Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-Finance | ₹4.2 L | L1 | Accepted-Finance Lowest Bid |
| 2 | L2₹4.5 LRejected-Finance | ₹4.5 L | L2 | Rejected-Finance Higher Bid |
| 3 | L3₹4.6 LRejected-Finance | ₹4.6 L | L3 | Rejected-Finance Higher Bid |
| Sl No | Description | Qty | Unit | TWILIGHT ELECTRICALS L2 | SOURAJIT CHAKRABORTY L1 | NEXTGEN L3 |
|---|---|---|---|---|---|---|
| 1.00Sub Head----01 SITC SAC unit | ||||||
| 1.01 | S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for
1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy) | 2 | ea | 77,000 ₹1.5 L | 75,000 ₹1.5 L | 78,000 ₹1.6 L |
| 2.00 | S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS
1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply.
(Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy) | 2 | No | 87,000 ₹1.7 L | 85,000 ₹1.7 L | 88,000 ₹1.8 L |
| 3.00Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC. | ||||||
| 3.01 | 1.5/2 Tr | 4 | Item | 1,500 ₹6,000 | 1,900 ₹7,600 | 2,000 ₹8,000 |
| 3.02Sub Head---02 Miscelleneous Items | ||||||
| 4.00 | supply and drawing 5/8' & 1/4" copper refrigerant pipes with 9 mm thick nitrile rubber insulation along with other accessories, wrapping tape etc. on the surface of wall as per direction of EIC | 40 | Mtr | 220 ₹8,800 | 180 ₹7,200 | 200 ₹8,000 |
| 5.00 | Supply and drawing copper communication & controlling cable of following size-4Core x 2.5 sq.mm copper cable (Make: Finolex / KEI / Polycab / Havells/ RR/Gloster) | 40 | Mtr | 220 ₹8,800 | 180 ₹7,200 | 200 ₹8,000 |
| 6.00 | Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC | 37 | Mtr | 220 ₹8,140 | 180 ₹6,660 | 200 ₹7,400 |
| 6.01Sub Head----03 Grill Guard protection | ||||||
Updated dates
Tender Value
₹4.2 L
EMD Value
₹8,358
Closing Date
6 Apr 2026, 12:00 pmClosed
Executive Engineer Cooch Behar Electrical Division
Executive Engineer Cooch Behar Electrical Division
Urgent replacement of old unitary Air Conditioning units installed at different places of MJN Hospital under MJN MC and H, Cooch Behar. Electrical Work
2026_WBPWD_1022045_1
WBPWD/EE/CED/eNIT-47/2025-2026
Open Tender
ELECTRICAL WORKS M/R
14 days
Cooch Behar
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,358
13 May 2026
13 Mar 2026
8 Apr 2026
13 Mar 2026
6 Apr 2026
19 Mar 2026
Sub Head----01 SITC SAC unit
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (5.2 KW - 5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/ R410A,, Air flow range CFM (560 - 600), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy)
S&D of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Mitsubishi Heavy)
Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
Sub Head---02 Miscelleneous Items
supply and drawing 5/8' & 1/4" copper refrigerant pipes with 9 mm thick nitrile rubber insulation along with other accessories, wrapping tape etc. on the surface of wall as per direction of EIC
Supply and drawing copper communication & controlling cable of following size-4Core x 2.5 sq.mm copper cable (Make: Finolex / KEI / Polycab / Havells/ RR/Gloster)
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC
Sub Head----03 Grill Guard protection
S & F iron cage ( 4O"x 36"x24" ) structure for the split AC machine ODUs on wall for holding and provide protection with locking arrangement & shade arrangement above the grills with corrugated tin shade, necessary anti-rust painting as per direction of EIC
sub head- 04 EI work associated AC unit
Supply & fixing of 240V, 50 Hz, 1ph OLP 3+ starter with digital display for split AC machine (1.5/ 2 TR) having rated current 21A, Voltage range 160-270 Volt having IP-20 protection and provision for display voltage, current & any fault indication (Make- Electron) incl. neccy. connection incl. supply material like wire, lugs etc. if required) and commissioning the same.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as to GS
Supply & Fixing of 250V, 25A timer controlled single starter for controlling one no. room Air Conditioning Machine in SS double door 2+10 way DB enclosure (L&T / ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC : -
i) 25A DP MCB (L&T / ABB / Legrand make) – 1 no. ii) 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) – 1 no. iii) 3-pole power contactor (L&T make Cat no MNX22 / 250V) – 2no. [1W+1S units]
iv) 3A SP MCB [for ON/OFF the Timer]-1no
v) LED indication lamp (L&T/Legrand/Scneider) – 2 no. vi) Outgoing bakelite connector 32A (Reputed make as approved by EIC) – 2 nos. vii) with lock & key arrangement
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (for PB & RAC)
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as to GS
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tendernotice_2.pdf
PDF • 1.03 MB
BOQ_2512010.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid