Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-Finance | ₹13.9 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹34.8 L+₹20.9 L (150.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹34.8 L+₹20.9 L (150.8%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹39.9 L+₹26.0 L (187.2%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹39.9 L+₹26.0 L (187.2%) | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L2 | cooltech engineering services L3 | M/s. Prakash Engineers Contractors and Suppliers L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down old refrigeration system comprising compressors, condenser, insulation, doors, air curtain, etc., including all connected items (indoor unit), and demolition of PUF panels in cold room and of foundation to facilitate replacement, complete all as specified and as directed.
Note: Items obtained from dismantling of cold room indoor and outdoor units shall be kept safely for reinstallation after installation of new PUF panels. | 1 | Each Job | 29,375 ₹29,375 | 32,000 ₹32,000 | 23,700 ₹23,700 Lowest |
| 2.00 | Installation, testing and commissioning of existing Blue Star cold room units comprising 03 Nos indoor units, 03 Nos outdoor units and 01 No air curtain, including all connected items of cold room approved by OEM. Work includes leak testing of all units, evacuation of gas and filling with nitrogen gas for 24 hours, rectification the leakages with and including required materials/ brazing etc. and refilling/ top up of refrigerant R-404A in existing Blue Star units of cold room, complete all as specified and as directed. | 1 | Each Job | 5,75,000 ₹5,75,000 | 5,79,000 ₹5,79,000 | 97,500 ₹97,500 Lowest |
| 3.00 | S&F in repair PUF panels for room of size 7.6 m × 7.6 m × 3.0 m (external dimensions), consisting of wall panels made of SS-304 (inner and outer skin) of 24 SWG sheets, minimum 127 mm thick, eco-friendly cyclopentane PUF panels SS inside and PPGI outside, suitable for maintaining temperature of (-18°C ± 2°C), including non-CFC refrigerant (R-404 A), communication frame, condenser stand, protective shed for condensing units, and foundation works with necessary angles, channels, silicone sealant, rivets, rods and PUF panels joinery and cam lock for modular construction (wall-to-wall and ceiling-to-ceiling), complete all as specified and as directed.
Note: Contractor shall prepare and submit detailed drawings of the complete cold room along with indoor units for approval by the GE before installation. | 132 | Sqm | 9,700 ₹12,80,400 | 12,000 ₹15,84,000 | 4,108 ₹5,42,256 Lowest |
| 4.00 | S&F in repair ceiling PUF panels made of SS-304 (inner skin and outer skin) of 24 SWG sheets, minimum 127 mm to 150 mm thick eco-friendly cyclopentane PUF panels SS inside and PPGI outside PUF panels joinery with cam-lock for modular construction (wall-to-wall and ceiling-to-ceiling), complete all as specified and as directed. | 51 | Sqm | 8,350 ₹4,25,850 | 12,000 ₹6,12,000 | 4,550 ₹2,32,050 Lowest |
| 5.00 | Providing floor insulation with 150 mm thick EPS slabs, using necessary bitumen, emulsion primer, plastic felt application, PCC and Kota stone flooring, with provision of man lock inside, manual internal override, internal electric hooter, external key lock, indoor-to-outdoor cabling including copper piping with insulation, communication frame, condenser stand, protective shed for condensing units, and foundation works, complete all as specified and as directed. | 1 | Each Job | 8,00,000 ₹8,00,000 | 8,05,000 ₹8,05,000 | 2,40,000 ₹2,40,000 Lowest |
| 6.00 | S&F in repair cold room door of minimum 127 mm thickness, inner SS-304 and outer PPGI sheet, size 34" × 78" SS 304 swing type, with 03 Nos heavy-duty hinges with insulation, complete all as specified and as directed. | 1 | Each | 1,00,000 ₹1,00,000 | 1,00,500 ₹1,00,500 | 67,000 ₹67,000 Lowest |
| 7.00 | S&F in repair drain heater suitable for (-18°C) cold storage, complete all as specified and as directed by the Engineer-in-Charge. | 14 | Running Metre | 2,500 ₹35,000 | 1,200 ₹16,800 Lowest | 2,200 ₹30,800 |
| 8.00 | S&F in repair cold room defrost heater operating on 230 V, complete all as specified and as directed by the Engineer-in-Charge. | 16 | Running Metre | 3,400 ₹54,400 | 3,900 ₹62,400 | 2,000 ₹32,000 Lowest |
| 9.00 | S&F in repair/replacement of VRF grade copper refrigerant pipe (suction and discharge lines), including brazing and connections to indoor and outdoor units of cold room, suitable for existing units as recommended by OEM, including insulation between indoor and outdoor units, complete all as specified and as directed. | 36 | Running Metre | 2,750 ₹99,000 | 3,000 ₹1,08,000 | 2,350 ₹84,600 Lowest |
| 10.00 | M&L in repair for point wiring complete with 1.5 Sqmm two single core PVC insulated, sheathed 1100 volts grade cable with stranded copper conductor FRLS grade conforming to IS-694 part II with ISI mark, FRLS grade drawn through and including suitable size rigid non metalic PVC conduit concealed with all accessories, including suitable size sunkpresses steel or cast iron terminal box with 3mm thick plastic laminated sheet top cover fixed flush with wall surface by means of brass screw and sunk cup washers for mounting of switches, sockets, fan regulators etc including providing 1.5 Sqmm PVC insulated sheathed stranded copper conductor cable as earth wire connected to metallic bodies of luminaires/ fan etc at one end and to common earth dolly at other end all as specified for fan/light point. | 3 | Per Point | 1,000 ₹3,000 | 2,000 ₹6,000 | 900 ₹2,700 Lowest |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
29 Aug 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
REPAIR/ REFURBISHMENT OF PUF SS INTEGRATED PANELS OF COOL AND COLD ROOM OF BVY OF NAVAL BASE AREA KARWAR
2026_MES_780330_1
8538/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer (Seabird) Karwar
₹29,800
Yes
22 Sept 2026
1 Aug 2026
31 Aug 2026
1 Aug 2026
29 Aug 2026
15 Aug 2026
1 Aug 2026 - 8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and taking down old refrigeration system comprising compressors, condenser, insulation, doors, air curtain, etc., including all connected items (indoor unit), and demolition of PUF panels in cold room and of foundation to facilitate replacement, complete all as specified and as directed.
Note: Items obtained from dismantling of cold room indoor and outdoor units shall be kept safely for reinstallation after installation of new PUF panels. | - | Each Job | 1.25 | - |
| 2 | Installation, testing and commissioning of existing Blue Star cold room units comprising 03 Nos indoor units, 03 Nos outdoor units and 01 No air curtain, including all connected items of cold room approved by OEM. Work includes leak testing of all units, evacuation of gas and filling with nitrogen gas for 24 hours, rectification the leakages with and including required materials/ brazing etc. and refilling/ top up of refrigerant R-404A in existing Blue Star units of cold room, complete all as specified and as directed. | - | Each Job | - | - |
| 3 | S&F in repair PUF panels for room of size 7.6 m × 7.6 m × 3.0 m (external dimensions), consisting of wall panels made of SS-304 (inner and outer skin) of 24 SWG sheets, minimum 127 mm thick, eco-friendly cyclopentane PUF panels SS inside and PPGI outside, suitable for maintaining temperature of (-18°C ± 2°C), including non-CFC refrigerant (R-404 A), communication frame, condenser stand, protective shed for condensing units, and foundation works with necessary angles, channels, silicone sealant, rivets, rods and PUF panels joinery and cam lock for modular construction (wall-to-wall and ceiling-to-ceiling), complete all as specified and as directed.
Note: Contractor shall prepare and submit detailed drawings of the complete cold room along with indoor units for approval by the GE before installation. | - | Sqm | 1 | - |
| 4 | S&F in repair ceiling PUF panels made of SS-304 (inner skin and outer skin) of 24 SWG sheets, minimum 127 mm to 150 mm thick eco-friendly cyclopentane PUF panels SS inside and PPGI outside PUF panels joinery with cam-lock for modular construction (wall-to-wall and ceiling-to-ceiling), complete all as specified and as directed. | - | Sqm | 2 | - |
| 5 | Providing floor insulation with 150 mm thick EPS slabs, using necessary bitumen, emulsion primer, plastic felt application, PCC and Kota stone flooring, with provision of man lock inside, manual internal override, internal electric hooter, external key lock, indoor-to-outdoor cabling including copper piping with insulation, communication frame, condenser stand, protective shed for condensing units, and foundation works, complete all as specified and as directed. | - | Each Job | 3 | - |
| 6 | S&F in repair cold room door of minimum 127 mm thickness, inner SS-304 and outer PPGI sheet, size 34" × 78" SS 304 swing type, with 03 Nos heavy-duty hinges with insulation, complete all as specified and as directed. | - | Each | 4 | - |
| 7 | S&F in repair drain heater suitable for (-18°C) cold storage, complete all as specified and as directed by the Engineer-in-Charge. | - | Running Metre | 5 | - |
| 8 | S&F in repair cold room defrost heater operating on 230 V, complete all as specified and as directed by the Engineer-in-Charge. | - | Running Metre | 6 | - |
| 9 | S&F in repair/replacement of VRF grade copper refrigerant pipe (suction and discharge lines), including brazing and connections to indoor and outdoor units of cold room, suitable for existing units as recommended by OEM, including insulation between indoor and outdoor units, complete all as specified and as directed. | - | Running Metre | 7 | - |
| 10 | M&L in repair for point wiring complete with 1.5 Sqmm two single core PVC insulated, sheathed 1100 volts grade cable with stranded copper conductor FRLS grade conforming to IS-694 part II with ISI mark, FRLS grade drawn through and including suitable size rigid non metalic PVC conduit concealed with all accessories, including suitable size sunkpresses steel or cast iron terminal box with 3mm thick plastic laminated sheet top cover fixed flush with wall surface by means of brass screw and sunk cup washers for mounting of switches, sockets, fan regulators etc including providing 1.5 Sqmm PVC insulated sheathed stranded copper conductor cable as earth wire connected to metallic bodies of luminaires/ fan etc at one end and to common earth dolly at other end all as specified for fan/light point. | - | Per Point | 8 | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender8538.pdf
Tender Documents • 0.92 MB
BOQ_874075.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .