay suitable for Window type AC 1.0/1.5/2.0 ton capacity.
Supply and fix in repair of relay suitable for split type A/C of capacity 1.5/2.0 TR.
Taking down perished unserviceable insulation cover of refrigerent piping and supplying and fixing brutile rubber insulation for refrigerant pipings of suitable size
Supplying and fixing in repairs copper refrigerant pipe copper tube 5/8' x 3/8'.
Supplying and fixing in repairs copper refrigerant pipe copper tube 1/2'' x 1/4''.
Supplying and fixing in repairs copper refrigerant pipe copper tube 5/8'' x 1/4''.
Supply and fix in repair of Thermostatic switch with knob suitable for window type AC 1.0/1.5/2.0 TR.
M&L dismanling of window type / Split type AC from its own position and refixing the same in other location safely including making connection and testing complete all as specified and directed.
M&L for removing the split type air conditioner outdoor unit / indoor unit from its position for pressure / leak testing and arresting the leakages in condenser coil / cooling coil by brazing etc and gas charging as per required bases complete for split type AC 1.5 ton / 2.0 ton / 3 TR.
Supply and charging refrigerant gas R-12 / R22
Disconnecting and taking down unserviceable internal wiring of window / split type air conditioner up to 3 TR capacity and supply and rewiring complete with copper conductors complete including testing and commissining all as specified and as directed.
Supply and fix in replacement of outdoor condensing unit of split type AC 1.5/2 TR capacity all as specified and directed.
Supply and fix contactor 240 V up to 32 A suitable for window / split type AC capacity up to 3.0 TR including dismantiling of existing contactor complete all as specified and as directed.
Dismantling unserviceable cooling coil from 1.5/2/3 TR capacity split AC carefully without damaging the other parts supply and fix new cooling coil made out fro seamless hard copper pipe including brazing and pressure testing dy nitrogen gas including charging of R-22 refrigerant gas testing, commissioning etc.
Removing old rusted outdoor unit split air conditioner stand upto 2 TR from the existing site and supply and fix new stand made out mild steel as per existing without distrubuting / damgae the copper piping etc all as per specified and directed.
Supply and fix in repair suction and discharge valve for 1.5/2.0 TR spilt type A/C
Supply and replacement Capacitor 4 MFD, 230 volts, 50 Hz.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.0/1.5/2.0 TR Window type Air Conditioner of various makes as per sample.
Supply and fix in repair of Fan motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner of various makes as per sample.
Supply and fix in repair Fan motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner 0f various makes as per sample.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR split type Air Conditioner (indoor unit) as per sample.
Supply and replacement of Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 ton split type Air Conditioner (indoor unit) as per sample.
M & L for Rewinding of electric fan motor of 1.0/1.5/2.0 ton window type AC 1400 RPM 220 V 50 C/S with super enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
M & L Rewinding of electric fan motor of 1.5/2 ton split type AC (outdoor unit) 1400 RPM 220 V 50 C/S with supper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
Supply and fixing of new swing motor for split type AC 1.5/2.0 Ton capacity.
Supply and fix in repair of front grill suitable for 1.0/1.5/2.0 ton window type Ac make Carrier Air con/Usha Sriram/LG all as per site requirement and as per sample.
Supply and in repair of Plastic filter for window type AC 1.0/1.5/2.0 ton capacity.
Supply and fix in repair new Air filter for 2.0 TR Split type AC.
Supply and fixing in replacement of MCB SP 240 volt 32 Amps ABB /Siemens/Scheinder
Supply and replacement of PCB suitable for 1.5/ 2 ton split type AC,s as per site requirement and as per sample. Make : LG/Carrier/Blue star
Supply and replacement of fan blade suitable for out door unit of Split type AC capacity 1.5/2.0 as per sample .
Supply and replacement of fan blade suitable for window type AC capacity 1.0/1.5/2.0 as per sample .
Material and Labour for dismantling/taking out of water cooler for repair such as repair/replacement of compressor. fan motor. tank repair etc of any makes & size, from any place, and any capacity, transported to workshop & back, complete all as specified and directed (Repair work and replacement of damaged parts, incl MS work, shall be measured & paid separately).
Supply and replacement of Compressor ( Sealed unit ) suitable for 60/120 Ltr. Water Cooler make : Kirloskar / Blue star
Supply and fix in repair Fan Motor Single phase,230V for water cooler as per sample.
Supply and fix in repair Fan Motor blade as per sample all as directed
Supply and replacement of Push type C.P. bib cock for water cooler.
Supply and fix in repair float valve PVC for water coolers as per sample.
Supply and fix in repair water drain-out tary stainless-Steel ( thickness -0.71) for water cooler any make /size , with PVC waste pipe ,pipe clamp, complete as directed
Supply and fix in repair Running capacitor 25 MFD 230 volts, 50 Hz.
Supply and fix in repair Starting capacitor 60 to 80 MFD 230 volts, 50 Hz.
Supply and fix in repair over load relay suitable for Water cooler 40 t0 60 ltr. As per sample.
Taking out unserviceable compressor from refrigerator of capacity 310 / 280 / 165 ltr of any make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and fixing compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing / rectification of leakage
Note :- (i). supply and charging of refrigerant gas as per requirement complete all as specified and as directed(ii) compressor (sealed unit) shall be measured and paid separately (iii) Spare Parts required for replacement shall be paid and measured separately.
Supply and Charging of Freon gas-134/R-12 for Refrigerator/Water cooler and Deep Freezer .
Supply and replacement of Box type relay suitable for refrigerator 165 to 310 ltr capacity.
Supply and replacement of Evaporator coil assembly for refrigerator 165 to 310 Ltrs capacity
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity
Supply and replacement of freezer door for refrigerator 165 to 310 Ltrs capacity
Supply and replacement of flexible Core PVC insulated with stranded copper conductor 4 Sqmm 3 core 600/1100 V ISI Marked all as directed.
Material and Labour for Repairs to Voltage stabilizer of 1 KVA to 5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit plate, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay all as directed.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA all as specified and as directed.
S&F Relay 30 Amps capacity suitable for 4/5 KVA stabilizer.
Supply and fixing of new lamp for Deep Freezers 500 Ltrs
Supply and fixing of new lamp cover for Deep Freezers 500 Ltrs
Supply and fixing of new lamp switch for Deep Freezers 500 Ltrs
Supply and fix low and high pressure cut out complete all as specified and as directed. Make: Indofoss / Danfoss
Supply and fix in replacement temperature controller suitable for cold storage plant upto 4 (+/-2) degree celsius complete all as specified and as directed. Make: Rinak all as per sample
Supply only company reconditioned compressors as per sample, suitable for cold storage plant upto 4 (+/-2) degree celsius and of capacity 20000 BTU complete all as specified and as directed.
Supply only company reconditioned compressors as per sample, suitable for walk in freezer plant upto -20 (+/-2) degree celsius and of capacity 20000 BTU complete all as specified and as directed.
Supply and fix heaters suitable for FRB 1800 Dehumidifiers including taking out U/S heaters etc all as per directed.
Supply and fix PVC drain pipes of 20mm bore with all accessories, clamped to wall / ceiling with necessary clamps for draining out condensed water from indoor / outdoor units as required and directed at site.
Supply and fix timer suitable for FRT 1800 model dehumidifiers inclunding taking out U/S timer etc all as directed.
Supply and fix primary and secondary process filter suitable for FRB 1800 model dehudifiers including taking out U/S filters etc., all as directed.
Servicing of dehumidifiers of make BRY Air, model FRB 1800 after dismantling, opening of External Covers, opening and removal of Filtrer Bank, Heaters Banks and Gear Box. Cheking, cleaning and defect rectification of all internal parts for minor faults and replacement of same. Refixing all the dismandled accessories including testing etc., all as directed. Note: All the major spares parts will be measured and paid separately.
Repair to geyser including taking down geyser by emptying and removing nut bolts disconnecting electrically, making the dead weight on top of geyser free, cleaning of thermostat and heating element and repairs to container if required and refixing geyser in its position after repairs (spare required for repairs / replacement will be measured and paid separately under relevant items of work)
Supply only Geyser element 2 KW of approved make ISI marked all as specified and as directed.
Supply only Geyser element 1.5 KW of approved make all as specified and as directed.
Supply only thermostat of approved make as per sample all as specified and as directed.
Supply only thermal cut out of approved make as per sample all as specified and as directed.
Supply only Indicator lamp of approved make as per sample all as specified and as directed.
Taking down the ceiling fan/Exhaust fan of any size complete and refixing the fan with twin flexible cord wire from the ceiling rose and testing complete.
Painting of fan/Exhaust fan any type with 2-coats of enemelled paint after filling cavities complete all as specified.
Replacement of bearing of suitable size of ceiling fan/exhaust fan.
Replacement of bush of of suitable size of ceiling fan/exhaust fan.
Replacement of capacitor 2.5/4 MFD of ceiling fan/exhaust fan
Rewinding of fan with suitable guage of enemelled copper wire with suitable class of insulating varnish, of any size and sweep complete.
Taking down carefully existing copper / aluminium point wiring (Concealed / surface) light/fan, socket or power complete including fittings and fixtures such as switches sockets ceiling roses pendants regulators light fittings etc .
Material and labour for point wiring with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volt FR grade ISI marked with multistranded copper conductor drawn through existing conduit caping in wall / ceiling with and including provision of MS box of suitable size with 3 mm thick laminated hylam sheet cover for housing switch, socket, etc including provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following all as specified and as directed.
(a) One light point/fan point/bell point controlled by one 05 Amps switch.
(b) One socket out multi pin 5 Amps controlled by one switch on independent board.
(c) One socket out multi pin 5 Amps controlled by one switch on same board.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FR grade ISI marked with multistranded copper conductor drawn through and including PVC rigid conduit / PVC casing capping of suitable size in wall / ceiling, with and including provision of MS box of suitable size with 3mm thick laminated hylam sheet cover for housing switch, socket, etc with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for the following all as specified and as directed.
(a) One light point/fan point/bell point controlled by one 05 Amps switch.
(b) One light point controlled by Two Nos of 2 way switch 05 Amps.
(c) One switch socket combination 5 Amps on same board
(d) One switch socket combination 5 Amps on independent board
All as per item No 95 here in before but for one socket out let 2 in 1, 5 and 15 Amps with 4 Sqmm PVC copper conductor and provn of 4 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor.
Supply and fixing modular switch 6 Amps one way complete all as specified and as directed.
Supply and fixing modular switch 16 Amps one way complete all as specified and as directed.
Supply and fixing modular switch 6 Amps two way complete all as specified and as directed.
Supply and fix ceiling rose 2 to 3 terminal bakelite compelte all as specified and as directed.
Supply and fix angle/pedant/CG holder PVC with PVC square box complete all as specified and as directed.
Supply and fix bell push 250V, 6 amps complete all as specified and as directed.
Supply and fix socket 6 Amps multi purpose fluse type complete all as specified and as directed.
Supply and fix socket 2 in one, 5 and 15 Amps flush type complete all as specified and as directed.
Supply and fix call bell ding dong type complete all as specified and as directed.
Supply and fix regulator electronic step type humming free , 100 watts complete all as specified and as directed.
Taking down old unserviceable aluminium sub main wiring, material and labour for sub main wiring complete with 2 runs of 6 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including PVC non metallic rigid conduit/casing caping of suitable size and conduit accessories run on surface of wall / ceiling etc and connecting terminal ends including 1 run of 4 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth dolly complete all as directed.
All as per item No.107 above but sub main wiring complete with 2 runs of 4 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 1 run of 2.5 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor.
All as per item No.93 above but sub main wiring complete with 4 runs of 4 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 2 run of 2.5 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor.
All as per item No.107 above but sub main wiring complete with 4 runs of 6 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 2 run of 4 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor.
All as per item No.107 above but sub main wiring complete with 4 runs of 10 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 2 run of 6 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor.Note for item No 34 to 38 :- 4/2 runs of cable, one run of conduits / casing capping and one/ two runs of earth conductor shall be measured as one unit.
S&F in repairs MCB DB double door type single phase 04 way with 200 amps rated bus bar
S&F in repairs MCB DB double door type single phase with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts, 08 way
S&F in repairs MCB DB double door type single phase with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts, 12 way
S&F in repairs MCB DB double door type three phase with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts, 04 way
S&F in repairs MCB DB double door type three phase with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts, 06 way
Taking down/removing of unserviceable MCB DB TPN, supply and fixing of MCB DB TP with MCCB 16 KA 4 pole 100 amps as incomer,12 way with sheet metal enclosure double door type,complete with neutral , earth bus fixed on wall.
Taking down/removing of unserviceable MCB DB TPN, supply and fixing of MCB DB TP , 08 way with MCCB-63 amps 10 KA 4 pole as incomer, with sheet metal enclosure double door type,complete with neutral , earth bus complete.
Supply and fix in replacement 4 way DB SPN with MCB TPN 32 amps, C series , 10 KA, 415V
Supply and fix in replacement 4 way DB SPN with MCB TPN 40 amps, C series , 10 KA, 415V
Supply and fix in replacement 4 way DB SPN with MCB TPN 63 amps, C series , 10 KA, 415V
Taking down/removing of unserviceable main switch 3 pole 63Amps, supply and fixing of MCB TPN 63 Amps with sheet metal enclousre, fixed on hylam sheet of 3mm thick on wall
Supply and fix in replacement MCB SP 10 KA 250V, 'C' series of capacity 6-32 amps
Supply and fix in replacement MCB SPN 10 KA 250V,'C' series of capacity 10-32 amps
Supply and fix in replacement MCB TPN 10 KA 415V, 'C' series of capacity 32 amps
Supply and fix in replacement MCB TPN 10 KA 415V, 'C' series of capacity 40 amps
Supply and fix in replacement MCB TPN 10 KA 415V, 'C' series of capacity 63 amps
Supply and fix in replacement MCB TPN 10 KA 415V, 'C' series of capacity 100 amps
Supply and fix in replacement starter suitable for 36 / 40 Watts tube fittings make CG / Philips
Sreekrupa Enterprises
eurekaenterprises
Power and Telecom Systems
SUPER COOL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .