Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹27.8 L+₹3.6 L (14.7%)Rejected-Finance 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹28.8 L+₹4.5 L (18.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹30.4 L+₹6.1 L (25.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹30.7 L+₹6.5 L (26.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹37.1 L
EMD Value
₹74,200
Closing Date
4 Mar 2020, 5:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIRS TO JCOS QTR BUILDING NO P8 AND SPECIAL REPAIRS TO TYPE I QTR BUILDING NO P85 AT CQAE AUNDH CAMP PUNE UNDER GE MH AND RH KIRKEE
2020_MES_319481_1
CWE/KKE/45 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
Headquarters CWE Kirkee, Military Engineer Service
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE MH AND RH KIRKEE
₹74,200
Yes
31 Mar 2020
29 Jan 2020
7 Mar 2020
29 Jan 2020
4 Mar 2020
21 Feb 2020
29 Jan 2020 - 5 Feb 2020
Amount
Taking up or down 20mm bore carefully steel water tubing, and connections with fittings including cleaning for re-fixing or removal complete all as specified and as directed
Taking up or down 15mm bore carefully steel water tubing, and connections with fittings including cleaning for re-fixing or removal complete all as specified and as directed
Supply & laying 20mm bore GI tubing 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /ceiling including conceled and including clips, wall hooks etc, complete all as specified and directed
Fixing only 20mm bore GI tubing ISI marked of size 'medium grade' with and including all necessary new fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /ceiling including conceled and including clips, wall hooks etc, complete all as specified and directed (Note:-Old GI pipes as retrived from serial item No. 1 above in good condition shall be used)
Supply & laying 15mmm bore GI tubing 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /ceiling including conceled and including clips, wall hooks etc, complete all as specified and directed
Fixing only 15mm bore GI tubing ISI marked of size 'medium grade' with and including all necessary new fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /ceiling including conceled and including clips, wall hooks etc, complete all as specified and directed (Note:-Old GI pipes as retrived from serial item No. 1 above in good condition shall be used)
Supply, laying & fixing 20mm bore GI tubing 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in Trenches and complete all as specified and directed
Supply, laying & fixing 40mm bore GI tubing 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in Trenches and including clips, wall hooks etc, complete all as specified and directed (Note for Serial Item No.7 & 8 :- (i) Excavation and earth work, shall be measured and paid separately under respective item of BOQ.)
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying, GI pipes not exc 1.5m in depth & n.exc 10Sqm on plan and getting out in soft / loose soil.
Returning, filling, incl spreading levelling, watering and well ramming in layers not exc 25cm all as directed
Removing excavated material not exc 50m and depositing where as directed at a level not exc 1.5m above the starting point.
S&F in repairs Gun-metal, globe or gate valves 20 mm bore, ISI marked,with iron wheel head, screwed both end for iron pipe and fixed in repair complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves 40 mm bore,ISI marked with iron wheel head, screwed both end for iron pipe and fixed in repair complete all as specified and directed.
Dismantling water tanks capacity exc, 250 & n.exc 500 litres and removing from site, complete all as specified & directed.
Supply and fix 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layered 'ISI' marked, hoisted & fixed in position including provision of washouts, vent pipe, nipples of suitable size complete all as specified & directed.
S & F ball brass valve 20 mm dia high pressure with poly-thine float and fly nut , complete all as specified and directed.
Demolition of PCC block masonry built in cement or cement lime mortar, complete all as specified and directed.
M&L for precast cement concrete, 1:3:6 type C-1 (using 20mm graded aggregate ) masonary with solid blocks, exc, 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5sqm but not exceeding 4sqm complete all as specified and directed.
Taking down shutters of any description exceeding 1.0sqm and not exceeding 2.0sqm each complete all as specified and directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, guard bars dovetailed or welded, complete all as specified and directed .
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, guard bars dovetailed or welded, complete all as specified and directed .
S&F steel ventilator with top hung shutter including hinges steel peg stay, complete all as specified and directed .
S&F MS framed work such as grills, gratings etc; with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed .
S&F 3mm thick pin headed glass ordinary quality with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed
S&F 3mm thick obscured or frosted glass ordinary quality with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed
S & F pressed steel frames of size frame 105 x 60 mm made out of 1.25 mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. complete as specified all as directed.
S & F pressed steel frames of size frame 125 x 60 mm made out of 1.25 mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. complete as specified all as directed.
S&F 1.2 mm thick plain black sheet built in steel cupboard shutter(double leaf) , including complete fittings i.e. hinges,steel almirah handle 125mm/130mm long, locking assembly made out of mild steel rod and MS Flat as per existing shape and size suitable for almirah large with 6 lever lock godrej pattern with duplicate key complete all as specified and directed by Engr-in- Charge.
S&F in repair steel shelves made out of 1mm thick MS sheet all as specified and directed ( partition of steel cupboard .)
S&F 35 mm thick, flush shutters (confirming to IS) solid core construction, with block board core and plywood face panels, commercial type on both sides complete as specified all as directed.
S&F 30mm thick(2nd Class hardwood) factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze , etc (without sash bars) , edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass , etc, sizes of members of shutters as specified in SSR Part I , Section 8 , Clause 8.24 (a) , Supplied and fitted to chowkats complete all as specified and as directed.
S&F factory made Solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube,and fixing in opening as per manufacturer's instructions and complete all as specified and as directed by Engineer-in-Charge.
S&F factory made solid PVC moulded, door shutter 28 to 30 mm thick (stiles), with 2,4, or 6 raised panel design with 2 mm thick moulded prelam sheet on front face & 2 mm plain colour PVC sheet on back face complete all as per manufacturer's instructions and complete all as specified and as directed by Engineer-in-Charge.
S&F in Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm complete all as specified and directed
S&F aluminium anodised barrel tower bolts of extruded section, 150 mm length, ISI marked fixed with stainless steel screws complete all as specified and directed
S&F MS barrel tower bolts of Stove enamelled black with bright bolt, 150 mm length, ISI marked fixed screws complete all as specified and directed
S&F butt hinges, of size 100mm ,stainless steel medium weight ISI marked complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, 300 mm long , ISI marked. complete all as specified & directed.
S & F Mild steel sliding door bolt 300 mm long, plate type,stove enamelled black with bright bolt not less than 12 mm dia with and including, mild steel min of 6 bolts and nuts, 4 on bolt plate and 2 on stapleplate fixed/weldedto door shutter/frame complete all as specified & directed.
S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size, ISI marked fixed with stainless steel screws complete all as specified and directed
S&F mild steel pressed oval type handles stove enamelled black for doors 150 mm long complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removal of debris out side MD land at the location decided by the Engineer-in-charge complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing coat) removing serviceable tiles to store and removal of rubbish out side MD land at the location decided by the Engineer-in-charge complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished evern and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 10 mm thick on concrete surface in cement mortar (1 :4) as in ceiling etc. finished even and smooth (without using extra cement ) complete all as specified and directed.
M&L for providing 15 mm thick rendering set in CM (1:4) on fair faces of concrete/brick masonary surfaces finished even and smooth without using extra cement mixed with integral water proofing compound @3% by weight of cement complete as specified all as directed. (Note : WPC shall be measured and Paid separately).
Supply only integral water proofing compound, ISI marked.
M&L for Providing and carrying out water proofing treatment to toilet ,sunken slabs ,wet areas etc,after proper surface prepration, carry out cementitious ingection grouting at leakage point using Cebex 100 plasticised expandiv grouting admixture, application of polymer modified vatta at slab wall junction using Nitoband SBR latex screed modificer cum bonding agent and application ot two coats of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc,complete including all tools and tackles as per manufacturer's specification complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal of debris out of MD land at the location decided by the Engineer-in-charge complete all as specified and as directed.
M & L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in filling, mass concrete, for sunkun floor etc. complete all as specified and directed.
M&L for coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.36 sqm, in floors etc. over and including 15mm thick cement mortar (1:6) screed bed set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for coloured non-skid ceramic tiles, of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc set an jointed in neat cement slurry and pointed in white or coloured cement to match including laid over 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 300mm x 450mm x 7 to 8mm thick of colour and pattern as approved by GE, as in vertical surface, set and jointed in neat cement slurry using grey cement and pointed in coloured cement to match the colour of tiles over and including 10mm thick backing coat in cement mortar (1:4) etc including triangular filleting on top in cement mortar (1:4) complete all as specified & directed.
M&L for chequered cement concrete tiles 300mm x 300mm x 20mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry as in floors, cut and machine polished laid over and including 15 mm thick screed bed in cement mortar (1:6). complete all as specified and as directed.
M&L for Machine cut Kota stone slab flooring 20 to 25 mm thick in flooring/steps treads/slabs laid over and including 15 mm thick screed cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
M&L for Machine cut Kota stone slab flooring 20 to 25 mm thick but, as in skirting /Dado, set and jointed with grey cement slurry mixed with pigment to match the shade of kota stone slab including, rubbing and mirror polishing laid over and including 10mm thick backing coat in cement mortar (1:4). complete all as specified and as directed.
M&L for granite (of any type) slab, 18 to 20mm thick machine cut, bedded and jointed with grey cement and pointed with white cement and adhesive of pigment to match the shade of granite stone including griding and polishing etc complete over and including 10 mm thick cement mortar screed in (1:4). complete all as specified and as directed.
M&L for full rounding to edges of stone slabs one edge, such as in steps, cooking platform, shelves, and other similar situations complete all as specified and as directed.
S&F in repair ,stainless steel sink, 1mm thick, kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size, 915mm x 460mm & bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F plate rack made of stainless steel 1mm thick and overall size 915mm x915mm x 255mm, inlcuding taking down old /unsv complete all as specified and directed.
S&F in repairs powder coated aluminium pipe 20mm dia as in curtain rod fixed to brackets complete all as specified and directed. (Note : Brackets shall be measured and paid separately )
S&F in repairs powder coated aluminium brackets fancy type with adjustable threaded socket use for 20 mm internal dia drapery rod on each ends on doors and windows fixed with rowel plugs and cloured matching screws for curtain rods complete all as specified and directed
S&F in repairs tubular towel rail 20mm dia, D type 60cm long between flanges Aluminium anodised complete all as specified and as directed.
S & F in repairs stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed - bore dia of pipe 15 mm. complete all as specified and directed
S&F in repairs Bib taps, chromium plated brass with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and suitable for 15 bore of pipe fixed complete all as specified and directed
S&F in repairs Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified and as directed.
M&L for PCC (1:3:6) type C2, (using 40mm graded stone aggregate) 75 mm thick as in plinth protection finished even and smooth without using extra cement incuding use of necessry formwork complete all as specified & directed.
S&F in repairs wash hand basin vitreous china white (flat back) of size 550x400mm including, CI bracket, 32mm dia brass chromium plated (CP) waste coupling chain and plug porcelein stopper etc. complete all as specified and directed.
S&F in repair pillar taps for 15 mm bore dia of pipe, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair grating doom, 125mm dia with waste hole of PTMT(minimum weight 40 grams) complete all as specified and directed
S&F in repairs, vitreous china squatting pan Orissa pattern wash down water closet white of size 580x440 mm, white integral foot rests complete with P or S trap, (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc. including concrete bedding etc. complete all as specified and directed
S&F in repair PVC valveless syphonic action type flushing cistern (low or high level) of 10 ltr capacity, white or coloured with inlet, ball valve float, handle including fixing brackets and 32 mm bore PVC flushing pipe etc complete all as specified and directed (Make : CERA, Hindware or Equivalent as aprroved by GE)
M&L for providing cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate), as in coping hold fast block, bed bolck filling pressed steel door frame etc as directed including necessary formwork etc. complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for preparation of new untreated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for prepration of new plastered surfaces of walls and applying two coats of oil bound distemper of approved colour and pattern over a coat of primer over & including 3mm thick wall care putty finished even and smooth complete all as specified and directed.
M&L for prepration of new plastered surfaces of walls and applying three coats of white wash over & including 3mm thick wall care putty finished even and smooth complete all as specified and directed.
M&L for prepration of new plastered surfaces of ceilings and applying three coats of white wash over & including 3mm thick ceiling care putty finished even and smooth complete all as specified and directed.
M&L for complete removal of existing finishes by scraping down old decorative surface of Ceilings, with steel wire brushes of smoke spots, moulds, efflorescent salts , and applying three coats of white wash over & including 3mm thick ceiling care putty finished even and smooth on old surfaces of Ceilings complete all as specified and directed.
Taking down drain pipes (any size or pattern), including all fittings, T, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories) or removal to store complete all as specified & directed
Supply and fix for PVC (SWR) pipe 110mm bore single socketed with rubber ring joints/ adhesive fixed to walls with PVC clamps complete all as specified and as directed.
Refixing of old PVC (SWR) pipe 110mm bore single socketed with rubber ring joints/ adhesive fixed to walls with PVC clamps complete all as specified & directed.(Note:-Old pipes as retrived from Serial item No. 84 above in good condition shall be used)
Supply and fix for PVC (SWR) pipe 75mm bore single socketed with rubber ring joints/ adhesive fixed to walls with PVC clamps complete all as specified and as directed.
Refixing of old PVC (SWR) pipe 75mm bore single socketed with rubber ring joints/ adhesive fixed to walls with PVC clamps complete all as specified & directed.(Note:-Old pipes as retrived from Serial item No. 84 above in good condition shall be used)
M&L for PVC (SWR) bends of any radius of 110mm bore complete all as specified and directed .
M&L for PVC (SWR) bends of any radius of 75mm bore complete all as specified and directed .
S&F for PVC (SWR) junction 110mm bore single ( single T) equal or unequal complete all as specified and directed.
Refixing of old PVC (SWR) junction 110mm bore single ( single T) equal or unequal complete all as specified & directed.(Note:-Old junctions ( single T) as retrived from Serial item No. 84 above in good condition shall be used)
S&F in repairs PVC (SWR) junction 75mm bore single ( single T) equal or unequal complete all as specified and directed.
Refixing of old PVC (SWR) junction 75mm bore single ( single T) equal or unequal complete all as specified & directed.(Note:-Old junctions ( single T) as retrived from Serial item No. 84 above in good condition shall be used)
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified & directed.
Taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces etc. complete all as specified & directed.
Taking down unserviceable main switches ,DBs alongwith teak wood boards etc and making good disturbed surfaces of walls/ floors to match the existing surfaces, etc. complete all as specified & directed.
M&L for Point wiring complete with and including 1.5 sq. mm ( nominal area) single core multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLS-H, I S I marked drawn into & including concealed PVC Rigid Heavy Grade Non-metallic Conduit ISI marked suitable size thickness not less 1.5 mm with accessories such as bend ,tees, junction boxes etc. including 1.5 Sqmm PVC insulated and unsheathed flexible muliti stranded copper conductor FRLS -H, cable as continuous earthwire connected to metallic bodies of luminaries/fans etc. at one end and to common earth duly at other end including concealed MS terminal box with 3mm thick hylam sheet ISI marked suitable for for housing switch, socket and fan regulators etc complete and including making good of disturbed surfaces, matching the surface to the existing finishing colour all as specified and directed for the following:-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point controlled by one, one way switch 5 Amps
(c) One 5 Amps Socket outlet point flush type controlled by one switch on independent board.
(d) One 5 Amps Socket outlet point flush type controlled by one switch on same board
(e) Bell /buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 2.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded cable 1100 volts grade,ISI - 694 FRLS marked drawn into & including concealed PVC Rigid Non-metallic Conduit ISI marked suitable size thickness not less 1.5 mm with accessories such as bend ,tees, junction boxes etc.,including PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting chases in the wall for box including making good of disturbed surface and all as specified for 5 pin 16 Amps socket outlet on independent board.complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 6 Amp 250 volts,complete all as specified and directed
S & F socket outlet flush type, 3 pin 6 amps, multi purpose, 230 volts, single pole , suitable for 3-pin /2-pin 6 Amp plug tops complete all as specified and directed.
S & F Switch socket combination flush type multi purpose , 5A/16A, 5 in 1 controlled flush type 230 volts, single pole , complete all as specified and directed.
S & F lamp holder ( angular type) insulated body with back plate complete all as specified and directed.
S&F ceiling rose, surface type, 50mm dia 3 terminals, including PVC mounting block white/ivory finish.
S&F for stepped, electronic fan regulator flush type on the existing phenolic laminated sheet etc as required for ceiling fan 230 volt AC supply, 50HZ 1200/1400 mm sweep complete all as specified and directed.
S & F Bell push, flush type, 6 amp . 240 v, 50 Hz complete all as specified and as directed
S & F Bell dingdong type 240 V, 50 Hz complete all as specified and directed. Make : Anchor or Plaza with ISI marked as approved by GE.
M & L for sub main wiring complete with two single core 4.0 Sqmm (FRLS) PVC insulated, unsheathed multi stranded copper conductor cable, 1100 volts, grade FRLS drawn through PVC surface/concealed PVC conduit not less than 20mm size and with all accessories and fittings and , continuous PVC insulated copper earth wire 4.0 Sqmm complete fixed on the surface of wall/roof etc complete all as specified and as directed. (Note :- 2 runs of 4.0 Sqmm conductor, PVC conduit and one run of 4.0 Sqmm earth wire shall be measured as one unit length.)
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm bore ''medium grade' pipe for protection of G.I earth lead wire, both shall be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, including PCC (1: 2 : 4) type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm bore 'medium grade' pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion . (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. )
Taking down and S & F distribution board factory made SPN 4 way in, 240 Volt, Double door metal type suitable for fixing MCBs as out going and SPN MCB 32 Amps as main incoming complete all as specified & directed by Engineer in charge. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F MCB SPN 5 to 30 Amps 'B' series 10 KA with two position DIN Rail clamp complete all as specified and as directed. Make; Legrand / L&T / ABB.
S & F MCB SP 5 to 30 Amps 'B' series 10 KA with two position DIN Rail clamp complete all as specified and as directed. Make; Legrand / L&T / ABB.
Taking down old unserviceable conventional fitting and S & F Tube light fitting batten for LED 1X18W tube with LED tube rod retro bar professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size , complete all as specified & directed by Engineer in charge. Make : Bajaj cat part No : BLRB DB 118 & BLRB 18 W or equivalent of Wipro, philips or Crompton Greaves as approved by GE
Taking down ceiling fan / exhaust fans 1200/1400 mm sweep,including disconnection of electric connection and removing the blades in safe for reinstalling complete all as specified & directed by Engineer in charge.
Hanging only ceiling fan after cleaning, greasing,oiling, assembling the blades and painting etc including replacement of 3 core cable flexible as required at site from ceiling fan/ connection complete all as specified & directed by Engineer in charge. (Note:-Ceiling Fans as retrived from Serial item No. 114 above shall be used)
Supply and fix in repair LT indoor panel board made up of 2 mm thick MS Sheet duly powder coated with closing and locking arrangement as per suitable size fixing on wall with wooden plank of 18 mm thick inside panel including taking down and refixing existing electronic energy meter with replacemnt of following new items :- a) MCB DB TPN 4 way double door -01 No b) Isolator 4 pole 63A -01 No (Incoming) c) Isolator DP 40A - 05 No ( Out going)
Taking down old unserviceable conventional fitting and S & F Integral sleek extruded polycarbonate LED 1X10Wchannel with white acrylic cover with LED tube rod retro bar professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size, complete all as specified & directed by Engineer in charge. Make : Bajaj cat part No :BCLSB 10 NW or equivalent of philips, Wipro or Cromption Greaves as approved make by GE.
Supply and laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia 50 mm and inner dia 38 mm polythylene including coupler and bend with smooth internal and profiled external surface for non pressure under ground cable protection, complete all as specified Make :- Rex polyextrysion Ltd or equivalant as approved make by GE.
Supply, laying, connecting PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core complete all as specified and directed by Engineer-in-charge.
Supply, laying, connecting PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed by Engineer-in-charge.
S & F LED light fitting for building security/street light fitting Pressure die cast aluminium housing with IP66. 1x 45 w, 230 V,complete with all accessories internally pre-wired and including connecting up with 2.5sqmm twin core flexible copper cable for connection from ceiling rose to fitting including LED light and GI bracket of 1.2 meter shaped to 120 degree for fixing of fitting on wall with clamps complete all as specified and directed by Engineer-in-charge. Make : Bajaj cat part No : BRTFG 45W LED or equivalent of Wipro, philips or Cromption Greaves as approved by GE.
ANJALI CONSTRUCTIONS
MANIYA CONSTRUCTION CO.
M/S JAYCONSTRUCTION CO
Aishwarya Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .