Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.1 CrAccepted-AOC | ₹57.1 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹61.0 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹61.0 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹61.8 CrRejected-Finance | ₹61.8 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹64.8 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹64.8 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹65.4 CrRejected-Finance 126 A JAIPUR HOUSE AGRA 282010 PH NO 0562 2810176 9897638555 | ₹65.4 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
27 Dec 2019, 6:00 pmClosed
CHIEF ENGINEER CG GOA
Headquarters Chief Engineer Indian Coast Guard Chicolna, JNC Nagar Road, Bogmalo Post Goa 403806
CONSTRUCTION OF DEFICIENT MD ACCN FOR OFFICERS EPS AND DSC PERSONNEL AT CHICOLNA GOA
2019_MES_300574_1
81034/E8
Open Tender
Civil Works
750 days
CHICOLNA GOA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹3,000
GE (I) (P) Ratnagiri
₹15 L
Yes
6 Mar 2020
25 Nov 2019
2 Jan 2020
25 Nov 2019
27 Dec 2019
13 Dec 2019
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Total of Schedule 'A' Part-I B/F from Serial Page No 31
SCHEDULE "A" PART-II ( EARTH WORK AND SITE CLEARENCE) Total of Schedule 'A' Part-I B/F from Serial Page No 33
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Total of Schedule 'A' Part-I B/F from Serial Page No 35
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Total of Schedule 'A' Part-I B/F from Serial Page No 39
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Total of Schedule 'A' Part-I B/F from Serial Page No 42
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Total of Schedule 'A' Part-I B/F from Serial Page No 44
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Schedule 'A' Part-I B/F from Serial Page No 46
SCHEDULE "A" PART-VIII (RETAINING WALL) Total of Schedule 'A' Part-I B/F from Serial Page No 48
SCHEDULE "A" PART-IX (COMPOUND WALL ) Total of Schedule 'A' Part-I B/F from Serial Page No 50
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Total of Schedule 'A' Part-I B/F from Serial Page No 52
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIFICATION) Total of Schedule 'A' Part-I B/F from Serial Page No 56
SCHEDULE "A" PART-XII (FIRE FIGHTING) Total of Schedule 'A' Part-I B/F from Serial Page No 64
SCHEDULE "A" PART-XIII (CONDUIT FOR TELEPHONE/ TV) Total of Schedule 'A' Part-I B/F from Serial Page No 65
SCHEDULE "A" PART-XIV (LIGHTNING PROTECTION) Total of Schedule 'A' Part-I B/F from Serial Page No 66
SCHEDULE "A" PART -XV (MISCELLANIOUS ITEMS)
INTERNAL WATER SUPPLY S& F overhead shower 120 mm dia round shape single flow (ABS body crome plated with gray face plate) with rubit cleaning system Make - Jaquar Model No OHS -1789 or equivalent in Crab Tree/Kohler brand.
Supply, install and test electric water heater (Geyser) vertical storage type of capacity 25 lts to work on single phase,l 230 volts, 50 Hz supply including provision of bolts, nuts, washers and grouting on walls and making good the disturbed portion to match with the existing surfaces and provision of suitable PVC pipe connection for hot, cold water connections with chromium plated brass check nuts incoming and out going and one number non return valve complete all as specified and directed.
S&F Health faucet (ABS body) with 01 meter long PVC tube & wall hook. Make - Jaquar Model No ALD-CHR- 583 or equivalent in Crab Tree/Kohler brand.
S&F fancy type chromium plated hot and cold basin mixer ISI marked including all fixing arrangements into theGI pipe of 15 mm bore complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY S & F 20 W surface/wall mounted LED batten, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life LED chips, CRI ≥ 80, power factor ≥ 0.95, system luminous efficacy > 100, having average life 50000 hrs, operating voltage 140- 270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. [Make: BAJAJ 112785 BCLAB 20W or equivalent]
S & F 10 W surface/wall mounted LED batten tubelight, including LED tube/module, with PC diffuser and extruded aluminium anodised housing with LEDs as light source having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.98, CCT 6500K, THD < 10%, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. [Make: BAJAJ 112407 BCLSB 10 WH or equivalent]
S & F 20 W LED security light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection, including necessary electrical connections to security light fittings with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. [Make:BAJAJ BCLST 20W LED I or equivalent]
S & F BEE five star rated high-speed ceiling fan, conforming to IS 374- 1979, having 1200 mm blade sweep, speed not less than 370 RPM, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. [Make: CROMPTON EMPOWER 50 or equivalent]
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, speed not greater than 1760 RPM, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. [Make: CROMPTON VENTILUS or equivalent]
S & F engery efficient metalic exhaust fan, having blade sweep 300 mm, speed not greater than 1400 RPM, air delivery not less than 1850 CMH, operating voltage 220-240 V and frequency 50 Hz, ncluding electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the exhaust fan complete all as specified and directed. [Make: CROMPTON EXHD300-4-1 or equivalent]
S & F ISI marked MCB having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002 complete all as specified and directed. [Make: Legrand or equivalent]
6 A, 230 V, 50 Hz SP MCB C- curve
16 A, 230 V, 50 Hz SP MCB C- curve
M & L for 2.0 mm thick hot-dip galvanized & powder coated perforated cable tray, conforming to IEC 6537, including accessories, supports and other sundry items of following sizes
200 mm (W) X 50 mm (H)
S&F single phase energy meter, direct operation with CT, ISI marked as per IS 13779/1999/CBIP-88 of rated current capacity 5-30 Amps with rated voltage 240 watts, accuracy class 1.0 with power consumption less than 8 Va, with overload capacity of six times of basic current, immune to various distrubances to Digital LCD display of (instanteneous active energy KWH, power and different tamper indicator, date and time display) with last six month MD storage alongwith communication port complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply, install, test and commissioning Pump set, centrifugal pumpset 10 HP, electric driven, 3Ph, 415 V, 50 Hz of capacity 645 LPM at 50 Mtr head complete with necessary suction side GI pipe medium grade, , pressure gauge & PCC foundation and connecting up with delivery main complete all as per manufacturer's specification and all as specified.
Supply, install, test and commissioning Pump set, centrifugal pumpset 25 HP, electric driven, 3Ph, 415 V, 50 Hz of capacity 1433 LPM at 50 Mtr head complete with necessary suction side GI pipe medium grade, GM Foot valve, pressure gauge & PCC foundation and connecting up with delivery main complete all as per manufacturer's specification and all as specified.
Cutting theexisting DI/CI pipe of 150 mm dia and reducing to required length inposition for inserting new teel, branches etc.
Supply, laying and jointing in trenchews DI pipes 200 mm bore, class - K 7 of standard length spigotand socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating and external surface with bituminous paint as per IS specification & directed.
Supply, laying and jointing in trenchews DI pipes 150 mm bore, class - K 7 of standard length spigotand socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating and external surface with bituminous paint as per IS specification & directed.
Supply, installing.Testing ands commissioning of NRV, butterfly valve type with necessary fittings, flanges, nut bolts etc as per specification Details Non return valves shall be cast iron spring action swing check type. An arrow mark in the direction of flow shall be marked on the body of the valve. The valve shall bear to IS 5312 certificaton. The valve shall be of cat iron body and cover. The interna flap in the direction of the water shall be of cast iron and hinged by a hinge pin of high tensile brass or stainless steel cast iron parts shall be confirm to 13 : 210/7, grade 200/260 type of size 80mm dia. (make: AUDOC/ Kirloskar/Intervalve)
Supply and fix foot valve 65 mm (2.5") dia, confirming to IS: 4083, dead weight plunger with guide weight, rubber flap complete with joining materials i.e rubber gasket, nuts, bolts and washers etc complete all as specified and directed.
Supply and fix foot valve 100 mm (4") dia, confirming to IS: 4083, dead weight plunger with guide weight, rubber flap complete with joining materials i.e rubber gasket, nuts, bolts and washers etc complete all as specified and directed.
Supply and fix strainer Y type at the inlet of pump to avoid any impurities entering the pump, confirming to IS, size 80 mm (3") dia.
Supply and fix strainer Y type at the inlet of pump to avoid any impurities entering the pump, confirming to IS, size 100 mm (4") dia.
Supply and fxing of GM gate valve/ stop valve , high pressure, full way with brass spindle and iron hand wheel at the top, ISI mark, screwed at both ends suitable for 80 mm dia steel pipe complete with all jointing materials etc all as specified ane directed.
M & L for construction of valve pit of size 120X120X120 cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregated) sub base of floor, 50mmm PCC 1:2:4 type B - 1 using 20mm graded crushed stone aggregate) in floor fininshed even and fair without using extra cement, one brick thick brick work in CM 1:4, 15mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit cover fixing with angle iron frame 40X40X6 mm thick complete with locking arrangements having provision of lifting handle including 2 coats of synthetivc enamel paint over one coat of red oxide primer to steel surface and excavation in soft/ lose soil, retuning filing and removal of surplus soil up to 50 mtr distance complete and all as specified shown on drawing ande as directed.
M & L for construction of valve pit of size 90cm X 90cm X 90cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregated) sub base of floor, 50mmm PCC 1:2:4 type B - 1 using 20mm graded crushed stone aggregate) in floor fininshed even and fair without using extra cement, one brick thick brick work in CM 1:4, 15mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit cover fixing with angle iron frame 40X40X6 mm thick complete with locking arrangements having provision of lifting handle including 2 coats of synthetivc enamel paint over one coat of red oxide primer to steel surface and excavation in soft/ lose soil, retuning filing and removal of surplus soil up to 50 mtr distance complete and all as specified shown on drawing and directed.
M & L for earthing complete with GI earth plate electrode 60cm x 60cm x 3 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth strip 32 X 6mm by means of bolts, nuts and washers of GI protecte by GI pipe light grade 40 mm dia as shown in electrical plate No.3 and connected to equipment including excavation, earth work, PCC pit, RCC cover 50mm thick, 20mm dia medium grade GI Pipe with funnel and wire mess for watering, testing on completion all as directed by Engineer- in- Chief.
EXTERNAL ELECTRIFICATION Supply and Install Indoor load break switch 11 KV, 630 A, 26.30 KA with fuse trip, earth switch, dynemic mimic arrangment, 230 V AC shunt trip coil incliding MS sheet enclosure suitable for indoor installation with MS Base channel all a directed and specified
Supply & Installed Transformer step up/step down, indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity 500 KVA including connecting testing and commissioning, foundation and cattle fencing around transformer complete, as directed by Engr-in-Charge.
Supply & Installed Transformer step up/step down, indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity 200 KVA including connecting testing and commissioning, foundation and cattle fencing around transformer complete, as directed by Engr-in-Charge.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (Main panel offrs Md Accn area):- INCOMING:- (a) MCCB with microprocessor based release, 4 pole, 350 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB, 4 pole, 300 Amps, 50 Hz, 415 Volts, 35 KA -03 Nos (b) MCCB, 4 pole, 125 Amps, 50 Hz, 415 Volts, 35 KA -01 Nos
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (For offrs Md Accn area):- INCOMING:- (a) MCCB with microprocessor based release, 4 pole, 300 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB 4 Pole, 160 Amps 415 Volts, 25 KA - 01 Nos (b) MCCB 4 Pole, 125 Amps 415 Volts, 25 KA - 02 Nos
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (Main panel sailors Md Accn area):- INCOMING:- (a) ACB , 4 pole, 415 V, with thermal magnetic release (Manual drawout type) of capacity 1000 Amps - 1 No (Incoming) OUTGOINGS:- (a) ACB , 4 pole, 415 V, with thermal magnetic release (Manual drawout type) of capacity 800 Amps - 03 Nos. (b) MCCB with microprocessor based release, 4 pole, 160 AMPS, 50 Hz, 415 Volt, 35 KA - 01 No.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 500 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (For sailors & DSC blocks Md Accn area):- INCOMING:- (a) MCCB with microprocessor based release, 4 pole, 500 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB 4 Pole, with microprocessor based release 350 Amps 415 V, 35 KA - 01 Nos (b) MCCB 4 Pole, 250 Amps 415 Volts, 25 KA - 01 Nos (c ) MCCB 4 Pole, 200 Amps 415 Volts, 25 KA - 02 Nos
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (For sailors 2 blocks Md Accn area):- INCOMING:- (a) MCCB with microprocessor based release, 4 pole, 350 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB 4 Pole, 250 Amps 415 Volts, 25 KA - 03 Nos
Supply and fix time switches 250V single phase of 20 Apm rating with contrctor fitted inside steel enclosure.
Supply and erect RCC pole, 9 m long, 130mmx100mm at top and 230x150mm at bottom , conforming to IS 785:1964 complete all as specified and directed.
Supply and fix street light fitting LED 45 Watts sleek pressure dia cast aluminum housing with heat resistant galss . IP 65 protection netter otics for uniform dstribution including 1.5m long GI bracket, bent to shape, clamp, nut bolts of suitable size complete all as specified and as directed. Make : cat no. LSTP-45-CDL of Crompton or Equivalent model in Philips/ Havells approved by GE.
S&F single piece moulded SMC box of size 230x185x110 mm outer & 195 x 135 x 90mm inner dimensions consisting of one SP MCB 6 Amps & one 4 way connector, including all necessary fixing arrangements of fixing to LT pole ie necessary Clamps, nut, bolts & Washers of suitable size. Make : Sintex/National/ any other equivalent make as approved by GE.
Supply and lay PVC insulated PVC sheathed electric control cable with stranded copper conductor of size 1.5 sqmm 2 core 1100 volts grade
Supply, installation and testing of low intensity twin avaiation light complete of LED type with 302 red LED operating voltage 80V-280V, AC or 20V-60V DC, Ip-65, Protection conforming to ICAO/FAA standards, inbuilt n /OFF phoo cell all as specified Make : bajaj cat Part no.110731 BGAV 302 LED or equivalent.in Philips /Crompton.
S & F Electrical insulating mats confirming to IS 15652/2006 class C dielectric strenth 65 KV AC RMS Voltage grade up to 3.3 - 11 KVA of size 1 M x 2M x2.0 MM
S & F Electrical insulating mats confirming to IS 15652/2006 class B dielectric strenth 45 KV AC RMS Voltage grade up to 3.3 - 11 KVA of size 1 M x 2M x2.5 MM
Electric rubber hand gloves 11 KV
FIRE FIGHTING Supply & laying and jointing in trenches DI pipes 150mm bore, class K-9 of stranded length spigot and socketed and push type joint with rubber gasket as jointing material, internal cement mortar coating and external surface with bituminous paint as per IS specification & directed.
Supply laying and fixed to wall/floor/ceiling PVC insulated screened PVC sheathed galvanised steel strip or wire armoured with stranded copper conductor of size 1.5 Sqmm 2 core and 1.5 Sqmm earth wire 1100 Volts grade complete all as specified and directed.
Supply and install LT Panel board, 3 phase, 4 wire, 415 Volts, 50 HZ, 100 Amps capacity out door cubical type made out of CRCA sheet 3.15 mm thick with aluminium bus bar and measuring instruments complete and consisting the following. INCOMING:- MCCB 4 POLE, 16 KA, 63 Amps 415 VOLTS - 1 No OUTGOINGS:- (a) MCB TPN 32 Amps - 2 No (b) DOL Starter for 7.5HP Pump set-1 No
Supply and fix Valve, globe/gate with iron wheel screwed both ends for iron pipe and fixed complete of size 80mm confirming to IS 9338, all as specified and directed.
M&L for earthing complete with GI pipe plate eletrode 60cm x 60 cm x 6.3mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth wire 4.0 mm dia by means of bolts, nuts and washers of GI protected by GI pipe light grade 15mm dia all as shown in electrical plate No 3 and connected to equipments including excavation , earth work, PCC pit, RCC cover 50mm thick, 20mm dia medium grade GI pipe with funnel and wire mess for watering, testing on completion all as directed by Engineer-in - charge.
M&L for construction of valve pit of size 120x120x90 cm internal dimensions with 100mm thick PCC 1:4:8 type D2 (using 40 mmm graded broken stone aggregate) sub base of floor, 50mm PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in floor finished even and fair without using xtra cement, one brick thick brick work in CM 1:4, 15 mm thick plaster in CM 1:4 inluding 3mm thiock MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with locking arrangements haviong provision of lifting handle including 2 coats of synthetic enamel paint cover one code of red oxide primer to steel surface and excavation in soft/ loose soil , returning filling and removal of surplus soil upto 50mtr distance complete all as specified shown on drawing and as directed.
DG SET Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 82.5 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following:- (Gen set model No. KEC-C82.5-II) Make :- Kirlosker/Cummins/
A. Diesel Engine: Water cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:-(Make: Kirloskar Model No. 3B5D-1C85RW Ltd/Cummins India Ltd). Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators.
(j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) battery voltage (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed. (v) Engine hours.
(vI) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-1No. 12 volts DC, 180AH, maintenance free battery with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. B. Alternator: Suitable rated at 82.5 KVA factor , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H IP -23, self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before Make- Kirloskar Model No. 4AB225S1 STAMFORD/Crompton Greaves.
C. Acoustic Enclosure:- M & L for acoustic enclosure for the above 82.5 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton. D. AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(i) AMF control circuit with 4 pole MCCB 160 Amps with ultimate breaking capacity Icu-35 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts of 16 KA, thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (ii) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
E. Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 160 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following:- (Gen set model No. KEC-C160-II)
A. Diesel Engine: Water cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:-(Make: Kirloskar Model No. 6B5D-1C150RW Ltd/Cummins India Ltd). Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators.
(j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) battery voltage (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed. (v) Engine hours.
(vI) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-1No. 12 volts DC, 180AH, maintenance free battery with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. B. Alternator: Suitable rated at 160 KVA factor , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H IP -23, self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before Make- Kirloskar Model No. 4AB280S1 STAMFORD/Crompton Greaves.
C. Acoustic Enclosure:- M & L for acoustic enclosure for the above 160 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton. D. AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(i) AMF control circuit with 4 pole MCCB 160 Amps with ultimate breaking capacity Icu-35 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts of 16 KA, thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (ii) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
E. Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
LIFT Design supply, install testing & commisioning passengers lift for 8 passenger 544 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 11 floors (G+10 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 13 passenger 844 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 11 floors (G+10 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 13 passenger 844 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 10 floors (G+9 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing systemwithout hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 8 passenger 544 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 10 floors (G+9 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 8 passenger 544 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 08 floors (G+7 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 13 passenger 844 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 8 floors (G+7 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing systemwithout hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 8 passenger 544 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 9 floors (G+8 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing systemwithout hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Design supply, install testing & commisioning passengers lift for 13 passenger 844 Kg, speed 1.5 meter/sec, lift with single speed motor 415 Volts, 3 phase, AC 50Hz supply conforming to IS14665, suitable to serve upto 9 floors (G+8 floors) upper floors with AC Variable Volatge & Variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlld operation with/without attendant, centre opening doors with door drice( electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing systemwithout hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Supply & fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3mm aluminum strip.
NSC Projects Pvt. Ltd.
Rabina Enterprises Pvt Ltd
SOOD ASSOCIATES PVT LTD
RAMJI DAS DHAL CONSTRUCTION PVT LTD
DES RAJ AND SONS BUILDERS PVT LTD
M. Venkata Rao Infra Projects Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid