Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee | Not Admitted-Fee Fee not received |
| 4 | Not Admitted-Fee | Not Admitted-Fee Fee not received |
| 5 | Not Admitted-Fee | Not Admitted-Fee Insufficient Fee amount |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
15 Jan 2020, 4:00 pmClosed
Sr. Regional manager
RIICO Ltd. Bichhwal Bikaner
Commissioning of two no tubewell and construction of new CWR at Inductrial Area Bichhwal
2019_RIICO_173214_1
21f/2019-20
Open Tender
Civil Works
Percentage
183 days
Bikaner
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,360
RIICO Ltd
₹92,000
Yes
20 Jan 2020
19 Dec 2019
17 Jan 2020
20 Dec 2019
15 Jan 2020
20 Dec 2019
Amount
Dismantling of RCC CWR of capacity 4.50 lac litr consisting RCC foundation, wall, ventilators etc including removal of dismantled concrete and steel reinforcement etc and refilling the gound depression with soil complete as per direction of engineer-in-charge.
Construction of RCC CWR as per latest code-456 and other relevant codes including complete design & drawing from MNIT jaipur having capacity 450 KL with proper reinforcement in top and base slab vertical wall including provision of MV sheets at joints, MS ladders, retro reflective water level, indicator, ventilators, railing, plinth protection work including fixing of D/F CI pipes (class B) for inlet, outlet, washout and overflow including CI specials like puddle collars/bends/duck foot bends etc. complete as per attached detailed tender specification & schedules. The outer surface of CWR shall be painted by approved waterproofing cement paint including testing for stability of structure & water tightness . The work includes plinth protection of CWR as per drawing with necessary drains and its complete. The work include the minimum supply & fixing of CI double flangepipes. The work include the supply and fixing of CI specials like tees, bands, reducers, tail pieces and all required accessories as per IS specifications for Class 15 as per requirement. The work should be executed as per direction on Engineer-In-Charge.
Supply and fixing C.I double flange pipes and different sized for inlet outlet washnet and overflow including nut bolts, rubber rings etc. of required size as per I.S specification and direction of engineer-in-charge. Inlet/outlet/washout/overflow pipes of 100 mm dia.
SITC of ISI mark( IS:8472) self priming monoblock pump set of approved make, TEFC, permanent split capacitor type (PSC), fitted with thermal overload protection, mechanical seal, 1440/1500 RPM, single phase(180 to 240 V). Including cost of hardware etc in following size 20HP, 3-Ø, (6-28) mtr, (45-7.5) LPM (Group 1)
Providing and fixing of Non Return Valve ISI marked including nut, bolts, rubber sheet etc complete on rising main.
Bidder Name
Amount
SHREE RAM CONSTRUCTION COMPANY
Krishnodaya Const Co.,
Krishnodaya Const Co.,
Krishnodaya Const Co.,
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .