| 1 | L1₹25.8 LAccepted-AOC | ₹25.8 L Quoted ₹26.4 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹27.3 L+₹82,811 (3.13%)Rejected-Finance | ₹27.3 L+₹82,811 (3.13%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹28.4 L+₹2.0 L (7.53%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹28.4 L+₹2.0 L (7.53%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹29.3 L+₹2.9 L (10.8%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹29.3 L+₹2.9 L (10.8%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹30.4 L+₹4.0 L (15.0%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹30.4 L+₹4.0 L (15.0%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
5 Jul 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
INTERNAL PERIODICALS SERVICES AND MISC B/R WKS INCLUDING REPAIR/ REPLACEMENT OF OLD WIRING WITH COPPER WIRING, DB, MCB, MCCB, LED FITTINGS AND FIXTURES AND MISC E/M WORKS OF ARMY HQ PROVOST UNIT, ASSU UNIT, IHQ OF MoD (ARMY), CIU MESS, DAPS-I, ARJAN
2023_MES_603708_1
GE/C-30/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
14 Aug 2023
16 Jun 2023
7 Jul 2023
16 Jun 2023
5 Jul 2023
30 Jun 2023
16 Jun 2023 - 30 Jun 2023
Amount
Preparation of old decorated surface (plastered or unplastered) of walls incl cornices pillar etc by brooming down or steel wire brushing scraping down smoke root mould moss and efforesceent salts and treating oil and greasy spots as applicable and applying one coat of white lime wash on walls surfaces all as specified and directed.
All as per item No 01 above but applying one coat of white lime wash on ceiling.
M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 cms width or girth using paint brush by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint brush all as specified and directed.
M&L for Preparation of old painted surfaces of steel of any description over 10 cms width or girth by using sand paper etc.for proper preparation and applying one coat of synthetic enamel paint all as specified and directed.
M&L removing existing old treatment from walls using mechanical grinder complete all as specified and directed.
M& L for prepration of old surface and applying a uniform thickness (average 2-3 mm thickness) of cement based wall care putty of entire surface of walls surfaces finished even and smooth complete all as specified and directed.
M& L for applying two coats of Oil Bound Distemper on wall surfaces over one coat primer to give an even and smooth surface all as specified and directed.
Taking down cement plaster from brick/concrete surfaces incl racking out joints hacking for key, scrubbing down with water etc.
M&L for ready mix plaster of 10mm thick on brick or conc surfaces in ceiling incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer instruction.
M&L for ready mix plaster of 15mm thick on brick or conc surfaces in wall incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer instruction.
M&L for preparation of new plastered surfaces and applying two coats of Oil Bound Distemper using roller brush to give an even and smooth surface having no sign of brush marksall as specifiedand directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of white lime wash complete all as specified .
S&F drappery curtain rods stainless steel 25 mm nominal dia of approved quality with two number decorative brackets design as approved fixed in brick/concrete wall with same finished knobs/latto on each end of curtain rod complete all as required and directed.
M& L for non skid coloured rectified ceramic tiles (400x400x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed for laying floor in CM 1:6 including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engineer in Charge, approved by GE.
M&L for coloured ceramic tiles (300x600mm)x7mm thick on vertical surfaces on skirting /dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engr-in-Charge, approved by GE.
M & L for 15mm bore GI tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc incl, cutting chases in wall where ever required and then making good including dismantling of old GI tubing complete all as specified and directed.
M & L for 20mm bore GI tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc incl, cutting chases in wall where ever required and then making good including dismantling of old GI tubing complete all as specified and directed.
M & L for 18-20 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4, as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished including dismantling the existing stone slab with screed/ backing and removal of debries out side the MOD Land complete all as specified and as directed by the Engineer-in-Charge. Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account.
S&F in repairs vitreous China coloured European type WC with "P" or "S" trap for 100 mm bore , including connection to drain and to flushing cistern with pipe 32mm dia PVC pipe and fixing bolts complete incl seat cover and PVC low level flushing cistern dual type10 ltrs capacity , C P Jet complete all as specified.
S&F in repairs vitreous chinaware coloured wash hand basin with pedestal of size 580mm x 450mm complete including , CP Waste couppling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge.
S&F in repairs stop valve 15mm dia fancy type chromium plated with long shank and cap (concealed type) complete all as specified.
S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc complete all as specified.
S&F in repairs chromium plated toilet paper holder, complete all as specified.
S&F in repairs chromium plated soap dish, complete all as specified.
S&F in repair plastic water closet seat cover/white closed pattern with flat bottom and cover and mild steel C hinges as per ISI complete all specified and directed.
S&F in repair stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe including connecting union overall size 1145mm x 510mm x 200mm with bowl size 510mm x 400mm x 200 mm including taking out existing Complete including fixing of granite slab with and including providing suitable size groove for adjusting top level ,moulding of slab each side and polished all as specified .
S & F in repairs 15 mm dia Brass CP three-in-one wall mixer for mixing hot & cold with L band water screwed down for iron pipe and fixed complete all as spd .
S & F in repairs 15 mm dia Brass CP mixer long Neck for sink mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified.
S & F in repairs 15 mm dia Brass CP WHB Mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified.
S & F PVC connection pipe of 15mm size with PTMT check nuts with washers of length 450mm, complete all as specified.
S&F in repairs angle valve 15mm dia fancy type chromium plated all as specified and directed by the Engr-n-charge.
S&F in repair 15mm dia CP bib tap fancy type chromium plated .
S&F in repairs PVC mirror cabinet of size 500X400X120mm fancy type fixed with 4 Nos stain less steel clips complete all as specified.
S&F in repairs fancy type PVC fibre body toilet cabinet size 600x450x6mm fixed with brass screw and cup and washer complete all as specified.
S & F in repair brass chromium plated towel ring including a pair of CP brass bracket coplete all as specified and directed.
S & F in repair Glass Corner Shelf 10mm thick including CP railing radius 300mm radius complete all as specified and directed by the Engineer-in-Charge.
S&F in repair Health faucet, CP brass with 1.50m long flexible pipe 15 mm bore of pipe screwed for iron pipe fancy pipe including two way angle cock as per requirement all as specified and as directed.
S&F in repairs Glass shelf assembly 450mm long 150mm wide with cp railing complete all as specified and as directed.
S&F in repairs CP brass shower rose 125mm size suitable for 15mm bore pipe with C P arms complete all as specified.
Dismantling Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge.
S&F Pre painted curved galvalum aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ,fixed with self tapering screws as specified by Engineer in Charge.
Dismantling mild steel framed trusses, rafter incl purlins complete all as specified and directed by Engineer-in-Charge.
S&F Roof trusses (framed), truss, framed brackets of angles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel flat or hollow sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed by Engineer-in-Charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down care fully copper/aluminium point wiring from wooden batten (except) conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing metallic/ non metallic conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
(a) One light/fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 46 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
(a) One light/Exh fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 48 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1 module / 2 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module / 4 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc. including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
M&L switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified.
M&L Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified.
M&L switch modular type 6 amp SP two way, 1 module complete all as specified.
M&L Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete.
M&L switch Modular type 16 Amps 1Way, 1 module with modular plat, 230V AC complete.
M&L Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete.
M&L modular stepped type electronic fan regulator 120W, 2 module complete .
M&L Switch piano flush button type single pole one way 6 Amps complete all as specified.
M&L switch piano flush button type single pole 16 Amps complete all as specified.
M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified.
M&L socket outlet 6 Amp flush button type complete all as specified.
M&L regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts.
M&L bell electric (dingdong) 230 volt, SP all complete all as specified and directed.
M/L insulated body, angle holder (metal ring) with back plate complete.
S&F ceiling rose surface PVC type with three terminals complete all as specified and directed .
M&L in repair sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified.
S & F in repair LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
S & F in repair LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
S & F in repair LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
S & F in repair surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S & F 30/35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S & F in repair LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
S & F in repair LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
S&F in replacement Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 4 sqmm cable shall be measured as one RM.
S & F in replacement Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three runs of 4 sqmm cable shall be measured as one RM.
S&F in replacement Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
S&F in replacement Sub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 10 sqmm cable shall be measured as one RM.
S & F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
S&F MCB DB SPN 02 way, single door 240 V AC 50Hz , with 10 Amps MCB SPN as incomer / out going complete.
S &F MCB DP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F in repair MCB DP 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting .
S & F in repair Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
S&F wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified .
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete.
S&F heating element of 1.5 KW any type with nut bolt washer complete all as directed.
S&F thermostat suitable for 25/35/50 ltr capacity of geyser complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Taking down carefully unserviceable distribution boards including disconnecting of incomming and outgoing connections complete all as specified and directed .
S & F in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified.
S&F in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
S & F LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge.
M&L for disconnecting all the cable connection from indoor LT Panel and servicing to Panel board (Approximate size 1700mm x1300mm x 300mm) opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable copper wiring kit and burn out unserviceable extended copper terminals/copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers and cleaning with air blower to serviceable parts like MCCB's, all terminals, replacement of damaged aluminium/copper lugs any discription of LT UG cable/ copper wire incomming and out going, welding of broken door with suitable hinges, replacement of defective copper wiring with suitable copper conductor with circuit indiator replacement of defective rubber beading,writing various feeder complete all as specified and as directed.
M&L for disconnecting all the cable connection from indoor LT Panel and servicing to Panel board (Approximate size 800 X 200 X 1200 mm) opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable copper wiring kit and burn out unserviceable extended copper terminals/copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers and cleaning with air blower to serviceable parts like MCCB's, all terminals, replacement of damaged aluminium/copper lugs any discription of LT UG cable/ copper wire incomming and out going, welding of broken door with suitable hinges, replacement of defective copper wiring with suitable copper conductor with circuit indiator replacement of defective rubber beading,writing various feeder complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4 mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified.
Supply and lay in replacement XLPE insulated PVC bedded galvanised steel strip or wire armoured electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including connection of cable at both ends with suitable size of glands, aluminum lugs complete jointing, testing and commissioning complete all as specified and directed.
Schedule of Credit
Pall Associates
M/S Sunil Steel Works
LAMBA ENTERPRISES
imran construction company
POONAM ENTERPRISES
a.k constructions
m/s VK construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .