Tender Value
₹9.3 Cr
EMD Value
₹6.1 L
Closing Date
31 Dec 2025, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT.GEN.
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(available in GCC), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Calculation of required minimum average annual contractual turnover:- V=Rs. 92870367, N=9 months = 0.75 years, V/N=Rs. 92870367/0.75 =RS. 123827156, V is less than V/N, Hence, required minimum average annual contractual turnover = Rs. 92870367
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: (1) Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Defination of Similar Work :- Electrification / Rewiring of Service or Residential building / Yard / HT / LT substation work / HT / LT cable work / street lighting / platform or building lighting management / circulating area Lighting / Electrical overhead power supply work / Electrical pump work etc.
13 conditions · 7 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Sch. A - KW - Proposed Yard remodeling for provision of additional passenger platforms for handing Kumbh Mela traffic in 2027 at Kherwadi Station.; Sch. B - KBSN - Proposed Yard remodeling for provision of additional passenger platform for handing Kumbh Mela traffic in 2027 at Kasbe Sukene Station.; Sch. C - DVL - Proposed Yard remodeling for provision of additional platforms for dealing passenger trains during Kumbh Mela 2027 at Devlali Station.; Sch. D - NK - Proposed Yard remodeling for provision of emergency cross over at Mumbai end to facilitate reception of DN train Up PF-4 at Nashik Station.; Sch. E - ODHA - Proposed Yard remodeling for provision of additional passenger platform and stabling lines for handling Kumbh Mela traffic in 2027 at Odha Station.; Sch. F - ODHA - Yard remodeling for provision of long haul failities for handling Long Haul trains at Odha Station.
BSL-L-W-T-63-2025~CR
BSL-L-W-T-63-2025
Open
Works - General
9 Months
Jalgaon, Maharashtra
₹0
₹6.1 L
31 Dec 2025
9 Dec 2025
17 Dec 2025
855 items across 6 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,08,82,874 | ||
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of USB Power charger HUB/Device enclosed inside the frame on the top, 5.2V DC / 8 Amp, 8 Ports (vertical) with reversible compability. Input Voltage: 110-290V AC, 1.5 Mtrs. Cable length, Blue coloured LED display for Current & Voltage at each port & smart chip for calibrating the Current required on each power port. Metal Holder attached with USB device to keep 8 Mobile Phone. Size 580 mm X 400 mm X 2 mm thick. | — | — | — | 47,010 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of Lighting Circuit Board, Double Door Powder coated with locking arrangement consisting 32 A DP RCBO as I/C and 6 Nos x 6 A SPMCB and 2 Nos x 20A O/G SPMCB Complete. | — | — | — | 41,960 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of Mains with 2x1.5 Sq.MM FR Copper PVC insulated wire laid in provided conduit/ Trunking/ inside pole/Bus-bars or any other places. | — | — | — | 29,500 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of PVC Flexible pipe 1/2 Inch | — | — | — | 17,051 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing and commissioning of teakwood /PVC Main Board with electronic KWH meter 5-30 A cap.230 V,50 hz. Single phase duly wired with FRLS multistranded PVC copper wire with MCB,cutout, neon indication & earth connection etc. | — | — | — | 8,445 | |
| for details. | Item Breakup | — | — | ||
| Provision of outdoor type Pre-cooling point with 1x4 pole 100 A MCCB 415 V, 63 A metal Clad Male & Female inter-locked industrial type 5 pin type plug and socket in 14 SWG CRCA sheet hot dipped galvanised enclosure mounted on angle stand complete. | — | — | — | 1,26,240 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification | — | — | — | 48,960 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification | — | — | — | 65,440 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification | — | — | — | 90,460 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm., with necessary material as per specification | — | — | — | 94,720 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 300 sq mm., with necessary material as per specification | — | — | — | 1,80,680 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification | — | — | — | 38,400 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification | — | — | — | 54,160 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification | — | — | — | 60,960 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 150 to 185 sq mm., with necessary material as per specification | — | — | — | 72,560 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification | — | — | — | 82,340 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core 16 sqmm armoured XLPE Cable. | — | — | — | 1,71,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core 25 sqmm armoured XLPE Cable. | — | — | — | 4,00,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of LT XLPE Armoured 4 Core 50 Sq mm Aluminium cable as per relevant IS. | — | — | — | 2,03,500 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 Core 70 sqmm armoured LT XLPE Cable. | — | — | — | 2,15,000 | |
| for details. | Item Breakup | — | — | ||
| Supply,laying,running fixing of 4 core 95 sqmm AL.Conductor, XLPE insulated, PVC sheathed, armoured cables as per relevant IS. | — | — | — | 2,39,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core 120 sqmm armoured LT XLPE cable ISI mark. | — | — | — | 2,98,500 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core 185 sqmm armoured XLPE Cable. | — | — | — | 92,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core armourd LT XLPE cable 240 Sqmm | — | — | — | 1,38,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of 4 core 300 sqmm armoured LT XLPE cable ISI mark. | — | — | — | 1,40,600 | |
| for details. | Item Breakup | — | — | ||
| Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) | — | — | — | 5,27,500 | |
| for details. | Item Breakup | — | — | ||
| Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. | — | — | — | 5,52,000 | |
| for details. | Item Breakup | — | — | ||
| Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. | — | — | — | 1,20,000 | |
| for details. | Item Breakup | — | — | ||
| Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware | — | — | — | 93,600 | |
| for details. | Item Breakup | — | — | ||
| Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. | — | — | — | 26,260 | |
| for details. | Item Breakup | — | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. | — | — | — | 1,12,500 | |
| for details. | Item Breakup | — | — | ||
| Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. | — | — | — | 2,65,295 | |
| for details. | Item Breakup | — | — | ||
| Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. | — | — | — | 15,100 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | — | — | — | 39,920 | |
| for details. | Item Breakup | — | — | ||
| Supply & Erection of RCC Warning Cover and refilling the cable trench in an approved manner. | — | — | — | 37,840 | |
| for details. | Item Breakup | — | — | ||
| Supply and laying of RCC cable Trench & Cover with metal lid for cable laying | — | — | — | 10,18,500 | |
| for details. | Item Breakup | — | — | ||
| Suppy of Polyolefin cable channel of size width 240/340 mm,height 155/230 internal/external length 1 meter produced of polylefin with fire protection class K-1 in accordance with DIN 53438 Sch. IIchannel attachable to each other with male female swallowtail connectors and having suitable detachable cover. | — | — | — | 10,75,800 | |
| for details. | Item Breakup | — | — | ||
| Supply, Fixing, testing and commissioning of Bus duct trunking system of 40 A (4+2) conducters, 3PH, 4 Wire, IP 55 with Center feed unit, 16 A tap off box (Every one meter), plug outlet covers, 16 A, 1 PH selectionplugs suitable for glass fuse, Ceiling bracket holder, suspension accessories shall be either galvanizedor power coated | — | — | — | 33,03,912 | |
| for details. | Item Breakup | — | — | ||
| Supplying & erecting mains with 4x10 sq.mm.and earth wire 6 sq.mm FR PVC copper wire, in rigid PVC conduit 32mm dia as per specification | — | — | — | 13,14,000 | |
| for details. | Item Breakup | — | — | ||
| Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. | — | — | — | 73,219 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of maintenance free earth as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008(REV '0') with improved earthing enhancing compound and exothermic welding | — | — | — | 7,50,650 | |
| for details. | Item Breakup | — | — | ||
| Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. | — | — | — | 1,03,000 | |
| for details. | Item Breakup | — | — | ||
| Providing & erecting Hot dipped Galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) Gl sheet of 300 mm width & 100 mm height comprising all required standard accesssories. | — | — | — | 5,33,000 | |
| for details. | Item Breakup | — | — | ||
| Supply,installation, testing & commissioning of 5 Mtr long hot dip galvanised octagonal pole with 130 mm bottom & 70 mm top made up of 3mm thick steel sheet along with base plate of size 200x200x12mm with foundation..(Along with 2 pole RCBO 6A, with 30 mA sensitivity). | — | — | — | 1,99,830 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of FRP Junction Boxes Size 12"x8"x4' with rewirable fuse and fixing accessories complete. | — | — | — | 3,25,500 | |
| for details. | Item Breakup | — | — | ||
| — | — | — | 30,640 | ||
| of all material,excavation ratio 1:3:6 for above work. | tio n :- Supply in | — | — | ||
| — | — | — | cement | ||
| — | — | — | concrete | ||
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing, commissioning of outdoor type feeder pillar board comprising of 400A FPMCCB complete with HRC Fuse base and Cartridge consists of aluminium bus bar 500V complete erected in 14 gauge CRCA sheet box with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation | — | — | — | 52,026 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of 20 Mtr. High Mast lighting tower with foundation alongwith 9x150 watt LED fittings complete with all accessories. | — | — | — | 5,11,128 | |
| for details. | Item Breakup | — | — | ||
| LED Flood light fittings of 250 watt with IP 66 protection and 5 years warranty as per attachedspecification. Required 250W LED Luminaire for flood light, IS 10322, IS:16107 (Q3) & 250 WATT IP66 Flood Light with 5 Years warranty | — | — | — | 1,92,760 | |
| for details. | Item Breakup | — | — | ||
| Supply, replacement, fixing, testing, connecting and commissioningof Inverter LED batten with square profile and poly carbonate/Extruded Aluminimum channel. Lithium Ion battery with chargingtime 8 hours-10 hours and back up time upto 3 to 4 hours energyefficient luminaries complete with all accessories of capacity 20 watt,4 feet length, LED lamps with suitable current control driver circuit,suitable for surface/recessed mounting as per IS:10322. LEDLuminaries:-(1) A complete LED lighting unit consisting of a lightsource and driver together with parts of distribute light,to positionand protect the light source,and to connect the light source to abranch circuit. The light source itself may be an LED array and LEDmodule, or an LED lamp. (2):-Supplied LED luminaries shall confirmto IS:16101(2012) IS :16106(2012).Light Source(LED) in theLuminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs toIS:16105(2012).IS:16108(2012),IEC:62471.1.Input operatingvoltage :-105-295 V AC.2:-Normal Voltage- 220V AC.3.Driver type:constant current driver with short circuit protection(For tubelight).4.Control of distribution:-Full cut off.5.Drive component:Industrial grade only .6.Efficiency of driver electronic:>= 85% (Fortube light).7.Colour temperature:5000-6500K(For tubelight).8.Colour rendering index(CRI):>75(For tube light).9.Ingressprotection :IP-20.10.Lumen output: >=100lumens/[email protected] drive current(For tube light).11.Powerfactor:->0.90(For tube light). 12.Total harmonics distrotion(THD):-<20%(For tube light).13.Lamp cover :Acrylic cover which does notresult in loss of lumens.14.Finishing:Power coated/Anodized.15.Secondry optics:poly corbonate reflector/ polycarbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitablefor surface mounting/recessed mounting.18.Certificate:Firm tosubmit LM80(In respect of LED used)& LM79(Inrespect of luminareused) test certificate from National/International accreditedLaboratory and OEM certificate for complience ofBIS/IEC.19.Warranty:Firm to submit warranty certificate for five yearalong with the supply.All fittings should be embossed/sticker withmanufacturing date and warranty details at time of supply.20.Theweight of fixture should be standard for better heat resistance of LEDPCB. All fittings shall be fitted as surface mounting/recessedmounting with twisted twin flexible cord of minimum size 16/0.2 mmcopper conductor as per relevant technical specification. Materialprameters must remain unchanged during entire warrantyperiod.20watt. | — | — | — | 37,950 | |
| for details. | Item Breakup | — | — | ||
| Supply, replacement, fixing, testing, connecting and commissioning of inverter bulk head fitting 10 watt with inbuilt battery backup. Lithium Ion battery with charging time 8 hours - 10 hours andback up time upto 3 to 4 hours energy efficient luminaries completewith all accessories of capacity 20 watt, 4 feet length, LED lampswith suitable current control driver circuit ,suitable forsurface/recessed mounting as per IS:10322. LED Luminaries:-(1) Acomplete LED lighting unit consisting of a light source and drivertogether with parts of distribute light,to position and protect the lightsource,and to connect the light source to a branch circuit. The lightsource itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS:16106(2012).Light Source(LED) in the Luminaries should be ofmake:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS/LEDNIUM. (2):-LEDs toIS:16105(2012).IS:16108(2012),IEC:62471.1.Input operatingvoltage :-105-295 V AC.2:-Normal Voltage- 220V AC.3.Driver type:constant current driver with short circuit protection(For tubelight).4.Control of distribution:-Full cut off.5.Drive component:Industrial grade only .6.Efficiency of driver electronic:>= 85% (Fortube light).7.Colour temperature:5000-6500K(For tubelight).8.Colour rendering index(CRI):>75(For tube light).9.Ingressprotection :IP-20.10.Lumen output: >=100lumens/[email protected] drive current(For tube light).11.Powerfactor:->0.90(For tube light). 12.Total harmonics distrotion(THD):-<20%(For tube light).13.Lamp cover :Acrylic cover which does notresult in loss of lumens.14.Finishing: Power coated/Anodized.15.Secondry optics:poly corbonate reflector/ polycarbonate lens.16.Construction of housing : extruded aluminum /CRCA/Pressure die cast aluminum. 17.Mounting : Suitable for surface mounting / recessed mounting.18.Certificate : Firm tosubmit LM80(In respect of LED used)& LM79(Inrespect of luminareused) test certificate from National/International accreditedLaboratory and OEM certificate for complience ofBIS/IEC.19.Warranty:Firm to submit warranty certificate for five yearalong with the supply.All fittings should be embossed/sticker with manufacturing date and warranty details at time of supply.20.Theweight of fixture should be standard for better heat resistance of LED PCB. All fittings shall be fitted as surface mounting/recessedmounting with twisted twin flexible cord of minimum size 16/0.2 mmcopper conductor as per relevant technical specification. Materialprameters must remain unchanged during entire warrantyperiod. | — | — | — | 71,200 | |
| for details. | Item Breakup | — | — | ||
| Supply, replacement, fixing, testing, connecting and commissioningof 45 Watt or above LED inverter street lights fittings with PDChousing, IP 66 and inbuilt battery backup with auto ON/OFF anddimming option(Dimming 50% on battery backup) and backup ofupto 3 to 4 hrs. LED Luminaries:-(1) A complete LED lighting unitconsisting of a light source and driver together with parts ofdistribute lights,to position and protect the light source,and toconnect the light source to a branch circuit.The light source itselfmay be an LED array and LED module, or an LED lamp.(2):- SuppliedLED luminaries shall confirm toIS: IS:16101(2012) IS:16106(2012).Light Source(LED) in the Luminaries should be ofmake:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS/LEDNIUM. (2):- LEDs toIS:16105(2012)IS:10322.IS:16108(2012),IS:10322,IEC:62471.TypeLED:- High power LED,SMD(Surface Mounting device).1.Inputoperating voltage :-105-295 V AC.2:- Normal Voltage- 220VAC,3.Driver type: constant current driver with short circuitprotection. 4.LED life:- >50000 burning hours .5.Depreciation:- 30%max.after 50000 burning hours.6.Control of distribution:-Full cut off.7.Surge protection:4KV (internal)+10KV(External Surge protectiondevice) .8.Drive component :Industrial grade only.9.Efficiency ofdriver electronic: > 85%.10.Beam angle:>=140 degree along withroad and &>=80 degree across the road.11.Colourtemperature:5000-6500K.12.Colour renderingindex(CRI):>=75.13.Ingress protection :IP-66.14.Lumen output:>120 lumens/watt.15.Power factor:>;0.95. 16.Total hormonicsdistrotion(THD):-<15%.17.Lamp cover :Toughened glass or UVstabilsed poly carbonate.18.Finishing:Power coated/Anodized.19.Secondry optics:poly corbonate reflector/ polycarbonates lens.20.Construction of housing: extrudedaluminum/CRCA/Pressure die cast aluminum.21.Mounting:Suitablefor existing pole/Truss/Lantern mounted.22.Certificate:Firm tosubmit LM80(In respect of LED used)& LM79(In respect of luminareused) test certificate from National/International accreditedLaboratory and OEM certificate for compliance ofBIS/IEC.23.Warranty:Firm to submit warranty certificate for five yearalong with the supply.All fittings should be embossed/sticker withmanufacturing date and warranty details at time of supply.20.Theweight of fixture should be standard for better heat resistance of LEDPCB.All fittings shall be fitted with new suitable bend/elbow withclamp and proper nut and bolt and connection with twisted twinflexible cord of minimum size 16/1 mm copper conductor as perrelevant technical specification. Materials prameters must remainunchanged during entire warranty period. | — | — | — | 3,48,800 | |
| for details. | Item Breakup | — | — | ||
| Supply, replacement, fixing, testing, connecting and commissioning of 60 Watt or above LED inverter street lights fittings with PDC housing, IP 66 and inbuilt battery backup with auto ON/OFF and dimming option (Dimming 50% on battery backup) and backup of upto 3 to 4 hrs. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute lights, to position and protect the light source, and to connect the light source to a branch circuit.The light source itselfmay be an LED array and LED module, or an LED lamp.(2):- SuppliedLED luminaries shall confirm toIS: IS:16101(2012) IS:16106(2012).Light Source(LED) in the Luminaries should be ofmake:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS/ LEDNIUM.(2):- LEDs to IS:16105(2012)IS:10322.IS:16108(2012),IS:10322,IEC:62471.TypeLED:- High power LED,SMD(Surface Mounting device).1.Inputoperating voltage :-105-295 V AC.2:- Normal Voltage - 220VAC, 3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours .5.Depreciation:- 30%max.after 50000 burning hours.6.Control of distribution:-Full cut off.7.Surge protection: 4KV (internal)+10KV (External Surge protection device) .8.Drive component :Industrial grade only.9.Efficiency ofdriver electronic: > 85%.10.Beam angle:>=140 degree along withroad and &>=80 degree across the load. 11. Colourtemperature:5000-6500K.12.Colour renderingindex(CRI):>=75.13.Ingress protection :IP-66.14.Lumen output:>120 lumens/watt.15.Power factor:>;0.95. 16.Total hormonicsdistrotion(THD):-<15%.17.Lamp cover :Toughened glass or UVstabilsed poly carbonate.18.Finishing:Power coated/Anodized.19.Secondry optics:poly corbonate reflector/ polycarbonates lens.20.Construction of housing : extrudedaluminum/CRCA/Pressure die cast aluminum. 21 .Mounting : Suitable for existing pole/Truss/Lantern mounted. 22. Certificate: Firm to submit LM 80 (In respect of LED used) & LM79 (In respect of luminare used) test certificate from National / International accreditedLaboratory and OEM certificate for compliance ofBIS/IEC.23.Warranty:Firm to submit warranty certificate for five yearalong with the supply.All fittings should be embossed/sticker withmanufacturing date and warranty details at time of supply.20.Theweight of fixture should be standard for better heat resistance of LEDPCB.All fittings shall be fitted with new suitable bend/elbow withclamp and proper nut and bolt and connection with twisted twinflexible cord of minimum size 16/1 mm copper conductor as perrelevant technical specification. Materials prameters must remainunchanged during entire warranty period. | — | — | — | 2,94,760 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of energy efficient 1x18 W indoor fitting LED batten with extruded aluminium housing with integrated LED Driver/Tube complete and associated accessories complete. | — | — | — | 10,400 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of LED street Light Roadway fittings in aluminium PDC housing, toughened glass cover with IP66 protection, Wattage 45 watts, input voltage-240 volts ac, 50Hz. Complete. | — | — | — | 96,580 | |
| for details. | Item Breakup | — | — | ||
| Supply, fixing, testing &commissioning of energy efficient BLDC motor industrial exhaust fan of size 300 mm (12") sweep and standard accessories, as per specifications in Annexure II. (Minimum Warrantee - 2 years) | — | — | — | 1,31,820 | |
| for details. | Item Breakup | — | — | ||
| Supply and commissioning of 3 KVA online UPS with 120 minutes battery back-up 72v system,MOSFET-PWM with inbuilt isolation transformer technology, input power- single phase 160-260V AC50Hz, output voltage- single phase 230V AC +- 1% sinewave 50Hz, Min. warranty of machine 2years. | — | — | — | 2,12,524 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing and commissioning of Astronomical street light control panel outdoortype CRCA sheet steel powder coated capacity- 6 kW single phase consisting digital 24 Hr timer, 32 A TP contactor, 40 A SPN (DP) MCB, auto/manual switch with complete wiring suitable to bemounted on channel/angle fixed on electrical pole IP-32 | — | — | — | 23,586 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of 2x20 Watts LED surface/suspended water proof industrial luminaries with polycarbonate housing and diffuser | — | — | — | 27,060 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of 2Ft 10 watt LED tube 4000 k all in one fixtures for Dressing, mirror and kitchen. | — | — | — | 14,140 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of LED Panel Light 39 to 42 Watt 6500K : 595x595x60 MM, 230 Volt, 50 HZ, AC similar to Philips product description RC370B LED 28S6500 L60W60 PSU OD make : Philips/Bajaj/CG. | — | — | — | 96,980 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of Bulkhead fitting with 10 W LED light with heat resistant glass cover and MS galvanised wire guard complete in toilet/bath. | — | — | — | 25,300 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of 15/18 Watt Warm White SLD Sqare / Round LED downlight fitting of size 6"x6" complete with all accessories. | — | — | — | 33,726 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing and commissioning of BLDC Super efficient electrical Ceiling Fan 1400 mm sweep (56') 260-280 RPM, Services value 7.7 input voltage 140-285 V. Power consumption 26 W to 30 W. Air delivery 270 CMM or more, 3 blades with double ball bearing with regulator of electronic step type and down rod 300-600 mm as per requirement, canopies, shackle. | — | — | — | 38,430 | |
| for details. | Item Breakup | — | — | ||
| SETC of Outdoor type LT panel as per IEC 61439 with double door, powder coated, locking arrangments, consisiting of 1 Nos x 250 A 4P MCCB as I/C and 4 Nos x 63 A 4P MCCB as O/G with ELR with CBCT for each MCCB, power quality analyser, communicable 3ph KWH meter, multifunction meter, 5 Nos x Indiacating lamp set (RYB), Copper bus bar, and other associate accessories complete. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) | — | — | — | 39,90,620 | |
| for details. | Item Breakup | — | — | ||
| Supply, erection, testing & commissioning of self contained drinking water cooler unit energy efficient compressor IS mark suitable for operation on 230 V +10 % 50 cycle single phase Ac supply storage capacity 150 Ltr cooling capacity 150 Ltr/Hr complete in place of old one as per specification. | — | — | — | 2,70,300 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 2 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 82,522 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 79,560 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 1,01,340 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 4 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indications per specification | — | — | — | 95,860 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 99,400 | |
| for details. | Item Breakup | — | — | ||
| Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short- circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 1,12,340 | |
| for details. | Item Breakup | — | — | ||
| Supply, fixing, testing, connecting and commissioning of 750 mm heavy duty wall mounted air circulator Fan suitable for 230 volts, 50 Hz - AC supply, >=1400 RPM, with wiring in flexible PVC pipe as required. Inspection by-Consignee. | — | — | — | 2,58,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of Insulation paint and painting of Octagonal poles / tubular poles/High Mast with 03 coats of insulation paint so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface | — | — | — | 94,000 | |
| for details. | Item Breakup | — | — | ||
| Supply of Insulation tape and application of the insulation tape on Octagonal poles / tubular poles/High Mast so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface. {1 Per Unit = 1 Roll of 5.0 CM (Width) x 33 M (Length)} | — | — | — | 5,210 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .