Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.8 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
1 Feb 2021, 5:00 pmClosed
RAJA NAGENDER SINGH
NIRMAN SADAN , 4TH FLOOR, CIVIL LINES , PWD B and R (Elect.)GURUGRAM
Construction of Swarn Jayanti Environment Training Institute at Manesar in District Gurugram (Providing Internal E.I. Street light and lifts).
2020_HRY_154172_2
PWD (Elect.) Dec. 2020
Open Tender
Electrical Works
Works
360 days
XEN(E) Gurugram
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.2 L
2 Sept 2021
20 Jan 2021
2 Feb 2021
20 Jan 2021
1 Feb 2021
20 Jan 2021
Amount
Wires and Cables, Supply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. Size 1.50 sqmm ( 48 / 0.20mm).
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Distribution board with plug and socket. Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp.
Blanking sheet . Supply and erection of blanking sheet in existing distribution board.
(L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
DP Isolator 40 amp.
(M) Supply and erection of Fittings and Accessories. Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20watts 610 mm long fluorescent tube with fittings by means of 2 Nos. , 20 mm diameter 1.60 mm thickness conduit pipe with spring loaded brass flanges at both ends including 0.75 sqmm (24/0.20 mm) PVC copper flexible cable for connecting the tube to the adjascent light point including cost of conduit pipe flanges . PVC flxible cable and petty material required for the same ( Upto 1/2 metre length of pipe ).
Erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
(O) Erection and carriage of fans. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
(P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 65 mm dia.
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) comlete as required.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Supplying and laying of 8 S.W.G. copper wire at 0.50 metre below ground level as conductor earth electrode including thimbles, soldering etc. as required .
Supply and erection of 20 mm x 3 mm thick copper tape fixed with suitable copper staples of same size.
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 16 Sq. mm 4 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
(X) Miscellaneous . Supply and erection of caution notice plate in three languages.
Supply and erection of shock restoration chart in glass frame
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm).
Cable size 2.5 sq.mm(3/ 1.05 mm)
Size 4 sqmm (7 / 0.85mm).
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 8 way SP&N (Horizontal)
8 way TP&N (Horizontal) (8 +24)
Supply and erection of double pole / Four pole Residual current circuit breaker ( RCCB / ELCB) suitable for operation on 240/415 V, 5 Hz. AC supply installed in existing sheet steel enclosure including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 25 A/240 V DP ELCB with 100 mA sensitivity
40 A/240 V DP ELCB with 100 mA sensitivity
63 A/240 V DP ELCB with 100 mA sensitivity
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. 20 mm dia
25 mm dia
Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect.
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect.. Call bell Ding-Dong ( Monitca )
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requiered to complete the job in all respect. 1 & 2 module
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. HDPE 90/75 mm outer dia / inner dia
S/E of Hot Dip Galvanized octagonal pole of 3 mm thickness, with base plate including cost of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. the foundation bolts as per manufacturer design should be hot dipped galvanized pole complete with door locking arrangement, Terminal plate consisting of 2 nos. 100 A, 4 pole natural links inclding connection etc. with suitable connecting arrangement for 2 nos. MCBs/ kit- kat including cost of RCC 1:1.5:3 for foundation of size 0.7 m x 0.7 m x 1.8 m with minimum 8 nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C. for fixing the pole with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer - In - Charge of the work. 7 Mtr. Long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12 mm
Supply and laying of multicore telephone cable conductor size 0.1 mtr. bright annealed copper conductor PVC insulated and sealed in existing pipe/ Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer -in- Charge of the work. 2 pair telehone wire
5 pair telehone wire
Supply & erection of cable tray made out of 2 mm thick galvanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. 40 x 100 mm
Supply & erection of factory manufactured cable tray cover made of the G.I. sheet complete with fastoner nuts bolts and in position including the petty material required to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. Suitable for 40 x 100 mm
Suitable for 50 x 150 mm
Suitable for 50 x 300 mm
PVC Insulated copper wiring in recessed MS conduit. Wiring for light point/ fan point/ exhaust fan point/ call bell point and 5 amp. plug point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed MS conduit with modular switch and socket, modular inner and outer plate, suitable GI box etc. with all labour, material, chasing, refelling of walls complete in all respect upto entire satisfaction of Engineer in Charge . Light Point/Exhaust fan Point Short Point
Medium Point .
Long Point .
Fan Point Point. Medium Point .
Long Point .
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell Long point
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point.
Medium point.
Long point.
3 pin 15 amp. plug point with 4 sq mm PVC insulated copper conductor cable including earthing the 3rd. pin etc. Long point
S/E of Modular Type junction box of size 75mm x 75mm with face plate and RJ connector suitable for connection of telephone wire with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work
Supplying and fixing modular type Information Outlet RJ-45, CAT 6 Data , front plate and suitable size metal box on surface or in recess including connections etc. complete as required.
Supply and erection of load line i.e. double door TPN vertical distribution board suitable for MCCB as incommer on existing angle iron board / on wall / in pedestal including making nacessary connection with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work. 8 way Double door TPN distribution board suitable for 100 amp. 4 pole MCCB but without cost of MCCB. (Make : Havell's /ABB/Schnider)
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON make suitable for 13 persons (884 kg. weight) having speed @ 1.5 meter per second to travel from basement + ground floor + 2 upper floors with 4 stops, 4 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON make suitable for 13 persons (884 kg. weight) having speed @ 1.5 meter per second to travel from ground floor + 2 upper floors with 3 stops, 3 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
Supplying, installing on wall, testing and commissioning of 200 amp. capacity sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as per IEC 61439-6 complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work
Supplying, installation, testing & commisioning of 200 amp. capacity End Feed Unit for the existing sandwich Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as per IEC 61439-6 complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work
Supplying, installation, testing & commisioning of 200 amp. capacity Plug In/ tap off box on the existing sandwich Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as per IEC 61439-6 complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work
Supply and erection of 60 watts LED street light fittng with lense IP 66, HP dia cast aluminium hoising including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
Supply and erection of 40 watts LED Gate Light fittng with lense IP 66, HP dia cast aluminium hoising including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
Supply and erection of IP 65 rated inverted pyramid tripod type LED bollard with soft 360 deg light distribution including erection of same on plinth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.
Supply and erection of single arm bracket made of 50 mm dia G.I pipe B class ISI 1.5 mtr. long with 25 mm dia G.I. bottom pipe with 75 mm dia 60 cm. long G.I. collar pipe, top covered with ornamental cap duly welded, painted 2 coats of aluminium paint on bracket and golden paint on ornamental cap including erection of same with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .